AFAmin Abolhasani Foroughi

Amin Abolhasani Foroughi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Amin Abolhasani Foroughi has a total of 101 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The pelvic cavity as a novel site for accessory breast tissue: a case report

    by Kazem Tadayon, Seyyed Mohammad, Mohammad Mostafa Safarpour, Amir Reza Dehghanian, Amin Abolhasani Foroughi

  • Temporal changes in extra-axial brain hematoma's signal intensity in magnetic resonance images of trauma patients: A preliminary, technical study

    by Amin Abolhasani Foroughi, Ali Rahmani, Roham Borazjani, Masoume Nazeri, Banafsheh Zeinali-Rafsanjani, Hosseinali Khalili

  • Serum inflammatory markers in patients with multiple sclerosis and their association with clinical manifestations and MRI findings

    by Masoume Nazeri, Hanieh Bazrafshan, Amin Abolhasani Foroughi

    Inflammation in a myelinated portion of the nervous system is the mainstay of multiple sclerosis (MS). Elevation of inflammatory markers such as procalcitonin, ESR and hs-CRP is suspected to occur in MS patients. However, their prognostic role and their relationship with the severity of clinical symptoms of MS and MRI evidences has remained unnoticed in the literature. Hence, we aim to evaluate the serum level of inflammatory markers in the acute attack of MS patients and demonstrate the potential prognostic role of these inflammatory markers. This study was carried on case and control groups of definite MS patients. The cases were patients with active MS and were further allocated into four subgroups, while as control group included patients with non-active MS. Furthermore, all the participants underwent brain and cervical magnetic resonance imaging (MRI) using a contrast agent. A significant difference was detected in hs-CRP level (p = 0.009) across the subgroups of the cases. The highest level of hs-CRP was reported in patients with cerebellar and brain stem symptoms (mean = 6998.13 ± 3501.16), while the lowest in patients with pyramidal and urinary incontinence symptoms (mean = 1958.91 ± 2662.16). Moreover, correlation coefficient between values of MRI contrast-enhanced lesions and ESR level was statistically significant (Rs = 0.503 and p = 0.001). Elevation of ESR serum level positively correlates with disease activity evidenced by values of contrast-enhanced plaques of MRI in relapsing–remitting MS patients which may predict the disease activity. In addition, MS relapse with cerebellar and brain stem symptoms is associated with a high concentration of hs-CRP plasma level.


  • Brain TRODAT‐SPECT Versus MRI Morphometry in Distinguishing Early Mild Parkinson's Disease from Other Extrapyramidal Syndromes

    by Mohammad Reza Hossein‐Tehrani, Tahereh Ghaedian, Etrat Hooshmandi, Leila Kalhor, Amin Abolhasani Foroughi, Vahid Reza Ostovan

    BACKGROUND AND PURPOSE: The clinical differentiation of Parkinson's disease (PD) from other extrapyramidal syndromes has made a challenge in neurology. This study aimed to compare the specificity and sensitivity of brain MRI volumetry and dopamine transporter scans in differentiating PD from other extrapyramidal syndromes in the early stages of the disease.METHODS: This study included 34 patients younger than 70 years old with less than 3 years of extrapyramidal symptoms. Demographic and clinical history of the patients, including age, sex, and disease duration, was gathered. Disease severity was assessed using Unified Parkinson's Disease Rating Scale III (UPDRS III). For all patients, 99mTc‐TRODAT single‐photon emission computed tomography (SPECT) and MRI volumetry were performed. Patients were followed up for 1 year and examined for final diagnosis.RESULTS: According to the quantitative 99mTc‐TRODAT analysis, all of the specific binding ratio (SBR) parameters, including right, left, and bilateral SBRs, were significantly higher in the non‐Parkinsonian patients. Also, the results indicated a high diagnostic accuracy for both quantitative 99mTc‐TRODAT analysis (about 88% for SBR parameters) and MRI volumetry (71% for bilateral olfactory bulbs volume) in diagnosing PD. Regarding the diagnosis of PD, there were no significant differences between quantitative scan results and olfactory bulb volumetry according to the area under the receiver operating characteristic curves.CONCLUSION: 99mTc‐TRODAT has a higher accuracy in differentiation of early PD from non‐Parkinsonian conditions, particularly essential tremor. Olfactory bulbs volumetry by using MRI can also serve as a potential alternative method in this regard.


  • Open Access

    Comparison Between T2, STIR and PSIR Sequences, for Detection of Cervical Cord MS Plaques

    by Amin Abolhasani Foroughi, Mahdi Saeedi-Moghadam, Banafsheh Zeinali-Rafsanjani, Masoume Nazeri

    Multiple sclerosis (MS) is a demyelinating disease, involving almost 2.5 million people around the world. There are different MR pulse sequences, which are used to detect MS plaques.This study aimed to compare, T2 weighted, short-tau inversion recovery (STIR) and phase-sensitive inversion recovery (PSIR) pulse sequences, for detecting cervical spinal cord lesions in MS patients.Sixty patients with definite MS diagnoses, participated in this study from June to December 2016. 1.5 T Siemens (Avanto, Erlangen, Germany) MR scanner and three pulse sequences (T2 weighted, STIR and PSIR sequences) were used for cervical cord MR imaging. To assess the effectiveness of these pulse sequences, the lesion to cord ratio (LCR) and lesion to noise ratio (LNR) were calculated.The LCR and LNR of the T2 and PSIR were the same (LCR of 0.04, -0.03 and LNR of 2.74, -2.09 respectively), just the intensities were reverse. STIR had a significantly different LCR and LNR (0.23 (P < 0.001) and 22.7(P < 0.001) respectively), hence it was better in diagnosing cervical cord MS plaques.According to the results, using 1.5 T MRI machine, it implies that the STIR pulse sequence was the best pulse sequence in comparison to T2 and PSIR in detecting cervical cord MS plaques.


  • Open Access

    Validity and Reliability of the Persian Versions of National Institute of Health Stroke Scale and Modified National Institute of Health Stroke Scale in Hospitalized Patients

    by Reza Dehghani, Afshin Borhanihaghighi, Abdolhamid Shariat, Mohammad Nami, Masoume Nazeri, Amin Abolhasani Foroughi, Samrad Mehrabi, Masoumeh Emamghoreishi

    Background: National Institute of Health Stroke Scale (NIHSS) and Modified National Institute of Health Stroke Scale (mNIHSS) are two valid and reliable questionnaires that assess stroke severity. This study aimed to examine and compare the validity and reliability of Persian versions of NIHSS and mNIHSS in hospitalized patients. Materials and Methods: The English versions of NIHSS and mNIHSS were translated to Persian (forward and backward), and three neurologists examined the face and content validity of both questionnaires. The Persian versions of NIHSS and mNIHSS were used in75 hospitalized stroke patients (hemorrhagic and obstructive) admitted to Namazi teaching hospital, Shiraz, Iran.The reliability and validity of the Persian versions were examined by Cronbach's alpha coefficient and convergent validity. Result: The values of Cronbach's alpha for Persian versions of NIHSS and mNIHSS were 0.81 and 0.86, respectively. The scaling success of convergent validity in NIHSS and mNIHSS were 80% and 100%, respectively. Conclusion: The Persian versions of NIHSS and mNIHSS were reliable and valid. However, mNIHSS was more valid and reliable than NIHSS. Persian version of mNIHSS can be suggested to be used for assessing stroke severity in hospitalized stroke patients by neurologists and researchers. [GMJ. 2019;8:e1188]


  • The effects of Zataria multiflora Boiss. (Shirazi thyme) on nonalcoholic fatty liver disease and insulin resistance: A randomized double-blind placebo-controlled clinical trial

    by Nasrindokht Zamani, Mesbah Shams, Majid Nimrouzi, Mohammad Mehdi Zarshenas, Amin Abolhasani Foroughi, Ebrahim Fallahzadeh Abarghooei, Mohammad Reza Fattahi


  • Clinical grading and color Doppler ultrasonography-based grading of varicocele: how compatible are the two grading systems?

    by Amin Abolhasani Foroughi, Ehsan Yazdanpanah, Masoume Nazeri, Tannaz Eghbali, Peyman Arasteh, Ali Ariafar

    Objective Inhere, we compared two of the most common grading systems based on color Doppler ultrasonography (CDU) and physical examination in patients suspected of varicocele. Methods This is a cross-sectional study. Overall, 66 patients clinically suspected of varicocele were visited by an attending urologist and a radiologist for physical examination and CDU. Varicocele was then graded according to the WHO criteria and Sarteschi criteria. For comparing the results of the two grading systems, each grading systems was then categorized into four scoring groups. Clinical- and CDU-based scoring, and mean maximum variceal vein diameter (MMVD) were evaluated and compared. Results The two scoring systems were statistically similar (p < 0.001). CDU scoring of right and left testicles had significant agreement with clinical scoring of varicocele (κ = 0.723 and κ = 0.809, respectively; p < 0.001). MMDV was associated with clinical (right sided: r = 0.681; left sided: r = 0.797; p < 0.001) and ultrasonography scoring (right sided: r = 0.648; left sided: r = 0.821; p < 0.001). Conclusion Grades zero, one and two in ultrasonographic grading are most compatible with grade zero (sub-clinical) in clinical evaluation; so these grades most probably remain undetected in routine physical examination. Furthermore, grade three in ultrasonography and grade one in clinical grading, grade four in ultrasonography and grade two in clinical grading, and finally grade five in ultrasonography and grade three in clinical grading are most compatible. So, by deducting two grades from the ultrasonography grading of varicocele measured by the Sarteschi method, one can obtain a compatible estimate of the clinical grading.


  • Open Access

    Abnormal High Signal Intensity Discovered in Eye Lenses in Routine Brain MRI; Correlation with Ophthalmologist Examination

    by Amin Abolhasani Foroughi, Mohammad Hossein Nowroozzadeh, Ali Khorsand, Masoume Nazeri, Masoud Yasemi, Ruhollah Salahi

    Objectives: The aim of this study was to determine the possible role of brain magnetic resonance imaging (MRI) in cataract detection. Methods: This study was performed on patients who were referred to Shahid Faghihi hospital with a known disease for brain MRI. Patients were classified in two groups of case and controls. Cases were 44 eyes with abnormal signal of the lens and controls were 88 eyes with normal signal intensity of the lens. All patients underwent an ophthalmological examination and the presence of cataract and intraocular lens (IOL) was assessed in these patients. Average lens signal, average muscle signal, average fat signal, lens to muscle signal ratio, and average lens signal to average fat signal ratio were recorded. Results: The mean of the average lens signal in the case group was significantly higher than controls (370 versus 161, respectively) (P value < 0.0001). Sixteen (36.4%) out of 44 eyes in the case group had cataract, but 48 (54.5%) of 88 eyes in the control group had cataract (P value = 0.049). In the case group, 18.2% had IOL, and this was 6.8% in the controls (P value = 0.046). The mean of the average lens signal in eyes with cataract was 218.5 and in normal eyes, it was 249.1 (P value = 0.36). In eyes with IOL, the mean of the average lens signal was 347.5 and in normal eyes, this was 223.1 (P value = 0.036). Conclusions: Cataract in eyes with abnormal lens signal was significantly lower than eyes with normal lens average signal. The lens signal in eyes with cataract was similar to eyes without cataract. So, average lens signal in brain MRI does not lead to early detection of cataract. Keywords: Magnetic Resonance Imaging; Cataract; Lens Signal; Intraocular Lens