Jessica R. Balderston
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jessica R. Balderston has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Zachary M. Gertz
Division of Cardiology, Virginia Commonwealth University, Richmond, VA
5 shared publicationsDavid P. Evans
Department of Emergency Medicine Virginia Commonwealth University Richmond Virginia USA
4 shared publicationsChen Wang
Virginia Commonwealth Univ, Dept Biostat, Richmond, VA USA
2 shared publicationsJ. Michael Joyce
Departments of Emergency Medicine, Virginia Commonwealth University, Richmond, Virginia, USA
2 shared publications- Stephanie C. DeMasi
Department of Emergency Medicine, Vanderbilt University Medical Center, Nashville, TN
2 shared publications Adam Weltler
Department of Emergency Medicine Virginia Commonwealth University Richmond Virginia USA
1 shared publication
Latest Publications
- Open Access
- 1 March 2024
- Vol. 25 (2) , 264-267
Novel Scoring Scale for Quality Assessment of Lung Ultrasound in the Emergency Department
Introduction: The use of a reliable scoring system for quality assessment (QA) is imperative to limit inconsistencies in measuring ultrasound acquisition skills. The current grading scale used for QA endorsed by the American College of Emergency Physicians (ACEP) is non-specific, applies irrespective of the type of study performed, and has not been rigorously validated. Our goal in this study was to determine whether a succinct, organ-specific grading scale designed for lung-specific QA would be more precise with better interobserver agreement. Methods: This was a prospective validation study of an objective QA scale for lung ultrasound (LUS) in the emergency department. We identified the first 100 LUS performed in normal clinical practice in the year 2020. Four reviewers at an urban academic center who were either emergency ultrasound fellowship-trained or current fellows with at least six months of QA experience scored each study, resulting in a total of 400. The primary outcome was the level of agreement between the reviewers. Our secondary outcome was the variability of the scores given to the studies. For the agreement between reviewers, we computed the intraclass correlation coefficient (ICC) based on a two-way random-effect model with a single rater for each grading scale. We generated 10,000 bootstrapped ICCs to construct 95% confidence intervals (CI) for both grading systems. A two-sided one-sample t -test was used to determine whether there were differences in the bootstrapped ICCs between the two grading systems. Results: The ICC between reviewers was 0.552 (95% CI 0.40-0.68) for the ACEP grading scale and 0.703 (95% CI 0.59-0.79) for the novel grading scale (P < 0.001), indicating significantly more interobserver agreement using the novel scale compared to the ACEP scale. The variance of scores was similar (0.93 and 0.92 for the novel and ACEP scales, respectively). Conclusion: We found an increased interobserver agreement between reviewers when using the novel, organ-specific scale when compared with the ACEP grading scale. Increased consistency in feedback based on objective criteria directed to the specific, targeted organ provides an opportunity to enhance learner education and satisfaction with their ultrasound education.
- 1 March 2024
- Vol. 25 (2) , 264-267
Open AccessNovel Scoring Scale for Quality Assessment of Lung Ultrasound in the Emergency Department
Introduction: The use of a reliable scoring system for quality assessment (QA) is imperative to limit inconsistencies in measuring ultrasound acquisition skills. The current grading scale used for QA endorsed by the American College of Emergency Physicians (ACEP) is non-specific, applies irrespective of the type of study performed, and has not been rigorously validated. Our goal in this study was to determine whether a succinct, organ-specific grading scale designed for lung-specific QA would be more precise with better interobserver agreement. Methods: This was a prospective validation study of an objective QA scale for lung ultrasound (LUS) in the emergency department. We identified the first 100 LUS performed in normal clinical practice in the year 2020. Four reviewers at an urban academic center who were either emergency ultrasound fellowship-trained or current fellows with at least six months of QA experience scored each study, resulting in a total of 400. The primary outcome was the level of agreement between the reviewers. Our secondary outcome was the variability of the scores given to the studies. For the agreement between reviewers, we computed the intraclass correlation coefficient (ICC) based on a two-way random-effect model with a single rater for each grading scale. We generated 10,000 bootstrapped ICCs to construct 95% confidence intervals (CI) for both grading systems. A two-sided one-sample t -test was used to determine whether there were differences in the bootstrapped ICCs between the two grading systems. Results: The ICC between reviewers was 0.552 (95% CI 0.40-0.68) for the ACEP grading scale and 0.703 (95% CI 0.59-0.79) for the novel grading scale (P < 0.001), indicating significantly more interobserver agreement using the novel scale compared to the ACEP scale. The variance of scores was similar (0.93 and 0.92 for the novel and ACEP scales, respectively). Conclusion: We found an increased interobserver agreement between reviewers when using the novel, organ-specific scale when compared with the ACEP grading scale. Increased consistency in feedback based on objective criteria directed to the specific, targeted organ provides an opportunity to enhance learner education and satisfaction with their ultrasound education.
- Open Access
- 27 February 2023
- Published by Wiley in Academic Emergency Medicine
- Vol. 30 (6) , 653-661
Thoracic point‐of‐care ultrasound is an accurate diagnostic modality for clinically significant traumatic pneumothorax
Objective: There are conflicting data regarding the accuracy of thoracic point‐of‐care ultrasound (POCUS) in detecting traumatic pneumothorax (PTX). The purpose of our study was to determine the accuracy of thoracic POCUS performed by emergency physicians for the detection of clinically significant PTX in blunt and penetrating trauma patients.Methods: We conducted a retrospective institutional review board–approved study of trauma patients 15 years or older presenting to our urban Level I academic trauma center from December 2021 to June 2022. All study patients were imaged with single‐view chest radiography (CXR) and thoracic POCUS. The presence or absence of PTX was determined by multidetector computed tomography (CT) or CXR and ultrasound (US) with tube thoracostomy placement.Results: A total of 846 patients were included, with 803 (95%) sustaining blunt trauma. POCUS identified 13/15 clinically significant PTXs (defined as ≥35 mm of pleural separation on a blinded overread or placement of a tube thoracostomy prior to CT) with a sensitivity of 87% (95% confidence interval [CI] 58–97), specificity of 100% (95% CI 99–100), positive predictive value of 81% (95% CI 54%–95%), and negative predictive value of 100% (95% CI 99%–100%). The positive likelihood ratio was 484 and the negative likelihood ratio was 0.1. CXR identified eight (53%) clinically significant PTXs, with a sensitivity of 53% (95% CI 27%–78%) and a specificity of 100%, when correlated with the CT. The most common reason for a missed PTX identified on expert‐blinded overread was failure to recognize a lung point sign that was present on US.Conclusions: Thoracic POCUS accurately identifies the majority of clinically significant PTXs in both blunt and penetrating trauma patients. Common themes for false‐negative thoracic US in the expert‐blinded overread process identified key gaps in training to inspire US education and medical education research.
- 27 February 2023
- Published by Wiley in Academic Emergency Medicine
- Vol. 30 (6) , 653-661
Open AccessThoracic point‐of‐care ultrasound is an accurate diagnostic modality for clinically significant traumatic pneumothorax
Objective: There are conflicting data regarding the accuracy of thoracic point‐of‐care ultrasound (POCUS) in detecting traumatic pneumothorax (PTX). The purpose of our study was to determine the accuracy of thoracic POCUS performed by emergency physicians for the detection of clinically significant PTX in blunt and penetrating trauma patients.Methods: We conducted a retrospective institutional review board–approved study of trauma patients 15 years or older presenting to our urban Level I academic trauma center from December 2021 to June 2022. All study patients were imaged with single‐view chest radiography (CXR) and thoracic POCUS. The presence or absence of PTX was determined by multidetector computed tomography (CT) or CXR and ultrasound (US) with tube thoracostomy placement.Results: A total of 846 patients were included, with 803 (95%) sustaining blunt trauma. POCUS identified 13/15 clinically significant PTXs (defined as ≥35 mm of pleural separation on a blinded overread or placement of a tube thoracostomy prior to CT) with a sensitivity of 87% (95% confidence interval [CI] 58–97), specificity of 100% (95% CI 99–100), positive predictive value of 81% (95% CI 54%–95%), and negative predictive value of 100% (95% CI 99%–100%). The positive likelihood ratio was 484 and the negative likelihood ratio was 0.1. CXR identified eight (53%) clinically significant PTXs, with a sensitivity of 53% (95% CI 27%–78%) and a specificity of 100%, when correlated with the CT. The most common reason for a missed PTX identified on expert‐blinded overread was failure to recognize a lung point sign that was present on US.Conclusions: Thoracic POCUS accurately identifies the majority of clinically significant PTXs in both blunt and penetrating trauma patients. Common themes for false‐negative thoracic US in the expert‐blinded overread process identified key gaps in training to inspire US education and medical education research.
- Open Access
- 11 August 2022
- Published by Wiley in Academic Emergency Medicine
- Vol. 29 (10) , 1261-1263
Novel quality assessment methodology in focused cardiac ultrasound
- 11 August 2022
- Published by Wiley in Academic Emergency Medicine
- Vol. 29 (10) , 1261-1263
Open AccessNovel quality assessment methodology in focused cardiac ultrasound
- 1 March 2022
- Published by Elsevier in Annals of Emergency Medicine
- Vol. 79 (3) , 265-269
Covert Brain Infarction in Emergency Department Patients: Prevalence, Clinical Correlates, and Treatment Opportunities
- 1 March 2022
- Published by Elsevier in Annals of Emergency Medicine
- Vol. 79 (3) , 265-269
Covert Brain Infarction in Emergency Department Patients: Prevalence, Clinical Correlates, and Treatment Opportunities
- 1 December 2021
- Published by Elsevier in Resuscitation
- Vol. 169, 173-174
Echocardiography during cardiac arrest: Time to incorporate into ACLS?
- 1 December 2021
- Published by Elsevier in Resuscitation
- Vol. 169, 173-174
Echocardiography during cardiac arrest: Time to incorporate into ACLS?
- Open Access
- 26 May 2021
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 19 (1) , 1-5
Feasibility of focused cardiac ultrasound during cardiac arrest in the emergency department
Background: Focused cardiac ultrasound (FOCUS) can aid in evaluation and management of patients with cardiac arrest, but image quality in this population has been questioned. Our goal was to determine how often adequate imaging can be obtained in cardiac arrest patients. Methods: We conducted a prospective cohort study to examine the utility of FOCUS in cardiac arrest. All patients who presented to the Emergency Department (ED) in cardiac arrest or who had cardiac arrest while in the ED over 6 months were prospectively identified. FOCUS images were obtained as part of routine clinical care. Patients with images obtained were paired with age- and gender-matched controls who underwent FOCUS for another indication during the study period. Image quality was scored by two blinded reviewers using a 0–4 scale, with a score of ≥ 2 considered adequate. Results: There were 137 consecutive cardiac arrests, 121 out-of-hospital and 16 in-hospital, during the study period. FOCUS images were recorded in 126 (92%), who were included in the analysis. The average age was 58 years, and 45% were female. Ninety-seven studies (77%) were obtained during advanced cardiac life support while 29 (23%) were obtained after return of spontaneous circulation. The controls were appropriately matched. Of the cardiac arrest studies, 106 (84%) were rated adequate, compared to 116 (92%) in controls (p = 0.08). When compared to control FOCUS studies, the scores given to studies of cardiac arrest patients were lower (p = 0.001). Conclusions: FOCUS can reliably be used during cardiac arrest to obtain images adequate to answer clinical questions and guide therapies.
- 26 May 2021
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 19 (1) , 1-5
Open AccessFeasibility of focused cardiac ultrasound during cardiac arrest in the emergency department
Background: Focused cardiac ultrasound (FOCUS) can aid in evaluation and management of patients with cardiac arrest, but image quality in this population has been questioned. Our goal was to determine how often adequate imaging can be obtained in cardiac arrest patients. Methods: We conducted a prospective cohort study to examine the utility of FOCUS in cardiac arrest. All patients who presented to the Emergency Department (ED) in cardiac arrest or who had cardiac arrest while in the ED over 6 months were prospectively identified. FOCUS images were obtained as part of routine clinical care. Patients with images obtained were paired with age- and gender-matched controls who underwent FOCUS for another indication during the study period. Image quality was scored by two blinded reviewers using a 0–4 scale, with a score of ≥ 2 considered adequate. Results: There were 137 consecutive cardiac arrests, 121 out-of-hospital and 16 in-hospital, during the study period. FOCUS images were recorded in 126 (92%), who were included in the analysis. The average age was 58 years, and 45% were female. Ninety-seven studies (77%) were obtained during advanced cardiac life support while 29 (23%) were obtained after return of spontaneous circulation. The controls were appropriately matched. Of the cardiac arrest studies, 106 (84%) were rated adequate, compared to 116 (92%) in controls (p = 0.08). When compared to control FOCUS studies, the scores given to studies of cardiac arrest patients were lower (p = 0.001). Conclusions: FOCUS can reliably be used during cardiac arrest to obtain images adequate to answer clinical questions and guide therapies.
- Open Access
- 1 March 2021
- Published by American Medical Association (AMA) in JAMA Internal Medicine
- Vol. 181 (3) , 386-388
Differential Documentation of Race in the First Line of the History of Present Illness
Black patients frequently fare worse than White patients with respect to numerous health outcomes even after controlling for socioeconomic factors.1 In clinical situations where pathophysiology does not vary by race, patient race may predict differences in treatment and ultimate outcome.2-4 This suggests that racial bias is present and may be associated with variations in patient care. Our study looked for evidence of explicit racial bias in clinician documentation.
- 1 March 2021
- Published by American Medical Association (AMA) in JAMA Internal Medicine
- Vol. 181 (3) , 386-388
Open AccessDifferential Documentation of Race in the First Line of the History of Present Illness
Black patients frequently fare worse than White patients with respect to numerous health outcomes even after controlling for socioeconomic factors.1 In clinical situations where pathophysiology does not vary by race, patient race may predict differences in treatment and ultimate outcome.2-4 This suggests that racial bias is present and may be associated with variations in patient care. Our study looked for evidence of explicit racial bias in clinician documentation.
- Open Access
- 1 March 2021
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 61 (3) , 473-483
Systematic Review of the Co-Prevalence of Arterial Aneurysms Within the Vasculature
- 1 March 2021
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 61 (3) , 473-483
Open AccessSystematic Review of the Co-Prevalence of Arterial Aneurysms Within the Vasculature
- 12 May 2020
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 39 (11) , 2211-2217
Focused Cardiac Ultrasound in Dyspnea of Unclear Etiology in the Emergency Department
Objectives: We evaluated the utility of focused cardiac ultrasound to predict the length of stay in patients presenting to the emergency department with dyspnea of unclear etiology.Methods: Patients with focused cardiac ultrasound examinations performed in the emergency department for dyspnea over a 34‐month period were retrospectively identified. Patients were excluded if they had a prior diagnosis of heart failure, dialysis requirement, or an etiology of dyspnea unrelated to the volume status. Left ventricular function was categorized as normal or reduced, and the inferior vena cava was categorized as normal or increased volume. A fast limited ultrasound to investigate dyspnea (FLUID) score was calculated by adding 1 point for reduced left ventricular function and 1 point for increased volume, producing a score of 0, 1, or 2.Results: There were 123 patients included. There was a significant correlation between the FLUID score and length of stay, with longer stays for higher scores (FLUID score 0, 7.4 hours median; FLUID score 1, 2.34 days; FLUID score 2, 5.56 days; analysis of variance P < .001). Of the other variables collected, only age, hypertension, diabetes, heart rate, and brain natriuretic peptide were significantly correlated with the length of stay. A multivariate analysis including those variables and the FLUID score showed that the FLUID score was the strongest independent predictor of the length of stay.Conclusions: Focused cardiac ultrasound and calculation of a FLUID score for patients with undifferentiated dyspnea can be a powerful tool to predict the hospital length of stay.
- 12 May 2020
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 39 (11) , 2211-2217
Focused Cardiac Ultrasound in Dyspnea of Unclear Etiology in the Emergency Department
Objectives: We evaluated the utility of focused cardiac ultrasound to predict the length of stay in patients presenting to the emergency department with dyspnea of unclear etiology.Methods: Patients with focused cardiac ultrasound examinations performed in the emergency department for dyspnea over a 34‐month period were retrospectively identified. Patients were excluded if they had a prior diagnosis of heart failure, dialysis requirement, or an etiology of dyspnea unrelated to the volume status. Left ventricular function was categorized as normal or reduced, and the inferior vena cava was categorized as normal or increased volume. A fast limited ultrasound to investigate dyspnea (FLUID) score was calculated by adding 1 point for reduced left ventricular function and 1 point for increased volume, producing a score of 0, 1, or 2.Results: There were 123 patients included. There was a significant correlation between the FLUID score and length of stay, with longer stays for higher scores (FLUID score 0, 7.4 hours median; FLUID score 1, 2.34 days; FLUID score 2, 5.56 days; analysis of variance P < .001). Of the other variables collected, only age, hypertension, diabetes, heart rate, and brain natriuretic peptide were significantly correlated with the length of stay. A multivariate analysis including those variables and the FLUID score showed that the FLUID score was the strongest independent predictor of the length of stay.Conclusions: Focused cardiac ultrasound and calculation of a FLUID score for patients with undifferentiated dyspnea can be a powerful tool to predict the hospital length of stay.
- 18 March 2019
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 38 (11) , 2845-2851
Diagnostic Yield and Accuracy of Bedside Echocardiography in the Emergency Department in Hemodynamically Stable Patients
Objectives: The goal of this study was to determine the diagnostic yield of focused cardiac ultrasound (FOCUS) in hemodynamically stable patients in the emergency department and secondarily to confirm the accuracy of these studies when compared to formal echocardiography.Methods: All hemodynamically stable adult patients who had an emergency physician–performed FOCUS examination completed over a 1‐year period were identified using our electronic ultrasound database. Hemodynamic stability was defined as presenting systolic blood pressure higher than 90 mm Hg and not requiring any form of positive pressure ventilation.Results: There were 1198 FOCUS examinations performed: 976 in hemodynamically stable patients who were included in our analysis. Twenty‐seven percent of patients had new findings, including 154 (16%) new diagnoses of reduced left ventricular function, 105 (11%) new pericardial effusions, and 44 (5%) new diagnoses of RV dilatation. Dyspnea as an indication for the FOCUS examination was the strongest predictor of a positive study. Of patients included, 28% underwent formal echocardiography within 2 days and were analyzed for concordance with regard to left ventricular function and the presence of pericardial effusion. Of 270 studies, 208 were accurate, and 62 were inaccurate, for raw agreement of 77% (κ = 0.53). When stratified by sonographer experience, there was no impact on accuracy.Conclusions: Focused cardiac ultrasound in the emergency department for hemodynamically stable patients revealed new findings in 27% of studies, with a modest correlation with formal echocardiography. In stable patients, FOCUS has the potential for rapid diagnosis of cardiac disease, particularly in patients with dyspnea.
- 18 March 2019
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 38 (11) , 2845-2851
Diagnostic Yield and Accuracy of Bedside Echocardiography in the Emergency Department in Hemodynamically Stable Patients
Objectives: The goal of this study was to determine the diagnostic yield of focused cardiac ultrasound (FOCUS) in hemodynamically stable patients in the emergency department and secondarily to confirm the accuracy of these studies when compared to formal echocardiography.Methods: All hemodynamically stable adult patients who had an emergency physician–performed FOCUS examination completed over a 1‐year period were identified using our electronic ultrasound database. Hemodynamic stability was defined as presenting systolic blood pressure higher than 90 mm Hg and not requiring any form of positive pressure ventilation.Results: There were 1198 FOCUS examinations performed: 976 in hemodynamically stable patients who were included in our analysis. Twenty‐seven percent of patients had new findings, including 154 (16%) new diagnoses of reduced left ventricular function, 105 (11%) new pericardial effusions, and 44 (5%) new diagnoses of RV dilatation. Dyspnea as an indication for the FOCUS examination was the strongest predictor of a positive study. Of patients included, 28% underwent formal echocardiography within 2 days and were analyzed for concordance with regard to left ventricular function and the presence of pericardial effusion. Of 270 studies, 208 were accurate, and 62 were inaccurate, for raw agreement of 77% (κ = 0.53). When stratified by sonographer experience, there was no impact on accuracy.Conclusions: Focused cardiac ultrasound in the emergency department for hemodynamically stable patients revealed new findings in 27% of studies, with a modest correlation with formal echocardiography. In stable patients, FOCUS has the potential for rapid diagnosis of cardiac disease, particularly in patients with dyspnea.