Latest Publications

  • Open Access

    Cherenkov emissions for studying tumor changes during radiation therapy: An exploratory study in domesticated dogs with naturally-occurring cancer

    by Ashlyn G. Rickard, Hiroto Yoshikawa, Gregory M. Palmer, Harrison Q. Liu, Mark W. Dewhirst, Michael W. Nolan, Xiaofeng Zhang

    Real-time monitoring of physiological changes of tumor tissue during radiation therapy (RT) could improve therapeutic efficacy and predict therapeutic outcomes. Cherenkov radiation is a normal byproduct of radiation deposited in tissue. Previous studies in rat tumors have confirmed a correlation between Cherenkov emission spectra and optical measurements of blood-oxygen saturation based on the tissue absorption coefficients. The purpose of this study is to determine if it is feasible to image Cherenkov emissions during radiation therapy in larger human-sized tumors of pet dogs with cancer. We also wished to validate the prior work in rats, to determine if Cherenkov emissions have the potential to act an indicator of blood-oxygen saturation or water-content changes in the tumor tissue–both of which have been correlated with patient prognosis. A DoseOptics camera, built to image the low-intensity emission of Cherenkov radiation, was used to measure Cherenkov intensities in a cohort of cancer-bearing pet dogs during clinical irradiation. Tumor type and location varied, as did the radiation fractionation scheme and beam arrangement, each planned according to institutional standard-of-care. Unmodulated radiation was delivered using multiple 6 MV X-ray beams from a clinical linear accelerator. Each dog was treated with a minimum of 16 Gy total, in ≥3 fractions. Each fraction was split into at least three subfractions per gantry angle. During each subfraction, Cherenkov emissions were imaged. We documented significant intra-subfraction differences between the Cherenkov intensities for normal tissue, whole-tumor tissue, tissue at the edge of the tumor and tissue at the center of the tumor (p<0.05). Additionally, intra-subfraction changes suggest that Cherenkov emissions may have captured fluctuating absorption properties within the tumor. Here we demonstrate that it is possible to obtain Cherenkov emissions from canine cancers within a fraction of radiotherapy. The entire optical spectrum was obtained which includes the window for imaging changes in water and hemoglobin saturation. This lends credence to the goal of using this method during radiotherapy in human patients and client-owned pets.


  • Noninvasive measurement of tissue blood oxygenation with Cerenkov imaging during therapeutic radiation delivery

    by Xiaofeng Zhang, Sai Kit Lam, Gregory Palmer, Shiva Das, Mark Oldham, Mark Dewhirst

    Tumor tissue oxygenation significantly affects the outcome of radiotherapy. Real-time monitoring of tumor hypoxia is highly desirable for effective radiotherapy, and is the basis for improved treatment because hypoxic tumor cells are more resistant to radiation damage than fully oxygenated cells. We propose to use Cerenkov imaging to monitor tumor hypoxia by means of tissue blood oxygenation without the need for any exogenous contrast agent. Using a rodent hypoxia model, we demonstrate that Cerenkov imaging can be used as a noninvasive and noncontact method to measure tissue blood oxygenation level during radiation delivery. The data from Cerenkov imaging were validated using near infrared spectrometry methods. The results demonstrate the feasibility of using Cerenkov imaging to monitor tumor hypoxia during therapeutic radiation delivery.


  • Open Access

    Time-Resolved Synchronous Fluorescence for Biomedical Diagnosis

    by Xiaofeng Zhang, Andrew Fales, Tuan Vo-Dinh

    This article presents our most recent advances in synchronous fluorescence (SF) methodology for biomedical diagnostics. The SF method is characterized by simultaneously scanning both the excitation and emission wavelengths while keeping a constant wavelength interval between them. Compared to conventional fluorescence spectroscopy, the SF method simplifies the emission spectrum while enabling greater selectivity, and has been successfully used to detect subtle differences in the fluorescence emission signatures of biochemical species in cells and tissues. The SF method can be used in imaging to analyze dysplastic cells in vitro and tissue in vivo. Based on the SF method, here we demonstrate the feasibility of a time-resolved synchronous fluorescence (TRSF) method, which incorporates the intrinsic fluorescent decay characteristics of the fluorophores. Our prototype TRSF system has clearly shown its advantage in spectro-temporal separation of the fluorophores that were otherwise difficult to spectrally separate in SF spectroscopy. We envision that our previously-tested SF imaging and the newly-developed TRSF methods will combine their proven diagnostic potentials in cancer diagnosis to further improve the efficacy of SF-based biomedical diagnostics.


  • Open Access

    Instrumentation in Diffuse Optical Imaging

    by Xiaofeng Zhang

    Diffuse optical imaging is highly versatile and has a very broad range of applications in biology and medicine. It covers diffuse optical tomography, fluorescence diffuse optical tomography, bioluminescence and a number of other new imaging methods. These methods of diffuse optical imaging have diversified instrument configurations, but share the same core physical principle: light propagation in highly diffusive media, i.e., biological tissue. In this review, the author summarizes the latest development in instrumentation and methodology available to diffuse optical imaging in terms of system architecture, light source, photo-detection, spectral separation, signal modulation and, lastly, imaging contrast.


  • Super-resolution method for arbitrary retrospective sampling in fluorescence tomography with raster scanning photodetectors

    by Xiaofeng Zhang

    Dense spatial sampling is required in high-resolution optical imaging and many other biomedical optical imaging methods, such as diffuse optical imaging. Arrayed photodetectors, in particular charge coupled device cameras are commonly used mainly because of their high pixel count. Nonetheless, discrete-element photodetectors, such as photomultiplier tubes, are often desirable in many performance-demanding imaging applications. However, utilization of the discrete-element photodetectors typically requires raster scan to achieve arbitrary retrospective sampling with high density. Care must be taken in using the relatively large sensitive areas of discrete-element photodetectors to densely sample the image plane. In addition, off-line data analysis and image reconstruction often require full-field sampling. Pixel-by-pixel scanning is not only slow but also unnecessary in diffusion-limited imaging. We propose a superresolution method that can recover the finer features of an image sampled with a coarse-scale sensor. This generalpurpose method was established on the spatial transfer function of the photodetector-lens system, and achieved superresolution by inversion of this linear transfer function. Regularized optimization algorithms were used to achieve optimized deconvolution. Compared to the uncorrected blurred image, the proposed super-resolution method significantly improved image quality in terms of resolution and quantitation. Using this reconstruction method, the acquisition speed with a scanning photodetector can be dramatically improved without significantly sacrificing sampling density or flexibility.

  • Open Access

    Detectability of Absorption and Reduced Scattering Coefficients in Frequency-Domain Measurements Using a Realistic Head Phantom

    by Xiaofeng Zhang, Andrew Webb

    Detection limits of the changes in absorption and reduced scattering coefficients were investigated using a frequency-domain near-infrared system in a realistic head phantom. The results were quantified in terms of the maximum detectable depth for different activation volumes in the range of 0.8–20 microliters. The non-linear relation between the maximum detectable depth and the magnitude of changes in the absorption coefficient conform well with the Born approximation to the diffusion equation. The minimal detectable changes in the reduced scattering coefficient measured in terms of the phase signal were found to be approximately twice as large as that of the absorption coefficient using the AC signal for the same volume and at the same depth. The phase delay, which can be used to quantify the fast neuronal optical response in the human brain, showed a linear dependence on the reciprocal of the reduced scattering coefficient, as predicted by the Rytov approximation.


  • Construction of the Jacobian matrix for fluorescence diffuse optical tomography using a perturbation Monte Carlo method

    by Xiaofeng Zhang

    Image formation in fluorescence diffuse optical tomography is critically dependent on construction of the Jacobian matrix. For clinical and preclinical applications, because of the highly heterogeneous characteristics of the medium, Monte Carlo methods are frequently adopted to construct the Jacobian. Conventional adjoint Monte Carlo method typically compute the Jacobian by multiplying the photon density fields radiated from the source at the excitation wavelength and from the detector at the emission wavelength. Nonetheless, this approach assumes that the source and the detector in Green's function are reciprocal, which is invalid in general. This assumption is particularly questionable in small animal imaging, where the mean free path length of photons is typically only one order of magnitude smaller than the representative dimension of the medium. We propose a new method that does not rely on the reciprocity of the source and the detector by tracing photon propagation entirely from the source to the detector. This method relies on the perturbation Monte Carlo theory to account for the differences in optical properties of the medium at the excitation and the emission wavelengths. Compared to the adjoint methods, the proposed method is more valid in reflecting the physical process of photon transport in diffusive media and is more efficient in constructing the Jacobian matrix for densely sampled configurations.


  • Open Access

    High-resolution reconstruction of fluorescent inclusions in mouse thorax using anatomically guided sampling and parallel Monte Carlo computing

    by Xiaofeng Zhang, Cristian Badea, Greg Hood, Arthur Wetzel, Yi Qi, Joel Stiles, G. Allan Johnson

    We present a method for high-resolution reconstruction of fluorescent images of the mouse thorax. It features an anatomically guided sampling method to retrospectively eliminate problematic data and a parallel Monte Carlo software package to compute the Jacobian matrix for the inverse problem. The proposed method was capable of resolving microliter-sized femtomole amount of quantum dot inclusions closely located in the middle of the mouse thorax. The reconstruction was verified against co-registered micro-CT data. Using the proposed method, the new system achieved significantly higher resolution and sensitivity compared to our previous system consisting of the same hardware. This method can be applied to any system utilizing similar imaging principles to improve imaging performance.


  • Open Access

    Highly efficient detection in fluorescence tomography of quantum dots using time-gated acquisition and ultrafast pulsed laser

    by Xiaofeng Zhang, Cristian T. Badea

    Quantum dots (QDs) are widely used in fluorescence tomography due to its unique advantages. Despite the very high quantum efficiency of the QDs, low fluorescent signal and autofluorescence are the most fundamental limitations in optical data acquisition. These limitations are particularly detrimental to image reconstruction for animal imaging, e.g., free-space in vivo fluorescence tomography. In animals studies, fluorescent emission from exogenous fluorescent probes (e.g. QDs) cannot be effectively differentiated from endogenous broad-spectral substances (mostly proteins) using optical filters. In addition, a barrow-band fluorescent filter blocks the majority of the fluorescent light and thus makes signal acquisition very inefficient. We made use of the long fluorescent lifetime of the QDs to reject the optical signal due to the excitation light pulse, and therefore eliminated the need for a fluorescent filter during acquisition. Fluorescent emission from the QDs was excited with an ultrafast pulsed laser, and was detected using a time-gated image intensifier. A tissue-simulating imaging phantom was used to validate the proposed method. Compared to the standard acquisition method that uses a narrow-band fluorescent filter, the proposed method is significantly more efficient in data acquisition (by a factor of >10 in terms of fluorescent signal intensity) and demonstrated reduction in autofluorescence. No additional imaging artifact was observed in the tomographic reconstruction.

  • Open Access

    Free-space fluorescence tomography with adaptive sampling based on anatomical information from microCT

    by Xiaofeng Zhang, Cristian T. Badea, Greg Hood, Arthur W. Wetzel, Joel R. Stiles, G. Allan Johnson

    Image reconstruction is one of the main challenges for fluorescence tomography. For in vivo experiments on small animals, in particular, the inhomogeneous optical properties and irregular surface of the animal make free-space image reconstruction challenging because of the difficulties in accurately modeling the forward problem and the finite dynamic range of the photodetector. These two factors are fundamentally limited by the currently available forward models and photonic technologies. Nonetheless, both limitations can be significantly eased using a signal processing approach. We have recently constructed a free-space panoramic fluorescence diffuse optical tomography system to take advantage of co-registered microCT data acquired from the same animal. In this article, we present a data processing strategy that adaptively selects the optical sampling points in the raw 2-D fluorescent CCD images. Specifically, the general sampling area and sampling density are initially specified to create a set of potential sampling points sufficient to cover the region of interest. Based on 3-D anatomical information from the microCT and the fluorescent CCD images, data points are excluded from the set when they are located in an area where either the forward model is known to be problematic (e.g., large wrinkles on the skin) or where the signal is unreliable (e.g., saturated or low signal-to-noise ratio). Parallel Monte Carlo software was implemented to compute the sensitivity function for image reconstruction. Animal experiments were conducted on a mouse cadaver with an artificial fluorescent inclusion. Compared to our previous results using a finite element method, the newly developed parallel Monte Carlo software and the adaptive sampling strategy produced favorable reconstruction results.