Bastien Milani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Bastien Milani has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Menno Pruijm
Service of Nephrology, University Hospital of Lausanne and University of Lausanne, Lausanne, Switzerland
4 shared publications - Benedetta Franceschiello
Institute of Systems Engineering, HES-SO Valais-Wallis University, Sion, Switzerland
3 shared publications - Christopher W. Roy
Department of Radiology Lausanne University Hospital (CHUV) and University of Lausanne (UNIL) Lausanne Switzerland
3 shared publications - Jean-Baptiste Ledoux
Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
3 shared publications - Jérôme Yerly
Department of Radiology Lausanne University Hospital (CHUV) and University of Lausanne (UNIL) Lausanne Switzerland
3 shared publications - Matthias Stuber
IHU LIRYC, Heart Rhythm Disease Institute, Hôpital Xavier Arnozan, Université de Bordeaux—INSERM U1045 , Avenue du Haut Lévêque, Pessac 33604
3 shared publications
Latest Publications
- Open Access
Monalisa: an open source, documented MATLAB toolbox for magnetic resonance imaging reconstruction
Summary: Purpose: An open-source, user-friendly MATLAB framework for Magnetic Resonance Imaging (MRI) reconstruction was developed to simplify the reconstruction process, with a specific focus on non-Cartesian imaging and dynamic applications in the presence of motion. Methods: Monalisa is decomposing the reconstruction pipeline into clear modular steps, including raw data reading with flexible file-type abstraction, trajectory computation, density compensation, advanced coil sensitivity mapping, and tailored binning strategies through its “mitosius” preprocessing stage. The framework supports a suite of reconstruction methods, including iterative-SENSE (also named CG-SENSE), GeneRalized Autocalibrating Partial Parallel Acquisition (GRAPPA) reconstructions, and regularized reconstructions supporting both spatial and temporal regularization using l 1 (Compressed Sensing (CS)) and l 2 techniques, accommodating both Cartesian and non-Cartesian acquisitions. We performed benchmark experiments comparing Monalisa with the Berkeley Advanced Reconstruction Toolbox (BART) toolbox on simulated 2D radial acquisitions. Results: Results of the comparison demonstrate competitive performance, yielding higher Structural Similarity Index (SSIM) and lower l 2 error. Notably, Monalisa reconstructions exhibited fewer visible artifacts than BART. Conclusion: By providing comprehensive documentation, Monalisa serves not only as a powerful tool for research and clinical imaging but also as an educational platform to facilitate innovation in MRI reconstruction.
Open AccessMonalisa: an open source, documented MATLAB toolbox for magnetic resonance imaging reconstruction
Summary: Purpose: An open-source, user-friendly MATLAB framework for Magnetic Resonance Imaging (MRI) reconstruction was developed to simplify the reconstruction process, with a specific focus on non-Cartesian imaging and dynamic applications in the presence of motion. Methods: Monalisa is decomposing the reconstruction pipeline into clear modular steps, including raw data reading with flexible file-type abstraction, trajectory computation, density compensation, advanced coil sensitivity mapping, and tailored binning strategies through its “mitosius” preprocessing stage. The framework supports a suite of reconstruction methods, including iterative-SENSE (also named CG-SENSE), GeneRalized Autocalibrating Partial Parallel Acquisition (GRAPPA) reconstructions, and regularized reconstructions supporting both spatial and temporal regularization using l 1 (Compressed Sensing (CS)) and l 2 techniques, accommodating both Cartesian and non-Cartesian acquisitions. We performed benchmark experiments comparing Monalisa with the Berkeley Advanced Reconstruction Toolbox (BART) toolbox on simulated 2D radial acquisitions. Results: Results of the comparison demonstrate competitive performance, yielding higher Structural Similarity Index (SSIM) and lower l 2 error. Notably, Monalisa reconstructions exhibited fewer visible artifacts than BART. Conclusion: By providing comprehensive documentation, Monalisa serves not only as a powerful tool for research and clinical imaging but also as an educational platform to facilitate innovation in MRI reconstruction.
- Open Access
- 5 June 2025
- Published by Wiley
A mathematics-driven method to set the tuning parameter in l1 -regularized least-square problems
Summary: We present ALMA (Algorithm for Lagrange Multipliers Approximation), an iterative method for selecting tuning parameters in generalized LASSO problems for MRI reconstruction, which is a special case of l 1 -regularized least-square problem. Standardized approaches are often manual or heuristic; ALMA addresses this by approximating adaptatively Lagrange multipliers during reconstruction. On simulated MRI data, ALMA achieved mSSIM ≥ 0.99 and pSNR ≥ 40 dB, showing robust and near-optimal performance. Purpose: To introduce ALMA, a method for adaptatively computing tuning parameters in generalized LASSO problems during MRI reconstruction. Methods: We simulated MRI data using the Shepp-Logan phantom, testing ALMA across 450 reconstructions with varying undersampling (10–20%) and noise levels (3–7%). Image quality was assessed using mSSIM, pSNR, and CJV. Results: ALMA achieved average mSSIM of 0 . 9951±0 . 0041, pSNR of 42 . 24±3 . 42 dB, and CJV of 0 . 0367±0 . 0125, converging in about 7 . 2±3 iterations. Conclusion: ALMA offers a reliable, automated alternative to manual tuning, producing high-quality reconstructions and showing promise for in vivo MRI applications.
- 5 June 2025
- Published by Wiley
Open AccessA mathematics-driven method to set the tuning parameter in l1 -regularized least-square problems
Summary: We present ALMA (Algorithm for Lagrange Multipliers Approximation), an iterative method for selecting tuning parameters in generalized LASSO problems for MRI reconstruction, which is a special case of l 1 -regularized least-square problem. Standardized approaches are often manual or heuristic; ALMA addresses this by approximating adaptatively Lagrange multipliers during reconstruction. On simulated MRI data, ALMA achieved mSSIM ≥ 0.99 and pSNR ≥ 40 dB, showing robust and near-optimal performance. Purpose: To introduce ALMA, a method for adaptatively computing tuning parameters in generalized LASSO problems during MRI reconstruction. Methods: We simulated MRI data using the Shepp-Logan phantom, testing ALMA across 450 reconstructions with varying undersampling (10–20%) and noise levels (3–7%). Image quality was assessed using mSSIM, pSNR, and CJV. Results: ALMA achieved average mSSIM of 0 . 9951±0 . 0041, pSNR of 42 . 24±3 . 42 dB, and CJV of 0 . 0367±0 . 0125, converging in about 7 . 2±3 iterations. Conclusion: ALMA offers a reliable, automated alternative to manual tuning, producing high-quality reconstructions and showing promise for in vivo MRI applications.
- Open Access
- 4 March 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (6) , 2386-2400
Free‐running 5D whole‐heart MRI for isotropic cardiac function measurements at 3T without contrast agents
Purpose: To optimize and characterize an interrupted 5D free‐running framework at 3 T for detailed cardiac function assessment without the use of breath holding or contrast agents. Methods: A free‐running 3D radial gradient echo sequence was periodically interrupted with a preparation and a recovery module to optimize native blood‐to‐myocardium contrast at 3 T. Lipid signal was suppressed using a numerically optimized water‐excitation RF pulse to reduce lipid streaking artifacts and to improve overall image quality. Optimal acquisition parameters were established for a 5‐min scan time using extended phase graph simulations. A compressed sensing‐based reconstruction incorporating cardiac and respiratory inter‐bin deformation fields was employed to generate 5D images of the whole heart. The sharpness and contrast between the left ventricular blood pool and myocardium, along with the functional measurements of the left ventricle from the 5D datasets, were compared to routine 2D cine imaging in 16 healthy volunteers and three patients referred for clinically indicated CMR. Results: The proposed method resulted in lower contrast vs. and sharpness vs. , but enabled similar left‐ventricle ejection fraction assessment , limits of , intraclass correlation with high reproducibility compared to 2D cine. Conclusion: The proposed contrast‐free, interrupted free‐running 5D imaging provides left ventricular functional assessments comparable to 2D cine at 3 T, while offering an improved patient experience through shorter scan times and free breathing.
- 4 March 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (6) , 2386-2400
Open AccessFree‐running 5D whole‐heart MRI for isotropic cardiac function measurements at 3T without contrast agents
Purpose: To optimize and characterize an interrupted 5D free‐running framework at 3 T for detailed cardiac function assessment without the use of breath holding or contrast agents. Methods: A free‐running 3D radial gradient echo sequence was periodically interrupted with a preparation and a recovery module to optimize native blood‐to‐myocardium contrast at 3 T. Lipid signal was suppressed using a numerically optimized water‐excitation RF pulse to reduce lipid streaking artifacts and to improve overall image quality. Optimal acquisition parameters were established for a 5‐min scan time using extended phase graph simulations. A compressed sensing‐based reconstruction incorporating cardiac and respiratory inter‐bin deformation fields was employed to generate 5D images of the whole heart. The sharpness and contrast between the left ventricular blood pool and myocardium, along with the functional measurements of the left ventricle from the 5D datasets, were compared to routine 2D cine imaging in 16 healthy volunteers and three patients referred for clinically indicated CMR. Results: The proposed method resulted in lower contrast vs. and sharpness vs. , but enabled similar left‐ventricle ejection fraction assessment , limits of , intraclass correlation with high reproducibility compared to 2D cine. Conclusion: The proposed contrast‐free, interrupted free‐running 5D imaging provides left ventricular functional assessments comparable to 2D cine at 3 T, while offering an improved patient experience through shorter scan times and free breathing.
- Open Access
- 9 October 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (3) , 975-992
High on sparsity: Interbin compensation of cardiac motion for improved assessment of left‐ventricular function using 5D whole‐heart MRI
Purpose: Cardiac magnetic resonance is the gold standard for evaluating left‐ventricular ejection fraction (LVEF). Standard protocols, however, can be inefficient, facing challenges due to significant operator and patient involvement. Although the free‐running framework (FRF) addresses these challenges, the potential of the extensive data it collects remains underutilized. Therefore, we propose to leverage the large amount of data collected by incorporating interbin cardiac motion compensation into FRF (FRF‐MC) to improve both image quality and LVEF measurement accuracy, while reducing the sensitivity to user‐defined regularization parameters.Methods: FRF‐MC consists of several steps: data acquisition, self‐gating signal extraction, deformation field estimations, and motion‐resolved reconstruction with interbin cardiac motion compensation. FRF‐MC was compared with the original 5D‐FRF method using LVEF and several image‐quality metrics. The cardiac regularization weight () was optimized for both methods by maximizing image quality without compromising LVEF measurement accuracy. Evaluations were performed in numerical simulations and in 9 healthy participants. In vivo images were assessed by blinded expert reviewers and compared with reference standard 2D‐cine images.Results: Both in silico and in vivo results revealed that FRF‐MC outperformed FRF in terms of image quality and LVEF accuracy. FRF‐MC reduced temporal blurring, preserving detailed anatomy even at higher cardiac regularization weights, and led to more accurate LVEF measurements. Optimized produced accurate LVEF for both methods compared with the 2D‐cine reference (FRF‐MC: 0.59% [−7.2%, 6.0%], p = 0.47; FRF: 0.86% [−8.5%, 6.7%], p = 0.36), but FRF‐MC resulted in superior image quality (FRF‐MC: 2.89 ± 0.58, FRF: 2.11 ± 0.47; p < 10−3).Conclusion: Incorporating interbin cardiac motion compensation significantly improved image quality, supported higher cardiac regularization weights without compromising LVEF measurement accuracy, and reduced sensitivity to user‐defined regularization parameters.
- 9 October 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (3) , 975-992
Open AccessHigh on sparsity: Interbin compensation of cardiac motion for improved assessment of left‐ventricular function using 5D whole‐heart MRI
Purpose: Cardiac magnetic resonance is the gold standard for evaluating left‐ventricular ejection fraction (LVEF). Standard protocols, however, can be inefficient, facing challenges due to significant operator and patient involvement. Although the free‐running framework (FRF) addresses these challenges, the potential of the extensive data it collects remains underutilized. Therefore, we propose to leverage the large amount of data collected by incorporating interbin cardiac motion compensation into FRF (FRF‐MC) to improve both image quality and LVEF measurement accuracy, while reducing the sensitivity to user‐defined regularization parameters.Methods: FRF‐MC consists of several steps: data acquisition, self‐gating signal extraction, deformation field estimations, and motion‐resolved reconstruction with interbin cardiac motion compensation. FRF‐MC was compared with the original 5D‐FRF method using LVEF and several image‐quality metrics. The cardiac regularization weight () was optimized for both methods by maximizing image quality without compromising LVEF measurement accuracy. Evaluations were performed in numerical simulations and in 9 healthy participants. In vivo images were assessed by blinded expert reviewers and compared with reference standard 2D‐cine images.Results: Both in silico and in vivo results revealed that FRF‐MC outperformed FRF in terms of image quality and LVEF accuracy. FRF‐MC reduced temporal blurring, preserving detailed anatomy even at higher cardiac regularization weights, and led to more accurate LVEF measurements. Optimized produced accurate LVEF for both methods compared with the 2D‐cine reference (FRF‐MC: 0.59% [−7.2%, 6.0%], p = 0.47; FRF: 0.86% [−8.5%, 6.7%], p = 0.36), but FRF‐MC resulted in superior image quality (FRF‐MC: 2.89 ± 0.58, FRF: 2.11 ± 0.47; p < 10−3).Conclusion: Incorporating interbin cardiac motion compensation significantly improved image quality, supported higher cardiac regularization weights without compromising LVEF measurement accuracy, and reduced sensitivity to user‐defined regularization parameters.
- Open Access
Improving 3D-CINE tTV-regularized whole-heart MRI reconstruction
Purpose To improve the image quality of 3D radial free-running MRI data of the heart through a deliberate and stepwise extension of the XD-GRASP reconstruction. Methods Ferumoxytol-enhanced cardiac free-running 3D-radial data were reconstructed using an XD-GRASP reconstruction improved by 4 new developments: motion-compensated temporal-Total-Variation (MC-tTV) regularization for 3D images, a new coil-sensitivity, a new k-space density compensation and a revisited conjugate-gradient-descent (with exact line search) for solving the least-square sub-problem of ADMM. The resulting images were compared quantitatively and qualitatively to reconstructions lacking some of the newly implemented measures. Also, the measurement of ejection-fraction by a threshold-based method on the new reconstruction was compared to a reference standard. Results The new reconstruction significantly increased the sharpness of the right coronary artery (4% to 6%, p < 0.05) and the left anterior descending coronary artery (4% to 5% p < 0.05). It also increased blood-myocardium interface sharpness (between 20% and 25%, p < 0.05) and decreases spatial-Total-Variation in the blood-pool (13%, p < 0.05). The qualitative evaluation suggests better anatomical depiction of small structures using the new reconstruction. As compared to a reference standard method, ejection fraction could also be correctly evaluated. Conclusion Compressed sensing image reconstruction for 3D-radial free-running cardiac acquisition was successfully improved by including MC-tTV regularization, a new density compensation, a new coil-sensitivity and a revisited conjugate-gradient-descent with exact line search. Quantitative and qualitative quality metrics demonstrated significant improvement in image quality when using the new reconstruction, while extracted dynamic information compared favorably with the gold standard.
Open AccessImproving 3D-CINE tTV-regularized whole-heart MRI reconstruction
Purpose To improve the image quality of 3D radial free-running MRI data of the heart through a deliberate and stepwise extension of the XD-GRASP reconstruction. Methods Ferumoxytol-enhanced cardiac free-running 3D-radial data were reconstructed using an XD-GRASP reconstruction improved by 4 new developments: motion-compensated temporal-Total-Variation (MC-tTV) regularization for 3D images, a new coil-sensitivity, a new k-space density compensation and a revisited conjugate-gradient-descent (with exact line search) for solving the least-square sub-problem of ADMM. The resulting images were compared quantitatively and qualitatively to reconstructions lacking some of the newly implemented measures. Also, the measurement of ejection-fraction by a threshold-based method on the new reconstruction was compared to a reference standard. Results The new reconstruction significantly increased the sharpness of the right coronary artery (4% to 6%, p < 0.05) and the left anterior descending coronary artery (4% to 5% p < 0.05). It also increased blood-myocardium interface sharpness (between 20% and 25%, p < 0.05) and decreases spatial-Total-Variation in the blood-pool (13%, p < 0.05). The qualitative evaluation suggests better anatomical depiction of small structures using the new reconstruction. As compared to a reference standard method, ejection fraction could also be correctly evaluated. Conclusion Compressed sensing image reconstruction for 3D-radial free-running cardiac acquisition was successfully improved by including MC-tTV regularization, a new density compensation, a new coil-sensitivity and a revisited conjugate-gradient-descent with exact line search. Quantitative and qualitative quality metrics demonstrated significant improvement in image quality when using the new reconstruction, while extracted dynamic information compared favorably with the gold standard.
- Open Access
- 17 January 2024
- Published by Springer Nature in Applied Mathematics & Optimization
- Vol. 89 (2) , 1-34
On the Determination of Lagrange Multipliers for a Weighted LASSO Problem Using Geometric and Convex Analysis Techniques
Compressed Sensing (CS) encompasses a broad array of theoretical and applied techniques for recovering signals, given partial knowledge of their coefficients, cf. Candés (C. R. Acad. Sci. Paris, Ser. I 346, 589–592 (2008)), Candés et al. (IEEE Trans. Inf. Theo (2006)), Donoho (IEEE Trans. Inf. Theo. 52(4), (2006)), Donoho et al. (IEEE Trans. Inf. Theo. 52(1), (2006)). Its applications span various fields, including mathematics, physics, engineering, and several medical sciences, cf. Adcock and Hansen (Compressive Imaging: Structure, Sampling, Learning, p. 2021), Berk et al. (2019 13th International conference on Sampling Theory and Applications (SampTA) pp. 1-5. IEEE (2019)), Brady et al. (Opt. Express 17(15), 13040–13049 (2009)), Chan (Terahertz imaging with compressive sensing. Rice University, USA (2010)), Correa et al. (2014 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP) pp. 7789–7793 (2014, May) IEEE), Gao et al. (Nature 516(7529), 74–77 (2014)), Liu and Kang (Opt. Express 18(21), 22010–22019 (2010)), McEwen and Wiaux (Mon. Notices Royal Astron. Soc. 413(2), 1318–1332 (2011)), Marim et al. (Opt. Lett. 35(6), 871–873 (2010)), Yu and Wang (Phys. Med. Biol. 54(9), 2791 (2009)), Yu and Wang (Phys. Med. Biol. 54(9), 2791 (2009)). Motivated by our interest in the mathematics behind Magnetic Resonance Imaging (MRI) and CS, we employ convex analysis techniques to analytically determine equivalents of Lagrange multipliers for optimization problems with inequality constraints, specifically a weighted LASSO with voxel-wise weighting. We investigate this problem under assumptions on the fidelity term $$\left\Vert Ax-b\right\Vert _2^2$$ , either concerning the sign of its gradient or orthogonality-like conditions of its matrix. To be more precise, we either require the sign of each coordinate of $$2(Ax-b)^TA$$ to be fixed within a rectangular neighborhood of the origin, with the side lengths of the rectangle dependent on the constraints, or we assume $$A^TA$$ to be diagonal. The objective of this work is to explore the relationship between Lagrange multipliers and the constraints of a weighted variant of LASSO, specifically in the mentioned cases where this relationship can be computed explicitly. As they scale the regularization terms of the weighted LASSO, Lagrange multipliers serve as tuning parameters for the weighted LASSO, prompting the question of their potential effective use as tuning parameters in applications like MR image reconstruction and denoising. This work represents an initial step in this direction.- 17 January 2024
- Published by Springer Nature in Applied Mathematics & Optimization
- Vol. 89 (2) , 1-34
Open AccessOn the Determination of Lagrange Multipliers for a Weighted LASSO Problem Using Geometric and Convex Analysis Techniques
Compressed Sensing (CS) encompasses a broad array of theoretical and applied techniques for recovering signals, given partial knowledge of their coefficients, cf. Candés (C. R. Acad. Sci. Paris, Ser. I 346, 589–592 (2008)), Candés et al. (IEEE Trans. Inf. Theo (2006)), Donoho (IEEE Trans. Inf. Theo. 52(4), (2006)), Donoho et al. (IEEE Trans. Inf. Theo. 52(1), (2006)). Its applications span various fields, including mathematics, physics, engineering, and several medical sciences, cf. Adcock and Hansen (Compressive Imaging: Structure, Sampling, Learning, p. 2021), Berk et al. (2019 13th International conference on Sampling Theory and Applications (SampTA) pp. 1-5. IEEE (2019)), Brady et al. (Opt. Express 17(15), 13040–13049 (2009)), Chan (Terahertz imaging with compressive sensing. Rice University, USA (2010)), Correa et al. (2014 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP) pp. 7789–7793 (2014, May) IEEE), Gao et al. (Nature 516(7529), 74–77 (2014)), Liu and Kang (Opt. Express 18(21), 22010–22019 (2010)), McEwen and Wiaux (Mon. Notices Royal Astron. Soc. 413(2), 1318–1332 (2011)), Marim et al. (Opt. Lett. 35(6), 871–873 (2010)), Yu and Wang (Phys. Med. Biol. 54(9), 2791 (2009)), Yu and Wang (Phys. Med. Biol. 54(9), 2791 (2009)). Motivated by our interest in the mathematics behind Magnetic Resonance Imaging (MRI) and CS, we employ convex analysis techniques to analytically determine equivalents of Lagrange multipliers for optimization problems with inequality constraints, specifically a weighted LASSO with voxel-wise weighting. We investigate this problem under assumptions on the fidelity term $$\left\Vert Ax-b\right\Vert _2^2$$ , either concerning the sign of its gradient or orthogonality-like conditions of its matrix. To be more precise, we either require the sign of each coordinate of $$2(Ax-b)^TA$$ to be fixed within a rectangular neighborhood of the origin, with the side lengths of the rectangle dependent on the constraints, or we assume $$A^TA$$ to be diagonal. The objective of this work is to explore the relationship between Lagrange multipliers and the constraints of a weighted variant of LASSO, specifically in the mentioned cases where this relationship can be computed explicitly. As they scale the regularization terms of the weighted LASSO, Lagrange multipliers serve as tuning parameters for the weighted LASSO, prompting the question of their potential effective use as tuning parameters in applications like MR image reconstruction and denoising. This work represents an initial step in this direction. - Open Access
On the determination of Lagrange Multipliers for a weighted LASSO problem using geometric and convex analysis techniques
Compressed Sensing (CS) encompasses a broad array of theoretical and applied techniques for recovering signals, given partial knowledge of their coefficients. Its applications span various fields, including mathematics, physics, engineering, and several medical sciences. Motivated by our interest in the mathematics behind Magnetic Resonance Imaging (MRI) and CS, we employ convex analysis techniques to analytically determine equivalents of Lagrange multipliers for optimization problems with inequality constraints, specifically a weighted LASSO with voxel-wise weighting. We investigate this problem under assumptions on the fidelity term $\Vert{Ax-b}\Vert_2^2$, either concerning the sign of its gradient or orthogonality-like conditions of its matrix. To be more precise, we either require the sign of each coordinate of $2(Ax-b)^TA$ to be fixed within a rectangular neighborhood of the origin, with the side lengths of the rectangle dependent on the constraints, or we assume $A^TA$ to be diagonal. The objective of this work is to explore the relationship between Lagrange multipliers and the constraints of a weighted variant of LASSO, specifically in the mentioned cases where this relationship can be computed explicitly. As they scale the regularization terms of the weighted LASSO, Lagrange multipliers serve as tuning parameters for the weighted LASSO, prompting the question of their potential effective use as tuning parameters in applications like MR image reconstruction and denoising. This work represents an initial step in this direction.Open AccessOn the determination of Lagrange Multipliers for a weighted LASSO problem using geometric and convex analysis techniques
Compressed Sensing (CS) encompasses a broad array of theoretical and applied techniques for recovering signals, given partial knowledge of their coefficients. Its applications span various fields, including mathematics, physics, engineering, and several medical sciences. Motivated by our interest in the mathematics behind Magnetic Resonance Imaging (MRI) and CS, we employ convex analysis techniques to analytically determine equivalents of Lagrange multipliers for optimization problems with inequality constraints, specifically a weighted LASSO with voxel-wise weighting. We investigate this problem under assumptions on the fidelity term $\Vert{Ax-b}\Vert_2^2$, either concerning the sign of its gradient or orthogonality-like conditions of its matrix. To be more precise, we either require the sign of each coordinate of $2(Ax-b)^TA$ to be fixed within a rectangular neighborhood of the origin, with the side lengths of the rectangle dependent on the constraints, or we assume $A^TA$ to be diagonal. The objective of this work is to explore the relationship between Lagrange multipliers and the constraints of a weighted variant of LASSO, specifically in the mentioned cases where this relationship can be computed explicitly. As they scale the regularization terms of the weighted LASSO, Lagrange multipliers serve as tuning parameters for the weighted LASSO, prompting the question of their potential effective use as tuning parameters in applications like MR image reconstruction and denoising. This work represents an initial step in this direction. - Open Access
- 11 July 2022
- Published by MDPI AG in Kidney and Dialysis
- Vol. 2 (3) , 407-418
Magnetic Resonance Imaging to Diagnose and Predict the Outcome of Diabetic Kidney Disease—Where Do We Stand?
Diabetic kidney disease (DKD) is a major public health problem and its incidence is rising. The disease course is unpredictable with classic biomarkers, and the search for new tools to predict adverse renal outcomes is ongoing. Renal magnetic resonance imaging (MRI) now enables the quantification of metabolic and microscopic properties of the kidneys such as single-kidney, cortical and medullary blood flow, and renal tissue oxygenation and fibrosis, without the use of contrast media. A rapidly increasing number of studies show that these techniques can identify early kidney damage in patients with DKD, and possibly predict renal outcome. This review provides an overview of the currently most frequently used techniques, a summary of the results of some recent studies, and our view on their potential applications, as well as the hurdles to be overcome for the integration of these techniques into the clinical care of patients with DKD.
- 11 July 2022
- Published by MDPI AG in Kidney and Dialysis
- Vol. 2 (3) , 407-418
Open AccessMagnetic Resonance Imaging to Diagnose and Predict the Outcome of Diabetic Kidney Disease—Where Do We Stand?
Diabetic kidney disease (DKD) is a major public health problem and its incidence is rising. The disease course is unpredictable with classic biomarkers, and the search for new tools to predict adverse renal outcomes is ongoing. Renal magnetic resonance imaging (MRI) now enables the quantification of metabolic and microscopic properties of the kidneys such as single-kidney, cortical and medullary blood flow, and renal tissue oxygenation and fibrosis, without the use of contrast media. A rapidly increasing number of studies show that these techniques can identify early kidney damage in patients with DKD, and possibly predict renal outcome. This review provides an overview of the currently most frequently used techniques, a summary of the results of some recent studies, and our view on their potential applications, as well as the hurdles to be overcome for the integration of these techniques into the clinical care of patients with DKD.
- Open Access
- 1 June 2019
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 9 (6) , 985-999
Exploring a new method for quantitative sodium MRI in the human upper leg with a surface coil and symmetrically arranged reference phantoms
Background: The aim of this study is to validate and evaluate the reproducibility of a new setup for the quantification of the tissue sodium concentration (TSC) in the human upper leg muscles with sodium MRI at 3 Tesla. This setup is making use of an emit and receive single loop surface coil together with a set of square, symmetrically arranged reference phantoms. As a second aim, the performances of two MRI protocols for the TSC quantification in the upper leg muscles are compared: one using an ultra-short echo time (UTE) 3-dimensional radial sequence (UTE-protocol), and the other one using standard gradient echo sequence (GRE-protocol). Methods: A validation test of the quantification of sodium concentration is performed in phantoms. The bias of the method is estimated and compared between both protocols. The reproducibility of TSC quantification is assessed in phantoms by the coefficient of variation (CV) and compared between both protocols. The reproducibility is also assessed in 11 health volunteers. Signal to noise ratio (SNR) maps are acquired in phantoms with both protocols in order to compare the resulting SNR. Results: The apparatus and post processing were successfully implemented. The bias of the method was smaller than 10% in phantoms (excepted for Na concentration of 10 mmol/L when using the GRE protocol). The reproducibility of the method using symmetrically arranged phantoms was high in phantoms and humans (CV Conclusions: The use of symmetrically arranged reference phantoms lead to reproducible results in phantoms and humans. Sodium imaging in the human upper leg with a single loop surface coil should be performed with a standard 2-dimensional GRE protocol if an optimal SNR is needed. However, the quantification of the fast and slow decay time constants of the sodium signal, which plays a role in the TSC quantification, still has to be done with a UTE sequence. Moreover, the quantification of sodium concentration is more accurate with the UTE protocol for small sodium concentrations (<20 mmol).
- 1 June 2019
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 9 (6) , 985-999
Open AccessExploring a new method for quantitative sodium MRI in the human upper leg with a surface coil and symmetrically arranged reference phantoms
Background: The aim of this study is to validate and evaluate the reproducibility of a new setup for the quantification of the tissue sodium concentration (TSC) in the human upper leg muscles with sodium MRI at 3 Tesla. This setup is making use of an emit and receive single loop surface coil together with a set of square, symmetrically arranged reference phantoms. As a second aim, the performances of two MRI protocols for the TSC quantification in the upper leg muscles are compared: one using an ultra-short echo time (UTE) 3-dimensional radial sequence (UTE-protocol), and the other one using standard gradient echo sequence (GRE-protocol). Methods: A validation test of the quantification of sodium concentration is performed in phantoms. The bias of the method is estimated and compared between both protocols. The reproducibility of TSC quantification is assessed in phantoms by the coefficient of variation (CV) and compared between both protocols. The reproducibility is also assessed in 11 health volunteers. Signal to noise ratio (SNR) maps are acquired in phantoms with both protocols in order to compare the resulting SNR. Results: The apparatus and post processing were successfully implemented. The bias of the method was smaller than 10% in phantoms (excepted for Na concentration of 10 mmol/L when using the GRE protocol). The reproducibility of the method using symmetrically arranged phantoms was high in phantoms and humans (CV Conclusions: The use of symmetrically arranged reference phantoms lead to reproducible results in phantoms and humans. Sodium imaging in the human upper leg with a single loop surface coil should be performed with a standard 2-dimensional GRE protocol if an optimal SNR is needed. However, the quantification of the fast and slow decay time constants of the sodium signal, which plays a role in the TSC quantification, still has to be done with a UTE sequence. Moreover, the quantification of sodium concentration is more accurate with the UTE protocol for small sodium concentrations (<20 mmol).
- 26 August 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (1) , 583-593
Image acquisition for intravoxel incoherent motion imaging of kidneys should be triggered at the instant of maximum blood velocity: evidence obtained with simulations and in vivo experiments
Purpose To demonstrate that diffusion‐weighted images should be acquired at the instant of maximum blood velocity in kidneys to extract the perfusion fraction (PF) by the bi‐exponential intravoxel incoherent motion model. Methods The PF values were measured in Monte‐Carlo simulations corresponding to different blood velocities with a constant known PF. The distribution of the measured PF values (PF‐distribution) was characterized quantitatively by 3 markers highlighting the deviation of the measurement from the true PF. Diffusion‐weighted images of kidneys were acquired in 10 healthy volunteers at the instant of maximal respectively minimal blood velocity in the renal artery (Vmax versus Vmin acquisition). The PF‐distributions measured from the Vmax and Vmin acquisitions were compared mutually and with simulated PF‐distributions using the 3 markers. A radiologist evaluated the quality of the PF maps. Results The PF‐distributions measured in the simulations were spread around the true PF value, and spreading was reduced as blood velocity increased. A comparison between simulated and in vivo PF‐distributions suggests that a similar phenomenon is plausible in vivo. The quality of the PF maps of the Vmax‐acquisition was scored higher by the radiologist than those of the Vmin‐acquisition in 95% of cases (19 of 20). Conclusions The PF maps are of better quality when the Vmax‐acquisition is used. We show evidence supporting the hypothesis that the variation of PF along the cardiac cycle is due to oscillations between a poor estimation when the blood velocity is low, and a better estimation when blood velocity is higher.
- 26 August 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (1) , 583-593
Image acquisition for intravoxel incoherent motion imaging of kidneys should be triggered at the instant of maximum blood velocity: evidence obtained with simulations and in vivo experiments
Purpose To demonstrate that diffusion‐weighted images should be acquired at the instant of maximum blood velocity in kidneys to extract the perfusion fraction (PF) by the bi‐exponential intravoxel incoherent motion model. Methods The PF values were measured in Monte‐Carlo simulations corresponding to different blood velocities with a constant known PF. The distribution of the measured PF values (PF‐distribution) was characterized quantitatively by 3 markers highlighting the deviation of the measurement from the true PF. Diffusion‐weighted images of kidneys were acquired in 10 healthy volunteers at the instant of maximal respectively minimal blood velocity in the renal artery (Vmax versus Vmin acquisition). The PF‐distributions measured from the Vmax and Vmin acquisitions were compared mutually and with simulated PF‐distributions using the 3 markers. A radiologist evaluated the quality of the PF maps. Results The PF‐distributions measured in the simulations were spread around the true PF value, and spreading was reduced as blood velocity increased. A comparison between simulated and in vivo PF‐distributions suggests that a similar phenomenon is plausible in vivo. The quality of the PF maps of the Vmax‐acquisition was scored higher by the radiologist than those of the Vmin‐acquisition in 95% of cases (19 of 20). Conclusions The PF maps are of better quality when the Vmax‐acquisition is used. We show evidence supporting the hypothesis that the variation of PF along the cardiac cycle is due to oscillations between a poor estimation when the blood velocity is low, and a better estimation when blood velocity is higher.