KDKlaus-Peter Dinse

Klaus-Peter Dinse

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Klaus-Peter Dinse has a total of 39 co-authors. Here are the top co-authors by number of shared publications:

  • Alexander Schnegg

    EPR4Energy, Max-Planck-Institut für chemische Energiekonversion, Stiftstraße 34–36, 45470 Mülheim an der Ruhr, Germany

    6 shared publications
  • Anh Chu

    Institute of Smart Sensors, Universität Stuttgart, Pfaffenwaldring 47, 70569 Stuttgart, Germany

    5 shared publications
  • Jens Anders

    Institute of Smart Sensors, Universität Stuttgart, Pfaffenwaldring 47, 70569 Stuttgart, Germany

    5 shared publications
  • Klaus Lips

    Berlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, 14109 Berlin, Germany

    5 shared publications
  • Joseph E. McPeak

    University of Copenhagen

    4 shared publications
  • Boris Naydenov

    Berlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, 14109 Berlin, Germany

    3 shared publications

Latest Publications

  • Open Access

    Microwave field mapping for EPR-on-a-chip experiments

    by Silvio Künstner, Joseph E. McPeak, Anh Chu, Michal Kern, Markus Wick, Klaus-Peter Dinse, Jens Anders, Boris Naydenov, Klaus Lips

    Electron paramagnetic resonance–on-a-chip (EPRoC) devices use small voltage-controlled oscillators (VCOs) for both the excitation and detection of the EPR signal, allowing access to unique sample environments by lifting the restrictions imposed by resonator-based EPR techniques. EPRoC devices have been successfully used at multiple frequencies (7 to 360 gigahertz) and have demonstrated their utility in producing high-resolution spectra in a variety of spin centers. To enable quantitative measurements using EPRoC devices, the spatial distribution of the B 1 field produced by the VCOs must be known. As an example, the field distribution of a 12-coil VCO array EPRoC operating at 14 gigahertz is described in this study. The frequency modulation–recorded EPR spectra of a “point”-like and a thin-film sample were investigated while varying the position of both samples in three directions. The results were compared to COMSOL simulations of the B 1 -field intensity. The EPRoC array sensitive volume was determined to be ~19 nanoliters. Implications for possible EPR applications are discussed.


  • Open Access

    Rapid-scan electron paramagnetic resonance using an EPR-on-a-Chip sensor

    by Silvio Künstner, Anh Chu, Klaus-Peter Dinse, Alexander Schnegg, Joseph E. McPeak, Boris Naydenov, Jens Anders, Klaus Lips

    Electron paramagnetic resonance (EPR) spectroscopy is the method of choice to investigate and quantify paramagnetic species in many scientific fields, including materials science and the life sciences. Common EPR spectrometers use electromagnets and microwave (MW) resonators, limiting their application to dedicated lab environments. Here, novel aspects of voltage-controlled oscillator (VCO)-based EPR-on-a-Chip (EPRoC) detectors are discussed, which have recently gained interest in the EPR community. More specifically, it is demonstrated that with a VCO-based EPRoC detector, the amplitude-sensitive mode of detection can be used to perform very fast rapid-scan EPR experiments with a comparatively simple experimental setup to improve sensitivity compared to the continuous-wave regime. In place of a MW resonator, VCO-based EPRoC detectors use an array of injection-locked VCOs, each incorporating a miniaturized planar coil as a combined microwave source and detector. A striking advantage of the VCO-based approach is the possibility of replacing the conventionally used magnetic field sweeps with frequency sweeps with very high agility and near-constant sensitivity. Here, proof-of-concept rapid-scan EPR (RS-EPRoC) experiments are performed by sweeping the frequency of the EPRoC VCO array with up to 400 THz s−1, corresponding to a field sweep rate of 14 kT s−1. The resulting time-domain RS-EPRoC signals of a micrometer-scale BDPA sample can be transformed into the corresponding absorption EPR signals with high precision. Considering currently available technology, the frequency sweep range may be extended to 320 MHz, indicating that RS-EPRoC shows great promise for future sensitivity enhancements in the rapid-scan regime.


  • Open Access

    Comment on mr-2021-40

    by Silvio Kuenstner, Anh Chu, Klaus-Peter Dinse, Alexander Schnegg, Joseph E. McPeak, Boris Naydenov, Jens Anders, Klaus Lips

    Electron paramagnetic resonance (EPR) spectroscopy is the method of choice to investigate and quantify paramagnetic species in many scientific fields, including materials science and the life sciences. Common EPR spectrometers use electromagnets and microwave (MW) resonators, limiting their application to dedicated lab environments. Here, we present an improved design of a miniaturized EPR spectrometer implemented on a silicon microchip (EPR-on-a-chip, EPRoC). In place of a microwave resonator, EPRoC uses an array of injection-locked voltage-controlled oscillators (VCOs), each incorporating a 200 µm diameter coil, as a combined microwave source and detector. The individual miniaturized VCO elements provide an excellent spin sensitivity reported to be about 4 × 109 spins/√Hz, which is extended by the array over a larger area for improved concentration sensitivity. A striking advantage of this design is the possibility to sweep the MW frequency instead of the magnetic field, which allows the use of smaller, permanent magnets instead of the bulky and power-hungry electromagnets required for field-swept EPR. Here, we report rapid scan EPR (RS-EPRoC) experiments performed by sweeping the frequency of the EPRoC VCO array. RS-EPRoC spectra demonstrate an improved SNR by approximately two orders of magnitude for similar signal acquisition times compared to continuous wave (CW-EPRoC) methods, which may improve the absolute spin and concentration sensitivity of EPR-on-a-Chip at 14 GHz to about 6 × 107 spins/√Hz and 3.6 nM/√Hz, respectively.

  • Open Access

    Comment on mr-2021-40

    by Silvio Künstner, Anh Chu, Klaus-Peter Dinse, Alexander Schnegg, Joseph E. McPeak, Boris Naydenov, Jens Anders, Klaus Lips

    Electron paramagnetic resonance (EPR) spectroscopy is the method of choice to investigate and quantify paramagnetic species in many scientific fields, including materials science and the life sciences. Common EPR spectrometers use electromagnets and microwave (MW) resonators, limiting their application to dedicated lab environments. Here, we present an improved design of a miniaturized EPR spectrometer implemented on a silicon microchip (EPR-on-a-chip, EPRoC). In place of a microwave resonator, EPRoC uses an array of injection-locked voltage-controlled oscillators (VCOs), each incorporating a 200 µm diameter coil, as a combined microwave source and detector. The individual miniaturized VCO elements provide an excellent spin sensitivity reported to be about 4 × 109 spins/√Hz, which is extended by the array over a larger area for improved concentration sensitivity. A striking advantage of this design is the possibility to sweep the MW frequency instead of the magnetic field, which allows the use of smaller, permanent magnets instead of the bulky and power-hungry electromagnets required for field-swept EPR. Here, we report rapid scan EPR (RS-EPRoC) experiments performed by sweeping the frequency of the EPRoC VCO array. RS-EPRoC spectra demonstrate an improved SNR by approximately two orders of magnitude for similar signal acquisition times compared to continuous wave (CW-EPRoC) methods, which may improve the absolute spin and concentration sensitivity of EPR-on-a-Chip at 14 GHz to about 6 × 107 spins/√Hz and 3.6 nM/√Hz, respectively.

  • Open Access

    Comment on mr-2021-40

    by Silvio Künstner, Anh Chu, Klaus-Peter Dinse, Alexander Schnegg, Joseph E. McPeak, Boris Naydenov, Jens Anders, Klaus Lips

    Electron paramagnetic resonance (EPR) spectroscopy is the method of choice to investigate and quantify paramagnetic species in many scientific fields, including materials science and the life sciences. Common EPR spectrometers use electromagnets and microwave (MW) resonators, limiting their application to dedicated lab environments. Here, we present an improved design of a miniaturized EPR spectrometer implemented on a silicon microchip (EPR-on-a-chip, EPRoC). In place of a microwave resonator, EPRoC uses an array of injection-locked voltage-controlled oscillators (VCOs), each incorporating a 200 µm diameter coil, as a combined microwave source and detector. The individual miniaturized VCO elements provide an excellent spin sensitivity reported to be about 4 × 109 spins/√Hz, which is extended by the array over a larger area for improved concentration sensitivity. A striking advantage of this design is the possibility to sweep the MW frequency instead of the magnetic field, which allows the use of smaller, permanent magnets instead of the bulky and power-hungry electromagnets required for field-swept EPR. Here, we report rapid scan EPR (RS-EPRoC) experiments performed by sweeping the frequency of the EPRoC VCO array. RS-EPRoC spectra demonstrate an improved SNR by approximately two orders of magnitude for similar signal acquisition times compared to continuous wave (CW-EPRoC) methods, which may improve the absolute spin and concentration sensitivity of EPR-on-a-Chip at 14 GHz to about 6 × 107 spins/√Hz and 3.6 nM/√Hz, respectively.

  • Open Access

    Rapid Scan Electron Paramagnetic Resonance using an EPR-on-a-Chip Sensor

    by Silvio Künstner, Anh Chu, Klaus-Peter Dinse, Alexander Schnegg, Joseph E. McPeak, Boris Naydenov, Jens Anders, Klaus Lips

    Electron paramagnetic resonance (EPR) spectroscopy is the method of choice to investigate and quantify paramagnetic species in many scientific fields, including materials science and the life sciences. Common EPR spectrometers use electromagnets and microwave (MW) resonators, limiting their application to dedicated lab environments. Here, we present an improved design of a miniaturized EPR spectrometer implemented on a silicon microchip (EPR-on-a-chip, EPRoC). In place of a microwave resonator, EPRoC uses an array of injection-locked voltage-controlled oscillators (VCOs), each incorporating a 200 µm diameter coil, as a combined microwave source and detector. The individual miniaturized VCO elements provide an excellent spin sensitivity reported to be about 4 × 109 spins/√Hz, which is extended by the array over a larger area for improved concentration sensitivity. A striking advantage of this design is the possibility to sweep the MW frequency instead of the magnetic field, which allows the use of smaller, permanent magnets instead of the bulky and power-hungry electromagnets required for field-swept EPR. Here, we report rapid scan EPR (RS-EPRoC) experiments performed by sweeping the frequency of the EPRoC VCO array. RS-EPRoC spectra demonstrate an improved SNR by approximately two orders of magnitude for similar signal acquisition times compared to continuous wave (CW-EPRoC) methods, which may improve the absolute spin and concentration sensitivity of EPR-on-a-Chip at 14 GHz to about 6 × 107 spins/√Hz and 3.6 nM/√Hz, respectively.

  • Open Access

    EPR study of NO radicals encased in modified open C60 fullerenes

    by Klaus-Peter Dinse, Tatsuhisa Kato, Shota Hasegawa, Yoshifumi Hashikawa, Yasujiro Murata, Robert Bittl

    Using pulsed electron paramagnetic resonance (EPR) techniques, the low-temperature magnetic properties of the NO radical being confined in two different modified open C60-derived cages are determined. It is found that the smallest principal g value g3, being assigned to the axis of the radical, deviates strongly from the free electron value. This behaviour results from partial compensation of the spin and orbital contributions to the g3 value. The measured g3 values in the range of 0.7 yield information about the deviation of the locking potential for the encaged NO from axial symmetry. The estimated 17 meV asymmetry is quite small compared to the situation found for the same radical in polycrystalline or amorphous matrices ranging from 300 to 500 meV. The analysis of the temperature dependence of spin relaxation times resulted in an activation temperature of about 3 K, assigned to temperature-activated motion of the NO within the modified open C60-derived cages with coupled rotational and translational degrees of freedom in a complicated three-dimensional locking potential.


  • Open Access

    EPR Study of NO radicals encased in modified open C60 Fullerenes

    by Klaus-Peter Dinse, Tatsuhisa Kato, Shota Hasegawa, Yoshifumi Hashikawa, Yasujiro Murata, Robert Bittl

    Using pulsed EPR techniques, the low temperature magnetic properties of the NO radical being confined in a C60 derived cage are determined. It is found that the smallest principal g value g3, being assigned to the axis of the radical, deviates strongly from the free electron value. This behavior results from partial compensation of the spin and orbital contributions to the g3 value. The measured value g3 = 0.77(5) yields information about the deviation of the locking potential from axial symmetry. This 17 meV asymmetry is found to be quite small compared to the situation found for the same radical in polycrystalline or amorphous matrices ranging from 300 to 500 meV. The analysis of the temperature dependence of spin relaxation times resulted in a critical temperature of about 3.5 K, assigned to temperature activated motion of the radical with coupled rotational and translational degrees of freedom in the complicated 3-dimensional potential.

  • Magnetic Properties of Reduced and Reoxidized Mn–Na2WO4/SiO2: A Catalyst for Oxidative Coupling of Methane (OCM)

    by Wiebke Riedel, Lukas Thum, Jannik Möser, Vinzenz Fleischer, Ulla Simon, Konrad Siemensmeyer, Alexander Schnegg, Reinhard Schomäcker, Thomas Risse, Klaus-Peter Dinse


  • Alignment of the endohedral fullerenesN@C60andN@C70in a liquid-crystal matrix

    by Carola Meyer, Wolfgang Harneit, Klaus Lips, Alois Weidinger, Peter Jakes, Klaus-Peter Dinse

    Endohedral fullerenes N@C60 and N@C70 were dissolved in a liquid crystal and investigated by electron paramagnetic resonance. Sharp, liquid solution like spectra are observed. However, contrary to the usual solution spectra, the lines are split, indicating that the electron shell of the enclosed nitrogen atom is deformed and that an alignment with respect to the magnetic-field axis is achieved. The present results are of practical interest for controlling the interaction of endohedral fullerenes in a quantum computer.