Qin Qin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qin Qin has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Chengyu Liu
Southeast University
2 shared publications - Fan Yang
Huadian Electric Power Research Institute Co., Ltd. (CHDER), Hangzhou 310030, China
1 shared publication - He Huang
North Carolina State University
1 shared publication Jianqing Li
1 shared publication- Jianqing Li
Southeast University
1 shared publication - Kun Wang
Northeastern University
1 shared publication
Latest Publications
- Open Access
- 5 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 20789-20800
Electrocardiogram of a Silver Nanowire Based Dry Electrode: Quantitative Comparison With the Standard Ag/AgCl Gel Electrode
- 5 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 20789-20800
Open AccessElectrocardiogram of a Silver Nanowire Based Dry Electrode: Quantitative Comparison With the Standard Ag/AgCl Gel Electrode
- Open Access
- 13 December 2018
- Published by Springer Nature in Korean Journal of Chemical Engineering
- Vol. 36 (1) , 84-91
Sensitivity analysis of key factors in controlling absorption and desorption of oxygen to oxygen carriers
- 13 December 2018
- Published by Springer Nature in Korean Journal of Chemical Engineering
- Vol. 36 (1) , 84-91
Open AccessSensitivity analysis of key factors in controlling absorption and desorption of oxygen to oxygen carriers
- Open Access
- 20 July 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 6067
Combining Low-dimensional Wavelet Features and Support Vector Machine for Arrhythmia Beat Classification
Automatic feature extraction and classification are two main tasks in abnormal ECG beat recognition. Feature extraction is an important prerequisite prior to classification since it provides the classifier with input features, and the performance of classifier depends significantly on the quality of these features. This study develops an effective method to extract low-dimensional ECG beat feature vectors. It employs wavelet multi-resolution analysis to extract time-frequency domain features and then applies principle component analysis to reduce the dimension of the feature vector. In classification, 12-element feature vectors characterizing six types of beats are used as inputs for one-versus-one support vector machine, which is conducted in form of 10-fold cross validation with beat-based and record-based training schemes. Tested upon a total of 107049 beats from MIT-BIH arrhythmia database, our method has achieved average sensitivity, specificity and accuracy of 99.09%, 99.82% and 99.70%, respectively, using the beat-based training scheme, and 44.40%, 88.88% and 81.47%, respectively, using the record-based training scheme.
- 20 July 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 6067
Open AccessCombining Low-dimensional Wavelet Features and Support Vector Machine for Arrhythmia Beat Classification
Automatic feature extraction and classification are two main tasks in abnormal ECG beat recognition. Feature extraction is an important prerequisite prior to classification since it provides the classifier with input features, and the performance of classifier depends significantly on the quality of these features. This study develops an effective method to extract low-dimensional ECG beat feature vectors. It employs wavelet multi-resolution analysis to extract time-frequency domain features and then applies principle component analysis to reduce the dimension of the feature vector. In classification, 12-element feature vectors characterizing six types of beats are used as inputs for one-versus-one support vector machine, which is conducted in form of 10-fold cross validation with beat-based and record-based training schemes. Tested upon a total of 107049 beats from MIT-BIH arrhythmia database, our method has achieved average sensitivity, specificity and accuracy of 99.09%, 99.82% and 99.70%, respectively, using the beat-based training scheme, and 44.40%, 88.88% and 81.47%, respectively, using the record-based training scheme.