Titus Oluwasuji Ajewole
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Titus Oluwasuji Ajewole has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Olakunle Elijah Olabode
Department of Electrical and Information Engineering, Achievers University, Km. 1, Idasen/Uteh Road, P.M.B. 1030, Owo 341101, Ondo State, Nigeria
5 shared publications - Daniel Akinyele
Department of Electrical and Electronics Engineering, Olusegun Agagu University of Science and Technology, Okitipupa, Nigeria
4 shared publications - Ignatius Kema Okakwu
Olabisi Onabanjo University
4 shared publications Waheed Ayinla Oyekanmi
3 shared publicationsAbraham Amole
2 shared publications- Abraham Kehinde Aworinde
Department of Mechanical Engineering, Covenant University, Ota, Nigeria
2 shared publications
Latest Publications
- Open Access
- 7 October 2026
- Published byĀ Springer NatureĀ inĀ Cureus Journal of Engineering
- Vol.Ā 3 Ā (1)
Performance Assessment of a Solar Photovoltaic and Biogas Hybrid Renewable Energy System Under a Combined Dispatch Strategy
This study investigates the techno-economic and environmental performance of a hybrid renewable energy system integrating solar photovoltaic (PV), biogas, and battery storage for a large-scale abattoir in Lagos, Nigeria. Using HOMER Pro simulations, the research evaluates the effectiveness of a combined dispatch (CD) strategy that dynamically alternates between load-following and cycle-charging modes based on net load conditions and future load forecasting. The abattoirās baseline empirical daily energy consumption of 626.05 kWh/day was scaled to a design load of 2,426.4 kWh/day to simulate a robust and long-term operational expansion, which was matched against a solar irradiance of 4.74 kWh/m2/day and biomass recovery potential of approximately 15 tons/day. The results based on this scaled design load demonstrate that the CD strategy significantly outperformed the conventional cycle-charging (CC) approach, reducing the Net Present Cost by approximately 24.7% (a saving of $307,127) and lowering the cost of energy to $0.267/kWh. Furthermore, the CD strategy optimized the utilization of renewable resources, with PV contributing 68.7% of the energy mix, and enhanced equipment longevity by reducing the biogas generatorās annual run time from 3,178 hours to 1,194 hours. Environmentally, the CD strategy achieves a substantial reduction in COā emissions, emitting only 58.8 kg/yr compared to 152 kg/yr under the CC strategy. These findings highlight the viability of PV/biogas hybrid systems under optimized dispatch control as a sustainable and cost-effective energy solution for agro-industrial facilities in sub-Saharan Africa.
- 7 October 2026
- Published byĀ Springer NatureĀ inĀ Cureus Journal of Engineering
- Vol.Ā 3 Ā (1)
Open AccessPerformance Assessment of a Solar Photovoltaic and Biogas Hybrid Renewable Energy System Under a Combined Dispatch Strategy
This study investigates the techno-economic and environmental performance of a hybrid renewable energy system integrating solar photovoltaic (PV), biogas, and battery storage for a large-scale abattoir in Lagos, Nigeria. Using HOMER Pro simulations, the research evaluates the effectiveness of a combined dispatch (CD) strategy that dynamically alternates between load-following and cycle-charging modes based on net load conditions and future load forecasting. The abattoirās baseline empirical daily energy consumption of 626.05 kWh/day was scaled to a design load of 2,426.4 kWh/day to simulate a robust and long-term operational expansion, which was matched against a solar irradiance of 4.74 kWh/m2/day and biomass recovery potential of approximately 15 tons/day. The results based on this scaled design load demonstrate that the CD strategy significantly outperformed the conventional cycle-charging (CC) approach, reducing the Net Present Cost by approximately 24.7% (a saving of $307,127) and lowering the cost of energy to $0.267/kWh. Furthermore, the CD strategy optimized the utilization of renewable resources, with PV contributing 68.7% of the energy mix, and enhanced equipment longevity by reducing the biogas generatorās annual run time from 3,178 hours to 1,194 hours. Environmentally, the CD strategy achieves a substantial reduction in COā emissions, emitting only 58.8 kg/yr compared to 152 kg/yr under the CC strategy. These findings highlight the viability of PV/biogas hybrid systems under optimized dispatch control as a sustainable and cost-effective energy solution for agro-industrial facilities in sub-Saharan Africa.
- Open Access
- 16 July 2026
- Published byĀ ElsevierĀ inĀ Measurement: Energy
- Vol.Ā 11
Solution of multi-objective optimal power dispatch using NSGA-III for future reliability screening
- 16 July 2026
- Published byĀ ElsevierĀ inĀ Measurement: Energy
- Vol.Ā 11
Open AccessSolution of multi-objective optimal power dispatch using NSGA-III for future reliability screening
- Open Access
- 15 November 2025
- Published byĀ Osun State UniversityĀ inĀ Uniosun Journal of Engineering and Environmental Sciences
- Vol.Ā 1 Ā (1)
Teaching-Learning Based Optimization Approach for Determining Size and Location of Distributed Generation for Real Power Loss Reduction on Nigerian Grid
The ever increasing sensitization on the need for clean energies that are not only environmental friendly but also have comparative cost advantages encourages the use of distributed generation. Using distributed generation at the load ends or close to the load centers has not only reduced carbon emission, but also improves power system performances. Presented in this paper is the adoption of Teaching-Learning Based Optimization technique for determining the most suitable site and size of distributed generation for real power loss reduction on Nigerian power system. Backward/Forward Sweep technique was employed for the power flow analysis, while the suitable locations of the distributed generations were pre-selected using Voltage Stability Index and Teaching-Learning Based Optimization technique was employed to establish the optimal location and the optimum size of the required distributed generation. This approach was demonstrated on the IEEE 34-bus test system, with the placement of 1 kW DG at bus 11 of the system. The aggregate real power loss diminished from 571 kW to 208.5954 kW (63.5726% reduction), while Voltage Stability Index and voltage profile of the system also improved remarkably. Also, by placing distributed generation on typical Nigerian 11 kV feeder, the real power loss reduced from 1.1 kW to 0.75 kW while the magnitude of bus voltage increased from 0.8295 to 0.8456 p.u. Based on the results of this analysis, Teaching-Learning Based Optimization has demonstrated excellent performance on the two test cases and therefore would be a tool to adopt on the Nigerian radial distribution system.
- 15 November 2025
- Published byĀ Osun State UniversityĀ inĀ Uniosun Journal of Engineering and Environmental Sciences
- Vol.Ā 1 Ā (1)
Open AccessTeaching-Learning Based Optimization Approach for Determining Size and Location of Distributed Generation for Real Power Loss Reduction on Nigerian Grid
The ever increasing sensitization on the need for clean energies that are not only environmental friendly but also have comparative cost advantages encourages the use of distributed generation. Using distributed generation at the load ends or close to the load centers has not only reduced carbon emission, but also improves power system performances. Presented in this paper is the adoption of Teaching-Learning Based Optimization technique for determining the most suitable site and size of distributed generation for real power loss reduction on Nigerian power system. Backward/Forward Sweep technique was employed for the power flow analysis, while the suitable locations of the distributed generations were pre-selected using Voltage Stability Index and Teaching-Learning Based Optimization technique was employed to establish the optimal location and the optimum size of the required distributed generation. This approach was demonstrated on the IEEE 34-bus test system, with the placement of 1 kW DG at bus 11 of the system. The aggregate real power loss diminished from 571 kW to 208.5954 kW (63.5726% reduction), while Voltage Stability Index and voltage profile of the system also improved remarkably. Also, by placing distributed generation on typical Nigerian 11 kV feeder, the real power loss reduced from 1.1 kW to 0.75 kW while the magnitude of bus voltage increased from 0.8295 to 0.8456 p.u. Based on the results of this analysis, Teaching-Learning Based Optimization has demonstrated excellent performance on the two test cases and therefore would be a tool to adopt on the Nigerian radial distribution system.
- 28 August 2024
- Published byĀ IOP PublishingĀ inĀ Engineering Research Express
- Vol.Ā 6 Ā (3) , 035342
Strategic DG placement and sizing in developing nations' power systems using ISNT and modified forward-backward sweep
The power sector in many developing nations faces challenges in meeting consumersā demands for a reliable electricity supply due to increased load demand, primarily driven by population growth. Urban areas receive 24 h power, while extensive losses within the system limit coverage. Setting up centralised stations offers a temporary solution, but the capacity of the ageing transmission lines is uncertain. This study proposes integrating distributed generators (DG) into the power system, using Inherent Structural Network Topology (ISNT) for DG siting and a modified Forward-Backward Sweep model for sizing. Voltage Stability Index (VPI) assesses network stability. The model considers voltage profile and line losses, optimizing DG sites and sizes. Results demonstrate the modelās efficacy, offering insights for optimal DG planning to minimize losses and enhance voltage profiles. The study informs power system engineers for future planning, aiding decisions on DG location and size, potentially reducing line losses and improving voltage profiles, thus assisting in network upgrades or expansions.
- 28 August 2024
- Published byĀ IOP PublishingĀ inĀ Engineering Research Express
- Vol.Ā 6 Ā (3) , 035342
Strategic DG placement and sizing in developing nations' power systems using ISNT and modified forward-backward sweep
The power sector in many developing nations faces challenges in meeting consumersā demands for a reliable electricity supply due to increased load demand, primarily driven by population growth. Urban areas receive 24 h power, while extensive losses within the system limit coverage. Setting up centralised stations offers a temporary solution, but the capacity of the ageing transmission lines is uncertain. This study proposes integrating distributed generators (DG) into the power system, using Inherent Structural Network Topology (ISNT) for DG siting and a modified Forward-Backward Sweep model for sizing. Voltage Stability Index (VPI) assesses network stability. The model considers voltage profile and line losses, optimizing DG sites and sizes. Results demonstrate the modelās efficacy, offering insights for optimal DG planning to minimize losses and enhance voltage profiles. The study informs power system engineers for future planning, aiding decisions on DG location and size, potentially reducing line losses and improving voltage profiles, thus assisting in network upgrades or expansions.
- Open Access
- 31 December 2023
- Published byĀ University of JohannesburgĀ inĀ Journal of Digital Food, Energy & Water Systems
- Vol.Ā 4 Ā (2)
Enhancing Load Prediction Accuracy using Optimized Support Vector Regression Models
This paper investigates the effect of Support Vector Regression hyperparameters optimization on electrical load prediction. Accurate and robust load prediction helps policy makers in the energy sector to make inform decision and reduce losses. To achieve this, Bayesian optimization technique was employed for the hyperparameters optimization which are then used for the load prediction. The hyperparameters are the regularization parameters and the epsilon. In addition, the effects of sliding window during the load prediction were also evaluated. The sliding window values were varied from 1 to 5. The results showed that the sliding window of 1 had the optimized hyperparameters with the best performing evaluation metrics of 0.01912 and 0.09493 for MSE and MAE respectively.
- 31 December 2023
- Published byĀ University of JohannesburgĀ inĀ Journal of Digital Food, Energy & Water Systems
- Vol.Ā 4 Ā (2)
Open AccessEnhancing Load Prediction Accuracy using Optimized Support Vector Regression Models
This paper investigates the effect of Support Vector Regression hyperparameters optimization on electrical load prediction. Accurate and robust load prediction helps policy makers in the energy sector to make inform decision and reduce losses. To achieve this, Bayesian optimization technique was employed for the hyperparameters optimization which are then used for the load prediction. The hyperparameters are the regularization parameters and the epsilon. In addition, the effects of sliding window during the load prediction were also evaluated. The sliding window values were varied from 1 to 5. The results showed that the sliding window of 1 had the optimized hyperparameters with the best performing evaluation metrics of 0.01912 and 0.09493 for MSE and MAE respectively.
- Open Access
- 31 December 2023
- Published byĀ University of JohannesburgĀ inĀ Journal of Digital Food, Energy & Water Systems
- Vol.Ā 4 Ā (2)
Neural Network Approach to Pitch Angle Control in Wind Energy Conversion Systems for Increased Power Generation
Presented in this study is an artificial intelligence approach to pitch angle control in wind turbines for the enhancement of the power generation efficiency of wind energy conversion systems. A two-input neural network model was developed and trained using backward propagation technique to adjust the pitch angle of the turbine in response to the speed of turbine generator and the rate of change of the speed. Ten-year real-life data on the wind speeds of a study location was used to validate the approach. It was found that the method performs well in controlling the mechanical power developed by the turbine above the turbineās rated wind speed, and with fast processing time. 44.44%improvement was achieved in the mechanical power developed by the turbine. The control approach is thus recommended for the effective management of wind energy conversion systems towards enhancing availability and reliability of electric power supply.
- 31 December 2023
- Published byĀ University of JohannesburgĀ inĀ Journal of Digital Food, Energy & Water Systems
- Vol.Ā 4 Ā (2)
Open AccessNeural Network Approach to Pitch Angle Control in Wind Energy Conversion Systems for Increased Power Generation
Presented in this study is an artificial intelligence approach to pitch angle control in wind turbines for the enhancement of the power generation efficiency of wind energy conversion systems. A two-input neural network model was developed and trained using backward propagation technique to adjust the pitch angle of the turbine in response to the speed of turbine generator and the rate of change of the speed. Ten-year real-life data on the wind speeds of a study location was used to validate the approach. It was found that the method performs well in controlling the mechanical power developed by the turbine above the turbineās rated wind speed, and with fast processing time. 44.44%improvement was achieved in the mechanical power developed by the turbine. The control approach is thus recommended for the effective management of wind energy conversion systems towards enhancing availability and reliability of electric power supply.
- 18 August 2023
- Published byĀ Taylor & Francis
- p. 25-65
Overview and comparative application of on-grid and off-grid renewable energy systems in modern-day electrical power technology
The relevance and application of renewable energy (RE) technologies in electrical power systems continue to spread across the globe. This development is occasioned by a growing global load demand, the need to embrace an eco-friendly energy supply to mitigate the issues of global warming and climate change, and the concerted efforts to combat energy poverty in some developing countries, i.e., to improve electrification access rates. This chapter, therefore, introduces interesting perspectives on the various applications of renewable energies in electrical systems. Firstly, it presents the overview of inherent features, characteristics, and limitations of RE to aid the understanding of how they may be harnessed for energy generation or grid support purposes. One of these is the issue of the intermittency of RE sources; this is followed by the idea of hybrid or multi-energy sources for reliability purposes. Secondly, the chapter examines different configurations of RE systems such as on-grid and off-grid applications, which showcase whether or not the energy systems considered have an interaction with the existing grid and how the intended users are served. Thirdly, different electrical topologies of RE applications are presented and compared in conjunction with other important components such as storage devices, power electronic converters, and possibly a conventional resource. These include autonomous, backup, grid-tie, and grid-parallel power applications. This chapter provides useful insights into the use of RE resources to produce and manage power.
- 18 August 2023
- Published byĀ Taylor & Francis
- p. 25-65
Overview and comparative application of on-grid and off-grid renewable energy systems in modern-day electrical power technology
The relevance and application of renewable energy (RE) technologies in electrical power systems continue to spread across the globe. This development is occasioned by a growing global load demand, the need to embrace an eco-friendly energy supply to mitigate the issues of global warming and climate change, and the concerted efforts to combat energy poverty in some developing countries, i.e., to improve electrification access rates. This chapter, therefore, introduces interesting perspectives on the various applications of renewable energies in electrical systems. Firstly, it presents the overview of inherent features, characteristics, and limitations of RE to aid the understanding of how they may be harnessed for energy generation or grid support purposes. One of these is the issue of the intermittency of RE sources; this is followed by the idea of hybrid or multi-energy sources for reliability purposes. Secondly, the chapter examines different configurations of RE systems such as on-grid and off-grid applications, which showcase whether or not the energy systems considered have an interaction with the existing grid and how the intended users are served. Thirdly, different electrical topologies of RE applications are presented and compared in conjunction with other important components such as storage devices, power electronic converters, and possibly a conventional resource. These include autonomous, backup, grid-tie, and grid-parallel power applications. This chapter provides useful insights into the use of RE resources to produce and manage power.
- 18 August 2023
- Published byĀ Taylor & Francis
- p. 67-103
Conceptual perspective of renewable energy resources
Across the globe, a significant portion of the worldās energy generation comes from the combustion of fossil fuel materials whose by-products are responsible for the worldās climate change. Globally, climate change has significantly affected the existence of humanity in recent times. As a result, there has been a paradigm shift in the way humanity perceives the immediate environment. Adoption of renewable energy resources (RES) offers the benefit of eco-friendliness in the form of low carbon footprints. Therefore, there must be deliberate and concerted efforts in the utilization of RES to combat climate change. This chapter thus focuses on the factors capable of triggering climate change by providing a conceptual review of the available RES with an emphasis on the carbon footprint, and proffers possible pathways for mitigating the release of greenhouse gases (GHGs) into the atmosphere. The potential of biomass energy and small hydropower systems for sustainable community-based energy generation are also put forward. The chapter also takes special cognizance of powering municipal transportation by RES, as a potential means of curtailing GHG emissions from automobiles. Emphasis is equally placed on carbon capture, and utilization and storage techniques. It is hoped that a large number of the targeted audience will find the chapter handy and educative.
- 18 August 2023
- Published byĀ Taylor & Francis
- p. 67-103
Conceptual perspective of renewable energy resources
Across the globe, a significant portion of the worldās energy generation comes from the combustion of fossil fuel materials whose by-products are responsible for the worldās climate change. Globally, climate change has significantly affected the existence of humanity in recent times. As a result, there has been a paradigm shift in the way humanity perceives the immediate environment. Adoption of renewable energy resources (RES) offers the benefit of eco-friendliness in the form of low carbon footprints. Therefore, there must be deliberate and concerted efforts in the utilization of RES to combat climate change. This chapter thus focuses on the factors capable of triggering climate change by providing a conceptual review of the available RES with an emphasis on the carbon footprint, and proffers possible pathways for mitigating the release of greenhouse gases (GHGs) into the atmosphere. The potential of biomass energy and small hydropower systems for sustainable community-based energy generation are also put forward. The chapter also takes special cognizance of powering municipal transportation by RES, as a potential means of curtailing GHG emissions from automobiles. Emphasis is equally placed on carbon capture, and utilization and storage techniques. It is hoped that a large number of the targeted audience will find the chapter handy and educative.
- Open Access
- 1 February 2023
- Published byĀ Penerbit UTM PressĀ inĀ Journal of Energy and Safety Technology (JEST)
- Vol.Ā 5 Ā (2) , 1-14
Security Study on Freestanding Minigrid with Multiple Rotary Energy Sources
Traditional grid has been extensively studied for system security. For freestanding renewable energy-based minigrid, a three-source stand-alone minigrid is in this study examined for system security under large disturbances. By real-time simulation, rotor responses of the generators and voltage characteristics of the buses are assessed at sudden load change and under fault condition. Post-perturbation behaviour of the system shows synchronism is not compromised by any of the generators and the bus voltage profiles remains within their pre-perturbation statutory limits. This implies that a number of rotating machine-based energy mini-sources could be interconnected into a freestanding minigrid without compromising the stability of the system. The assessment could find use in predictive and corrective compensation for stability issues in mini integrated power systems and serve as simple generic investigative approach that could be integrated into Minigrids Remedial Action Scheme or Minigrids Energy Management System for dynamic security assessment of multi-machine island minigrids.
- 1 February 2023
- Published byĀ Penerbit UTM PressĀ inĀ Journal of Energy and Safety Technology (JEST)
- Vol.Ā 5 Ā (2) , 1-14
Open AccessSecurity Study on Freestanding Minigrid with Multiple Rotary Energy Sources
Traditional grid has been extensively studied for system security. For freestanding renewable energy-based minigrid, a three-source stand-alone minigrid is in this study examined for system security under large disturbances. By real-time simulation, rotor responses of the generators and voltage characteristics of the buses are assessed at sudden load change and under fault condition. Post-perturbation behaviour of the system shows synchronism is not compromised by any of the generators and the bus voltage profiles remains within their pre-perturbation statutory limits. This implies that a number of rotating machine-based energy mini-sources could be interconnected into a freestanding minigrid without compromising the stability of the system. The assessment could find use in predictive and corrective compensation for stability issues in mini integrated power systems and serve as simple generic investigative approach that could be integrated into Minigrids Remedial Action Scheme or Minigrids Energy Management System for dynamic security assessment of multi-machine island minigrids.
- Open Access
- 31 December 2022
- Published byĀ University of Dar es Salaam - DIGITAL COMMONS JOURNALSĀ inĀ Tanzania Journal of Engineering and Technology
- Vol.Ā 41 Ā (4) , 192-204
A Genetic Algorithm Approach to Optimal Sizing and Placement of Distributed Generation on Nigerian Radial Feeders
Mitigating power loss and voltage profile problems on radial distribution networks has been a major challenge to distribution system operators. While deployment of distributed generation, as compensators, has made a suitable solution option, optimum placement and sizing of the compensators has been a concern and it has thus been receiving great attention. Meta-heuristic algorithms have been found efficacious in this respect, yet the use of the algorithms in addressing problems of radial feeders is still comparatively low in Nigeria where analytical and numerical programming methods are common. Hence; the use of genetic algorithm to site and size distributed generator for real-time power loss reduction and voltage profile improvement on the Nigerian secondary distribution networks is presented. Backward-forward sweep load flow analysis, together with loss sensitivity factor, is deployed to identify the buses suitable for the installation of the distributed generation, while the algorithm is employed in estimating the optimum size. This approach is tested on the standard IEEE 15-bus system and validated using a Nigerian 11 kV feeder. The result obtained on the IEEE test system shows 183 kW loss using the compensator, as compared to 436 kW loss without the compensator; while on the Nigerian network the loss with the compensator was 4.99 kW, in comparison with no-compensation loss of 10.47kW. By the approach of this study, real power loss on the Nigerian feeder decreased by 52.3% together with energy cost reduction from N658,789.12 to N314,227.38. Likewise the minimum bus voltage magnitude and the voltage stability index of the network are improved to acceptable limits. This approach is therefore recommended as capable of strengthening the performance of the Nigerian radial distribution system.
- 31 December 2022
- Published byĀ University of Dar es Salaam - DIGITAL COMMONS JOURNALSĀ inĀ Tanzania Journal of Engineering and Technology
- Vol.Ā 41 Ā (4) , 192-204
Open AccessA Genetic Algorithm Approach to Optimal Sizing and Placement of Distributed Generation on Nigerian Radial Feeders
Mitigating power loss and voltage profile problems on radial distribution networks has been a major challenge to distribution system operators. While deployment of distributed generation, as compensators, has made a suitable solution option, optimum placement and sizing of the compensators has been a concern and it has thus been receiving great attention. Meta-heuristic algorithms have been found efficacious in this respect, yet the use of the algorithms in addressing problems of radial feeders is still comparatively low in Nigeria where analytical and numerical programming methods are common. Hence; the use of genetic algorithm to site and size distributed generator for real-time power loss reduction and voltage profile improvement on the Nigerian secondary distribution networks is presented. Backward-forward sweep load flow analysis, together with loss sensitivity factor, is deployed to identify the buses suitable for the installation of the distributed generation, while the algorithm is employed in estimating the optimum size. This approach is tested on the standard IEEE 15-bus system and validated using a Nigerian 11 kV feeder. The result obtained on the IEEE test system shows 183 kW loss using the compensator, as compared to 436 kW loss without the compensator; while on the Nigerian network the loss with the compensator was 4.99 kW, in comparison with no-compensation loss of 10.47kW. By the approach of this study, real power loss on the Nigerian feeder decreased by 52.3% together with energy cost reduction from N658,789.12 to N314,227.38. Likewise the minimum bus voltage magnitude and the voltage stability index of the network are improved to acceptable limits. This approach is therefore recommended as capable of strengthening the performance of the Nigerian radial distribution system.