Shuhei Kaneko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shuhei Kaneko has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Shigemitsu Okabe
R & D Center, High Voltage & Insulation Group, Tokyo Electric Power Company Limited, Yokohama, Kanagawa, Japan
3 shared publications- Yasunori Tanaka
Institute of Science and Engineering, Kanazawa University, Kakuma, Kanazawa 920-1192, Japan
2 shared publications - Akihiro Hirakawa
Department of Clinical Biostatistics, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo 113-8510, Japan
1 shared publication Chikuma Hamada
Department of Management Science, Graduate School of Engineering, Tokyo University of Science, 1-3 Kagurazaka, Shinjuku-ku, Tokyo 162-8601, Japan
1 shared publicationF. Kato
Department of EEBS, Waseda University, 3-4-1 Ohkubo, Shinjuku-ku, Tokyo 169-8555, Japan
1 shared publicationMasatoyo Shibuya
Central Research Institute of Electric Power Industry
1 shared publication
Latest Publications
- Open Access
- 3 June 2015
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2015, 1-7
Enhancing the Lasso Approach for Developing a Survival Prediction Model Based on Gene Expression Data
In the past decade, researchers in oncology have sought to develop survival prediction models using gene expression data. The least absolute shrinkage and selection operator (lasso) has been widely used to select genes that truly correlated with a patient’s survival. The lasso selects genes for prediction by shrinking a large number of coefficients of the candidate genes towards zero based on a tuning parameter that is often determined by a cross-validation (CV). However, this method can pass over (or fail to identify) true positive genes (i.e., it identifies false negatives) in certain instances, because the lasso tends to favor the development of a simple prediction model. Here, we attempt to monitor the identification of false negatives by developing a method for estimating the number of true positive (TP) genes for a series of values of a tuning parameter that assumes a mixture distribution for the lasso estimates. Using our developed method, we performed a simulation study to examine its precision in estimating the number of TP genes. Additionally, we applied our method to a real gene expression dataset and found that it was able to identify genes correlated with survival that a CV method was unable to detect.
- 3 June 2015
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2015, 1-7
Open AccessEnhancing the Lasso Approach for Developing a Survival Prediction Model Based on Gene Expression Data
In the past decade, researchers in oncology have sought to develop survival prediction models using gene expression data. The least absolute shrinkage and selection operator (lasso) has been widely used to select genes that truly correlated with a patient’s survival. The lasso selects genes for prediction by shrinking a large number of coefficients of the candidate genes towards zero based on a tuning parameter that is often determined by a cross-validation (CV). However, this method can pass over (or fail to identify) true positive genes (i.e., it identifies false negatives) in certain instances, because the lasso tends to favor the development of a simple prediction model. Here, we attempt to monitor the identification of false negatives by developing a method for estimating the number of true positive (TP) genes for a series of values of a tuning parameter that assumes a mixture distribution for the lasso estimates. Using our developed method, we performed a simulation study to examine its precision in estimating the number of TP genes. Additionally, we applied our method to a real gene expression dataset and found that it was able to identify genes correlated with survival that a CV method was unable to detect.
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 542-545
Effects of blending various biodegradable polymer plasticizers on the conduction current and AC breakdown strength in starch ester
Biodegradable polymer plasticizers, polycaprolactone (PCL) and polybutylene succinate adipate (PBSA) were blended with starch ester (SE), and their thermal properties and dielectric properties such as electrical conductivity, complex permittivity, and AC breakdown strength were examined. As a result, it has become clear that SE blends with PCL and PBSA can be used as electrical insulating materials at low voltages.
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 542-545
Effects of blending various biodegradable polymer plasticizers on the conduction current and AC breakdown strength in starch ester
Biodegradable polymer plasticizers, polycaprolactone (PCL) and polybutylene succinate adipate (PBSA) were blended with starch ester (SE), and their thermal properties and dielectric properties such as electrical conductivity, complex permittivity, and AC breakdown strength were examined. As a result, it has become clear that SE blends with PCL and PBSA can be used as electrical insulating materials at low voltages.
- 7 February 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 15 (1) , 243-250
Effect of electrode surface roughness and dielectric coating on breakdown characteristics of high pressure CO2 and N2 in a quasi-uniform electric field
SF6 gas has excellent dielectric strength and interrupting capability and is used in various applications such as gas insulated switchgear (GIS) in substations. However, since SF6 has a high global warming potential (GWP), it is imperative to reduce its use and develop recovery technology for its reuse. This paper examined the potential of alternative insulating gases for GIS, determining experimentally the ac and lightning impulse breakdown characteristics of CO2 and N2 gases, which have little environmental impact, in a quasi-uniform electric field. The effect of electrode surface roughness is greater in N2 than in CO2. The impulse ratio in a quasi-uniform electric field was smaller in N2 than in CO2 at low pressure, but this reversed when the pressure reached 1.2 MPa. The dielectric strength of an electrode with a dielectric coating was approximately equal to that of a specular-finish bare electrode in either CO2 or N2 when an ac voltage was applied. When lightning impulse voltage was applied, a significant improvement of dielectric strength was observed if a dielectric coating was applied to the electrode considered to be the initial electron source.
- 7 February 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 15 (1) , 243-250
Effect of electrode surface roughness and dielectric coating on breakdown characteristics of high pressure CO2 and N2 in a quasi-uniform electric field
SF6 gas has excellent dielectric strength and interrupting capability and is used in various applications such as gas insulated switchgear (GIS) in substations. However, since SF6 has a high global warming potential (GWP), it is imperative to reduce its use and develop recovery technology for its reuse. This paper examined the potential of alternative insulating gases for GIS, determining experimentally the ac and lightning impulse breakdown characteristics of CO2 and N2 gases, which have little environmental impact, in a quasi-uniform electric field. The effect of electrode surface roughness is greater in N2 than in CO2. The impulse ratio in a quasi-uniform electric field was smaller in N2 than in CO2 at low pressure, but this reversed when the pressure reached 1.2 MPa. The dielectric strength of an electrode with a dielectric coating was approximately equal to that of a specular-finish bare electrode in either CO2 or N2 when an ac voltage was applied. When lightning impulse voltage was applied, a significant improvement of dielectric strength was observed if a dielectric coating was applied to the electrode considered to be the initial electron source.
- Open Access
- 1 January 2007
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 127 (6) , 739-746
Numerical Simulation of Thermal Interaction between Polymer and Ar Induction Thermal Plasma
- 1 January 2007
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 127 (6) , 739-746
Open AccessNumerical Simulation of Thermal Interaction between Polymer and Ar Induction Thermal Plasma
- Open Access
- 1 January 2006
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 126 (1) , 80-90
Thermodynamic and Transport Properties of CO2, CO2-O2 and CO2-H2 Mixtures at Temperatures of 300-30,000 K and at Pressures of 0.1-10 MPa
- 1 January 2006
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 126 (1) , 80-90
Open AccessThermodynamic and Transport Properties of CO2, CO2-O2 and CO2-H2 Mixtures at Temperatures of 300-30,000 K and at Pressures of 0.1-10 MPa