Massimo Camplani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Massimo Camplani has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
- Luis Salgado
Universidad Politécnica de Madrid
16 shared publications - Majid Mirmehdi
University of Bristol
7 shared publications - Dima Damen
University of Bristol, Bristol, UK
6 shared publications B. Cannas
University of Cagliari
5 shared publications- Adeline Paiement
Université de Toulon, Aix Marseille Univ, CNRS, LIS, Marseille, France
4 shared publications A. Fanni
University of Cagliari
3 shared publications
Latest Publications
- Open Access
- 23 March 2023
- Published by Springer Nature in Scientific Data
- Vol. 10 (1) , 1-15
A multi-sensor dataset with annotated activities of daily living recorded in a residential setting
SPHERE is a large multidisciplinary project to research and develop a sensor network to facilitate home healthcare by activity monitoring, specifically towards activities of daily living. It aims to use the latest technologies in low powered sensors, internet of things, machine learning and automated decision making to provide benefits to patients and clinicians. This dataset comprises data collected from a SPHERE sensor network deployment during a set of experiments conducted in the ‘SPHERE House’ in Bristol, UK, during 2016, including video tracking, accelerometer and environmental sensor data obtained by volunteers undertaking both scripted and non-scripted activities of daily living in a domestic residence. Trained annotators provided ground-truth labels annotating posture, ambulation, activity and location. This dataset is a valuable resource both within and outside the machine learning community, particularly in developing and evaluating algorithms for identifying activities of daily living from multi-modal sensor data in real-world environments. A subset of this dataset was released as a machine learning competition in association with the European Conference on Machine Learning (ECML-PKDD 2016).
- 23 March 2023
- Published by Springer Nature in Scientific Data
- Vol. 10 (1) , 1-15
Open AccessA multi-sensor dataset with annotated activities of daily living recorded in a residential setting
SPHERE is a large multidisciplinary project to research and develop a sensor network to facilitate home healthcare by activity monitoring, specifically towards activities of daily living. It aims to use the latest technologies in low powered sensors, internet of things, machine learning and automated decision making to provide benefits to patients and clinicians. This dataset comprises data collected from a SPHERE sensor network deployment during a set of experiments conducted in the ‘SPHERE House’ in Bristol, UK, during 2016, including video tracking, accelerometer and environmental sensor data obtained by volunteers undertaking both scripted and non-scripted activities of daily living in a domestic residence. Trained annotators provided ground-truth labels annotating posture, ambulation, activity and location. This dataset is a valuable resource both within and outside the machine learning community, particularly in developing and evaluating algorithms for identifying activities of daily living from multi-modal sensor data in real-world environments. A subset of this dataset was released as a machine learning competition in association with the European Conference on Machine Learning (ECML-PKDD 2016).
- Open Access
- 1 July 2016
- Published by Elsevier in Computer Vision and Image Understanding
- Vol. 148, 136-152
A comparative study of pose representation and dynamics modelling for online motion quality assessment
- 1 July 2016
- Published by Elsevier in Computer Vision and Image Understanding
- Vol. 148, 136-152
Open AccessA comparative study of pose representation and dynamics modelling for online motion quality assessment
- Open Access
- 1 January 2016
- Published by Institution of Engineering and Technology (IET)
- p. 11 (6 .)
Real-time Estimation of Physical Activity Intensity for Daily Living
Estimating a person's energy expenditure and activity intensity over time is an important component in managing various health conditions or tracking lifestyle choices. To implement an automatic estimation, most current systems ultimately require users to wear sensor devices. In contrast, this paper presents a framework for the contact-free, real-time estimation of energy expenditure, applicable to daily living scenarios. This is a new application in real-time computer vision. We demonstrate the effectiveness and the benefits of utilising a basic set of features and evaluate the resulting framework on the challenging SPHERE-calorie dataset. To ensure accurate evaluation, automated estimates are compared against a simultaneously taken indirect calorimetry ground truth based on per breath gas exchange. Following detailed experiments, we conclude that the proposed real-time vision pipeline is suitable for monitoring physical activity levels in a controlled environment with higher accuracy than the commonly used manual estimation via metabolic lookup tables (METs), whilst being significantly faster than existing automated methods.
- 1 January 2016
- Published by Institution of Engineering and Technology (IET)
- p. 11 (6 .)
Open AccessReal-time Estimation of Physical Activity Intensity for Daily Living
Estimating a person's energy expenditure and activity intensity over time is an important component in managing various health conditions or tracking lifestyle choices. To implement an automatic estimation, most current systems ultimately require users to wear sensor devices. In contrast, this paper presents a framework for the contact-free, real-time estimation of energy expenditure, applicable to daily living scenarios. This is a new application in real-time computer vision. We demonstrate the effectiveness and the benefits of utilising a basic set of features and evaluate the resulting framework on the challenging SPHERE-calorie dataset. To ensure accurate evaluation, automated estimates are compared against a simultaneously taken indirect calorimetry ground truth based on per breath gas exchange. Following detailed experiments, we conclude that the proposed real-time vision pipeline is suitable for monitoring physical activity levels in a controlled environment with higher accuracy than the commonly used manual estimation via metabolic lookup tables (METs), whilst being significantly faster than existing automated methods.
- 1 January 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (1) , 013504
Image computing techniques to extrapolate data for dust tracking in case of an experimental accident simulation in a nuclear fusion plant
In this paper, a preliminary shadowgraph-based analysis of dust particles re-suspension due to loss of vacuum accident (LOVA) in ITER-like nuclear fusion reactors has been presented. Dust particles are produced through different mechanisms in nuclear fusion devices, one of the main issues is that dust particles are capable of being re-suspended in case of events such as LOVA. Shadowgraph is based on an expanded collimated beam of light emitted by a laser or a lamp that emits light transversely compared to the flow field direction. In the STARDUST facility, the dust moves in the flow, and it causes variations of refractive index that can be detected by using a CCD camera. The STARDUST fast camera setup allows to detect and to track dust particles moving in the vessel and then to obtain information about the velocity field of dust mobilized. In particular, the acquired images are processed such that per each frame the moving dust particles are detected by applying a background subtraction technique based on the mixture of Gaussian algorithm. The obtained foreground masks are eventually filtered with morphological operations. Finally, a multi-object tracking algorithm is used to track the detected particles along the experiment. For each particle, a Kalman filter-based tracker is applied; the particles dynamic is described by taking into account position, velocity, and acceleration as state variable. The results demonstrate that it is possible to obtain dust particles’ velocity field during LOVA by automatically processing the data obtained with the shadowgraph approach.
- 1 January 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (1) , 013504
Image computing techniques to extrapolate data for dust tracking in case of an experimental accident simulation in a nuclear fusion plant
In this paper, a preliminary shadowgraph-based analysis of dust particles re-suspension due to loss of vacuum accident (LOVA) in ITER-like nuclear fusion reactors has been presented. Dust particles are produced through different mechanisms in nuclear fusion devices, one of the main issues is that dust particles are capable of being re-suspended in case of events such as LOVA. Shadowgraph is based on an expanded collimated beam of light emitted by a laser or a lamp that emits light transversely compared to the flow field direction. In the STARDUST facility, the dust moves in the flow, and it causes variations of refractive index that can be detected by using a CCD camera. The STARDUST fast camera setup allows to detect and to track dust particles moving in the vessel and then to obtain information about the velocity field of dust mobilized. In particular, the acquired images are processed such that per each frame the moving dust particles are detected by applying a background subtraction technique based on the mixture of Gaussian algorithm. The obtained foreground masks are eventually filtered with morphological operations. Finally, a multi-object tracking algorithm is used to track the detected particles along the experiment. For each particle, a Kalman filter-based tracker is applied; the particles dynamic is described by taking into account position, velocity, and acceleration as state variable. The results demonstrate that it is possible to obtain dust particles’ velocity field during LOVA by automatically processing the data obtained with the shadowgraph approach.
- Open Access
P83 Remote pulmonary function testing – computer gaming in the respiratory world
Introduction Lung function testing by spirometry has remained unchanged for over 50 years, despite limitations including patient technique, discomfort, cost and training. Non-invasive, remote lung volume measurement is an alternative approach. This has been explored in the past using structured light, accelerometers and impedance pneumography, but these have often been costly and of limited validity. We use a novel approach to remote assessment (~2 metres) using a 3D time-of-flight depth camera – similar to those found in many home gaming consoles. This pilot developmental data was generated from patients in a clinical setting. Methods Patients were recruited from a general respiratory physiology laboratory. Spirometry was performed according to ATS/ERS standards using an unmodified pneumotachograph (nSpire Health, Longmont, CO, USA). A Kinect V2 time-of-flight depth sensor (Microsoft, Redmond, WA, USA) was used to reconstruct 3D models of the subject’s thorax to estimate volume-time and flow-time curves for both Forced and Slow Vital Capacity and their associated measurements (Figure 1, technical details in1). (A) Reconstructed chest surface and volume estimation from reference plane. (B) Volume-time curves (FVC and SVC) comparing spirometer values and Kinect calculation These results were correlated with simultaneous recordings from the pneumotachograph, and error values calculated to assess the accuracy of the technique. Results Data were available from 53 patients, with 40 having usable data. Mean age 62.8 yrs (SD 16.2), BMI of 26.8 (SD 5.5). 41.5% male. 54.7% of patients had obstructive lung diseases, and 28.4% fibrotic lung disease. Mean FVC was 91.3% predicted (SD 26.4%), Mean FEV1 83.1% (SD 28.9%). The model estimates were highly correlated with spirometric values for FVC (λ = 0.999), FEV1 (λ = 0.947), VC (λ = 0.999), IC (λ = 0.997) and TV (λ = 0.962). Univariate analysis demonstrated no patient characteristics predictive of discrepancy from spirometric values for FVC or VC. Conclusions We describe a pilot data from the initial development of a new technique for non-invasively assessing lung volume and pulmonary function measurements. It correlates to within 30 ml for FVC and 10 ml for VC. This has a wide range of potential applications, including screening, home monitoring of respiratory disease, assessment of lung function in those unable to complete pneumotachygraphy and gating controls for radiological imaging techniques. Reference 1 Soleimani V, Mirmehdi M, Damen D, et al. Remote pulmonary function testing using a depth sensor. Biocas 2015
Open AccessP83 Remote pulmonary function testing – computer gaming in the respiratory world
Introduction Lung function testing by spirometry has remained unchanged for over 50 years, despite limitations including patient technique, discomfort, cost and training. Non-invasive, remote lung volume measurement is an alternative approach. This has been explored in the past using structured light, accelerometers and impedance pneumography, but these have often been costly and of limited validity. We use a novel approach to remote assessment (~2 metres) using a 3D time-of-flight depth camera – similar to those found in many home gaming consoles. This pilot developmental data was generated from patients in a clinical setting. Methods Patients were recruited from a general respiratory physiology laboratory. Spirometry was performed according to ATS/ERS standards using an unmodified pneumotachograph (nSpire Health, Longmont, CO, USA). A Kinect V2 time-of-flight depth sensor (Microsoft, Redmond, WA, USA) was used to reconstruct 3D models of the subject’s thorax to estimate volume-time and flow-time curves for both Forced and Slow Vital Capacity and their associated measurements (Figure 1, technical details in1). (A) Reconstructed chest surface and volume estimation from reference plane. (B) Volume-time curves (FVC and SVC) comparing spirometer values and Kinect calculation These results were correlated with simultaneous recordings from the pneumotachograph, and error values calculated to assess the accuracy of the technique. Results Data were available from 53 patients, with 40 having usable data. Mean age 62.8 yrs (SD 16.2), BMI of 26.8 (SD 5.5). 41.5% male. 54.7% of patients had obstructive lung diseases, and 28.4% fibrotic lung disease. Mean FVC was 91.3% predicted (SD 26.4%), Mean FEV1 83.1% (SD 28.9%). The model estimates were highly correlated with spirometric values for FVC (λ = 0.999), FEV1 (λ = 0.947), VC (λ = 0.999), IC (λ = 0.997) and TV (λ = 0.962). Univariate analysis demonstrated no patient characteristics predictive of discrepancy from spirometric values for FVC or VC. Conclusions We describe a pilot data from the initial development of a new technique for non-invasively assessing lung volume and pulmonary function measurements. It correlates to within 30 ml for FVC and 10 ml for VC. This has a wide range of potential applications, including screening, home monitoring of respiratory disease, assessment of lung function in those unable to complete pneumotachygraphy and gating controls for radiological imaging techniques. Reference 1 Soleimani V, Mirmehdi M, Damen D, et al. Remote pulmonary function testing using a depth sensor. Biocas 2015
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 644-647
A comparative home activity monitoring study using visual and inertial sensors
Monitoring actions at home can provide essential information for rehabilitation management. This paper presents a comparative study and a dataset for the fully automated, sample-accurate recognition of common home actions in the living room environment using commercial-grade, inexpensive inertial and visual sensors. We investigate the practical home-use of body-worn mobile phone inertial sensors together with an Asus Xmotion RGB-Depth camera to achieve monitoring of daily living scenarios. To test this setup against realistic data, we introduce the challenging SPHERE-H130 action dataset containing 130 sequences of 13 household actions recorded in a home environment. We report automatic recognition results at maximal temporal resolution, which indicate that a vision-based approach outperforms accelerometer provided by two phone-based inertial sensors by an average of 14.85% accuracy for home actions. Further, we report improved accuracy of a vision-based approach over accelerometry on particularly challenging actions as well as when generalising across subjects.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 644-647
A comparative home activity monitoring study using visual and inertial sensors
Monitoring actions at home can provide essential information for rehabilitation management. This paper presents a comparative study and a dataset for the fully automated, sample-accurate recognition of common home actions in the living room environment using commercial-grade, inexpensive inertial and visual sensors. We investigate the practical home-use of body-worn mobile phone inertial sensors together with an Asus Xmotion RGB-Depth camera to achieve monitoring of daily living scenarios. To test this setup against realistic data, we introduce the challenging SPHERE-H130 action dataset containing 130 sequences of 13 household actions recorded in a home environment. We report automatic recognition results at maximal temporal resolution, which indicate that a vision-based approach outperforms accelerometer provided by two phone-based inertial sensors by an average of 14.85% accuracy for home actions. Further, we report improved accuracy of a vision-based approach over accelerometry on particularly challenging actions as well as when generalising across subjects.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Remote pulmonary function testing using a depth sensor
We propose a remote non-invasive approach to Pulmonary Function Testing using a time-of-flight depth sensor (Microsoft Kinect V2), and correlate our results to clinical-standard spirometry results. Given point clouds, we approximate 3D models of the subject's chest, estimate the volume throughout a sequence and construct volume-time and flow-time curves for two prevalent spirometry tests: Forced Vital Capacity and Slow Vital Capacity. From these, we compute clinical measures, such as FVC, FEV1, VC and IC. We correlate automatically extracted measures with clinical spirometry tests on 40 patients in an outpatient hospital setting. These demonstrate high within-test correlations.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Remote pulmonary function testing using a depth sensor
We propose a remote non-invasive approach to Pulmonary Function Testing using a time-of-flight depth sensor (Microsoft Kinect V2), and correlate our results to clinical-standard spirometry results. Given point clouds, we approximate 3D models of the subject's chest, estimate the volume throughout a sequence and construct volume-time and flow-time curves for two prevalent spirometry tests: Forced Vital Capacity and Slow Vital Capacity. From these, we compute clinical measures, such as FVC, FEV1, VC and IC. We correlate automatically extracted measures with clinical spirometry tests on 40 patients in an outpatient hospital setting. These demonstrate high within-test correlations.
- Open Access
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Intelligent Systems
- Vol. 30 (4) , 39-46
Bridging e-Health and the Internet of Things: The SPHERE Project
There's a widely known need to revise current forms of healthcare provision. Of particular interest are sensing systems in the home, which have been central to several studies. This article presents an overview of this rapidly growing body of work, as well as the implications for machine learning, with an aim of uncovering the gap between the state of the art and the broad needs of healthcare services in ambient assisted living. Most approaches address specific healthcare concerns, which typically result in solutions that aren't able to support full-scale sensing and data analysis for a more generic healthcare service, but the approach in this article differs from seamlessly linking multimodel data-collecting infrastructure and data analytics together in an AAL platform. This article also outlines a multimodality sensor platform with heterogeneous network connectivity, which is under development in the sensor platform for healthcare in a residential environment (SPHERE) Interdisciplinary Research Collaboration (IRC).
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Intelligent Systems
- Vol. 30 (4) , 39-46
Open AccessBridging e-Health and the Internet of Things: The SPHERE Project
There's a widely known need to revise current forms of healthcare provision. Of particular interest are sensing systems in the home, which have been central to several studies. This article presents an overview of this rapidly growing body of work, as well as the implications for machine learning, with an aim of uncovering the gap between the state of the art and the broad needs of healthcare services in ambient assisted living. Most approaches address specific healthcare concerns, which typically result in solutions that aren't able to support full-scale sensing and data analysis for a more generic healthcare service, but the approach in this article differs from seamlessly linking multimodel data-collecting infrastructure and data analytics together in an AAL platform. This article also outlines a multimodality sensor platform with heterogeneous network connectivity, which is under development in the sensor platform for healthcare in a residential environment (SPHERE) Interdisciplinary Research Collaboration (IRC).
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21647038,p. 271-277
A multi-modal sensor infrastructure for healthcare in a residential environment
Ambient Assisted Living (AAL) systems based on sensor technologies are seen as key enablers to an ageing society. However, most approaches in this space do not provide a truly generic ambient space - one that is not only capable of assisting people with diverse medical conditions, but can also recognise the habits of healthy habitants, as well as those with developing medical conditions. The recognition of Activities of Daily Living (ADL) is key to the understanding and provisioning of appropriate and efficient care. However, ADL recognition is particularly difficult to achieve in multi-resident spaces; especially with single-mode (albeit carefully crafted) solutions, which only have limited capabilities. To address these limitations we propose a multi-modal system architecture for AAL remote healthcare monitoring in the home, gathering information from multiple, diverse (sensor) data sources. In this paper we report on developments made to-date in various technical areas with respect to critical issues such as cost, power consumption, scalability, interoperability and privacy.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21647038,p. 271-277
A multi-modal sensor infrastructure for healthcare in a residential environment
Ambient Assisted Living (AAL) systems based on sensor technologies are seen as key enablers to an ageing society. However, most approaches in this space do not provide a truly generic ambient space - one that is not only capable of assisting people with diverse medical conditions, but can also recognise the habits of healthy habitants, as well as those with developing medical conditions. The recognition of Activities of Daily Living (ADL) is key to the understanding and provisioning of appropriate and efficient care. However, ADL recognition is particularly difficult to achieve in multi-resident spaces; especially with single-mode (albeit carefully crafted) solutions, which only have limited capabilities. To address these limitations we propose a multi-modal system architecture for AAL remote healthcare monitoring in the home, gathering information from multiple, diverse (sensor) data sources. In this paper we report on developments made to-date in various technical areas with respect to critical issues such as cost, power consumption, scalability, interoperability and privacy.
- Open Access
- 1 January 2015
- Published by Elsevier in Physics Procedia
- Vol. 62, 97-101
Shadowgraph Technique Applied to STARDUST Facility for Dust Tracking: First Results
- 1 January 2015
- Published by Elsevier in Physics Procedia
- Vol. 62, 97-101
Open AccessShadowgraph Technique Applied to STARDUST Facility for Dust Tracking: First Results