WMWilliam D. Memberg

William D. Memberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


William D. Memberg has a total of 154 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Targeting grasp-related cortical areas for intracortical brain-machine interfaces

    by Tyler R. Johnson, Crispin Foli, Emily C. Conlan, Katherine A. Koenig, Mark J. Lowe, William D. Memberg, Robert F. Kirsch, Eric Z. Herring, Stanley F. Bazarek, Emily L. Graczyk, et al.


  • Open Access

    Bacteria invade the brain following intracortical microelectrode implantation, inducing gut-brain axis disruption and contributing to reduced microelectrode performance

    by George F. Hoeferlin, Sarah E. Grabinski, Lindsey N. Druschel, Jonathan L. Duncan, Grace Burkhart, Gwendolyn R. Weagraff, Alice H. Lee, Christopher Hong, Meera Bambroo, Hannah Olivares, et al.

    Brain-machine interface performance can be affected by neuroinflammatory responses due to blood-brain barrier (BBB) damage following intracortical microelectrode implantation. Recent findings suggest that certain gut bacterial constituents might enter the brain through damaged BBB. Therefore, we hypothesized that damage to the BBB caused by microelectrode implantation could facilitate microbiome entry into the brain. In our study, we found bacterial sequences, including gut-related ones, in the brains of mice with implanted microelectrodes. These sequences changed over time. Mice treated with antibiotics showed a reduced presence of these bacteria and had a different inflammatory response, which temporarily improved microelectrode recording performance. However, long-term antibiotic use worsened performance and disrupted neurodegenerative pathways. Many bacterial sequences found were not present in the gut or in unimplanted brains. Together, the current study established a paradigm-shifting mechanism that may contribute to chronic intracortical microelectrode recording performance and affect overall brain health following intracortical microelectrode implantation.


  • Reconnecting the Hand and Arm to the Brain: Efficacy of Neural Interfaces for Sensorimotor Restoration After Tetraplegia

    by Eric Z. Herring, Emily L. Graczyk, William D. Memberg, Robert Adams, Gaudalupe Fernandez Baca-Vaca, Brianna C. Hutchison, John T. Krall, Benjamin J. Alexander, Emily C. Conlan, Kenya E. Alfaro, et al.

    BACKGROUND AND OBJECTIVES: Paralysis after spinal cord injury involves damage to pathways that connect neurons in the brain to peripheral nerves in the limbs. Re-establishing this communication using neural interfaces has the potential to bridge the gap and restore upper extremity function to people with high tetraplegia. We report a novel approach for restoring upper extremity function using selective peripheral nerve stimulation controlled by intracortical microelectrode recordings from sensorimotor networks, along with restoration of tactile sensation of the hand using intracortical microstimulation. METHODS: A 27-year-old right-handed man with AIS-B (motor-complete, sensory-incomplete) C3–C4 tetraplegia was enrolled into the clinical trial. Six 64-channel intracortical microelectrode arrays were implanted into left hemisphere regions involved in upper extremity function, including primary motor and sensory cortices, inferior frontal gyrus, and anterior intraparietal area. Nine 16-channel extraneural peripheral nerve electrodes were implanted to allow targeted stimulation of right median, ulnar (2), radial, axillary, musculocutaneous, suprascapular, lateral pectoral, and long thoracic nerves, to produce selective muscle contractions on demand. Proof-of-concept studies were performed to demonstrate feasibility of using a brain-machine interface to read from and write to the brain for restoring motor and sensory functions of the participant's own arm and hand. RESULTS: Multiunit neural activity that correlated with intended motor action was successfully recorded from intracortical arrays. Microstimulation of electrodes in somatosensory cortex produced repeatable sensory percepts of individual fingers for restoration of touch sensation. Selective electrical activation of peripheral nerves produced antigravity muscle contractions, resulting in functional movements that the participant was able to command under brain control to perform virtual and actual arm and hand movements. The system was well tolerated with no operative complications. CONCLUSION: The combination of implanted cortical electrodes and nerve cuff electrodes has the potential to create bidirectional restoration of motor and sensory functions of the arm and hand after neurological injury.


  • Open Access

    The Neural Representation of Force across Grasp Types in Motor Cortex of Humans with Tetraplegia

    by Anisha Rastogi, Francis R. Willett, Jessica Abreu, Douglas C. Crowder, Brian A. Murphy, William D. Memberg, Carlos E. Vargas-Irwin, Jonathan P. Miller, Jennifer Sweet, Benjamin L. Walter, et al.

    Intracortical brain-computer interfaces (iBCIs) have the potential to restore hand grasping and object interaction to individuals with tetraplegia. Optimal grasping and object interaction require simultaneous production of both force and grasp outputs. However, since overlapping neural populations are modulated by both parameters, grasp type could affect how well forces are decoded from motor cortex in a closed-loop force iBCI. Therefore, this work quantified the neural representation and offline decoding performance of discrete hand grasps and force levels in two human participants with tetraplegia. Participants attempted to produce three discrete forces (light, medium, hard) using up to five hand grasp configurations. A two-way Welch ANOVA was implemented on multiunit neural features to assess their modulation to force and grasp. Demixed principal component analysis (dPCA) was used to assess for population-level tuning to force and grasp and to predict these parameters from neural activity. Three major findings emerged from this work: (1) force information was neurally represented and could be decoded across multiple hand grasps (and, in one participant, across attempted elbow extension as well); (2) grasp type affected force representation within multiunit neural features and offline force classification accuracy; and (3) grasp was classified more accurately and had greater population-level representation than force. These findings suggest that force and grasp have both independent and interacting representations within cortex, and that incorporating force control into real-time iBCI systems is feasible across multiple hand grasps if the decoder also accounts for grasp type.


  • Open Access

    The neural representation of force across grasp types in motor cortex of humans with tetraplegia

    by Anisha Rastogi, Francis R. Willett, Jessica Abreu, Douglas Cale Crowder, Brian A. Murphy, William D. Memberg, Carlos E. Vargas-Irwin, Jonathan P. Miller, Jennifer Sweet, Benjamin L. Walter, et al.

    Intracortical brain-computer interfaces (iBCIs) have the potential to restore hand grasping and object interaction to individuals with tetraplegia. Optimal grasping and object interaction require simultaneous production of both force and grasp outputs. However, since overlapping neural populations are modulated by both parameters, grasp type could affect how well forces are decoded from motor cortex in a closed-loop force iBCI. Therefore, this work quantified the neural representation and offline decoding performance of discrete hand grasps and force levels in two participants with tetraplegia. Participants attempted to produce three discrete forces (light, medium, hard) using up to five hand grasp configurations. A two-way Welch ANOVA was implemented on multiunit neural features to assess their modulation to force and grasp . Demixed principal component analysis was used to assess for population-level tuning to force and grasp and to predict these parameters from neural activity. Three major findings emerged from this work: 1) Force information was neurally represented and could be decoded across multiple hand grasps (and, in one participant, across attempted elbow extension as well); 2) Grasp type affected force representation within multi-unit neural features and offline force classification accuracy; and 3) Grasp was classified more accurately and had greater population-level representation than force. These findings suggest that force and grasp have both independent and interacting representations within cortex, and that incorporating force control into real-time iBCI systems is feasible across multiple hand grasps if the decoder also accounts for grasp type. Significance Statement: Intracortical brain-computer interfaces (iBCIs) have emerged as a promising technology to potentially restore hand grasping and object interaction in people with tetraplegia. This study is among the first to quantify the degree to which hand grasp affects force-related – or kinetic – neural activity and decoding performance in individuals with tetraplegia. The study results enhance our overall understanding of how the brain encodes kinetic parameters across varying kinematic behaviors -- and in particular, the degree to which these parameters have independent versus interacting neural representations. Such investigations are a critical first step to incorporating force control into human-operated iBCI systems, which would move the technology towards restoring more functional and naturalistic tasks.


  • Closed-loop cortical control of virtual reach and posture using Cartesian and joint velocity commands

    by D Young, F Willett, W D Memberg, B Murphy, P Rezaii, B Walter, J Sweet, J Miller, K V Shenoy, L R Hochberg, et al.

    Objective . Brain–computer interfaces (BCIs) are a promising technology for the restoration of function to people with paralysis, especially for controlling coordinated reaching. Typical BCI studies decode Cartesian endpoint velocities as commands, but human arm movements might be better controlled in a joint-based coordinate frame, which may match underlying movement encoding in the motor cortex. A better understanding of BCI controlled reaching by people with paralysis may lead to performance improvements in brain-controlled assistive devices. Approach . Two intracortical BCI participants in the BrainGate2 pilot clinical trial performed a visual 3D endpoint virtual reality reaching task using two decoders: Cartesian and joint velocity. Task performance metrics (i.e. success rate and path efficiency) and single feature and population tuning were compared across the two decoder conditions. The participants also demonstrated the first BCI control of a fourth dimension of reaching, the arm’s swivel angle, in a 4D posture matching task. Main results . Both users achieved significantly higher success rates using Cartesian velocity control, and joint controlled trajectories were more variable and significantly more curved. Neural tuning analyses showed that most single feature activity was best described by a Cartesian kinematic encoding model, and population analyses revealed only slight differences in aggregate activity between the decoder conditions. Simulations of a BCI user reproduced trajectory features seen during closed-loop joint control when assuming only Cartesian-tuned features passed through a joint decoder. With minimal training, both participants controlled the virtual arm’s swivel angle to complete a 4D posture matching task, and achieved significantly higher success using a Cartesian + swivel velocity decoder compared to a joint velocity decoder. Significance . These results suggest that Cartesian velocity command interfaces may provide better BCI control of arm movements than other kinematic variables, even in 4D posture tasks with swivel angle targets.


  • Signal processing methods for reducing artifacts in microelectrode brain recordings caused by functional electrical stimulation

    by D Young, F Willett, W D Memberg, B Murphy, B Walter, J Sweet, J Miller, L R Hochberg, R F Kirsch, A B Ajiboye

    Objective . Functional electrical stimulation (FES) is a promising technology for restoring movement to paralyzed limbs. Intracortical brain–computer interfaces (iBCIs) have enabled intuitive control over virtual and robotic movements, and more recently over upper extremity FES neuroprostheses. However, electrical stimulation of muscles creates artifacts in intracortical microelectrode recordings that could degrade iBCI performance. Here, we investigate methods for reducing the cortically recorded artifacts that result from peripheral electrical stimulation. Approach . One participant in the BrainGate2 pilot clinical trial had two intracortical microelectrode arrays placed in the motor cortex, and thirty-six stimulating intramuscular electrodes placed in the muscles of the contralateral limb. We characterized intracortically recorded electrical artifacts during both intramuscular and surface stimulation. We compared the performance of three artifact reduction methods: blanking, common average reference (CAR) and linear regression reference (LRR), which creates channel-specific reference signals, composed of weighted sums of other channels. Main results . Electrical artifacts resulting from surface stimulation were 175 × larger than baseline neural recordings (which were 110 µ V peak-to-peak), while intramuscular stimulation artifacts were only 4 × larger. The artifact waveforms were highly consistent across electrodes within each array. Application of LRR reduced artifact magnitudes to less than 10 µ V and largely preserved the original neural feature values used for decoding. Unmitigated stimulation artifacts decreased iBCI decoding performance, but performance was almost completely recovered using LRR, which outperformed CAR and blanking and extracted useful neural information during stimulation artifact periods. Significance . The LRR method was effective at reducing electrical artifacts resulting from both intramuscular and surface FES, and almost completely restored iBCI decoding performance (>90% recovery for surface stimulation and full recovery for intramuscular stimulation). The results demonstrate that FES-induced artifacts can be easily mitigated in FES + iBCI systems by using LRR for artifact reduction, and suggest that the LRR method may also be useful in other noise reduction applications.


  • A Comparison of Intention Estimation Methods for Decoder Calibration in Intracortical Brain–Computer Interfaces

    by Francis R. Willett, Brian A. Murphy, Daniel R. Young, William D. Memberg, Christine H. Blabe, Chethan Pandarinath, Brian Franco, Jad Saab, Benjamin L. Walter, Jennifer A. Sweet, et al.

    Objective: Recent reports indicate that making better assumptions about the user’s intended movement can improve decoder calibration for intracortical brain-computer interfaces. Several methods now exist for estimating user intent, including an optimal feedback control model, a piecewise-linear feedback control model, ReFIT, and other heuristics. Which of these methods yields the best decoding performance? Methods: Using data from the BrainGate2 pilot clinical trial, we measured how a steady-state velocity Kalman filter decoder was affected by the choice of intention estimation method. We examined three separate components of the Kalman filter: dimensionality reduction, temporal smoothing, and output gain (speed scaling). Results: The decoder’s dimensionality reduction properties were largely unaffected by the intention estimation method (the unsmoothed velocity vectors differed by 50% difference in average values). Surprisingly, simulation results show that these differences in gain and smoothing values were largely arbitrary, as all methods failed to optimize the gain and smoothing values to match the task parameters. Conclusion: Our results show that, gain and smoothing differences aside, current intention estimation methods yield nearly equivalent decoders and that simple models of user intent, such as a position error vector (target position minus cursor position), perform comparably to more elaborate models. Our results also highlight that current calibration methods yield arbitrary differences in gain and smoothing properties that can confound decoder comparisons.


  • Open Access

    “Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves”

    by Breanne P. Christie, Max Freeberg, William D. Memberg, Gilles J. C. Pinault, Harry A. Hoyen, Dustin J. Tyler, Ronald J. Triolo

    Electrical stimulation of the peripheral nerves has been shown to be effective in restoring sensory and motor functions in the lower and upper extremities. This neural stimulation can be applied via non-penetrating spiral nerve cuff electrodes, though minimal information has been published regarding their long-term performance for multiple years after implantation. Since 2005, 14 human volunteers with cervical or thoracic spinal cord injuries, or upper limb amputation, were chronically implanted with a total of 50 spiral nerve cuff electrodes on 10 different nerves (mean time post-implant 6.7 ± 3.1 years). The primary outcome measures utilized in this study were muscle recruitment curves, charge thresholds, and percent overlap of recruited motor unit populations. In the eight recipients still actively involved in research studies, 44/45 of the spiral contacts were still functional. In four participants regularly studied over the course of 1 month to 10.4 years, the charge thresholds of the majority of individual contacts remained stable over time. The four participants with spiral cuffs on their femoral nerves were all able to generate sufficient moment to keep the knees locked during standing after 2–4.5 years. The dorsiflexion moment produced by all four fibular nerve cuffs in the active participants exceeded the value required to prevent foot drop, but no tibial nerve cuffs were able to meet the plantarflexion moment that occurs during push-off at a normal walking speed. The selectivity of two multi-contact spiral cuffs was examined and both were still highly selective for different motor unit populations for up to 6.3 years after implantation. The spiral nerve cuffs examined remain functional in motor and sensory neuroprostheses for 2–11 years after implantation. They exhibit stable charge thresholds, clinically relevant recruitment properties, and functional muscle selectivity. Non-penetrating spiral nerve cuff electrodes appear to be a suitable option for long-term clinical use on human peripheral nerves in implanted neuroprostheses.


  • Top Cited Papers
    Open Access

    Restoration of reaching and grasping movements through brain-controlled muscle stimulation in a person with tetraplegia: a proof-of-concept demonstration

    by A Bolu Ajiboye, Francis R Willett, Daniel R Young, William D Memberg, Brian A Murphy, Jonathan P Miller, Benjamin L Walter, Jennifer A Sweet, Harry A Hoyen, Michael W Keith, et al.