Manel Vera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Manel Vera has a total of 229 co-authors. Here are the top co-authors by number of shared publications:
- Francisco Maduell
Hospital Clinic de Barcelona, Barcelona, Spain
28 shared publications - Aleix Cases
Institut d’Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), 08036 Barcelona, Spain
17 shared publications Néstor Fontseré
15 shared publications- Josep Maria Campistol
Hospital Clinic of Barcelona, Carrer Villarroel, 170, 08036 Barcelona, Spain
13 shared publications Lida Rodas
Department of Nephrology and Renal Transplantation, Hospital Clínic of Barcelona, Barcelona, Spain
12 shared publicationsRaquel Ojeda
Department of Nephrology, Hospital Clinic Barcelona, Barcelona, Spain
12 shared publications
Latest Publications
- Open Access
- 29 June 2023
- Published by Oxford University Press (OUP) in Clinical Kidney Journal
- Vol. 16 (12) , 2493-2502
Opportunities to improve the management of anemia in peritoneal dialysis patients: lessons from a national study in routine clinical practice
Background: Current guidelines establish the same hemoglobin (Hb) and iron biomarkers targets for hemodialysis (HD) and peritoneal dialysis (PD) in patients receiving erythropoiesis-stimulating agents (ESAs) even though patients having PD are usually younger, more active and less comorbid. Unfortunately, specific renal anemia [anemia in chronic kidney disease (aCKD)] trials or observational studies on PD are scanty. The aims of this study were to describe current aCKD management, goals and adherence to clinical guidelines, identifying opportunities for healthcare improvement in PD patients. Methods: This was a retrospective, nationwide, multicentre study including patients from 19 PD units. The nephrologists collected baseline data, demographics, comorbidities and data related to anemia management (laboratory values, previously prescribed treatments and subsequent adjustments) from electronic medical records. The European adaptation of KDIGO guidelines was the reference for definitions, drug prescriptions and targets. Results: A total of 343 patients (mean age 62.9 years, 61.2% male) were included; 72.9% were receiving ESAs and 33.2% iron therapy [20.7% intravenously (IV)]. Eighty-two patients were receiving ESA without iron therapy, despite 53 of them having an indication according to the European Renal Best Practice guidelines. After laboratory results, iron therapy was only started in 15% of patients. Among ESA-treated patients, 51.9% had an optimal control [hemoglobin (Hb) 10–12 g/dL] and 28.3% between 12–12.9 g/dL. Seventeen patients achieved Hb >13 g/dL, and 12 of them remained on ESA after overshooting. Only three patients had Hb 300 IU/kg/week). The highest tertile of erythropoietin resistance index (>6.3 UI/kg/week/g/dL) was associated with iron deficiency and low albumin corrected by renal replacement therapy vintage and hospital admissions in the previous 3 months. Conclusion: Iron therapy continues to be underused (especially IV). Low albumin, iron deficiency and prior events explain most of the ESA hyporesponsiveness. Hb targets are titrated to/above the upper limits. Thus, several missed opportunities for adequate prescriptions and adherence to guidelines were identified.
- 29 June 2023
- Published by Oxford University Press (OUP) in Clinical Kidney Journal
- Vol. 16 (12) , 2493-2502
Open AccessOpportunities to improve the management of anemia in peritoneal dialysis patients: lessons from a national study in routine clinical practice
Background: Current guidelines establish the same hemoglobin (Hb) and iron biomarkers targets for hemodialysis (HD) and peritoneal dialysis (PD) in patients receiving erythropoiesis-stimulating agents (ESAs) even though patients having PD are usually younger, more active and less comorbid. Unfortunately, specific renal anemia [anemia in chronic kidney disease (aCKD)] trials or observational studies on PD are scanty. The aims of this study were to describe current aCKD management, goals and adherence to clinical guidelines, identifying opportunities for healthcare improvement in PD patients. Methods: This was a retrospective, nationwide, multicentre study including patients from 19 PD units. The nephrologists collected baseline data, demographics, comorbidities and data related to anemia management (laboratory values, previously prescribed treatments and subsequent adjustments) from electronic medical records. The European adaptation of KDIGO guidelines was the reference for definitions, drug prescriptions and targets. Results: A total of 343 patients (mean age 62.9 years, 61.2% male) were included; 72.9% were receiving ESAs and 33.2% iron therapy [20.7% intravenously (IV)]. Eighty-two patients were receiving ESA without iron therapy, despite 53 of them having an indication according to the European Renal Best Practice guidelines. After laboratory results, iron therapy was only started in 15% of patients. Among ESA-treated patients, 51.9% had an optimal control [hemoglobin (Hb) 10–12 g/dL] and 28.3% between 12–12.9 g/dL. Seventeen patients achieved Hb >13 g/dL, and 12 of them remained on ESA after overshooting. Only three patients had Hb 300 IU/kg/week). The highest tertile of erythropoietin resistance index (>6.3 UI/kg/week/g/dL) was associated with iron deficiency and low albumin corrected by renal replacement therapy vintage and hospital admissions in the previous 3 months. Conclusion: Iron therapy continues to be underused (especially IV). Low albumin, iron deficiency and prior events explain most of the ESA hyporesponsiveness. Hb targets are titrated to/above the upper limits. Thus, several missed opportunities for adequate prescriptions and adherence to guidelines were identified.
- Open Access
- 14 June 2023
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 38 (Supplement)
#6844 MONITOR SWITCHING-INDUCED VARIATIONS IN CONDUCTIVITY AND PLASMA SODIUM DURING HEMODIALYSIS SESSIONS
Background and Aims: Until the advent of the new monitors with sodium modules, the differences between prescribed and actual sodium have been little studied. And most dialysis centers have a fixed sodium prescription. However, the sodium gradient during sessions is one of the key factors in its balance in hemodialysis patients. Predialysis plasma sodium has an important interindividual but not intraindividual variability, which supports the hypothesis of reference sodium (setpoint). This work aimed to compare the impact of switching from the 5008 Cordiax monitor to the new 6008 Cordiax monitor on the actually measured conductivity and initial and final plasma sodium. Method: A total of 106 hemodialysis patients were included. Each patient received two dialysis sessions in which only the monitor was varied. The variables collected were: concentrate, prescribed sodium and bicarbonate, real conductivity, initial and final plasma sodium measured by ionic dialysance, and the change in plasma sodium concentration during treatment (ΔPNa), which has been related to mortality when it exceeds 4 mmol/L, was calculated. The clinical research ethics committee of Hospital Clínic de Barcelona approved the present study. Results: The change of dialysis monitor showed small, although significant, differences in initial (138.14 mmol/L with 5008 vs. 138.81 mmol/L with 6008) and final plasma sodium (139.58 mmol/L vs. 140.97 mmol/L), as well as in the actual conductivity obtained (13.97 vs. 14.1 mS/cm). The ΔPNa also increased significantly, with the percentage of patients with a ΔPNa greater than 4 mmol/L going from 6 to 22% with the monitor change. All these differences were statistically significant regardless of the concentrate used. All sessions were performed without notable clinical incidents, hypotension, cramps or thirst episodes. Conclusion: The ultimate goal of hemodialysis should be to achieve isonatremia that allows complete elimination of interdialytic sodium gain and avoid intradialytic sodium loading. The change from 5008 to 6008 monitor is associated with an increase in conductivity, higher plasma sodium, and an increase in ΔPNa. Knowing and confirming this change will allow us to individualize the sodium prescription to find adequate isonatremic dialysis and, thus, avoid possible adverse effects.
- 14 June 2023
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 38 (Supplement)
Open Access#6844 MONITOR SWITCHING-INDUCED VARIATIONS IN CONDUCTIVITY AND PLASMA SODIUM DURING HEMODIALYSIS SESSIONS
Background and Aims: Until the advent of the new monitors with sodium modules, the differences between prescribed and actual sodium have been little studied. And most dialysis centers have a fixed sodium prescription. However, the sodium gradient during sessions is one of the key factors in its balance in hemodialysis patients. Predialysis plasma sodium has an important interindividual but not intraindividual variability, which supports the hypothesis of reference sodium (setpoint). This work aimed to compare the impact of switching from the 5008 Cordiax monitor to the new 6008 Cordiax monitor on the actually measured conductivity and initial and final plasma sodium. Method: A total of 106 hemodialysis patients were included. Each patient received two dialysis sessions in which only the monitor was varied. The variables collected were: concentrate, prescribed sodium and bicarbonate, real conductivity, initial and final plasma sodium measured by ionic dialysance, and the change in plasma sodium concentration during treatment (ΔPNa), which has been related to mortality when it exceeds 4 mmol/L, was calculated. The clinical research ethics committee of Hospital Clínic de Barcelona approved the present study. Results: The change of dialysis monitor showed small, although significant, differences in initial (138.14 mmol/L with 5008 vs. 138.81 mmol/L with 6008) and final plasma sodium (139.58 mmol/L vs. 140.97 mmol/L), as well as in the actual conductivity obtained (13.97 vs. 14.1 mS/cm). The ΔPNa also increased significantly, with the percentage of patients with a ΔPNa greater than 4 mmol/L going from 6 to 22% with the monitor change. All these differences were statistically significant regardless of the concentrate used. All sessions were performed without notable clinical incidents, hypotension, cramps or thirst episodes. Conclusion: The ultimate goal of hemodialysis should be to achieve isonatremia that allows complete elimination of interdialytic sodium gain and avoid intradialytic sodium loading. The change from 5008 to 6008 monitor is associated with an increase in conductivity, higher plasma sodium, and an increase in ΔPNa. Knowing and confirming this change will allow us to individualize the sodium prescription to find adequate isonatremic dialysis and, thus, avoid possible adverse effects.
- 13 June 2023
- Published by S. Karger AG in American Journal of Nephrology
- Vol. 54 (7-8) , 291-298
Results of Salt Intake Restriction Monitored with the New Sodium Control Biosensor
Introduction: Adherence to a low-sodium (Na) diet is crucial in patients under hemodialysis, as it improves cardiovascular outcomes and reduces thirst and interdialytic weight gain. Recommended salt intake is lower than 5 g/day. The new 6008 CAREsystem monitors incorporate a Na module that offers the advantage of estimating patients’ salt intake. The objective of this study was to evaluate the effect of dietary Na restriction for 1 week, monitored with the Na biosensor. Methods: A prospective study was conducted in 48 patients who maintained their usual dialysis parameters and were dialyzed with a 6008 CAREsystem monitor with activation of the Na module. Total Na balance, pre-/post-dialysis weight, serum Na (sNa), changes in pre- to post-dialysis sNa (ΔsNa), diffusive balance, and systolic and diastolic blood pressure were compared twice, once after 1 week of patients’ usual Na diet and again after another week with more restricted Na intake. Results: Restricted Na intake increased the percentage of patients on a low-Na diet (<85 Na mmol/day) from 8% to 44%. Average daily Na intake decreased from 149 ± 54 to 95 ± 49 mmol, and interdialytic weight gain was reduced by 460 ± 484 g per session. More restricted Na intake also decreased pre-dialysis sNa and increased both intradialytic diffusive balance and ΔsNa. In hypertensive patients, reducing daily Na by more than 3 g Na/day lowered their systolic blood pressure. Conclusions: The new Na module allowed objective monitoring of Na intake, which in turn could permit more precise personalized dietary recommendations in patients under hemodialysis.
- 13 June 2023
- Published by S. Karger AG in American Journal of Nephrology
- Vol. 54 (7-8) , 291-298
Results of Salt Intake Restriction Monitored with the New Sodium Control Biosensor
Introduction: Adherence to a low-sodium (Na) diet is crucial in patients under hemodialysis, as it improves cardiovascular outcomes and reduces thirst and interdialytic weight gain. Recommended salt intake is lower than 5 g/day. The new 6008 CAREsystem monitors incorporate a Na module that offers the advantage of estimating patients’ salt intake. The objective of this study was to evaluate the effect of dietary Na restriction for 1 week, monitored with the Na biosensor. Methods: A prospective study was conducted in 48 patients who maintained their usual dialysis parameters and were dialyzed with a 6008 CAREsystem monitor with activation of the Na module. Total Na balance, pre-/post-dialysis weight, serum Na (sNa), changes in pre- to post-dialysis sNa (ΔsNa), diffusive balance, and systolic and diastolic blood pressure were compared twice, once after 1 week of patients’ usual Na diet and again after another week with more restricted Na intake. Results: Restricted Na intake increased the percentage of patients on a low-Na diet (<85 Na mmol/day) from 8% to 44%. Average daily Na intake decreased from 149 ± 54 to 95 ± 49 mmol, and interdialytic weight gain was reduced by 460 ± 484 g per session. More restricted Na intake also decreased pre-dialysis sNa and increased both intradialytic diffusive balance and ΔsNa. In hypertensive patients, reducing daily Na by more than 3 g Na/day lowered their systolic blood pressure. Conclusions: The new Na module allowed objective monitoring of Na intake, which in turn could permit more precise personalized dietary recommendations in patients under hemodialysis.
- Open Access
- 23 January 2023
- Published by Oxford University Press (OUP) in Clinical Kidney Journal
- Vol. 16 (5) , 859-867
Practical implementation and clinical benefits of the new automated dialysate sodium control biosensor
Background: A key feature of dialysis treatment is the prescription of dialysate sodium (Na). This study aimed to describe the practical implementation of a new automated dialysate Na control biosensor and to assess its tolerance and the beneficial clinical effects of isonatraemic dialysis. Methods: A prospective study was carried out in 86 patients who, along with their usual parameters, received the following five consecutive phases of treatment for 3 weeks each: phase 0: baseline 5008 machine; phases 1 and 2: 6008 machine without activation of the Na control biosensor and the same fixed individualized Na dialysate prescription or adjusted to obtain similar conductivity to phase 0; phases 3 and 4: activated Na control to isonatraemic dialysis (Na dialysate margins 135–141 or 134–142 mmol/L). Results: When the Na control was activated, the few episodes of cramps or hypotension disappeared when the lower dialysate Na margin was increased by 1 or 2 mmol/L. The activated Na control module showed significant differences compared with baseline and the non-activated Na module in final serum Na values, diffusive Na balance, and changes in pre- to postdialysis plasma Na values. The mean predialysis systolic blood pressure value was significantly lower in phase 4 than in phase 1. There were no significant differences in total Na balance in the four 6008 phases evaluated. Conclusions: The implementation of the automated dialysate Na control module is a useful new tool, which reduced the diffusive load of Na with good tolerance. The module had the advantages of reducing thirst, interdialytic weight gain and intradialytic plasma Na changes.
- 23 January 2023
- Published by Oxford University Press (OUP) in Clinical Kidney Journal
- Vol. 16 (5) , 859-867
Open AccessPractical implementation and clinical benefits of the new automated dialysate sodium control biosensor
Background: A key feature of dialysis treatment is the prescription of dialysate sodium (Na). This study aimed to describe the practical implementation of a new automated dialysate Na control biosensor and to assess its tolerance and the beneficial clinical effects of isonatraemic dialysis. Methods: A prospective study was carried out in 86 patients who, along with their usual parameters, received the following five consecutive phases of treatment for 3 weeks each: phase 0: baseline 5008 machine; phases 1 and 2: 6008 machine without activation of the Na control biosensor and the same fixed individualized Na dialysate prescription or adjusted to obtain similar conductivity to phase 0; phases 3 and 4: activated Na control to isonatraemic dialysis (Na dialysate margins 135–141 or 134–142 mmol/L). Results: When the Na control was activated, the few episodes of cramps or hypotension disappeared when the lower dialysate Na margin was increased by 1 or 2 mmol/L. The activated Na control module showed significant differences compared with baseline and the non-activated Na module in final serum Na values, diffusive Na balance, and changes in pre- to postdialysis plasma Na values. The mean predialysis systolic blood pressure value was significantly lower in phase 4 than in phase 1. There were no significant differences in total Na balance in the four 6008 phases evaluated. Conclusions: The implementation of the automated dialysate Na control module is a useful new tool, which reduced the diffusive load of Na with good tolerance. The module had the advantages of reducing thirst, interdialytic weight gain and intradialytic plasma Na changes.
- Open Access
- 13 July 2022
- Published by Oxford University Press (OUP) in Clinical Kidney Journal
- Vol. 15 (12) , 2292-2299
Comparison of four medium cut-off dialyzers
Background: Recently, several pharmaceutical companies have developed new medium cut-off (MCO) dialyzers for expanded hemodialysis (HDx). This study aimed to compare the safety and efficacy of four MCO dialyzers, against each other and versus high-flux hemodialysis (HD) and post-dilution hemodiafiltration (HDF). Methods: A prospective study was carried out on 23 patients who underwent six dialysis sessions: two sessions with the FX80 Cordiax in HD and HDF, and four HDx sessions with the Phylther 17-SD, Vie-18X, Elisio HX19 and Theranova 400 dialyzers. The reduction ratios (RRs) of urea, creatinine, β2-microglobulin, myoglobin, kappa free immunoglobulin light chain (κFLC), prolactin, α1-microglobulin, α1-acid glycoprotein, lambda (λFLC) and albumin were compared. Dialysate albumin loss was also measured. Results: The differences in efficacy between the evaluated dialyzers were minimal in small molecules and even up to the size of β2-microglobulin. The main differences were found between myoglobin, κFLC, prolactin, α1-microglobulin and λFLC RRs, in which all four MCO dialyzers, with similar efficacy, were clearly superior to HD and slightly inferior to HDF treatment. Albumin losses in the dialysate with HD dialyzers were <1 g and between 1.5 and 2.5 g in HDx and HDF. The global removal score values were similar in all four HDx treatments, and again significantly higher than those with HD. Conclusions: The results of the four MCO dialyzers evaluated in this study showed good efficiency, with no significant performance differences between them while being completely safe in terms of albumin loss. Likewise, the study confirms the superiority of HDx over high-flux HD with an efficacy close to that of post-dilution HDF.
- 13 July 2022
- Published by Oxford University Press (OUP) in Clinical Kidney Journal
- Vol. 15 (12) , 2292-2299
Open AccessComparison of four medium cut-off dialyzers
Background: Recently, several pharmaceutical companies have developed new medium cut-off (MCO) dialyzers for expanded hemodialysis (HDx). This study aimed to compare the safety and efficacy of four MCO dialyzers, against each other and versus high-flux hemodialysis (HD) and post-dilution hemodiafiltration (HDF). Methods: A prospective study was carried out on 23 patients who underwent six dialysis sessions: two sessions with the FX80 Cordiax in HD and HDF, and four HDx sessions with the Phylther 17-SD, Vie-18X, Elisio HX19 and Theranova 400 dialyzers. The reduction ratios (RRs) of urea, creatinine, β2-microglobulin, myoglobin, kappa free immunoglobulin light chain (κFLC), prolactin, α1-microglobulin, α1-acid glycoprotein, lambda (λFLC) and albumin were compared. Dialysate albumin loss was also measured. Results: The differences in efficacy between the evaluated dialyzers were minimal in small molecules and even up to the size of β2-microglobulin. The main differences were found between myoglobin, κFLC, prolactin, α1-microglobulin and λFLC RRs, in which all four MCO dialyzers, with similar efficacy, were clearly superior to HD and slightly inferior to HDF treatment. Albumin losses in the dialysate with HD dialyzers were <1 g and between 1.5 and 2.5 g in HDx and HDF. The global removal score values were similar in all four HDx treatments, and again significantly higher than those with HD. Conclusions: The results of the four MCO dialyzers evaluated in this study showed good efficiency, with no significant performance differences between them while being completely safe in terms of albumin loss. Likewise, the study confirms the superiority of HDx over high-flux HD with an efficacy close to that of post-dilution HDF.
- Open Access
- 12 May 2022
- Published by S. Karger AG in Blood Purification
- Vol. 52 (1) , 68-74
Efficacy and Safety of the Medium Cut-Off Elisio HX Dialyzer
Introduction: The medium cut-off Elisio HX dialyzer by Nipro became commercially available in Europe in 2021, but there are still no reports of in vivo data. This study aimed to evaluate the safety and efficacy of it compared with previously evaluated hemodialysis (HD), expanded HD (HDx), and postdilution hemodiafiltration (HDF) treatments. Methods: A prospective study was carried out on 18 patients who underwent 5 dialysis sessions: FX80 Cordiax in HD, Elisio H19 in HD, Elisio HX19 in HDx, Theranova 400 in HDx, and FX80 Cordiax in HDF. The reduction ratios of urea, creatinine, ß2-microglobulin, myoglobin, kappa FLC, prolactin, α1-microglobulin, α1-acid glycoprotein, lambda FLC, and albumin were compared. Dialysate albumin loss was measured. Results: The comparison between the different dialysis modalities revealed no difference for small molecules, but HDx and HDF were significantly more efficient than HD for medium and large molecule removal. The efficacy of Elisio HX19 dialyzer in HDx was similar to the Theranova 400, superior to both dialyzers in HD, and slightly lower than HDF. Albumin losses in dialysate with HD dialyzers were less than 1 g, but between 1.5 and 2.5 g in HDx and HDF. The global removal score (GRS) values with HDx treatments were statistically significantly higher than those with HD. The highest GRS was obtained with the helixone dialyzer in HDF. Conclusions: The new MCO dialyzer, Elisio HX, performs with excellent behavior and tolerance. It represents an upgrade compared to their predecessor and is very close to the removal capacity of HDF treatment.
- 12 May 2022
- Published by S. Karger AG in Blood Purification
- Vol. 52 (1) , 68-74
Open AccessEfficacy and Safety of the Medium Cut-Off Elisio HX Dialyzer
Introduction: The medium cut-off Elisio HX dialyzer by Nipro became commercially available in Europe in 2021, but there are still no reports of in vivo data. This study aimed to evaluate the safety and efficacy of it compared with previously evaluated hemodialysis (HD), expanded HD (HDx), and postdilution hemodiafiltration (HDF) treatments. Methods: A prospective study was carried out on 18 patients who underwent 5 dialysis sessions: FX80 Cordiax in HD, Elisio H19 in HD, Elisio HX19 in HDx, Theranova 400 in HDx, and FX80 Cordiax in HDF. The reduction ratios of urea, creatinine, ß2-microglobulin, myoglobin, kappa FLC, prolactin, α1-microglobulin, α1-acid glycoprotein, lambda FLC, and albumin were compared. Dialysate albumin loss was measured. Results: The comparison between the different dialysis modalities revealed no difference for small molecules, but HDx and HDF were significantly more efficient than HD for medium and large molecule removal. The efficacy of Elisio HX19 dialyzer in HDx was similar to the Theranova 400, superior to both dialyzers in HD, and slightly lower than HDF. Albumin losses in dialysate with HD dialyzers were less than 1 g, but between 1.5 and 2.5 g in HDx and HDF. The global removal score (GRS) values with HDx treatments were statistically significantly higher than those with HD. The highest GRS was obtained with the helixone dialyzer in HDF. Conclusions: The new MCO dialyzer, Elisio HX, performs with excellent behavior and tolerance. It represents an upgrade compared to their predecessor and is very close to the removal capacity of HDF treatment.
- 12 December 2021
- Published by OA Publishers Private Limited in Journal of Clinical and Medical Images, Case Reports
- Vol. 1 (1)
Early leakage of peritoneal effluent to subcutaneous tissue after a sneeze
Journal of Clinical & Medical Images Case Reports (JCMICR) - (ISSN 2771-019X )
- 12 December 2021
- Published by OA Publishers Private Limited in Journal of Clinical and Medical Images, Case Reports
- Vol. 1 (1)
Early leakage of peritoneal effluent to subcutaneous tissue after a sneeze
Journal of Clinical & Medical Images Case Reports (JCMICR) - (ISSN 2771-019X )
- Open Access
- 9 December 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (12) , e0258440
Current clinical practice in adapted automated peritoneal dialysis (aAPD)—A prospective, non-interventional study
Adapted automated peritoneal dialysis (aAPD), comprising a sequence of dwells with different durations and fill volumes, has been shown to enhance both ultrafiltration and solute clearance compared to standard peritoneal dialysis with constant time and volume dwells. The aim of this non-interventional study was to describe the different prescription patterns used in aAPD in clinical practice and to observe outcomes characterizing volume status, dialysis efficiency, and residual renal function over 1 year. Prevalent and incident, adult aAPD patients were recruited during routine clinic visits, and aAPD prescription, volume status, residual renal function and laboratory data were documented at baseline and every quarter thereafter for 1 year. Treatments were prescribed according to the nephrologist’s medical judgement in accordance with each center’s clinical routine. Of 180 recruited patients, 160 were analyzed. 27 different aAPD prescription patterns were identified. 79 patients (49.4%) received 2 small, short dwells followed by 3 long, large dwells. During follow-up, volume status changed only marginally, with visit mean values ranging between 1.59 (95% confidence interval: 1.19; 1.99) and 1.97 (1.33; 2.61) L. Urine output and creatinine clearance decreased significantly, accompanied by reductions in ultrafiltration and Kt/V. 25 patients (15.6%) received a renal transplant and 15 (9.4%) were changed to hemodialysis. Options for individualization offered by aAPD are actually used in practice for optimized treatment. Changes observed in renal function and dialysis efficiency measures reflect the natural course of chronic kidney disease. No safety events were observed during the study period.
- 9 December 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (12) , e0258440
Open AccessCurrent clinical practice in adapted automated peritoneal dialysis (aAPD)—A prospective, non-interventional study
Adapted automated peritoneal dialysis (aAPD), comprising a sequence of dwells with different durations and fill volumes, has been shown to enhance both ultrafiltration and solute clearance compared to standard peritoneal dialysis with constant time and volume dwells. The aim of this non-interventional study was to describe the different prescription patterns used in aAPD in clinical practice and to observe outcomes characterizing volume status, dialysis efficiency, and residual renal function over 1 year. Prevalent and incident, adult aAPD patients were recruited during routine clinic visits, and aAPD prescription, volume status, residual renal function and laboratory data were documented at baseline and every quarter thereafter for 1 year. Treatments were prescribed according to the nephrologist’s medical judgement in accordance with each center’s clinical routine. Of 180 recruited patients, 160 were analyzed. 27 different aAPD prescription patterns were identified. 79 patients (49.4%) received 2 small, short dwells followed by 3 long, large dwells. During follow-up, volume status changed only marginally, with visit mean values ranging between 1.59 (95% confidence interval: 1.19; 1.99) and 1.97 (1.33; 2.61) L. Urine output and creatinine clearance decreased significantly, accompanied by reductions in ultrafiltration and Kt/V. 25 patients (15.6%) received a renal transplant and 15 (9.4%) were changed to hemodialysis. Options for individualization offered by aAPD are actually used in practice for optimized treatment. Changes observed in renal function and dialysis efficiency measures reflect the natural course of chronic kidney disease. No safety events were observed during the study period.
- 22 December 2020
- Published by S. Karger AG in Blood Purification
- Vol. 50 (4-5) , 531-538
SARS-CoV-2 Infection in a Spanish Cohort of CKD-5D Patients: Prevalence, Clinical Presentation, Outcomes, and De-Isolation Results
Introduction: COVID-19 is a highly contagious disease that has easily spread worldwide. Outpatient maintenance hemodialysis seems to entail an increased risk of contagion, and previous reports inform of increased mortality among this population. Methods: We retrospectively analyzed clinical and laboratory parameters, outcomes, and management once discharged of CKD-5D patients infected with SARS-CoV-2 from our health area. Results: Out of the 429 CKD-5D population, 36 were diagnosed with SARS-CoV-2 infection (8%): 34 on in-center hemodialysis and 2 on peritoneal dialysis. Five were asymptomatic. The most common symptom was fever (70%), followed by dyspnea and cough. History of cardiovascular disease and elevation of LDH and C-reactive protein during admission were associated with higher mortality. Thirteen patients died (36%), 8 patients were admitted to an ICU, and survival was low (38%) among the latter. The mean time to death was 12 days. Most discharged patients got negative rRT-PCR in nasopharyngeal swabs within 26 days of diagnosis. However, there is a portion of cured patients that continue to have positive results even more than 2 months after the initial presentation. Conclusions: Patients on dialysis have an increased mortality risk if infected with SARS-CoV-2. Preventive measures have proven useful. Thus, proper ones, such as universal screening of the population and isolation when required, need to be generalized. Better de-isolation criteria are necessary to ensure an appropriate use of public health resources.
- 22 December 2020
- Published by S. Karger AG in Blood Purification
- Vol. 50 (4-5) , 531-538
SARS-CoV-2 Infection in a Spanish Cohort of CKD-5D Patients: Prevalence, Clinical Presentation, Outcomes, and De-Isolation Results
Introduction: COVID-19 is a highly contagious disease that has easily spread worldwide. Outpatient maintenance hemodialysis seems to entail an increased risk of contagion, and previous reports inform of increased mortality among this population. Methods: We retrospectively analyzed clinical and laboratory parameters, outcomes, and management once discharged of CKD-5D patients infected with SARS-CoV-2 from our health area. Results: Out of the 429 CKD-5D population, 36 were diagnosed with SARS-CoV-2 infection (8%): 34 on in-center hemodialysis and 2 on peritoneal dialysis. Five were asymptomatic. The most common symptom was fever (70%), followed by dyspnea and cough. History of cardiovascular disease and elevation of LDH and C-reactive protein during admission were associated with higher mortality. Thirteen patients died (36%), 8 patients were admitted to an ICU, and survival was low (38%) among the latter. The mean time to death was 12 days. Most discharged patients got negative rRT-PCR in nasopharyngeal swabs within 26 days of diagnosis. However, there is a portion of cured patients that continue to have positive results even more than 2 months after the initial presentation. Conclusions: Patients on dialysis have an increased mortality risk if infected with SARS-CoV-2. Preventive measures have proven useful. Thus, proper ones, such as universal screening of the population and isolation when required, need to be generalized. Better de-isolation criteria are necessary to ensure an appropriate use of public health resources.
- Open Access
Endothelial Damage, Inflammation and Immunity in Chronic Kidney Disease
Chronic kidney disease (CKD) patients have an accelerated atherosclerosis, increased risk of thrombotic-ischemic complications, and excessive mortality rates when compared with the general population. There is also evidence of an endothelial damage in which the proinflammatory state, the enhanced oxidative stress, or the accumulation of toxins due to their reduced renal clearance in uremia play a role. Further, there is evidence that uremic endothelial cells are both involved in and victims of the activation of the innate immunity. Uremic endothelial cells produce danger associated molecular patterns (DAMPS), which by binding to specific pattern recognition receptors expressed in multiple cells, including endothelial cells, induce the expression of adhesion molecules, the production of proinflammatory cytokines and an enhanced production of reactive oxygen species in endothelial cells, which constitute a link between immunity and inflammation. The connection between endothelial damage, inflammation and defective immunity in uremia will be reviewed here.
Open AccessEndothelial Damage, Inflammation and Immunity in Chronic Kidney Disease
Chronic kidney disease (CKD) patients have an accelerated atherosclerosis, increased risk of thrombotic-ischemic complications, and excessive mortality rates when compared with the general population. There is also evidence of an endothelial damage in which the proinflammatory state, the enhanced oxidative stress, or the accumulation of toxins due to their reduced renal clearance in uremia play a role. Further, there is evidence that uremic endothelial cells are both involved in and victims of the activation of the innate immunity. Uremic endothelial cells produce danger associated molecular patterns (DAMPS), which by binding to specific pattern recognition receptors expressed in multiple cells, including endothelial cells, induce the expression of adhesion molecules, the production of proinflammatory cytokines and an enhanced production of reactive oxygen species in endothelial cells, which constitute a link between immunity and inflammation. The connection between endothelial damage, inflammation and defective immunity in uremia will be reviewed here.