Gaurish M. Naik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gaurish M. Naik has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Rajendra S. Gad
Electronics Programme, School of Physical and Applied Sciences, Goa University, Taliegao Plateau, India
4 shared publications - Jivan Shrikrishna Parab
School of Physical and Applied Sciences, Goa University, Taleigao Plateau, India
3 shared publications - Niyan Marchon
Padre Conceicao College of Engineering
2 shared publications - Anna Thomas
Electronics Programme, School of Physical and Applied Sciences, Goa University, Taliegao Plateau, India
1 shared publication - Arman Yusuf Shaikh
School of Physical and Applied Sciences, Goa University, Goa, India
1 shared publication Deepak Chodankar
Altera SoC Lab., Department of Electronics, Goa University, India
1 shared publication
Latest Publications
- 12 July 2023
- Published by Springer Nature
- p. C1
Correction to: Python Programming Recipes for IoT Applications
- 12 July 2023
- Published by Springer Nature
- p. C1
Correction to: Python Programming Recipes for IoT Applications
- Open Access
- 1 April 2020
- Published by Horizon Research Publishing Co., Ltd. in Universal Journal of Electrical and Electronic Engineering
- Vol. 7 (2) , 118-126
PCA Data Reduction for MIMO Based Channel, Capacity Enhancement Using 16-QAM Modulation
In the Modern Wireless Communication Systems, there is a direct need for the enhancement of the network capacity, in order to support more and more data. This paper describes the data reduction methodology for enhancement of channel capacity based on Principal Component Analysis (PCA) of the Multiple-Input-Multiple-Output (MIMO) based untether communication system. The communication system has employed 16 Quadrature Amplitude Modulation (16-QAM) scheme with LDPC for channel coding method for error correction. The proposed method here utilizes the Principal Component Analysis (PCA) for data reduction which transmits only the feature vectors i.e. Eigen Vector for the set of composite data for large numbers of signals data over time-stamped. The effectiveness of the proposed work is evident through the simulation results of the systems incorporating 1×1, 2×2, 3×3, 4×4 MIMO networks. We have presented RMSE analysis for the PCA regression for verification of the signal fidelity and the BER for confirmation of the recovery of the data over MIMO channel over LDPC coding. Here we observe that our proposed work has achieved much better results.
- 1 April 2020
- Published by Horizon Research Publishing Co., Ltd. in Universal Journal of Electrical and Electronic Engineering
- Vol. 7 (2) , 118-126
Open AccessPCA Data Reduction for MIMO Based Channel, Capacity Enhancement Using 16-QAM Modulation
In the Modern Wireless Communication Systems, there is a direct need for the enhancement of the network capacity, in order to support more and more data. This paper describes the data reduction methodology for enhancement of channel capacity based on Principal Component Analysis (PCA) of the Multiple-Input-Multiple-Output (MIMO) based untether communication system. The communication system has employed 16 Quadrature Amplitude Modulation (16-QAM) scheme with LDPC for channel coding method for error correction. The proposed method here utilizes the Principal Component Analysis (PCA) for data reduction which transmits only the feature vectors i.e. Eigen Vector for the set of composite data for large numbers of signals data over time-stamped. The effectiveness of the proposed work is evident through the simulation results of the systems incorporating 1×1, 2×2, 3×3, 4×4 MIMO networks. We have presented RMSE analysis for the PCA regression for verification of the signal fidelity and the BER for confirmation of the recovery of the data over MIMO channel over LDPC coding. Here we observe that our proposed work has achieved much better results.
- 20 August 2019
- Published by Springer Nature
- p. 113-121
FIR Filter Design Technique to Mitigate Gibb’s Phenomenon
- 20 August 2019
- Published by Springer Nature
- p. 113-121
FIR Filter Design Technique to Mitigate Gibb’s Phenomenon
- 27 June 2018
- Published by Springer Nature in CSI Transactions on ICT
- Vol. 6 (2) , 215-219
Farmer-friendly portable system for diagnosis of pest attack in cashew trees
- 27 June 2018
- Published by Springer Nature in CSI Transactions on ICT
- Vol. 6 (2) , 215-219
Farmer-friendly portable system for diagnosis of pest attack in cashew trees
- Open Access
- 29 March 2018
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 2018, 1-14
Linear Phase Sharp Transition BPF to Detect Noninvasive Maternal and Fetal Heart Rate
Fetal heart rate (FHR) detection can be monitored using either direct fetal scalp electrode recording (invasive) or by indirect noninvasive technique. Weeks before delivery, the invasive method poses a risk factor to the fetus, while the latter provides accurate fetal ECG (FECG) information which can help diagnose fetal’s well-being. Our technique employs variable order linear phase sharp transition (LPST) FIR band-pass filter which shows improved stopband attenuation at higher filter orders. The fetal frequency fiduciary edges form the band edges of the filter characterized by varying amounts of overlap of maternal ECG (MECG) spectrum. The one with the minimum maternal spectrum overlap was found to be optimum with no power line interference and maximum fetal heart beats being detected. The improved filtering is reflected in the enhancement of the performance of the fetal QRS detector (FQRS). The improvement has also occurred in fetal heart rate obtained using our algorithm which is in close agreement with the true reference (i.e., invasive fetal scalp ECG). The performance parameters of the FQRS detector such as sensitivity (Se), positive predictive value (PPV), and accuracy (F1) were found to improve even for lower filter order. The same technique was extended to evaluate maternal QRS detector (MQRS) and found to yield satisfactory maternal heart rate (MHR) results.
- 29 March 2018
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 2018, 1-14
Open AccessLinear Phase Sharp Transition BPF to Detect Noninvasive Maternal and Fetal Heart Rate
Fetal heart rate (FHR) detection can be monitored using either direct fetal scalp electrode recording (invasive) or by indirect noninvasive technique. Weeks before delivery, the invasive method poses a risk factor to the fetus, while the latter provides accurate fetal ECG (FECG) information which can help diagnose fetal’s well-being. Our technique employs variable order linear phase sharp transition (LPST) FIR band-pass filter which shows improved stopband attenuation at higher filter orders. The fetal frequency fiduciary edges form the band edges of the filter characterized by varying amounts of overlap of maternal ECG (MECG) spectrum. The one with the minimum maternal spectrum overlap was found to be optimum with no power line interference and maximum fetal heart beats being detected. The improved filtering is reflected in the enhancement of the performance of the fetal QRS detector (FQRS). The improvement has also occurred in fetal heart rate obtained using our algorithm which is in close agreement with the true reference (i.e., invasive fetal scalp ECG). The performance parameters of the FQRS detector such as sensitivity (Se), positive predictive value (PPV), and accuracy (F1) were found to improve even for lower filter order. The same technique was extended to evaluate maternal QRS detector (MQRS) and found to yield satisfactory maternal heart rate (MHR) results.
- Open Access
- 27 December 2016
- Published by Wiley in International Scholarly Research Notices
- Vol. 2016, 1-8
Efficient Data Transfer Rate and Speed of Secured Ethernet Interface System
Embedded systems are extensively used in home automation systems, small office systems, vehicle communication systems, and health service systems. The services provided by these systems are available on the Internet and these services need to be protected. Security features like IP filtering, UDP protection, or TCP protection need to be implemented depending on the specific application used by the device. Every device on the Internet must have network interface. This paper proposes the design of the embedded Secured Ethernet Interface System to protect the service available on the Internet against the SYN flood attack. In this experimental study, Secured Ethernet Interface System is customized to protect the web service against the SYN flood attack. Secured Ethernet Interface System is implemented on ALTERA Stratix IV FPGA as a system on chip and uses the modified SYN flood attack protection method. The experimental results using Secured Ethernet Interface System indicate increase in number of genuine clients getting service from the server, considerable improvement in the data transfer rate, and better response time during the SYN flood attack.
- 27 December 2016
- Published by Wiley in International Scholarly Research Notices
- Vol. 2016, 1-8
Open AccessEfficient Data Transfer Rate and Speed of Secured Ethernet Interface System
Embedded systems are extensively used in home automation systems, small office systems, vehicle communication systems, and health service systems. The services provided by these systems are available on the Internet and these services need to be protected. Security features like IP filtering, UDP protection, or TCP protection need to be implemented depending on the specific application used by the device. Every device on the Internet must have network interface. This paper proposes the design of the embedded Secured Ethernet Interface System to protect the service available on the Internet against the SYN flood attack. In this experimental study, Secured Ethernet Interface System is customized to protect the web service against the SYN flood attack. Secured Ethernet Interface System is implemented on ALTERA Stratix IV FPGA as a system on chip and uses the modified SYN flood attack protection method. The experimental results using Secured Ethernet Interface System indicate increase in number of genuine clients getting service from the server, considerable improvement in the data transfer rate, and better response time during the SYN flood attack.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 37, 473-476
Influence of PCA components on glucose prediction using non-invasive technique
A truly noninvasive blood glucose-sensing device could revolutionalize diabetes treatment and coupled with advances in microelectronics can improve compliance with recommended glucose levels and greatly influence the cost of diabetes monitoring. The paper describes a Multivariate PLSR system for blood glucose prediction by considering 5 major variants in human blood i.e Glucose, Alanine, Ascorbate, Lactate and Urea. The typical biological system that resembles human blood tissue consisting of five major constituents has been tested on the Partial Least Square Regression (PLSR) model reported by the authors elsewhere. Multivariate PLSR model is experimentally validated for 12 templates recorded using Schimatzu FTIR 8400S in the range 400cm-1 to 5000 cm-1. The model was validated using 2 approaches, namely, Root Mean Square Error (RMSE) and Clark Error Grid Analysis (CEGA) plot. The dependence of variate prediction on Principal Component Analysis(PCA) factors is also described and analyzed in detail.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 37, 473-476
Influence of PCA components on glucose prediction using non-invasive technique
A truly noninvasive blood glucose-sensing device could revolutionalize diabetes treatment and coupled with advances in microelectronics can improve compliance with recommended glucose levels and greatly influence the cost of diabetes monitoring. The paper describes a Multivariate PLSR system for blood glucose prediction by considering 5 major variants in human blood i.e Glucose, Alanine, Ascorbate, Lactate and Urea. The typical biological system that resembles human blood tissue consisting of five major constituents has been tested on the Partial Least Square Regression (PLSR) model reported by the authors elsewhere. Multivariate PLSR model is experimentally validated for 12 templates recorded using Schimatzu FTIR 8400S in the range 400cm-1 to 5000 cm-1. The model was validated using 2 approaches, namely, Root Mean Square Error (RMSE) and Clark Error Grid Analysis (CEGA) plot. The dependence of variate prediction on Principal Component Analysis(PCA) factors is also described and analyzed in detail.
- 13 August 2015
- Published by Springer Nature
- p. 367-382
Reliable and Scalable Architecture for Internet of Things for Sensors Using Soft-Core Processor
- 13 August 2015
- Published by Springer Nature
- p. 367-382
Reliable and Scalable Architecture for Internet of Things for Sensors Using Soft-Core Processor