Yongming Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yongming Yang has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Chong Zeng
School of Electrical Engineering, Chongqing University of Arts and Sciences, Chongqing, China
2 shared publications Quandi Wang
The Key Lab. of High Voltage Eng. & Elec. New Technology, Ministry of Education, Elec. Eng. College of Chongqing University, Chongqing City, 400044, China
2 shared publications- Song Huang
School of Electrical Engineering, Chongqing University, Chongqing, China
2 shared publications - Xinghuo Yu
RMIT University
2 shared publications - Ammad Jadoon
NFC-Institute of Engineering &Technology, Multan, Pakistan
1 shared publication Caixin Sun
Chongqing University, Chongqing, 400044, PR China; The Key Laboratory of High Voltage Engineering and Electrical New Technology, Ministry of Education, China
1 shared publication
Latest Publications
- 29 August 2023
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (5) , 3575-3586
Numerical Research of High-Voltage Conductors: Electric Field Characteristics in Ice-Covered Spaces
- 29 August 2023
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (5) , 3575-3586
Numerical Research of High-Voltage Conductors: Electric Field Characteristics in Ice-Covered Spaces
- 10 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (3) , 2366-2377
Online Rotor Fault Diagnosis of Permanent Magnet Synchronous Motors Based on Stator Tooth Flux
Demagnetization and eccentricity are unique and common rotor faults of permanent magnet synchronous motors, respectively. These important factors affect reliability and security of motor drive systems. Online monitoring and real-time diagnosis are typically required in highly reliable application scenarios. The influence of demagnetization and eccentricity faults on spatiotemporal distribution of stator tooth flux based on a stator magnetic flux detection device with multiple search coils is analyzed in this article by establishing a mathematical model of stator tooth flux with corresponding faults. Moreover, a method for extracting rotor fault features and formulating the corresponding fault diagnosis is proposed. Simulations and experiments showed that the proposed diagnosis method can effectively identify the corresponding fault type and diagnose the number of demagnetization poles, degree of demagnetization, and magnitude and orientation of eccentricity ratio. The proposed method can provide an important basis for the operation and maintenance of the motor, help reduce losses due to faults, and improve reliability of the motor and the entire system.
- 10 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (3) , 2366-2377
Online Rotor Fault Diagnosis of Permanent Magnet Synchronous Motors Based on Stator Tooth Flux
Demagnetization and eccentricity are unique and common rotor faults of permanent magnet synchronous motors, respectively. These important factors affect reliability and security of motor drive systems. Online monitoring and real-time diagnosis are typically required in highly reliable application scenarios. The influence of demagnetization and eccentricity faults on spatiotemporal distribution of stator tooth flux based on a stator magnetic flux detection device with multiple search coils is analyzed in this article by establishing a mathematical model of stator tooth flux with corresponding faults. Moreover, a method for extracting rotor fault features and formulating the corresponding fault diagnosis is proposed. Simulations and experiments showed that the proposed diagnosis method can effectively identify the corresponding fault type and diagnose the number of demagnetization poles, degree of demagnetization, and magnitude and orientation of eccentricity ratio. The proposed method can provide an important basis for the operation and maintenance of the motor, help reduce losses due to faults, and improve reliability of the motor and the entire system.
- Open Access
- 29 October 2017
- Published by Wiley in International Journal of Rotating Machinery
- Vol. 2017, 1-12
Influence of End Structure on Electromagnetic Forces on End Winding of a 1550 MW Nuclear Generator
A 3D electromagnetic model of the end region of a 1550 MW nuclear generator is set up. The electromagnetic forces on the involute and nose parts of the end winding under a rated operation are obtained through the 3D time-step finite element method. The electromagnetic forces on different coils in the same phase are analyzed. By changing the rotor’s relative length and stator coil’s linear length in the 3D electromagnetic model, the electromagnetic force distributions on the end winding are obtained. The influence of each structure change on the electromagnetic force in different directions is studied in detail. Conclusions that can be helpful in decreasing the electromagnetic forces on the end winding through optimizing the end region design are presented.
- 29 October 2017
- Published by Wiley in International Journal of Rotating Machinery
- Vol. 2017, 1-12
Open AccessInfluence of End Structure on Electromagnetic Forces on End Winding of a 1550 MW Nuclear Generator
A 3D electromagnetic model of the end region of a 1550 MW nuclear generator is set up. The electromagnetic forces on the involute and nose parts of the end winding under a rated operation are obtained through the 3D time-step finite element method. The electromagnetic forces on different coils in the same phase are analyzed. By changing the rotor’s relative length and stator coil’s linear length in the 3D electromagnetic model, the electromagnetic force distributions on the end winding are obtained. The influence of each structure change on the electromagnetic force in different directions is studied in detail. Conclusions that can be helpful in decreasing the electromagnetic forces on the end winding through optimizing the end region design are presented.
- Open Access
- 15 May 2017
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 19 (3) , 1745-1758
Feature extraction and fault diagnosis of wind power generator vibration signals based on empirical wavelet transform
Given the nonlinear and nonstationary characteristics of wind power generator vibration signals, the empirical wavelet transform (EWT)-based method is proposed to analyze the vibration signal characteristics and to diagnose faults. The adaptive Fourier spectrum segmentation of EWT is analyzed, and an appropriate wavelet filter is constructed to extract different AM-FM mode functions. The Hilbert transform is conducted, and the signal modal component energy is normalized to obtain vibration feature quantities. A probabilistic neural network (PNN) is used to perform the classification and diagnosis of wind power generator vibration faults. The experiments are constructed based on simulation signals and vibration signals before the proposed method and Hilbert-Huang transform (HHT) are used to perform mode decomposition and to analyze the time-frequency energy spectrum. The experimental results showed that the obtained resolution modes by EWT are within the corresponding time domain signal characteristics. The number of mode decomposition layers is less than that of empirical mode decomposition. No characteristics of false modal are observed. The time-frequency energy spectrum diagram can better reflect the characteristics of original vibration signal than the spectrum based on HHT. The PNN-based vibration fault judgment can achieve an accuracy rate of 90 % with limited training samples.
- 15 May 2017
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 19 (3) , 1745-1758
Open AccessFeature extraction and fault diagnosis of wind power generator vibration signals based on empirical wavelet transform
Given the nonlinear and nonstationary characteristics of wind power generator vibration signals, the empirical wavelet transform (EWT)-based method is proposed to analyze the vibration signal characteristics and to diagnose faults. The adaptive Fourier spectrum segmentation of EWT is analyzed, and an appropriate wavelet filter is constructed to extract different AM-FM mode functions. The Hilbert transform is conducted, and the signal modal component energy is normalized to obtain vibration feature quantities. A probabilistic neural network (PNN) is used to perform the classification and diagnosis of wind power generator vibration faults. The experiments are constructed based on simulation signals and vibration signals before the proposed method and Hilbert-Huang transform (HHT) are used to perform mode decomposition and to analyze the time-frequency energy spectrum. The experimental results showed that the obtained resolution modes by EWT are within the corresponding time domain signal characteristics. The number of mode decomposition layers is less than that of empirical mode decomposition. No characteristics of false modal are observed. The time-frequency energy spectrum diagram can better reflect the characteristics of original vibration signal than the spectrum based on HHT. The PNN-based vibration fault judgment can achieve an accuracy rate of 90 % with limited training samples.
- Open Access
Design and Simulation Test of an Open D-Dot Voltage Sensor
Nowadays, sensor development focuses on miniaturization and non-contact measurement. According to the D-dot principle, a D-dot voltage sensor with a new structure was designed based on the differential D-dot sensor with a symmetrical structure, called an asymmetric open D-dot voltage sensor. It is easier to install. The electric field distribution of the sensor was analyzed through Ansoft Maxwell and an open D-dot voltage sensor was designed. This open D-voltage sensor is characteristic of accessible insulating strength and small electric field distortion. The steady and transient performance test under 10 kV-voltage reported satisfying performances of the designed open D-dot voltage sensor. It conforms to requirements for a smart grid measuring sensor in intelligence, miniaturization and facilitation.
Open AccessDesign and Simulation Test of an Open D-Dot Voltage Sensor
Nowadays, sensor development focuses on miniaturization and non-contact measurement. According to the D-dot principle, a D-dot voltage sensor with a new structure was designed based on the differential D-dot sensor with a symmetrical structure, called an asymmetric open D-dot voltage sensor. It is easier to install. The electric field distribution of the sensor was analyzed through Ansoft Maxwell and an open D-dot voltage sensor was designed. This open D-voltage sensor is characteristic of accessible insulating strength and small electric field distortion. The steady and transient performance test under 10 kV-voltage reported satisfying performances of the designed open D-dot voltage sensor. It conforms to requirements for a smart grid measuring sensor in intelligence, miniaturization and facilitation.
- Open Access
- 1 January 2013
- Published by Walter de Gruyter GmbH in International Journal on Smart Sensing and Intelligent Systems
- Vol. 6 (1) , 297-316
A Wsn-Based On-Line Working Condition Monitoring System For Large Electrical Equipment
To solve the problems of traditional wired on-line monitoring system which has lines too much, cost too high, fault diagnosing and maintaining difficulties and so on, an on-line working condition monitoring system for large electrical equipment based on wireless sensor network (WSN) is proposed, designed and implemented. CC2431 chips were used for hardware design of wireless sensor network node and base station, and the TinyOS transplanted into the sensor nodes and base stations are discussed in detail. Then, a management software system based on LabVIEW and database programming technique is proposed and implemented. The experiment results show that the system can satisfy the needs for real-time data gathering, data storage, data curve drawing, low power consumption, wide coverage, no region limitation. It’s a good operation performance.
- 1 January 2013
- Published by Walter de Gruyter GmbH in International Journal on Smart Sensing and Intelligent Systems
- Vol. 6 (1) , 297-316
Open AccessA Wsn-Based On-Line Working Condition Monitoring System For Large Electrical Equipment
To solve the problems of traditional wired on-line monitoring system which has lines too much, cost too high, fault diagnosing and maintaining difficulties and so on, an on-line working condition monitoring system for large electrical equipment based on wireless sensor network (WSN) is proposed, designed and implemented. CC2431 chips were used for hardware design of wireless sensor network node and base station, and the TinyOS transplanted into the sensor nodes and base stations are discussed in detail. Then, a management software system based on LabVIEW and database programming technique is proposed and implemented. The experiment results show that the system can satisfy the needs for real-time data gathering, data storage, data curve drawing, low power consumption, wide coverage, no region limitation. It’s a good operation performance.
- 31 October 2012
- Published by AICIT in Progress in Intelligent Computing and Applications
- Vol. 1 (1) , 50-61
Dynamic Weighting for Effective Fusion of Fingerprint and Finger Vein
- 31 October 2012
- Published by AICIT in Progress in Intelligent Computing and Applications
- Vol. 1 (1) , 50-61
Dynamic Weighting for Effective Fusion of Fingerprint and Finger Vein
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 614-617
Novel Sensor System for Online Partial discharge (PD) Detecting on Insulator of Transmission Lines
There is defective insulator partial discharging (PD) phenomenon in high voltage transmission lines. High voltage online insulator detection can be realized by special ultraviolet sensor to detect the ultraviolet when discharging. This paper introduces this detective principle, and designs ultraviolet online detector based on this principle. The inspection on simulation of discharging spark proves the system highly sensitivity, perfect real time. And it can be utilized in the discharging detection of power system, transformer substation, etc.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 614-617
Novel Sensor System for Online Partial discharge (PD) Detecting on Insulator of Transmission Lines
There is defective insulator partial discharging (PD) phenomenon in high voltage transmission lines. High voltage online insulator detection can be realized by special ultraviolet sensor to detect the ultraviolet when discharging. This paper introduces this detective principle, and designs ultraviolet online detector based on this principle. The inspection on simulation of discharging spark proves the system highly sensitivity, perfect real time. And it can be utilized in the discharging detection of power system, transformer substation, etc.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21562318,p. 2230-2234
LADT Arithmetic Improved and Hardware Implemented for FPGA -Based ECG Data Compression
To resolve the problem of complex operation of the linear approximation distance threshold (LADT) algorithm, some improved researches were made to the algorithm by taking the characteristic of electrocardiograph (ECG) signal and the advantages of field programmable gate arrays (FPGA) into account. The paper puts forward a real time compression method with much less mathematical operation and much easier real-time implementation. With the artificial and experimental verification, it turned to be that the arithmetic has the advantages of low distortion and in real time. In the application of improved fast LADT algorithm, the paper designed the hardware system of ECG data compression based on FPGA and the program of the algorithm based on very high speed integrated circuit hardware description language (VHDL). And the experiment results of this system turned to be good performance. The approach can be easily extended to other similar applications.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21562318,p. 2230-2234
LADT Arithmetic Improved and Hardware Implemented for FPGA -Based ECG Data Compression
To resolve the problem of complex operation of the linear approximation distance threshold (LADT) algorithm, some improved researches were made to the algorithm by taking the characteristic of electrocardiograph (ECG) signal and the advantages of field programmable gate arrays (FPGA) into account. The paper puts forward a real time compression method with much less mathematical operation and much easier real-time implementation. With the artificial and experimental verification, it turned to be that the arithmetic has the advantages of low distortion and in real time. In the application of improved fast LADT algorithm, the paper designed the hardware system of ECG data compression based on FPGA and the program of the algorithm based on very high speed integrated circuit hardware description language (VHDL). And the experiment results of this system turned to be good performance. The approach can be easily extended to other similar applications.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 2136-2140
Real-Time ECG Monitoring System Based on FPGA
Existing remote monitoring systems are usually situated in a hospital off line and the cost of sending physiology data by computer is high and the data can only be used within one hospital. In this paper, a real-time electrocardiogram (ECG) monitoring system is proposed based on field programmable gate arrays (FPGA). The FPGA chip is taken as the central microprocessor and applies structured design on very high speed integrated circuit hardware description language (VHDL) to collect and transmit real-time ECG signals. The experiment shows that the ECG monitoring system has a good performance. The digital filtering and data compression arithmetics are also integrated in the FPGA chip. This monitoring system has the advantages of high integration density, powerful function, low cost and convenience to carry around.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 2136-2140
Real-Time ECG Monitoring System Based on FPGA
Existing remote monitoring systems are usually situated in a hospital off line and the cost of sending physiology data by computer is high and the data can only be used within one hospital. In this paper, a real-time electrocardiogram (ECG) monitoring system is proposed based on field programmable gate arrays (FPGA). The FPGA chip is taken as the central microprocessor and applies structured design on very high speed integrated circuit hardware description language (VHDL) to collect and transmit real-time ECG signals. The experiment shows that the ECG monitoring system has a good performance. The digital filtering and data compression arithmetics are also integrated in the FPGA chip. This monitoring system has the advantages of high integration density, powerful function, low cost and convenience to carry around.