EHElliot E. Hui

Elliot E. Hui

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Elliot E. Hui has a total of 131 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Microencapsulated tumor organoids maintain drug sensitivity stratification

    by Aarthi Namasivayam, Alica K. Michels, Christopher J. Halbrook, Elliot E. Hui

    Drug sensitivity stratification was largely preserved while reducing standard pancreatic cancer organoid culture volume by 100-fold.

  • Open Access

    An Isothermal Amplification Method for SARS-CoV-2 Variant Differentiation via Targeted Genomic RNA Detection

    by Alfonso Shin, Marc J. Madou, Lawrence Kulinsky, Elliot E. Hui, Rie Nakajima, Philip Felgner

    The rapid emergence of SARS-CoV-2 variants underscores the need for accurate, rapid, and affordable diagnostic tools, particularly in resource-limited settings. An isothermal amplification-based assay was developed integrating reverse-transcriptase recombinase polymerase amplification (RT-RPA), T7 transcription, and duplex-specific nuclease (DSN)-mediated detection for variant discrimination. The assay targets three genomic regions: a conserved region within ORF1a and two variant regions, ORF1a (Δ3675–3677) and the S gene (Δ69–70), enabling differentiation between the Wuhan-Hu-1 reference isolate and the B.1.1.7 variant. The method demonstrated high specificity and a limit of detection of 200 copies per sample using low-cost instrumentation. DSN-mediated cleavage improved discrimination between matched and mismatched RNA targets while enabling signal amplification through target recycling. The assay requires minimal laboratory infrastructure, relying on a heat block and fluorescent plate reader. These results demonstrate a scalable and cost-effective strategy for SARS-CoV-2 variant screening with potential as a future strategy for pathogen screening and variant surveillance.

  • Open Access

    Interfacial Tension Modulates Viscous Microfluidic Droplet Generation

    by Aarthi Namasivayam, Christopher J Halbrook, Elliot E Hui

    Mammalian cell culture in nanoliter droplets of extracellular matrix has recently attracted interest as a platform for high throughput drug screening on 3D tissue models. Microfluidic droplet generation using basement membrane extract, such as Matrigel or Cultrex, is complicated by the fact that the viscosity is orders of magnitude higher than that of water. Consequently, conditions that produce quality water droplet generation can fail with basement membrane extract due to the higher capillary number. Here, a parametric study using a T-junction device demonstrates that higher viscosity can be abrogated by lower interfacial tension, which is modulated by surfactant concentration.


  • Open Access

    Visualizing PIEZO1 localization and activity in hiPSC-derived single cells and organoids with HaloTag technology

    by Gabriella A. Bertaccini, Ignasi Casanellas, Elizabeth L. Evans, Jamison L. Nourse, George D. Dickinson, Gaoxiang Liu, Sayan Seal, Alan T. Ly, Jesse R. Holt, Tharaka D. Wijerathne, et al.

    PIEZO1 is critical to numerous physiological processes, transducing diverse mechanical stimuli into electrical and chemical signals. Recent studies underscore the importance of visualizing endogenous PIEZO1 activity and localization to understand its functional roles. To enable physiologically and clinically relevant studies on human PIEZO1, we genetically engineered human induced pluripotent stem cells (hiPSCs) to express a HaloTag fused to endogenous PIEZO1. Combined with advanced imaging, our chemogenetic platform allows precise visualization of PIEZO1 localization dynamics in various cell types. Furthermore, the PIEZO1-HaloTag hiPSC technology facilitates the non-invasive monitoring of channel activity across diverse cell types using Ca2+-sensitive HaloTag ligands, achieving temporal resolution approaching that of patch clamp electrophysiology. Finally, we use lightsheet microscopy on hiPSC-derived neural organoids to achieve molecular scale imaging of PIEZO1 in three-dimensional tissue. Our advances establish a platform for studying PIEZO1 mechanotransduction in human systems, with potential for elucidating disease mechanisms and targeted drug screening.


  • Open Access

    Visualizing PIEZO1 Localization and Activity in hiPSC-Derived Single Cells and Organoids with HaloTag Technology

    by Gabriella A. Bertaccini, Ignasi Casanellas, Elizabeth L. Evans, Jamison L. Nourse, George D. Dickinson, Gaoxiang Liu, Sayan Seal, Alan T. Ly, Jesse R. Holt, Tharaka D. Wijerathne, et al.

    PIEZO1 is critical to numerous physiological processes, transducing diverse mechanical stimuli into electrical and chemical signals. Recent studies underscore the importance of visualizing endogenous PIEZO1 activity and localization to understand its functional roles. To enable physiologically and clinically relevant studies on human PIEZO1, we genetically engineered human induced pluripotent stem cells (hiPSCs) to express a HaloTag fused to endogenous PIEZO1. Combined with advanced imaging, our chemogenetic platform allows precise visualization of PIEZO1 localization dynamics in various cell types. Furthermore, the PIEZO1-HaloTag hiPSC technology facilitates the non-invasive monitoring of channel activity across diverse cell types using Ca 2+ -sensitive HaloTag ligands, achieving temporal resolution approaching that of patch clamp electrophysiology. Finally, we used lightsheet imaging of hiPSC-derived neural organoids to achieve molecular scale imaging of PIEZO1 in three-dimensional tissue organoids. Our advances offer a novel platform for studying PIEZO1 mechanotransduction in human cells and tissues, with potential for elucidating disease mechanisms and targeted therapeutic development.


  • Open Access

    Approximation of Intractable Likelihood Functions in Systems Biology via Normalizing Flows

    by Vincent D. Zaballa, Elliot E. Hui

    Systems biology relies on mathematical models that often involve complex and intractable likelihood functions, posing challenges for efficient inference and model selection. Generative models, such as normalizing flows, have shown remarkable ability in approximating complex distributions in various domains. However, their application in systems biology for approximating intractable likelihood functions remains unexplored. Here, we elucidate a framework for leveraging normalizing flows to approximate complex likelihood functions inherent to systems biology models. By using normalizing flows in the Simulation-based inference setting, we demonstrate a method that not only approximates a likelihood function but also allows for model inference in the model selection setting. We showcase the effectiveness of this approach on real-world systems biology problems, providing practical guidance for implementation and highlighting its advantages over traditional computational methods.

    • 27 June 2023
    Open Access

    Stochastic Gradient Bayesian Optimal Experimental Designs for Simulation-based Inference.

    by Vincent D. Zaballa, Elliot E. Hui

    Simulation-based inference (SBI) methods tackle complex scientific models with challenging inverse problems. However, SBI models often face a significant hurdle due to their non-differentiable nature, which hampers the use of gradient-based optimization techniques. Bayesian Optimal Experimental Design (BOED) is a powerful approach that aims to make the most efficient use of experimental resources for improved inferences. While stochastic gradient BOED methods have shown promising results in high-dimensional design problems, they have mostly neglected the integration of BOED with SBI due to the difficult non-differentiable property of many SBI simulators. In this work, we establish a crucial connection between ratio-based SBI inference algorithms and stochastic gradient-based variational inference by leveraging mutual information bounds. This connection allows us to extend BOED to SBI applications, enabling the simultaneous optimization of experimental designs and amortized inference functions. We demonstrate our approach on a simple linear model and offer implementation details for practitioners.

  • Open Access

    Pneumatic computers for embedded control of microfluidics

    by Siavash Ahrar, Manasi Raje, Irene C. Lee, Elliot E. Hui

    Alternative computing approaches that interface readily with physical systems are well suited for embedded control of those systems. We demonstrate finite state machines implemented as pneumatic circuits of microfluidic valves and use these controllers to direct microfluidic liquid handling procedures on the same chip. These monolithic integrated systems require only power to be supplied externally, in the form of a vacuum source. User input can be provided directly to the chip by covering pneumatic ports with a finger. State machines with up to four bits of state memory are demonstrated, and next-state combinational logic can be fully reprogrammed by changing the hole-punch pattern on a membrane in the chip. These pneumatic computers demonstrate a framework for the embedded control of physical systems and open a path to stand-alone lab-on-a-chip devices capable of highly complex functionality.


  • Open Access

    Phase-Optimized Peristaltic Pumping by Integrated Microfluidic Logic

    by Erik M. Werner, Benjamin X. Lam, Elliot E. Hui

    Microfluidic droplet generation typically entails an initial stabilization period on the order of minutes, exhibiting higher variation in droplet volume until the system reaches monodisperse production. The material lost during this period can be problematic when preparing droplets from limited samples such as patient biopsies. Active droplet generation strategies such as antiphase peristaltic pumping effectively reduce stabilization time but have required off-chip control hardware that reduces system accessibility. We present a fully integrated device that employs on-chip pneumatic logic to control phase-optimized peristaltic pumping. Droplet generation stabilizes in about a second, with only one or two non-uniform droplets produced initially.


  • Open Access

    Fabrication of Multilayer Molds by Dry Film Photoresist

    by Narek E. Koucherian, Shijun Yan, Elliot E. Hui

    Dry film photoresists are widely employed to fabricate high-aspect-ratio microstructures, such as molds for microfluidic devices. Unlike liquid resists, such as SU-8, dry films do not require a cleanroom facility, and it is straightforward to prepare uniform and reproducible films as thick as 500 µm. Multilayer patterning, however, can be problematic with dry film resists even though it is critical for a number of microfluidic devices. Layer-to-layer mask alignment typically requires the first layer to be fully developed, making the pattern visible, before applying and patterning the second layer. While a liquid resist can flow over the topography of previous layers, this is not the case with dry film lamination. We found that post-exposure baking of dry film photoresists can preserve a flat topography while revealing an image of the patterned features that is suitable for alignment to the next layer. We demonstrate the use of this technique with two different types of dry film resist to fabricate master molds for a hydrophoresis size-sorting device and a cell chemotaxis device.