BYBilal Yasa

Bilal Yasa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bilal Yasa has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Beyazlatma Özellikli Bir Diş Macununun İn Vitro Olarak Değerlendirilmesi

    by Dilan Kopuz, Elif Alkan, Neslihan Tekçe, Osman Hayran, Zeynep Bilge Kütük, Bilal Yaşa, Bora Korkut, Dilek Tağteki̇n, Funda Yanikoğlu

    Amaç: Beyazlatıcı içerikli deneysel diş macununun, minedeki renk değişimine ve yüzey pürüzlülüğüne olan etkisini değerlendirmektir. Gereç ve Yöntemler: Çalışmada 30-adet sağlam, çürüksüz, boyutları birbirine yakın daimi dişler kullanıldı. Dişler rastgele olarak 6 deneysel gruba ayrıldı (n=5); Grup 1: Beyazlatıcı ajan içeren deneysel diş macunu (Zubio Test-1, Dar Kozmetik, İstanbul, Türkiye); Grup 2: Beyazlatıcı ajan içeren deneysel diş macunu (Zubio Test-2); Grup 3: Beyazlatıcı ajan içeren diş macunu (İpana 3D White luxe, İpana P&G, ABD); Grup 4: Bitkisel içerikli bir diş macunu (Gumgumix, Beka ilaç, İstanbul, Türkiye); Grup 5: Kahvede bekletilen; Grup 6: Suda bekletilen. Tüm örneklerden 3 farklı zaman aralığında (T1-T2-T3) renk ve yüzey pürüzlülüğü ölçümleri yapıldı. T1: Tüm örnekler 24-saat kahvede bekletildikten ve renklenmeleri sağlandıktan sonra; T2: Her gün 15 dakika (3 kez-5’er dakika) kahvede bekleme ve 10 saniye (2 kez-10’ar saniye) fırçalama işlemi yaptıktan 7 gün sonra; T3: Her gün 15 dakika (3 kez-5’er dakika) kahvede bekleme ve 10 saniye (2 kez-10’ar saniye) fırçalama işlemi yaptıktan 14 gün sonrayı göstermektedir. Veriler Kruskal-Wallis ve Friedman istatistik testleri ile değerlendirildi (P=0.05). Bulgular: Tüm test gruplarında renk değişimi görüldü ancak test gruplarının aralarında farklılıklar oluşmadı (P>0.05). Grup 2, sayısal olarak olumlu yönde en büyük değişimi oluştururken, diğer gruplarla arasında istatistiksel bir farklılık ortaya çıkarmadı. Zubio Test-2 diş macununun beyazlatıcı etkisi İpana 3D White luxe ve Gumgumix diş macunları ile benzer bulundu. 14 günlük araştırmanın sonucunda Zubio Test-2, Test-1’e göre daha yüksek yüzey pürüzlülük değerleri sergiledi. Sonuç: Zubio Test-2’nin, kahvenin neden olacağı renklenmeye karşı geleneksel beyazlatıcı diş macununa benzer koruyucu etki göstererek, renklenmeyi önleyici yönde etkili olabileceği söylenebilir.

  • Open Access

    Comparison of Different Restoration Techniques for Endodontically Treated Teeth

    by Jusuf Lukarcanin, İsmail Serhat Sadıkoğlu, Bilal Yaşa, Lezize Şebnem Türkün, Murat Türkün

    The aim of the present study is to evaluate the physical properties of endodontically treated teeth restored with five different restorative techniques and materials. Hundred and forty extracted human molar teeth were used. In addition to five restoration groups, specimens with no restorations were used as the negative control, and intact molar teeth were used as the positive control. For flexural strength tests, material specimens were made from 5 different materials using a mould according to ISO 4049 standards. One-way ANOVA revealed that the fracture resistance was significantly affected by the restoration type. SFRC group showed the best fracture resistance values, while lowest values were seen in the GWF group. The test results of flexural strength showed values between 140 and 184 MPa and modulus of elasticity between 6.33 and 18.89 GPa ( ). Under the limits of this study, results showed that SFRC can be used to increase the fracture resistance of ETT.


  • Clinical effects of dehydration on tooth color: How much and how long?

    by Hüseyin Hatırlı, Emine Şirin Karaarslan, Bilal Yaşa, Enes Kılıç, Ayla Yaylacı

    Objective: To evaluate effects of dehydration on tooth color determine whether color returns to baseline after 30 min or 24 h.Materials and methods: Thirty participants with intact maxillary central and lateral incisors were recruited for the study. Color measurements were performed with a spectrophotometer (SpectroShade Micro) at baseline and at 10, 20, and 30 min of dehydration, as well as 30 min and 24 h of rehydration. CIEDE2000 color parameters were used to calculate color difference. The data were analyzed for color changes over time by repeated‐measures analysis of variance (ANOVA), and the Bonferroni‐Tukey test was used for post‐ANOVA comparisons (P < .05).Results: After 30 min of dehydration, all the tested teeth were above the perceptibility threshold (ΔE00 = 0.8), and 85% of the teeth were above the acceptability threshold (ΔE00 = 1.8). After 30 min of rehydration, 78.3% of the tested teeth were above the perceptibility threshold, and 31.6% of the teeth were above the acceptability threshold. After 24 h of rehydration, 99.2% of the teeth were below the acceptability threshold, and 90% of the values were below the perceptibility threshold.Conclusions: Thirty‐minute tooth dehydration can result in a clinically significant color change. After a 24‐h rehydration period, reliable color assessment can be performed.Clinical significance: Tooth dehydration causes significant color change, thus assessment of final color or clinical success should be considered after tooth rehydration for esthetic restorations and tooth bleaching.


  • Can we restore the colour of long‐term discoloured resin composites by noninvasive methods?

    by Cigdem Atalayin Ozkaya, Bilal Yasa, Ali Osman Demirhan, Lezize Sebnem Turkun

    The aim of this study is to investigate the effect of toothbrushing and paste repolishing on the colour restitution of long‐term coffee discoloured prefabricated and direct resin composites. One prefabricated (Componeer‐Coltène) and three direct resin composites (Brilliant Ever Glow‐Coltène, Essentia‐GC, Harmonize‐Kerr) were tested. Componeer samples were prepared with and without polishing while the other groups were all polished. After baseline colour‐measurement, the specimens were immersed in coffee for 3‐month and colour‐measurement was repeated, then a simulation of 1‐year of toothbrushing (Toothbrush Simulation ZM‐3.4‐SD Mechatronics) with Pro‐Expert Professional Protection‐Ipana, 3D White Luxe Perfection‐Ipana, and White Ruscello‐GC toothpaste was performed. Colour‐changes (ΔE) after toothbrushing and repolishing with polishing paste (Enamelize, Cosmodent) were calculated. The discolouration occurred after prolonged exposure to a coffee solution was above the clinically acceptable level of ΔE = 2 in all groups, except Componeer polished group. The lowest discoloured group was Componeer polished (ΔE = 1.66 ± 0.32) while the highest was Essentia group (ΔE = 4.30 ± 0.48). The samples toothbrushed with White Ruscello exhibited the greatest colour restitution (ΔE = 2.06 ± 0.75) (P < .05). After paste repolishing, slight colour restitution was observed among all the groups, but the differences between them remained the same as after the toothbrushing procedure. Prolonged exposure to coffee solution affects the colour of the resin composites and noninvasive methods can provide colour restitution below the critical value for visual perception (ΔE = 3.3). Noninvasive procedures such as toothbrushing with a whitening toothpaste or repolishing with a polishing paste may ensure the colour restitution of direct resin composite restorations until a clinically acceptable level.


  • Evaluation of the Radiopacities of Bulk-fill RestorativesUsing Two Digital Radiography Systems

    by E Yasa, B Yasa, Os Aglarci, Et Ertas

    SUMMARY: This study investigated the radiopacity values of bulk-fill restoratives by using two digital radiography systems. Nine bulk-fill restoratives and a conventional composite were used in the study. Six disc-shaped specimens were prepared from each of these materials, three each at thicknesses of 1 mm and 2 mm, and tooth slices with these same thicknesses were obtained. As a control, an aluminum step wedge varying in thickness from 0.5 to 10 mm in was used. Three specimens of each of the materials, together with the tooth slice and the aluminum step wedge, were placed over a complementary metal oxide semiconductor (CMOS) sensor and a storage photostimulable phosphor (PPS) plate system and exposed using a dental x-ray unit. The images were analyzed using a software program to measure the mean gray values (MGVs). Five measurements were obtained from each of the restorative materials, the enamel, the dentin, and the stepwedge. The MGVs were converted to the equivalent aluminum thicknesses. Three-way analysis of variance (ANOVA) was used to determine the significance of the differences among the groups. A Tukey test was applied for pairwise comparisons (p<0.05). All composite-based restoratives were found to have greater radiopacities than enamel or dentin. Equia Fil had the lowest radiopacity value. Radiopacity increased as the thicknesses of the restorative material increased. The CMOS system showed significantly higher radiopacity values than the PSP system. In conclusion, all investigated bulk-fill restoratives passed the International Organization for Standardization and American National Standard Institute/American Dental Association requirements for radiopacity values when evaluated with the two digital radiography systems.


  • Effects of different orthodontic primers on enamel demineralization around orthodontic brackets

    by A. Baysal, B. Yasa, O. Sogut, M.A. Ozturk, T. Uysal

    The purpose of this work is to evaluate the effectiveness of one self-etching and two filled orthodontic primers on enamel demineralization around orthodontic brackets. Brackets were bonded to 84 bovine teeth and the vestibular enamel surfaces covered with acid-resistant nail varnish exposing 1 mm of space on each side of the bracket base. The teeth were allocated to four groups, using either Transbond™ XT conventional primer on etched enamel (group 1), Transbond™ Plus Self-Etching Primer on untreated enamel (group 2), Pro Seal® filled resin primer on etched enamel (group 3), or Opal Seal® filled resin primer on etched enamel (group 4). Each tooth was subjected to 15,000 strokes of brushing followed by exposure to an acid challenge. Calcium-ion release from each sample was calculated using atomic absorption spectrophotometry. Data were analyzed using one-way ANOVA and a post hoc Tukey test. Differences were considered statistically significant at p ≤ 0.05. Statistically significant differences were observed between the four groups (p < 0.001). No significant difference was found between the controls (group 1) and the Opal Seal® group. Higher calcium release was observed in the Pro Seal® group and the self-etching primer group compared to the controls. The highest calcium release was recorded in the self-etching primer group. Filled sealants may not have a protective effect against enamel demineralization. Transbond™ Plus Self-Etching Primer should be used cautiously, considering the risk of demineralization involved in its application. Auswertung eines selbstätzenden und zweier gefüllter kieferorthopädischer Haftvermittler auf ihre Wirksamkeit gegen Schmelzdemineralisationen im Umfeld von Brackets. Brackets wurden auf 84 Rinderzähne geklebt, und die vestibulären Schmelzflächen wurden – unter Aussparung von 1 mm Platz an allen Seiten der Bracketbasis – mit säurefestem Nagellack überzogen. Die Einteilung der Zähne in 4 Gruppen umfasste als Gruppe 1 eine Kontrollgruppe mit konventionellem, auf den angeätzten Schmelz applizierten Haftvermittler (Transbond™ XT). In Gruppe 2 wurden auf den unbehandelten Schmelz ein selbstätzender Haftvermittler (Transbond™ Plus) und in den Gruppen 3 und 4 auf den angeätzten Schmelz jeweils ein gefüllter Kunststoffhaftvermittler mit Fluoridabgabe (Pro Seal® und Opal Seal®) appliziert. Jeder Zahn wurde mit 15.000 Bürstenstrichen behandelt, danach einem Säurereiz ausgesetzt und per Atomabsorptionsspektroskopie auf die Freisetzung von Kalziumionen beurteilt. Zur statistischen Auswertung (Signifikanzniveau p ≤ 0,05) diente eine Einwegvarianzanalyse und ein Post-hoc-Tukey-Test. Zwischen den 4 Gruppen fanden sich signifikante Unterschiede (p < 0,001). Kein signifikanter Unterschied ergab sich zwischen Gruppe 1 (Kontrollgruppe) und Gruppe 4 (Opal Seal®). In den Gruppen 2 (selbstätzender Haftvermittler) und 3 (Pro Seal®) lag die Kalziumfreisetzung höher als in der Kontrollgruppe. Am höchsten war sie in Gruppe 2 (selbstätzender Haftvermittler). Möglicherweise bieten gefüllte Versiegler keinen Schutz gegen Schmelzdemineralisationen. Bei Anwendung des selbstätzenden Haftvermittlers (Transbond™ Plus) ist Vorsicht geboten und das Demineralisationsrisiko zu bedenken.


  • Effect of novel restorative materials and retention slots on fracture resistance of endodontically-treated teeth

    by Bilal Yasa, Hakan Arslan, Elif Yasa, Merve Akcay, Huseyin Hatirli

    The aim of this study was to evaluate the fracture resistance of endodontically-treated teeth restored with nano-hybrid composite resin, bulk-fill flowable and short fibre-reinforced-composite in the absence/presence of retention slots. One hundred and ten extracted non-carious human mandibular molars received endodontic treatment followed by mesio-occlusodistal (MOD) cavities with 3 ± 0.2 mm thicknesses of buccal and lingual walls. Teeth were divided into two main groups according to the retention slot preparation. The dove-tail retention slots were prepared on the middle of opposite buccal and lingual walls to create mechanical interlocking. Each group was further divided into four sub-groups according to restorative material types: control (no restoration), nano-hybrid composite resin (Filtek™ Z550), bulk-fill flowable (Filtek™ Bulk Fill) and short fibre-reinforced-composite (everX Posterior™). Restored teeth were subjected to compressive load at a strain rate of 1 mm/min. The data were statistically analysed using two-way ANOVA and Tukey's test for multiple comparisons. The fracture resistance was significantly affected by the presence of the retentive slots and restorative material (p < 0.05). Restored teeth with retentive slots significantly increased the fracture resistance compared with restored teeth without retentive slots (p < 0.05). Short fibre-reinforced-composite with retentive slot cavities had significantly higher fracture resistance values compared with the other test groups (p < 0.05). The preparation of retention slots may increase the fracture resistance of endodontically-treated teeth, especially, when restored with short fibre-reinforced composite. The use of short fibre-reinforced composite with retentive slots could be an alternative technique to prevent cuspal fracture on endodontically-treated teeth with MOD cavity.


  • Open Access

    Effects of pulp capping materials on fracture resistance of Class II composite restorations

    by Ebru Kucukyilmaz, Bilal Yasa, Merve Akcay, Selcuk Savas, Fevzi Kavrik

    Objective: The aim of this study was to investigate the effect of cavity design and the type of pulp capping materials on the fracture resistance of Class II composite restorations. Materials and Methods: Sixty freshly extracted, sound molar teeth were selected for the study. A dovetail cavity on the mesio-occlusal and a slot cavity on disto-occlusal surfaces of each tooth were prepared, and the teeth were divided 4 groups which one of them as a control group. The pulp capping materials (TheraCal LC, Calcimol LC, Dycal) applied on pulpo-axial wall of each cavity, and the restoration was completed with composite resin. The teeth were subjected to a compressive load in a universal mechanical testing machine. The surfaces of the tooth and restoration were examined under a stereomicroscope. The data were analyzed using factorial analysis of variance and Tukey's test. Results: For pulp capping materials, the highest fracture load (931.15 ± 203.81 N) and the lowest fracture load (832.28 ± 245.75 N) were calculated for Control and Dycal group, respectively. However, there were no statistically significant differences among all groups (P > 0.05). The fracture load of the dovetail groups was significantly higher than those of the slot cavity groups (P < 0.05). Conclusion: Dovetail cavity design shows better fracture resistance in Class II composite restorations, independent of used or not used pulp capping materials.


  • Comparative study of radiopacity of resin-based and glass ionomer-based bulk-fill restoratives using digital radiography

    by Bilal Yasa, Ebru Kucukyilmaz, Elif Yasa, Elif T. Ertas

    This study investigated the radiopacity values of glass ionomer- and resin-based bulk-fill restoratives of different thicknesses using digital radiography. Two glass ionomer-based and three resin-based bulk-fill restoratives, and a conventional composite were studied. Five disc-shaped specimens were prepared from each of these materials at three different thicknesses; specimens of enamel and dentin with the same thicknesses were also prepared. Materials were placed over a complementary metal oxide-semiconductor sensor together with the tooth specimen and an aluminum step-wedge, and then exposed using a dental X-ray unit. The images were analyzed using a software program to measure the mean gray values (MGVs), which were converted to equivalent aluminum thicknesses. Two-way ANOVA was used to investigate the significance of differences among the groups. The GCP Glass Fill specimens showed the lowest radiopacity values, and the Quixfil specimens had the highest values. All materials had higher radiopacity values than enamel and dentin, except for GCP Glass Fill, which had a radiopacity similar to that of enamel. The resin-based bulk-fill restoratives had significantly higher radiopacity values than glass ionomer-based restoratives. All of the tested materials showed radiopacity values higher than that of dentin, as recommended by the ISO.