Alan T. Chiem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alan T. Chiem has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
George Lim
Ronald Reagan UCLA Medical Center California Los Angeles USA
3 shared publicationsElena Stark
David Geffen School of Medicine at UCLA, Los Angeles, California, USA
2 shared publications- Jacqueline Shibata
Department of Emergency Medicine, David Geffen School of Medicine at UCLA, Olive View‐UCLA Medical Center, Los Angeles, USA
2 shared publications John Christian Fox
2 shared publications- Vi Am Dinh
Loma Linda University Medical Center, Department of Emergency Medicine, Loma Linda, California
2 shared publications Abraham Pera
1 shared publication
Latest Publications
- 3 August 2025
- Published by Springer Nature
- p. 57-88
Advanced Cardiac Ultrasound
- 5 March 2023
- Published by Wiley in Australasian Journal of Ultrasound in Medicine
- Vol. 26 (2) , 91-99
Using tele‐ultrasound to teach medical students: A randomised control equivalence study
Objectives: Undergraduate ultrasound education is becoming increasingly important, but its expansion is limited by time, space and the availability of trained faculty. In order to validate an alternative and more accessible teaching model, our aim was to assess whether combining teleguidance and peer‐assisted learning to teach ultrasound is as effective as traditional in‐person methods.Methods: Peer instructors taught 47 second‐year medical students ocular ultrasound via either teleguidance or traditional in‐person methods. Proficiency was assessed using a multiple‐choice knowledge test and objective structured clinical examination (OSCE). Confidence, overall experience, and experience with a peer instructor were measured using a 5‐point Likert scale. Two one‐sided t‐tests were used to measure equivalency between the two groups. The null hypothesis that the two groups were not different was rejected when P < 0.05.Results: The teleguidance group performed as well as the traditional in‐person group in terms of knowledge change, confidence change, OSCE time and OSCE score (p = 0.011, p = 0.006, p = 0.005 and = 0.004, respectively, indicating the two groups are statistically equivalent). The teleguidance group rated the experience highly overall (4.06/5), but less than the traditional group (4.47/5; P = 0.448, indicating statistical difference). Peer instruction was rated 4.35/5 overall.Conclusion: Peer‐instructed teleguidance was equivalent to in‐person instruction with respect to knowledge change, confidence gain and OSCE performance in basic ocular ultrasound.
- 5 March 2023
- Published by Wiley in Australasian Journal of Ultrasound in Medicine
- Vol. 26 (2) , 91-99
Using tele‐ultrasound to teach medical students: A randomised control equivalence study
Objectives: Undergraduate ultrasound education is becoming increasingly important, but its expansion is limited by time, space and the availability of trained faculty. In order to validate an alternative and more accessible teaching model, our aim was to assess whether combining teleguidance and peer‐assisted learning to teach ultrasound is as effective as traditional in‐person methods.Methods: Peer instructors taught 47 second‐year medical students ocular ultrasound via either teleguidance or traditional in‐person methods. Proficiency was assessed using a multiple‐choice knowledge test and objective structured clinical examination (OSCE). Confidence, overall experience, and experience with a peer instructor were measured using a 5‐point Likert scale. Two one‐sided t‐tests were used to measure equivalency between the two groups. The null hypothesis that the two groups were not different was rejected when P < 0.05.Results: The teleguidance group performed as well as the traditional in‐person group in terms of knowledge change, confidence change, OSCE time and OSCE score (p = 0.011, p = 0.006, p = 0.005 and = 0.004, respectively, indicating the two groups are statistically equivalent). The teleguidance group rated the experience highly overall (4.06/5), but less than the traditional group (4.47/5; P = 0.448, indicating statistical difference). Peer instruction was rated 4.35/5 overall.Conclusion: Peer‐instructed teleguidance was equivalent to in‐person instruction with respect to knowledge change, confidence gain and OSCE performance in basic ocular ultrasound.
- Open Access
- 20 July 2021
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 8 (5) , 3997-4006
Feasibility of Patient-Performed Lung Ultrasound Self-Exams (Patient-PLUS) as a Potential Approach to Telemedicine in Heart Failure
Aims: Patient-performed lung ultrasound (LUS) in a heart failure (HF) telemedicine model may be used to monitor worsening pulmonary oedema and to titrate therapy, potentially reducing HF admission. The aim of the study was to assess the feasibility of training HF patients to perform a LUS self-exam in a telemedicine model. Methods and results: A pilot study was conducted at a public hospital involving subjects with a history of HF. After a 15 min training session involving a tutorial video, subjects performed a four-zone LUS using a handheld ultrasound. Exams were saved on a remote server and independently reviewed by two LUS experts. Studies were determined interpretable according to a strict definition: the presence of an intercostal space, and the presence of A-lines, B-lines, or both. Subjects also answered a questionnaire to gather feedback and assess self-efficacy. The median age of 44 subjects was 53 years (range, 36–64). Thirty (68%) were male. Last educational level attained was high school or below for 31 subjects (70%), and one-third used Spanish as their preferred language. One hundred fifty of 175 lung zones (85%) were interpretable, with expert agreement of 87% and a kappa of 0.49. 98% of subjects reported that they could perform this LUS self-exam at home. Conclusions: This pilot study reports that training HF patients to perform a LUS self-exam is feasible, with reported high self-efficacy. This supports further investigation into a telemedicine model using LUS to reduce emergency department visits and hospitalizations associated with HF.
- 20 July 2021
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 8 (5) , 3997-4006
Open AccessFeasibility of Patient-Performed Lung Ultrasound Self-Exams (Patient-PLUS) as a Potential Approach to Telemedicine in Heart Failure
Aims: Patient-performed lung ultrasound (LUS) in a heart failure (HF) telemedicine model may be used to monitor worsening pulmonary oedema and to titrate therapy, potentially reducing HF admission. The aim of the study was to assess the feasibility of training HF patients to perform a LUS self-exam in a telemedicine model. Methods and results: A pilot study was conducted at a public hospital involving subjects with a history of HF. After a 15 min training session involving a tutorial video, subjects performed a four-zone LUS using a handheld ultrasound. Exams were saved on a remote server and independently reviewed by two LUS experts. Studies were determined interpretable according to a strict definition: the presence of an intercostal space, and the presence of A-lines, B-lines, or both. Subjects also answered a questionnaire to gather feedback and assess self-efficacy. The median age of 44 subjects was 53 years (range, 36–64). Thirty (68%) were male. Last educational level attained was high school or below for 31 subjects (70%), and one-third used Spanish as their preferred language. One hundred fifty of 175 lung zones (85%) were interpretable, with expert agreement of 87% and a kappa of 0.49. 98% of subjects reported that they could perform this LUS self-exam at home. Conclusions: This pilot study reports that training HF patients to perform a LUS self-exam is feasible, with reported high self-efficacy. This supports further investigation into a telemedicine model using LUS to reduce emergency department visits and hospitalizations associated with HF.
- 1 February 2021
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 40 (2) , 391-396
A Call for Clinically Oriented Point-of-Care Ultrasound Research in COVID-19
- 1 February 2021
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 40 (2) , 391-396
A Call for Clinically Oriented Point-of-Care Ultrasound Research in COVID-19
- Open Access
- 3 October 2020
- Published by Wiley in AEM Education and Training
- Vol. 5 (1) , 99-101
Ultrasound Treasure Hunt: A Novel Teaching Method That Overcomes Direct Patient Care Restrictions Brought on by the COVID‐19 Pandemic
Prioritizing trainee safety during the COVID‐19 era is paramount. In March 2020, the AAMC recommended prohibiting medical students from direct patient care in significantly affected regions. Guidelines continue evolving; however, the AMA continues to recommend clinical experiences, not requiring direct patient care, be achieved through virtual formats.
- 3 October 2020
- Published by Wiley in AEM Education and Training
- Vol. 5 (1) , 99-101
Open AccessUltrasound Treasure Hunt: A Novel Teaching Method That Overcomes Direct Patient Care Restrictions Brought on by the COVID‐19 Pandemic
Prioritizing trainee safety during the COVID‐19 era is paramount. In March 2020, the AAMC recommended prohibiting medical students from direct patient care in significantly affected regions. Guidelines continue evolving; however, the AMA continues to recommend clinical experiences, not requiring direct patient care, be achieved through virtual formats.
- 18 June 2020
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 40 (1) , 175-181
A Novel Three‐Dimensional‐Printed Ultrasound‐Guided Hip Arthrocentesis Model
When evaluating patients with hip pain, clinicians may be trained to both evaluate for a hip effusion and perform ultrasound‐guided arthrocentesis to evaluate the etiology of the effusion. We present a novel 3‐dimensional‐printed hip arthrocentesis model, which can be used to train clinicians to perform both tasks under ultrasound guidance. Our model uses a combination of a 3‐dimensional‐printed hip joint, as well as readily available materials such as an infant Ambu (Ballerup, Denmark) bag, syringe, intravenous line kit, and silicone. We present our experience so that others may use and adapt our model for their training purposes.
- 18 June 2020
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 40 (1) , 175-181
A Novel Three‐Dimensional‐Printed Ultrasound‐Guided Hip Arthrocentesis Model
When evaluating patients with hip pain, clinicians may be trained to both evaluate for a hip effusion and perform ultrasound‐guided arthrocentesis to evaluate the etiology of the effusion. We present a novel 3‐dimensional‐printed hip arthrocentesis model, which can be used to train clinicians to perform both tasks under ultrasound guidance. Our model uses a combination of a 3‐dimensional‐printed hip joint, as well as readily available materials such as an infant Ambu (Ballerup, Denmark) bag, syringe, intravenous line kit, and silicone. We present our experience so that others may use and adapt our model for their training purposes.
- 1 February 2020
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 38 (2) , 173-177
Effect of insonation angle on peak systolic velocity variation
- 1 February 2020
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 38 (2) , 173-177
Effect of insonation angle on peak systolic velocity variation
- 21 May 2018
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 38 (1) , 253-258
A National Point‐of‐Care Ultrasound Competition for Medical Students
- 21 May 2018
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 38 (1) , 253-258
A National Point‐of‐Care Ultrasound Competition for Medical Students
- Open Access
- 4 October 2017
- Published by Springer Nature in The Ultrasound Journal
- Vol. 9 (1) , 1-3
Time to correct the flow of corrected flow time
Recently published study of Ma et al. evaluates two relatively novel measures of fluid responsiveness, carotid blood flow and corrected carotid flow time (ccFT). Both measures have been recently quoted as possibly useful, technically simple, and noninvasive dynamic tools in predicting fluid responsiveness. Recently, more research interest has been focused on ccFT and, intrigued by the data presented in this study, we discuss here the impact of the data presented in the paper of Ma et al. to the significance of this metric as a potential tool in the assessment of fluid responsiveness.
- 4 October 2017
- Published by Springer Nature in The Ultrasound Journal
- Vol. 9 (1) , 1-3
Open AccessTime to correct the flow of corrected flow time
Recently published study of Ma et al. evaluates two relatively novel measures of fluid responsiveness, carotid blood flow and corrected carotid flow time (ccFT). Both measures have been recently quoted as possibly useful, technically simple, and noninvasive dynamic tools in predicting fluid responsiveness. Recently, more research interest has been focused on ccFT and, intrigued by the data presented in this study, we discuss here the impact of the data presented in the paper of Ma et al. to the significance of this metric as a potential tool in the assessment of fluid responsiveness.
- Open Access
- 1 November 2016
- Published by Western Journal of Emergency Medicine in Western Journal of Emergency Medicine
- Vol. 17 (6) , 819-821
Role of Ultrasound in the Identi cation of Longitudinal Axis in Soft-Tissue Foreign Body Extraction
Identification and retrieval of soft tissue foreign bodies (STFBs) poses significant challenges in the emergency department. Prior studies have demonstrated the utility of ultrasound in identification and retrieval of STFBs, including radiolucent objects such as wood. We present a case of STFB extraction that utilizes ultrasound to identify the longitudinal axis of the object. With the longitudinal axis identified, the foreign body can be excised by making an incision where the foreign body is closest to the skin. The importance of this technique as it pertains to minimizing surrounding tissue destruction and discomfort for patients has not been previously reported.
- 1 November 2016
- Published by Western Journal of Emergency Medicine in Western Journal of Emergency Medicine
- Vol. 17 (6) , 819-821
Open AccessRole of Ultrasound in the Identi cation of Longitudinal Axis in Soft-Tissue Foreign Body Extraction
Identification and retrieval of soft tissue foreign bodies (STFBs) poses significant challenges in the emergency department. Prior studies have demonstrated the utility of ultrasound in identification and retrieval of STFBs, including radiolucent objects such as wood. We present a case of STFB extraction that utilizes ultrasound to identify the longitudinal axis of the object. With the longitudinal axis identified, the foreign body can be excised by making an incision where the foreign body is closest to the skin. The importance of this technique as it pertains to minimizing surrounding tissue destruction and discomfort for patients has not been previously reported.