Chun-Yu Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chun-Yu Chen has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Hsin-Fei Meng
Department of Physics Institute of Physics and Center for Emergent Functional Matter Science National Yang Ming Chiao Tung University Hsinchu Taiwan, Republic of China
2 shared publications - Yu-Chiang Chao
Department of Physics, National Taiwan Normal University, Taipei, 11677, Taiwan
2 shared publications - Cheryl C. H. Yang
Institute of Brain Science, National Yang Ming Chiao Tung University, Taipei, Taiwan
1 shared publication Ching-Jung Lai
Institute of Physiological and Anatomical Medicine, Tzu Chi University, Hualien
1 shared publication- Han-Ping Wu
College of Medicine, Chang Gung University, Taoyuan 333, Taiwan
1 shared publication - Hsiao-Wen Zan
National Yang Ming Chiao Tung University Department of Photonic Hsinchu
1 shared publication
Latest Publications
- Open Access
- 11 May 2017
- Published by Wiley in BioMed Research International
- Vol. 2017, 1-8
Predictors of Extracorporeal Membrane Oxygenation Support for Children with Acute Myocarditis
The clinical presentation of acute myocarditis in children may range from asymptomatic to sudden cardiac arrest. This study analyzed the clinical spectrum of acute myocarditis in children to identify factors that could aid primary care physicians to predict the need for extracorporeal membrane oxygenation (ECMO) earlier and consult the pediatric cardiologist promptly. Between October 2011 and September 2016, we retrospectively analyzed 60 patients aged 18 years or younger who were admitted to our pediatric emergency department with a definite diagnosis of acute myocarditis. Data on demographics, presentation, laboratory tests, electrocardiogram and echocardiography findings, treatment modalities, complications, and long-term outcomes were obtained. During the study period, 60 patients (32 male, 28 female; mean age, years) were diagnosed with acute myocarditis. Fever, cough, and chest pain were the most common symptoms (68.3%, 56.7%, and 53.3%, resp.). Arrhythmia and left ventricular ejection fraction (LVEF) < 60%, vomiting, weakness, and seizure were more common in the ECMO group than in the non-ECMO group, with statistical significance (). Female sex, vomiting, weakness, seizure, arrhythmia, and echocardiography showing LVEF < 60% may predict the need for ECMO. Initial serum troponin-I cutoff values greater than 14.21 ng/mL may also indicate the need for ECMO support for children with acute myocarditis.- 11 May 2017
- Published by Wiley in BioMed Research International
- Vol. 2017, 1-8
Open AccessPredictors of Extracorporeal Membrane Oxygenation Support for Children with Acute Myocarditis
The clinical presentation of acute myocarditis in children may range from asymptomatic to sudden cardiac arrest. This study analyzed the clinical spectrum of acute myocarditis in children to identify factors that could aid primary care physicians to predict the need for extracorporeal membrane oxygenation (ECMO) earlier and consult the pediatric cardiologist promptly. Between October 2011 and September 2016, we retrospectively analyzed 60 patients aged 18 years or younger who were admitted to our pediatric emergency department with a definite diagnosis of acute myocarditis. Data on demographics, presentation, laboratory tests, electrocardiogram and echocardiography findings, treatment modalities, complications, and long-term outcomes were obtained. During the study period, 60 patients (32 male, 28 female; mean age, years) were diagnosed with acute myocarditis. Fever, cough, and chest pain were the most common symptoms (68.3%, 56.7%, and 53.3%, resp.). Arrhythmia and left ventricular ejection fraction (LVEF) < 60%, vomiting, weakness, and seizure were more common in the ECMO group than in the non-ECMO group, with statistical significance (). Female sex, vomiting, weakness, seizure, arrhythmia, and echocardiography showing LVEF < 60% may predict the need for ECMO. Initial serum troponin-I cutoff values greater than 14.21 ng/mL may also indicate the need for ECMO support for children with acute myocarditis. - 25 May 2012
- Published by S. Karger AG in Neuropsychobiology
- Vol. 65 (4) , 216-226
Influence of Antipsychotic Agents on Heart Rate Variability in Male WKY Rats: Implications for Cardiovascular Safety
Background: Sudden cardiac death is higher among schizophrenic patients and is associated with parasympathetic hypoactivity. Antipsychotic agents are highly suspected to be a precipitating factor. Thus, we aimed to test if the antipsychotics haloperidol, risperidone and clozapine affect cardiac autonomic function, excluding the confounding effect of altered sleep structure by the drugs. Methods: In this study, haloperidol, risperidone and clozapine were given separately by intraperitoneal injection to male Wistar-Kyoto rats for 5 days. Electroencephalogram (EEG), electromyogram (EMG) and electrocardiographic signals were recorded at baseline and 5 days after drug treatments. Sleep scoring was based on EEG and EMG signals. Cardiac autonomic function was assessed using heart rate variability analysis. Results: Clozapine increased heart rate and suppressed cardiac sympathetic and parasympathetic activity. Cardiac acceleration was more severe during sleep. Haloperidol tended to decrease heart rate while risperidone mildly increased heart rate; however, their effects were less obvious than those of clozapine. There was a significant drug-by-stage interaction on several heart rate variability measures. Conclusion: Taking this evidence as a whole, we conclude that haloperidol has a better level of cardiovascular safety than either risperidone or clozapine. Application of this approach to other psychotropic agents in the future will be a useful and helpful way to evaluate the cardiovascular safety of the various psychotropic medications that are in clinical use.
- 25 May 2012
- Published by S. Karger AG in Neuropsychobiology
- Vol. 65 (4) , 216-226
Influence of Antipsychotic Agents on Heart Rate Variability in Male WKY Rats: Implications for Cardiovascular Safety
Background: Sudden cardiac death is higher among schizophrenic patients and is associated with parasympathetic hypoactivity. Antipsychotic agents are highly suspected to be a precipitating factor. Thus, we aimed to test if the antipsychotics haloperidol, risperidone and clozapine affect cardiac autonomic function, excluding the confounding effect of altered sleep structure by the drugs. Methods: In this study, haloperidol, risperidone and clozapine were given separately by intraperitoneal injection to male Wistar-Kyoto rats for 5 days. Electroencephalogram (EEG), electromyogram (EMG) and electrocardiographic signals were recorded at baseline and 5 days after drug treatments. Sleep scoring was based on EEG and EMG signals. Cardiac autonomic function was assessed using heart rate variability analysis. Results: Clozapine increased heart rate and suppressed cardiac sympathetic and parasympathetic activity. Cardiac acceleration was more severe during sleep. Haloperidol tended to decrease heart rate while risperidone mildly increased heart rate; however, their effects were less obvious than those of clozapine. There was a significant drug-by-stage interaction on several heart rate variability measures. Conclusion: Taking this evidence as a whole, we conclude that haloperidol has a better level of cardiovascular safety than either risperidone or clozapine. Application of this approach to other psychotropic agents in the future will be a useful and helpful way to evaluate the cardiovascular safety of the various psychotropic medications that are in clinical use.
- 4 May 2010
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 43 (20) , 205101
The influences of device geometry and p-type doping on a solution-processed polymer space-charge-limited transistor
A polymer vertical transistor with an on/off current ratio higher than 104 is demonstrated. The proposed space-charge limited transistor (SCLT) uses a metal-grid base containing high-density submicrometre openings to modulate the vertical space-charge-limited current (SCLC). The key to obtaining a high on/off current ratio is to reduce the leakage current of SCLT. In this paper, an improved device structure that isolates the grid metal by using both top and bottom insulating layers is demonstrated. Then, with an identical proposed structure, the geometric design is also found to significantly influence the on/off ratio over 3 orders of magnitude. The competition between the SCLC and the grid to collector leakage current is analysed. Finally, the influence of tetrafluoro-tetracyano-quinodimethane doping on the transistor characteristics is investigated. The results are important for the design of polymer vertical transistors with high on/off ratios.
- 4 May 2010
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 43 (20) , 205101
The influences of device geometry and p-type doping on a solution-processed polymer space-charge-limited transistor
A polymer vertical transistor with an on/off current ratio higher than 104 is demonstrated. The proposed space-charge limited transistor (SCLT) uses a metal-grid base containing high-density submicrometre openings to modulate the vertical space-charge-limited current (SCLC). The key to obtaining a high on/off current ratio is to reduce the leakage current of SCLT. In this paper, an improved device structure that isolates the grid metal by using both top and bottom insulating layers is demonstrated. Then, with an identical proposed structure, the geometric design is also found to significantly influence the on/off ratio over 3 orders of magnitude. The competition between the SCLC and the grid to collector leakage current is analysed. Finally, the influence of tetrafluoro-tetracyano-quinodimethane doping on the transistor characteristics is investigated. The results are important for the design of polymer vertical transistors with high on/off ratios.
- 1 December 2008
- Published by AIP Publishing in Applied Physics Letters
- Vol. 93 (22) , 223301
Light-emitting polymer space-charge-limited transistor
Polymer light-emitting transistor is realized by vertically stacking a top-emitting polymer light-emitting diode on a polymer space-charge-limited transistor. The transistor modulates the current flow of the light-emitting diode by the metal-grid base voltage. The active semiconductor of the transistor is poly(3-hexylthiophene). Yellow poly(para-phenylene vinylene) derivative is used as the yellow emitting material. As the cathode is fixed at −12 V and the grid base voltage varies from 0.9 to −0.9 V the light emission is turned on and off with on luminance up to 1208 cd/m2. The current efficiency of the light-emitting transistor is 10 cd/A.
- 1 December 2008
- Published by AIP Publishing in Applied Physics Letters
- Vol. 93 (22) , 223301
Light-emitting polymer space-charge-limited transistor
Polymer light-emitting transistor is realized by vertically stacking a top-emitting polymer light-emitting diode on a polymer space-charge-limited transistor. The transistor modulates the current flow of the light-emitting diode by the metal-grid base voltage. The active semiconductor of the transistor is poly(3-hexylthiophene). Yellow poly(para-phenylene vinylene) derivative is used as the yellow emitting material. As the cathode is fixed at −12 V and the grid base voltage varies from 0.9 to −0.9 V the light emission is turned on and off with on luminance up to 1208 cd/m2. The current efficiency of the light-emitting transistor is 10 cd/A.