  • Ten-year insert wear and the migration of uncemented tibial and femoral components with either conventional polyethylene or sequentially annealed highly crosslinked polyethylene: a blinded randomized controlled trial using radiostereometric analysis

    by Ruud de Ridder, Bart L. Kaptein, Bart G. Pijls, Rob G. H. H. Nelissen, Jantsje H. Pasma, Rianne Oomen, Herman H. Kaptijn

    Aims: The aims of this randomized controlled trial (RCT) was to compare the long-term insert wear and migration of the tibial and femoral components between highly crosslinked polyethylene (HXLPE) inserts and conventional polyethylene (PE) inserts in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Methods: A double-blinded RCT was conducted including 96 TKAs. The wear of the insert, and migration of both the tibial and femoral components, was measured with model-based radiostereometric analysis up to ten years postoperatively. Patient-reported outcome measures (PROMs) were collected preoperatively and at follow-up. Results: There was no progression of (medial) wear (from 0.15 mm at five years to 0.13 mm at ten years) for the HXLPE group after five years, whereas the wear rate increased for the PE group (from 0.22 mm at five years to 0.46 mm at ten years). There was no clinically relevant difference in terms of migration of the tibial and femoral component or PROMs between the HXLPE and PE groups at ten years. Migration of the tibial component (maximal total point motion; MTPM) after the ten-year follow-up for the HXLPE group was 0.99 mm (95% CI 0.83 to 1.18), and for the PE group, was 1.05 mm (95% CI 0.87 to 1.24). Migration of the femoral component (MTPM) after the ten-year follow-up for the HXLPE group was 1.16 mm (95% CI 0.99 to 1.35), and for the PE group, MTPM was 1.04 mm (95% CI 0.87 to 1.22). Conclusion: There was no discernible increased wear for the HXLPE group after five years, whereas the wear for the PE group continued. After the initial migration, the uncemented TKA components remain stable at the ten-year follow-up. The use of HXLPE inserts are safe, when used in uncemented TKA, when considering wear and component migration. Cite this article: Bone Joint J 2026;108-B(10):1247–1254.

  • Open Access

    Similar 2 year migration patterns for a shortened and a distally reduced stem design in uncemented total hip arthroplasty: a randomized controlled trial using radiostereometric analysis

    by Lennard Koster, Bart L Kaptein, Esmeralda Goorden, Constant A M P Bell, Rob G H H Nelissen

    Background and purpose: The primary objective was to compare subsidence and retroversion in the first 2 postoperative years of 2 uncemented hip stem designs in primary minimally invasive anterior-supine surgical (MIS-ASI) total hip arthroplasty: a shortened hip stem (Microplasty) and a standard-length stem with reduced distal width (Reduced Distal). Secondary objectives were to compare migration patterns, patient-reported outcome measures (PROMs), clinical and radiological scores, and the occurrence of (serious) adverse events up to 2 years postoperatively.Methods: 50 patients were randomized in this non-blinded, single-surgeon, industry-funded, radiostereometric analysis study (RSA) (ClinicalTrials.gov NCT03409666). Stem migration was measured relative to directly postoperative at 6 weeks, 1 year, and 2 years postoperatively, using model-based RSA. Linear mixed-effect modelling was used to compare migration. Primary outcomes were subsidence and retroversion at 2 years postoperatively. Secondary outcomes were migration, PROM questionnaires, clinical and radiological scores, and the presence of adverse events in the first 2 postoperative years.Results: Migration of 15 Microplasty and 20 Reduced Distal stems showed comparable initial migration between direct and 6 weeks postoperative RSA, stabilizing thereafter. Predominant migration directions were subsidence and retroversion with mean values at 2 years of 1.47 mm (95% confidence interval [CI] 0.32–2.61) and 2.57° (CI 1.64–3.50) for the Microplasty stem and 2.35 mm (CI 1.36–3.34) and 1.59° (CI 0.79–2.39) for the Reduced Distal stem. At 6 weeks postoperatively, posterior tilt about the medial–lateral axis was different between stem designs, with 0.07° (CI –0.27 to 0.40) for the Microplasty and 0.48° (CI 0.19–0.77) for the Reduced Distal designs. Secondary outcomes were not clinically different between the stem designs.Conclusion: We showed that initial subsidence and retroversion for both stem designs in MIS-ASI surgery was present, although likely not clinically relevant. There was no statistically significant difference in subsidence and retroversion between the stem designs. Although initial migration varied substantially between patients and the Reduced Distal design showed more posterior tilting, both designs maintained a stable position from 6 weeks to 2 years postoperatively.

  • The association between tibial slope and posterior tibial tilting, not wear, in uncemented total knee arthroplasty

    by Ruud de Ridder, Bart L. Kaptein, Bart G. Pijls, Rob G. H. H. Nelissen, Herman H. Kaptijn

    Aims: The primary objective of this study was to evaluate the influence of postoperative slope on the five-year tibial component migration and wear following uncemented cruciate-retaining condylar-stabilized total knee arthroplasty (TKA). Secondary objectives included the association between postoperative slope and clinical and functional outcomes. Methods: This observational study was a secondary analysis of a randomized controlled trial of 93 TKAs on insert materials. Tibial component migration and insert wear were measured across three postoperative slope groups (small (≤ 5°), intermediate (6° to 9°), and large (≥ 10°)) using radiostereometric analysis at three, six, 12, 24, and 60 months postoperatively. Patient-reported outcome measures were collected preoperatively and at all follow-up timepoints. Results: There was an association between tibial component migration and postoperative tibial slope: the group with the largest postoperative tibial slope showed the largest posterior tilting. At five years, there was no difference in insert wear between the small, intermediate, and large slope groups. There was also no association between postoperative slope and functional or patient-reported outcomes. Conclusion: TKA implanted with more than 10° of slope showed increased tibial component migration and posterior tilting, independent of the native slope. At five years, there was no influence of slope on wear or functional outcomes. Cite this article: Bone Joint J 2026;108-B(5):634–642.

  • Open Access

    Migration patterns of uncemented femoral stems in hip replacement: a systematic review and meta-analysis of clinical radiostereometric analysis cohort studies

    by Lisa Van der Water, Christiaan H Righolt, Trevor Gascoyne, Bart L Kaptein, Rob G H H Nelissen, Bart G C W Pijls

    Background and purpose: We conducted a systematic review and meta-analysis of radiostereometric analysis studies of primary uncemented femoral stems to investigate their subsidence and retroversion patterns and the migration patterns according to implant, patient, and study characteristics.Methods: A systematic search of PubMed, Web of Science, Cochrane, and Embase databases to identify all radiostereometric analysis studies on femoral stem migration following primary uncemented total hip replacement was performed. Clinical studies with 2 or more postoperative radiostereometric measurements within 2 years were included. Subsidence and retroversion at 6 weeks, 3 and 6 months, 1, 2, 5, and 10 years were included for analysis. Extracted implant characteristics included implant design, coating, and surgical approach. Data was analyzed using a random effects model.Results: 73 studies on 120 cohorts and 2,970 uncemented stems were included. 119 cohorts reported on subsidence and 91 on retroversion. The pooled subsidence at 3 months was 0.29 mm (95% confidence interval [CI] 0.19–0.39) and 0.32 mm (CI 0.21–0.43) at 2 years. The pooled retroversion at 3 months was 0.51° (CI 0.33–0.70) and 0.70° (CI 0.48–0.93) at 2 years. Hydroxyapatite-coated stems showed the least migration (subsidence 0.26 mm; CI 0.13–0.40; retroversion 0.51°; CI 0.22–0.80) among different coating types. The anterior approach showed more migration (subsidence 1.04 mm, CI 0.53–1.55; retroversion 1.52°, CI 1.08–1.95) than other surgical approaches.Conclusion: Our study shows that most subsidence and retroversion of uncemented femoral stems occurs during the first 3 months. Stabilization of subsidence occurred after 3 months, and retroversion stabilized after 2 years. Migration patterns differ based on stem type, coating, surgical approach, the time period when inclusion started, and timing of baseline measurement.


  • Open Access

    The long-term revision risk of RSA-tested and non-RSA-tested TKA implants in The Netherlands: a Dutch arthroplasty register study

    by Thies J N Van der Lelij, Bart G Pijls, Bart L Kaptein, Liza N Van Steenbergen, Rob G H H Nelissen, Perla J Marang-Van de Mheen

    Background and purpose: Radiostereometric analysis (RSA) of total knee arthroplasty (TKA) is used as an early safeguard during the phased evidence-based introduction of new implants. The goal of our study was to compare the long-term revision risk between RSA-tested implants and non-RSA-tested implants in the Netherlands using patient-level data.Methods: All primary TKAs between 2007 and 2016 from the Dutch Arthroplasty Register were included, and procedures with an RSA-tested implant were identified. Both all-cause major revision risk and revision risk because of loosening were calculated at 5 and 10 years postoperatively using Kaplan–Meier analyses. Sensitivity analyses were performed with stricter definitions of implant characteristics to classify procedures as RSA-tested, to avoid camouflage of different subdesigns within the same brand implant portfolio.Results: 83,638 RSA-tested and 104,105 non-RSA-tested TKAs were included. Cumulative all-cause major revision percentages for the RSA-tested group at 5 and 10 years were 2.2% (95% confidence interval [CI] 2.1–2.3) and 3.6% (CI 3.4–3.7), respectively, compared with 2.5% (CI 2.4–2.6) and 3.3% (CI 3.2–3.4) for the non-RSA-tested group. RSA-tested TKAs showed higher 10-year revision risks because of loosening than non-RSA-tested procedures (1.8%, CI 1.7–1.9 vs 1.4%, CI 1.3–1.4, respectively). Comparable results were found after stratification by various patient characteristics and with stricter classification approaches.Conclusion: Regarding all-cause revision risk, RSA-tested TKAs had a slightly lower risk at 5 years. However, at 10 years the RSA-tested TKAs had a higher all-cause revision risk and higher revision risk because of loosening compared with the non-RSA-tested TKAs.

  • Open Access

    Precision evaluation of 2 CT-based radiostereometric analysis systems in a cadaver study

    by Maaike R De Bondt, Frank-David Øhrn, Lars H W Engseth, Anselm Schulz, Bart L Kaptein, Stephan M Röhrl, Petra J C Heesterbeek

    Background and purpose: To address the limitations of radiostereometric imaging and to eliminate the need for intraoperative marker placement, CT-based radiostereometric analysis (CT-RSA) software systems have been developed. We aimed to evaluate the precision of a novel CT-RSA software system, V3MA, against an established CT-RSA software system, CTMA, while also examining the impact of CT scanner model on precision.Methods: 7 CT scans per scanner (Siemens SOMATOM Force and GE Revolution) of a porcine cadaver with a knee implant were used for pairwise comparisons. By aligning paired CT scans, the translation (mm), rotation (°), and maximum total point motion (MTPM, mm) of the tibial implant with respect to the bone were computed. V3MA aligned the scans using the voxel gray values of the bone and implant, whereas CTMA aligned the surface points of the bone and implant. The precision of both software systems and the effect of both scanner models were investigated using paired data in a linear mixed model.Results: Both software systems resulted in a similar MTPM (contrast V3MA–CTMA –0.002 mm, 95% confidence interval [CI] –0.015 to 0.011; V3MA: 0.09 mm; CTMA: 0.10 mm), indicating comparable precision using a minimal important difference of 0.10 mm. Using Siemens scanner data resulted in a higher estimated MTPM than using GE scanner data (contrast Siemens–GE 0.046 mm, CI 0.024–0.067; Siemens: 0.12 mm; GE: 0.072 mm).Conclusion: The precision of the new CT-RSA software system, V3MA, is comparable to that of CTMA under zero-motion assumptions. Minor, clinically irrelevant, inter-scanner differences in CT-RSA precision exist for both software systems.


  • Open Access

    Extra-axial chordoma of the distal femur: a clinical and radiological challenge—case report and literature review -

    by Lotje A. Hoogervorst, Thomas W. Borsje, Danique L. M. van Broekhoven, Bart Kaptein, Ana Navas Cañete, Shaho Hasan, Robert J. P. van der Wal

    We report a very rare case of an intraossesous extra-axial chordoma (EAC) involving the distal femur. We describe the clinical presentation, radiologic and pathological findings, and the treatment. In addition, a systematic literature search was performed to further expand the knowledge regarding EAC in the lower extremities, including 13 papers describing a total of 21 adult patients.


  • Open Access

    Clinical Validation and Excellent Interobserver Agreement of Volumetric Matching Micromotion Analysis (V3MA) in Total Knee Arthroplasty

    by Nienke N. de Laat, Lennard A. Koster, Jessie E. Robertson, Rob G.H.H. Nelissen, Bart L. Kaptein

    CT‐based radiostereometric analysis (CT‐RSA) is an alternative to RSA to measure implant migration. We performed a clinical validation study using VoluMetric Matching Micromotion Analysis (V3MA) software for CT‐RSA. The aims of this study were to assess the agreement between V3MA and Model‐based RSA software (for RSA), and to determine the interobserver agreement in V3MA. On a subset of patients included in a clinical trial, knee prosthesis tibial implant migration was measured between 1 and 5 years postoperative with V3MA and Model‐based RSA software. V3MA and Model‐based RSA results were compared by assessing the mean differences and limits of agreement (mean ± 1.96* standard deviation) using Bland–Altman analysis. V3MA migration results of two observers were compared using intraclass correlation (ICC) and Bland–Altman analysis. Twenty‐four patients were included in the analysis. The mean difference (limits of agreement [LOA]) was −0.14 mm [−0.88 to 0.60] for maximum total point motion (MTPM). LOA for translations and rotations did not exceed ±0.5 mm and ±1°, respectively. The ICC (95% confidence interval) for MTPM between observers was 0.995 (0.989–0.998), and the mean difference [LOA] was 0.04 mm [−0.17 to 0.24]. We showed that between 1 and 5 years postoperative, V3MA migration results were comparable to those of Model‐based RSA for cemented tibial component migration in a clinical study. The interobserver variability showed excellent agreement for V3MA. Overall, V3MA is a valid alternative to Model‐based RSA for the analysis of tibial component migration in TKA with medium‐term follow‐up.


  • Open Access

    Additively manufactured shape-morphing implants for the treatment of acetabular defects

    by Vahid Moosabeiki, Marius A. Leeflang, Jasper G. Gerbers, Pier H. de Jong, Demien Broekhuis, Yash Agarwal, Jagathes N. Ganesen, Bart L. Kaptein, Rob G.H.H. Nelissen, Mohammad J. Mirzaali, et al.