Xueming Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xueming Dong has a total of 115 co-authors. Here are the top co-authors by number of shared publications:
Feng-Yun Ma
6 shared publicationsShuangshuang Zhu
Nanyang Technological University
5 shared publications- Xing Fan
Shandong University of Science and Technology
5 shared publications Ying Deng
Nanyang Technological University
5 shared publicationsXian-Yong Wei
4 shared publications- Xian-Yong Wei
School of Chemical Engineering & Technology, China University of Mining and Technology, Xuzhou, 221116, Jiangsu, China
4 shared publications
Latest Publications
- 19 November 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
Gravity-Driven, Acoustic-Field-Guided Droplet Addition for 12 h Container-Free Proteomic Processing
With advances in analytical sensitivity, low-input samples increasingly require sample-preparation workflows that limit analyte loss during multistep processing. Acoustic levitation (AL) provides a container-free aqueous reaction format. Here, we implemented gravity-driven, acoustic-field-guided droplet addition in a TinyLev-type device, in which reagent droplets dispensed at lateral distances of up to 3 mm merged with a levitated droplet without needle contact. Periodic water replenishment supported 12 h levitation at 37 °C, with 93% Angiotensin II (Ang II) signal retention compared to 53% in low-protein-binding tube. This operational window enabled an approximately 10 h multistep proteomic sample-processing workflow involving 8 h trypsin digestion. Contactless handling produced no detectable residual Ang II peaks in post-exposure blanks, whereas direct needle contact resulted in carryover. Acoustic levitation also provided higher Ang II signal retention than low-protein-binding tube incubation. In proteomic benchmarking, AL yielded higher protein identification counts at 50 and 100 ng, accompanied by higher normalized LFQ variability, particularly at 100 ng. AL also showed higher mean fractions of fully cleaved PSMs and lower mean semi-tryptic PSM fractions at both inputs. A complementary HRP-TMB assay showed a higher concentration−response slope after AL than after conventional microplate incubation. Together, these findings support the use of acoustic levitation as a practical platform for contactless reagent addition and long-duration container-free biochemical processing.
- 19 November 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
Gravity-Driven, Acoustic-Field-Guided Droplet Addition for 12 h Container-Free Proteomic Processing
With advances in analytical sensitivity, low-input samples increasingly require sample-preparation workflows that limit analyte loss during multistep processing. Acoustic levitation (AL) provides a container-free aqueous reaction format. Here, we implemented gravity-driven, acoustic-field-guided droplet addition in a TinyLev-type device, in which reagent droplets dispensed at lateral distances of up to 3 mm merged with a levitated droplet without needle contact. Periodic water replenishment supported 12 h levitation at 37 °C, with 93% Angiotensin II (Ang II) signal retention compared to 53% in low-protein-binding tube. This operational window enabled an approximately 10 h multistep proteomic sample-processing workflow involving 8 h trypsin digestion. Contactless handling produced no detectable residual Ang II peaks in post-exposure blanks, whereas direct needle contact resulted in carryover. Acoustic levitation also provided higher Ang II signal retention than low-protein-binding tube incubation. In proteomic benchmarking, AL yielded higher protein identification counts at 50 and 100 ng, accompanied by higher normalized LFQ variability, particularly at 100 ng. AL also showed higher mean fractions of fully cleaved PSMs and lower mean semi-tryptic PSM fractions at both inputs. A complementary HRP-TMB assay showed a higher concentration−response slope after AL than after conventional microplate incubation. Together, these findings support the use of acoustic levitation as a practical platform for contactless reagent addition and long-duration container-free biochemical processing.
- 8 October 2026
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- p. 1-15
Evaluation and correction of charcoal-stripped serum matrix bias in stable-isotope-dilution LC–MS/MS quantification of endogenous serum folates
Isotope-dilution LC–MS/MS is widely used for targeted quantification of endogenous metabolites, but surrogate-matrix calibration can remain biased when the surrogate matrix is noncommutable with native specimens. In this study, three endogenous serum folate vitamers were quantified by stable-isotope-dilution LC–MS/MS using charcoal-stripped serum (CSS) as a surrogate blank matrix. Post-extraction spiking and pooled-serum standard addition showed analyte-dependent and batch-dependent matrix bias between CSS and native serum. Standard addition comparison revealed matrix factors of 1.005 to 1.611 for 5-methyltetrahydrofolate (5-mTHF), 0.607 to 1.000 for folic acid (FA), and 0.902 to 1.008 for folinic acid, indicating a higher analyte-to-internal-standard normalized response in native serum relative to CSS for 5-mTHF, a lower normalized response for FA, and minimal matrix-dependent response difference for folinic acid. To address this bias, we developed a pooled-serum, batch-specific matrix-factor correction workflow based on standard addition. This approach estimates matrix factors in pooled native serum and applies them to CSS-calibrated concentrations generated under the same batch conditions, avoiding the sample-volume burden of conventional standard addition. Matrix-factor correction reduced validation bias for 5-mTHF and FA to within the predefined ± 15% criterion. In 64 clinical serum samples, correction changed classification relative to selected total folate reference decision limits (5–21 ng/mL) in ten samples (15.6%) for 5-mTHF and five samples (7.8%) for FA. These findings show that CSS-based stable-isotope-dilution LC–MS/MS can produce residual matrix-dependent bias despite normalization using stable-isotope-labeled internal standards (SIL-IS), and that pooled-serum standard addition provides a practical correction strategy. Graphical abstract
- 8 October 2026
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- p. 1-15
Evaluation and correction of charcoal-stripped serum matrix bias in stable-isotope-dilution LC–MS/MS quantification of endogenous serum folates
Isotope-dilution LC–MS/MS is widely used for targeted quantification of endogenous metabolites, but surrogate-matrix calibration can remain biased when the surrogate matrix is noncommutable with native specimens. In this study, three endogenous serum folate vitamers were quantified by stable-isotope-dilution LC–MS/MS using charcoal-stripped serum (CSS) as a surrogate blank matrix. Post-extraction spiking and pooled-serum standard addition showed analyte-dependent and batch-dependent matrix bias between CSS and native serum. Standard addition comparison revealed matrix factors of 1.005 to 1.611 for 5-methyltetrahydrofolate (5-mTHF), 0.607 to 1.000 for folic acid (FA), and 0.902 to 1.008 for folinic acid, indicating a higher analyte-to-internal-standard normalized response in native serum relative to CSS for 5-mTHF, a lower normalized response for FA, and minimal matrix-dependent response difference for folinic acid. To address this bias, we developed a pooled-serum, batch-specific matrix-factor correction workflow based on standard addition. This approach estimates matrix factors in pooled native serum and applies them to CSS-calibrated concentrations generated under the same batch conditions, avoiding the sample-volume burden of conventional standard addition. Matrix-factor correction reduced validation bias for 5-mTHF and FA to within the predefined ± 15% criterion. In 64 clinical serum samples, correction changed classification relative to selected total folate reference decision limits (5–21 ng/mL) in ten samples (15.6%) for 5-mTHF and five samples (7.8%) for FA. These findings show that CSS-based stable-isotope-dilution LC–MS/MS can produce residual matrix-dependent bias despite normalization using stable-isotope-labeled internal standards (SIL-IS), and that pooled-serum standard addition provides a practical correction strategy. Graphical abstract
- Open Access
- 29 September 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Acoustic-assisted HDX-MS for Intact Virion Analysis
Hydrogen-deuterium exchange mass spectrometry (HDX-MS) enables solution-phase characterization of protein interactions and conformational dynamics, but analysis of intact enveloped virions remains challenging because limited proteolytic accessibility restricts peptide recovery. Here, we developed an acoustic-assisted HDX-MS workflow integrating chemical denaturation with bath sonication during quenching and applied it to dengue virus serotype 2 (DENV2) strain D2Y98P. The workflow achieved sequence coverages of 96.0 ± 0.7%, 89.8 ± 0.8% and 87.1 ± 1.0% for the capsid (C), envelope (E) and membrane (M) proteins, respectively. Model peptide measurements showed comparable back-exchange between sonication and incubation at matched durations, although longer treatment increased deuterium loss. Improved E protein coverage enabled characterization of changes in deuterium uptake associated with binding of the neutralizing antibody 2D22. Protected regions overlapped spatially with the cryo-EM-defined quaternary interface, while additional protection occurred in regions remote from direct antibody contact. These findings are consistent with antibody-associated conformational stabilization extending beyond the binding interface. Acoustic-assisted HDX-MS therefore improves structural protein coverage and complements cryo-EM by revealing peptide-level changes in antibodyassociated protein dynamics in the intact virion context.
- 29 September 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessAcoustic-assisted HDX-MS for Intact Virion Analysis
Hydrogen-deuterium exchange mass spectrometry (HDX-MS) enables solution-phase characterization of protein interactions and conformational dynamics, but analysis of intact enveloped virions remains challenging because limited proteolytic accessibility restricts peptide recovery. Here, we developed an acoustic-assisted HDX-MS workflow integrating chemical denaturation with bath sonication during quenching and applied it to dengue virus serotype 2 (DENV2) strain D2Y98P. The workflow achieved sequence coverages of 96.0 ± 0.7%, 89.8 ± 0.8% and 87.1 ± 1.0% for the capsid (C), envelope (E) and membrane (M) proteins, respectively. Model peptide measurements showed comparable back-exchange between sonication and incubation at matched durations, although longer treatment increased deuterium loss. Improved E protein coverage enabled characterization of changes in deuterium uptake associated with binding of the neutralizing antibody 2D22. Protected regions overlapped spatially with the cryo-EM-defined quaternary interface, while additional protection occurred in regions remote from direct antibody contact. These findings are consistent with antibody-associated conformational stabilization extending beyond the binding interface. Acoustic-assisted HDX-MS therefore improves structural protein coverage and complements cryo-EM by revealing peptide-level changes in antibodyassociated protein dynamics in the intact virion context.
- Open Access
Ion-Pair-Free Capillary HILIC-MS for Sensitive Nucleic Acid Analysis and RNA Modification Mapping
Mass spectrometry (MS)-based nucleic acid analysis provides direct chemical evidence for oligonucleotide sequence, composition, and modifications. However, oligonucleotide LC-MS analysis commonly relies on ion-pairing reversed-phase liquid chromatography (IP-RPLC). Although IP-RPLC provides strong retention and high-resolution separation of highly charged nucleic acids, ion-pairing reagents can contaminate LC-MS systems, suppress electrospray ionization, require extensive system cleaning, and limit the use of high-end MS platforms that are primarily dedicated to proteomics or metabolomics. Here, we developed and evaluated an ion-pair-free capillary hydrophilic interaction liquid chromatography mass spectrometry (capillary HILIC-MS) workflow for RNA modification mapping. To enable robust analysis of biologically relevant samples, we optimized sample preparation, high-organic loading conditions, chromatographic parameters, and MS source settings to overcome key challenges associated with capillary HILIC, including limited sample volume, solvent compatibility, and solvent breakthrough during injection. The optimized capillary HILIC-MS method provided effective separation of oligonucleotides below 30 nt and enabled sensitive detection of RNA modifications in the populations of tRNAs and rRNAs in biological samples. Importantly, the ion-pair-free workflow also allowed switching between nucleic acid analysis and proteomics on the same LC-MS platform without the need for extensive system decontamination. Together, this workflow provides a sensitive, robust, and MS-compatible approach for nucleic acid analysis, expanding the utility of high-end LC-MS systems for both therapeutic oligonucleotide characterization and biological RNA modification profiling.
Open AccessIon-Pair-Free Capillary HILIC-MS for Sensitive Nucleic Acid Analysis and RNA Modification Mapping
Mass spectrometry (MS)-based nucleic acid analysis provides direct chemical evidence for oligonucleotide sequence, composition, and modifications. However, oligonucleotide LC-MS analysis commonly relies on ion-pairing reversed-phase liquid chromatography (IP-RPLC). Although IP-RPLC provides strong retention and high-resolution separation of highly charged nucleic acids, ion-pairing reagents can contaminate LC-MS systems, suppress electrospray ionization, require extensive system cleaning, and limit the use of high-end MS platforms that are primarily dedicated to proteomics or metabolomics. Here, we developed and evaluated an ion-pair-free capillary hydrophilic interaction liquid chromatography mass spectrometry (capillary HILIC-MS) workflow for RNA modification mapping. To enable robust analysis of biologically relevant samples, we optimized sample preparation, high-organic loading conditions, chromatographic parameters, and MS source settings to overcome key challenges associated with capillary HILIC, including limited sample volume, solvent compatibility, and solvent breakthrough during injection. The optimized capillary HILIC-MS method provided effective separation of oligonucleotides below 30 nt and enabled sensitive detection of RNA modifications in the populations of tRNAs and rRNAs in biological samples. Importantly, the ion-pair-free workflow also allowed switching between nucleic acid analysis and proteomics on the same LC-MS platform without the need for extensive system decontamination. Together, this workflow provides a sensitive, robust, and MS-compatible approach for nucleic acid analysis, expanding the utility of high-end LC-MS systems for both therapeutic oligonucleotide characterization and biological RNA modification profiling.
- Open Access
- 6 July 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Acoustic-Pressure-Guided Coalescence Enables Contactless Reagent Addition and 12-Hour Acoustic Levitation for Container-Free Proteomics
With advances in analytical sensitivity, low-input samples increasingly require sample-preparation workflows that limit analyte loss during multistep processing. Acoustic levitation (AL) provides a container-free aqueous reaction format, but its broader use has been limited by the lack of simple contactless reagent addition and insufficient long-duration droplet stability. Here, we developed an acoustic levitation platform based on acoustic-pressure-guided coalescence (APGC), in which reagent droplets dispensed several millimeters from the target are guided into a levitated droplet without needle contact. The concave-field configuration provided lateral confinement compatible with maintenance of 10 µL aqueous droplets for 12 h. This operational window enabled an approximately 10 h multistep proteomic sample-processing workflow. APGC-mediated addition did not produce a statistically detectable increase in Ang II carryover signal above the blank control, whereas direct needle contact resulted in marked carryover. Acoustic levitation also provided improved Ang II signal retention relative to low-protein-binding tube incubation. In proteomic benchmarking, the container-free workflow yielded approximately 70% higher protein identification coverage and an 11.9% increase in fully cleaved peptide-spectrum matches. An orthogonal HRP-TMB assay further showed a higher apparent concentration-response slope after acoustic levitation than after conventional microplate incubation. Together, these findings establish APGC-enabled acoustic levitation as a practical platform for contactless reagent addition and long-duration container-free biochemical processing.
- 6 July 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessAcoustic-Pressure-Guided Coalescence Enables Contactless Reagent Addition and 12-Hour Acoustic Levitation for Container-Free Proteomics
With advances in analytical sensitivity, low-input samples increasingly require sample-preparation workflows that limit analyte loss during multistep processing. Acoustic levitation (AL) provides a container-free aqueous reaction format, but its broader use has been limited by the lack of simple contactless reagent addition and insufficient long-duration droplet stability. Here, we developed an acoustic levitation platform based on acoustic-pressure-guided coalescence (APGC), in which reagent droplets dispensed several millimeters from the target are guided into a levitated droplet without needle contact. The concave-field configuration provided lateral confinement compatible with maintenance of 10 µL aqueous droplets for 12 h. This operational window enabled an approximately 10 h multistep proteomic sample-processing workflow. APGC-mediated addition did not produce a statistically detectable increase in Ang II carryover signal above the blank control, whereas direct needle contact resulted in marked carryover. Acoustic levitation also provided improved Ang II signal retention relative to low-protein-binding tube incubation. In proteomic benchmarking, the container-free workflow yielded approximately 70% higher protein identification coverage and an 11.9% increase in fully cleaved peptide-spectrum matches. An orthogonal HRP-TMB assay further showed a higher apparent concentration-response slope after acoustic levitation than after conventional microplate incubation. Together, these findings establish APGC-enabled acoustic levitation as a practical platform for contactless reagent addition and long-duration container-free biochemical processing.
- Open Access
- 18 June 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Standard addition-guided correction of charcoal-stripped serum noncommutability in 13C isotope-dilution LC-MS/MS quantification of endogenous serum folates
Charcoal-stripped serum (CSS) is widely used as a surrogate blank matrix for LC-MS/MS quantification of endogenous serum analytes when true analyte-free serum is unavailable. However, the commutability of CSS with native serum is often assumed rather than experimentally verified. In this study, endogenous serum folate vitamers were used as a clinically relevant model system to evaluate whether CSS-based calibration remains commutable with native serum under 13C isotope-dilution LC-MS/MS conditions and to develop a practical correction approach when noncommutability is present. A rapid LC-MS/MS assay was developed for 5methyltetrahydrofolate (5-mTHF), folic acid (FA), and folinic acid. The assay achieved LODs of 0.009 ng/mL for 5-mTHF and folinic acid and 0.0375 ng/mL for FA, with LOQs of 0.059 ng/mL for 5-mTHF and folinic acid and 0.117 ng/mL for FA, linearity from 0.059 to 60 ng/mL (R2 > 0.995), recoveries of 93% to 96%, and intra-day and inter-day imprecision below 15%. Post-extraction spiking and pooled-serum standard addition showed analyte-dependent and batch-dependent noncommutability between CSS and native serum. Standard-addition slope comparison revealed matrix factors of 1.005 to 1.611 for 5-mTHF, 0.607 to 1.000 for FA, and 0.902 to 1.008 for folinic acid, corresponding to ion enhancement for 5-mTHF, ion suppression for FA, and minimal matrix bias for folinic acid. A pooled-serum, batch-specific matrix-factor correction reduced validation bias for 5-mTHF and FA to within the commonly accepted ±15% criterion. When applied to 66 pediatric clinical serum samples, matrix-factor correction changed classification relative to selected reference decision limits in 10 of 35 patients for 5-mTHF and 5 of 35 patients for FA. Exploratory LC-MS/MS analysis further indicated the presence of co-eluting lipid-related compounds in native serum extracts, supporting residual matrix composition as a plausible contributor to the observed bias. These findings demonstrate that CSS-based calibration can produce clinically relevant matrix-dependent bias in endogenous LC-MS/MS assays despite 13C internal-standard correction. Pooled-serum standard addition provides a regulatory-compatible and sample-sparing approach to quantify and correct this bias without requiring standard addition in every clinical specimen.
- 18 June 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessStandard addition-guided correction of charcoal-stripped serum noncommutability in 13C isotope-dilution LC-MS/MS quantification of endogenous serum folates
Charcoal-stripped serum (CSS) is widely used as a surrogate blank matrix for LC-MS/MS quantification of endogenous serum analytes when true analyte-free serum is unavailable. However, the commutability of CSS with native serum is often assumed rather than experimentally verified. In this study, endogenous serum folate vitamers were used as a clinically relevant model system to evaluate whether CSS-based calibration remains commutable with native serum under 13C isotope-dilution LC-MS/MS conditions and to develop a practical correction approach when noncommutability is present. A rapid LC-MS/MS assay was developed for 5methyltetrahydrofolate (5-mTHF), folic acid (FA), and folinic acid. The assay achieved LODs of 0.009 ng/mL for 5-mTHF and folinic acid and 0.0375 ng/mL for FA, with LOQs of 0.059 ng/mL for 5-mTHF and folinic acid and 0.117 ng/mL for FA, linearity from 0.059 to 60 ng/mL (R2 > 0.995), recoveries of 93% to 96%, and intra-day and inter-day imprecision below 15%. Post-extraction spiking and pooled-serum standard addition showed analyte-dependent and batch-dependent noncommutability between CSS and native serum. Standard-addition slope comparison revealed matrix factors of 1.005 to 1.611 for 5-mTHF, 0.607 to 1.000 for FA, and 0.902 to 1.008 for folinic acid, corresponding to ion enhancement for 5-mTHF, ion suppression for FA, and minimal matrix bias for folinic acid. A pooled-serum, batch-specific matrix-factor correction reduced validation bias for 5-mTHF and FA to within the commonly accepted ±15% criterion. When applied to 66 pediatric clinical serum samples, matrix-factor correction changed classification relative to selected reference decision limits in 10 of 35 patients for 5-mTHF and 5 of 35 patients for FA. Exploratory LC-MS/MS analysis further indicated the presence of co-eluting lipid-related compounds in native serum extracts, supporting residual matrix composition as a plausible contributor to the observed bias. These findings demonstrate that CSS-based calibration can produce clinically relevant matrix-dependent bias in endogenous LC-MS/MS assays despite 13C internal-standard correction. Pooled-serum standard addition provides a regulatory-compatible and sample-sparing approach to quantify and correct this bias without requiring standard addition in every clinical specimen.
- 16 November 2022
- Published by Wiley in ChemSusChem
- Vol. 16 (1) , e202201441
Energy‐Resolved Mass Spectrometry as a Tool for Identification of Lignin Depolymerization Products
Lignin is the largest source of bio‐based aromatic compounds in nature, and its valorization is essential to the sustainability of lignocellulosic biorefining. Characterizing lignin‐derived compounds remains challenging due to the heterogeneity of this biopolymer. Tandem mass spectrometry is a promising tool for lignin structural analytics, as fragmentation patterns of model compounds can be extrapolated to identify characteristic moieties in complex samples. This work extended previous resonance excitation‐type collision‐induced dissociation (CID) methods that identified lignin oligomers containing β–O–4, β–5, and β–β bonds, to also identify characteristics of 5–5, β–1, and 4–O–5 dimers, enabled by quadrupole time‐of‐flight (QTOF) CID with energy‐resolved mass spectrometry (ERMS). Overall, QTOF‐ERMS offers in‐depth structural information and could ultimately contribute to tools for high‐throughput lignin dimer identification.
- 16 November 2022
- Published by Wiley in ChemSusChem
- Vol. 16 (1) , e202201441
Energy‐Resolved Mass Spectrometry as a Tool for Identification of Lignin Depolymerization Products
Lignin is the largest source of bio‐based aromatic compounds in nature, and its valorization is essential to the sustainability of lignocellulosic biorefining. Characterizing lignin‐derived compounds remains challenging due to the heterogeneity of this biopolymer. Tandem mass spectrometry is a promising tool for lignin structural analytics, as fragmentation patterns of model compounds can be extrapolated to identify characteristic moieties in complex samples. This work extended previous resonance excitation‐type collision‐induced dissociation (CID) methods that identified lignin oligomers containing β–O–4, β–5, and β–β bonds, to also identify characteristics of 5–5, β–1, and 4–O–5 dimers, enabled by quadrupole time‐of‐flight (QTOF) CID with energy‐resolved mass spectrometry (ERMS). Overall, QTOF‐ERMS offers in‐depth structural information and could ultimately contribute to tools for high‐throughput lignin dimer identification.
- Top Cited Papers
- 14 October 2022
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 378 (6616) , 207-211
Mixed plastics waste valorization through tandem chemical oxidation and biological funneling
Mixed plastics waste represents an abundant and largely untapped feedstock for the production of valuable products. The chemical diversity and complexity of these materials, however, present major barriers to realizing this opportunity. In this work, we show that metal-catalyzed autoxidation depolymerizes comingled polymers into a mixture of oxygenated small molecules that are advantaged substrates for biological conversion. We engineer a robust soil bacterium, Pseudomonas putida , to funnel these oxygenated compounds into a single exemplary chemical product, either β-ketoadipate or polyhydroxyalkanoates. This hybrid process establishes a strategy for the selective conversion of mixed plastics waste into useful chemical products.
- 14 October 2022
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 378 (6616) , 207-211
Top Cited PapersMixed plastics waste valorization through tandem chemical oxidation and biological funneling
Mixed plastics waste represents an abundant and largely untapped feedstock for the production of valuable products. The chemical diversity and complexity of these materials, however, present major barriers to realizing this opportunity. In this work, we show that metal-catalyzed autoxidation depolymerizes comingled polymers into a mixture of oxygenated small molecules that are advantaged substrates for biological conversion. We engineer a robust soil bacterium, Pseudomonas putida , to funnel these oxygenated compounds into a single exemplary chemical product, either β-ketoadipate or polyhydroxyalkanoates. This hybrid process establishes a strategy for the selective conversion of mixed plastics waste into useful chemical products.