Kun Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kun Hu has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Changyu Li
5 shared publicationsXiaohan Sun
5 shared publicationsGe Jin
4 shared publicationsYuying Li
4 shared publicationsBo Wang
Shandong University, Jinan, China
3 shared publications- Feng Li
Department of Astronomy, University of Science and Technology of China
3 shared publications
Latest Publications
- 19 April 2026
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 10 (5) , 1132-1140
Real-time data acquisition for atmospheric muography based on the thin gap chamber
- 19 April 2026
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 10 (5) , 1132-1140
Real-time data acquisition for atmospheric muography based on the thin gap chamber
- 4 January 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (2) , 26
Prototype of front-end electronics based on FPGA-ADC for TOF PET detector applications
- 4 January 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (2) , 26
Prototype of front-end electronics based on FPGA-ADC for TOF PET detector applications
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (8) , 2861-2867
Real Time Data Acquisition for PET Detector Evaluation Based on Dual-Polarity Charge-to-Digital Converter
Positron emission tomography (PET) is an indispensable medical image technology today. An advanced data acquisition system (DAQ) based on dual-polarity charge-to-digital converter (dQDC) for PET detector application was proposed. The DAQ consists of two parts: analog board and digital board. The analog board assembles all analog components in the dQDC scheme while the core of the digital board is a low-cost field programmable gate array (FPGA). In the dQDC implementations, the single-ended voltage-referenced receivers in the FPGA serve as voltage comparators. Under this configuration, two input/output (I/O) pins of the FPGA can be used to perform one-channel charge measurement. Taking advantage of abundant I/O resources in the FPGA, a multi-channel DAQ based on the dQDC scheme can be quickly customized. Totally 128 channels of dQDCs are integrated in the DAQ on the 80×80 mm2 area. To confirm the readout capability of the DAQ, a PET detector was constructed, which consisted of a 15 × 15 array of 1.5 × 1.5 × 20 mm3 LYSO bars coupled with a SiPM detector at one end. The energy resolution of the PET detector ranges from 13.11% to 22.71%. To measure the timing performance of the PET detector, a reference detector was applied. With the DAQ system, experimental results showed that the coincidence timing resolution (CTR) of the two detectors can reach up to 722.9 ps in full width at half maximum (FWHM). This new dQDC scheme is very promising for the low-cost DAQ with hundreds of channels.
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (8) , 2861-2867
Real Time Data Acquisition for PET Detector Evaluation Based on Dual-Polarity Charge-to-Digital Converter
Positron emission tomography (PET) is an indispensable medical image technology today. An advanced data acquisition system (DAQ) based on dual-polarity charge-to-digital converter (dQDC) for PET detector application was proposed. The DAQ consists of two parts: analog board and digital board. The analog board assembles all analog components in the dQDC scheme while the core of the digital board is a low-cost field programmable gate array (FPGA). In the dQDC implementations, the single-ended voltage-referenced receivers in the FPGA serve as voltage comparators. Under this configuration, two input/output (I/O) pins of the FPGA can be used to perform one-channel charge measurement. Taking advantage of abundant I/O resources in the FPGA, a multi-channel DAQ based on the dQDC scheme can be quickly customized. Totally 128 channels of dQDCs are integrated in the DAQ on the 80×80 mm2 area. To confirm the readout capability of the DAQ, a PET detector was constructed, which consisted of a 15 × 15 array of 1.5 × 1.5 × 20 mm3 LYSO bars coupled with a SiPM detector at one end. The energy resolution of the PET detector ranges from 13.11% to 22.71%. To measure the timing performance of the PET detector, a reference detector was applied. With the DAQ system, experimental results showed that the coincidence timing resolution (CTR) of the two detectors can reach up to 722.9 ps in full width at half maximum (FWHM). This new dQDC scheme is very promising for the low-cost DAQ with hundreds of channels.
- 17 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (3) , 309-315
An FPGA-Based ADC Using Multichain Merged Method
A soft-core analog-to-digital converter (ADC) based on multi-chain merged time-to-digital converter (TDC) is proposed. In hardware design, it only requires one resistor and an FPGA. The soft-core ADC is implemented in the FPGA. The FPGA-based ADC (FPGA-ADC) need to be calibrated including TDC length calibration, TDC alignment calibration and TDC-to-ADC code calibration. We implement the FPGA-ADCs with 1-, 2-, 4-, 6-, 8-chain merged TDC. The resulting FPGA-ADC can achieve a best resolution of more than 10 bits and a best 6.7 bits effective number of bits (ENOB) over a 0.67 to 2.03 V input dynamic range at a 200 MS/s sampling rate. The advantages of the proposed soft-core ADC are its compact size, reconfigurability and high resolution, which provides a feasible approach to achieve different readout electronics system on single hardware platform.
- 17 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (3) , 309-315
An FPGA-Based ADC Using Multichain Merged Method
A soft-core analog-to-digital converter (ADC) based on multi-chain merged time-to-digital converter (TDC) is proposed. In hardware design, it only requires one resistor and an FPGA. The soft-core ADC is implemented in the FPGA. The FPGA-based ADC (FPGA-ADC) need to be calibrated including TDC length calibration, TDC alignment calibration and TDC-to-ADC code calibration. We implement the FPGA-ADCs with 1-, 2-, 4-, 6-, 8-chain merged TDC. The resulting FPGA-ADC can achieve a best resolution of more than 10 bits and a best 6.7 bits effective number of bits (ENOB) over a 0.67 to 2.03 V input dynamic range at a 200 MS/s sampling rate. The advantages of the proposed soft-core ADC are its compact size, reconfigurability and high resolution, which provides a feasible approach to achieve different readout electronics system on single hardware platform.
- 18 February 2023
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 34 (2) , 1-12
Design and development of multi-channel front end electronics based on dual-polarity charge-to-digital converter for SiPM detector applications
- 18 February 2023
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 34 (2) , 1-12
Design and development of multi-channel front end electronics based on dual-polarity charge-to-digital converter for SiPM detector applications