Laurent Marmoret
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Laurent Marmoret has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Hassen Beji
Université de Picardie Jules Verne, LTI, IUT, Département Génie Civil, Amiens Cedex, France
3 shared publicationsAnne Perwuelz
Laboratoire GEMTEX, Ecole Nationale des Arts et Industries Textiles (ENSAIT), 2 allée Louise et Victor Champier, BP 30329, 59056 Roubaix Cedex 1, France
1 shared publicationFlorence Collet
1 shared publication- Fouzia Achchaq
Laboratoire des Technologies Innovantes, IUT-Département Génie Civil, Avenue des Facultés-Le Bailly, 80000 Amiens, France
1 shared publication - Hussein Humaish
Middle Technical University, Technical Institute, Department of Surveying, Al-Kut, Iraq
1 shared publication Karim Djellab
1 shared publication
Latest Publications
- Open Access
- 1 April 2026
- Published by Elsevier in SSRN Electronic Journal
RC network modeling to improve thermal properties determination of glass wool materials using hot wire probe
The cylindrical hot wire probe is widely regarded as the most suitable transient technique for determining thermal properties in situ. While standard methods yield consistent thermal conductivity (λ) values for homogeneous materials, significant deviations occur when experimental thermograms exhibit a pronounced S-shaped curve, typical of highly porous materials.The λ value (Standard Method Limitations) is highly sensitive to the selection of the time interval [t1,t2]. In the presence of high contact resistance or high porosity, the linear regime is delayed; if the "long-term" condition is not strictly met, this often leads to an overestimation of thermal conductivity.This study addresses these limitations by employing the Jaeger model, which accounts for the probe’s heat capacity and the contact resistance (Rc). Unlike the standard method, this approach fits the entire thermogram, including early-stage non-linearities. This results in a more stable and physically accurate determination of λ, independent of arbitrary time-window selection.A major advantage of the Jaeger model over standard techniques is its ability to simultaneously identify multiple parameters via inverse modeling. Beyond thermal conductivity, this methodology allows for the extraction of volumetric heat capacity (ρCp) and thermal contact resistance (Rc).The proposed method involves partitioning the sigmoid curve into three distinct parts. A thermal-electrical analogy based on the sigmoid's profile is first utilized to estimate thermal characteristics (conductivity and diffusivity) before final validation using the Jaeger model.
- 1 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessRC network modeling to improve thermal properties determination of glass wool materials using hot wire probe
The cylindrical hot wire probe is widely regarded as the most suitable transient technique for determining thermal properties in situ. While standard methods yield consistent thermal conductivity (λ) values for homogeneous materials, significant deviations occur when experimental thermograms exhibit a pronounced S-shaped curve, typical of highly porous materials.The λ value (Standard Method Limitations) is highly sensitive to the selection of the time interval [t1,t2]. In the presence of high contact resistance or high porosity, the linear regime is delayed; if the "long-term" condition is not strictly met, this often leads to an overestimation of thermal conductivity.This study addresses these limitations by employing the Jaeger model, which accounts for the probe’s heat capacity and the contact resistance (Rc). Unlike the standard method, this approach fits the entire thermogram, including early-stage non-linearities. This results in a more stable and physically accurate determination of λ, independent of arbitrary time-window selection.A major advantage of the Jaeger model over standard techniques is its ability to simultaneously identify multiple parameters via inverse modeling. Beyond thermal conductivity, this methodology allows for the extraction of volumetric heat capacity (ρCp) and thermal contact resistance (Rc).The proposed method involves partitioning the sigmoid curve into three distinct parts. A thermal-electrical analogy based on the sigmoid's profile is first utilized to estimate thermal characteristics (conductivity and diffusivity) before final validation using the Jaeger model.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 137-141
Effect of thermal inertia (time lag and decrement factor) on the insulation thermal capacity
In this study, global thermal capacity of glass wool wall by using flowmeter method has been investigated experimentally. For this purpose, guarded hot box has been used to provide heat transfer through the sample. Two flowmeters have been fixed one the surfaces of the wall (one fixed on the hot side and other fixed on the cold side). Thermal capacity has been obtained after the steady state is reached to the equilibrium by integral the area between the heat flow curve and cold flow curve. The study showed the effect of time lag and decrement factor on the thermal capacity. The results of present study are useful to evaluate thermal inertia properties of glass wool during transfer heat wave through building envelop.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 137-141
Effect of thermal inertia (time lag and decrement factor) on the insulation thermal capacity
In this study, global thermal capacity of glass wool wall by using flowmeter method has been investigated experimentally. For this purpose, guarded hot box has been used to provide heat transfer through the sample. Two flowmeters have been fixed one the surfaces of the wall (one fixed on the hot side and other fixed on the cold side). Thermal capacity has been obtained after the steady state is reached to the equilibrium by integral the area between the heat flow curve and cold flow curve. The study showed the effect of time lag and decrement factor on the thermal capacity. The results of present study are useful to evaluate thermal inertia properties of glass wool during transfer heat wave through building envelop.
- Open Access
- 6 March 2013
- Published by Wiley in ISRN Civil Engineering
- Vol. 2013, 1-8
Infiltration Kinetics of Wetting in a Building Plaster and the Effect of Added Glass and Hemp Fibers
Capillary rise is an important cause of deterioration for plaster in building. This phenomenon has been studied by the tensiometric experimental technique. Structural and hydric characteristics of plaster have been determined. Decane, a perfectly impregnate fluid, has been used to calculate the porous constant characteristic called and other structural parameters like pore radius and specific surface. Evaluation of the sensibility of plaster for water has been evaluated in a second time. The angle constant and the capillary moisture content have been determined. A comparison between results for plaster and composite plaster with fiber has been done. The addition of glass and hemp fiber does not have important effect on hydric properties (angle constant), but we have observed influence on structural charecteristics (pore radius, porosity, and degree of heterogeneity).
- 6 March 2013
- Published by Wiley in ISRN Civil Engineering
- Vol. 2013, 1-8
Open AccessInfiltration Kinetics of Wetting in a Building Plaster and the Effect of Added Glass and Hemp Fibers
Capillary rise is an important cause of deterioration for plaster in building. This phenomenon has been studied by the tensiometric experimental technique. Structural and hydric characteristics of plaster have been determined. Decane, a perfectly impregnate fluid, has been used to calculate the porous constant characteristic called and other structural parameters like pore radius and specific surface. Evaluation of the sensibility of plaster for water has been evaluated in a second time. The angle constant and the capillary moisture content have been determined. A comparison between results for plaster and composite plaster with fiber has been done. The addition of glass and hemp fiber does not have important effect on hydric properties (angle constant), but we have observed influence on structural charecteristics (pore radius, porosity, and degree of heterogeneity).
- 1 February 2011
- Published by Elsevier in Construction and Building Materials
- Vol. 25 (2) , 1079-1085
Water vapor properties of two hemp wools manufactured with different treatments
- 1 February 2011
- Published by Elsevier in Construction and Building Materials
- Vol. 25 (2) , 1079-1085
Water vapor properties of two hemp wools manufactured with different treatments