Matthias Schlachter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matthias Schlachter has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Katja Bühler
Biomedical Image Informatics, VRVis GmbH, Vienna, Austria
4 shared publications Sonja Adebahr
Department of Radiation Oncology, University Medical Center Freiburg, Freiburg, Germany
2 shared publications- Tobias Fechter
Department of Radiation Oncology, Medical Center - University of Freiburg, Freiburg, Germany
2 shared publications Ursula Nestle
Department of Radiation Oncology, University Medical Center Freiburg, Freiburg, Germany
2 shared publicationsBernhard Preim
University of Magdeburg, Magdeburg, Germany
1 shared publication- Charissa Poon
Center for Brain Science, RIKEN
1 shared publication
Latest Publications
- 5 October 2025
- Published by Springer Nature
- p. 87-102
Benchmarking Evaluation Metrics for Tubular Structure Segmentation in Biomedical Images
- 5 October 2025
- Published by Springer Nature
- p. 87-102
Benchmarking Evaluation Metrics for Tubular Structure Segmentation in Biomedical Images
- 22 September 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 166, 107523
Exploration of overlap volumes for radiotherapy plan evaluation with the aim of healthy tissue sparing
- 22 September 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 166, 107523
Exploration of overlap volumes for radiotherapy plan evaluation with the aim of healthy tissue sparing
- 15 January 2020
- Published by S. Karger AG in Oncology
- Vol. 98 (6) , 412-422
Principles of Visualization in Radiation Oncology
Background: Medical visualization employs elements from computer graphics to create meaningful, interactive visual representations of medical data, and it has become an influential field of research for many advanced applications like radiation oncology, among others. Visual representations employ the user’s cognitive capabilities to support and accelerate diagnostic, planning, and quality assurance workflows based on involved patient data. Summary: This article discusses the basic underlying principles of visualization in the application domain of radiation oncology. The main visualization strategies, such as slice-based representations and surface and volume rendering are presented. Interaction topics, i.e., the combination of visualization and automated analysis methods, are also discussed. Key Messages: Slice-based representations are a common approach in radiation oncology, while volume visualization also has a long-standing history in the field. Perception within both representations can benefit further from advanced approaches, such as image fusion and multivolume or hybrid rendering. While traditional slice-based and volume representations keep evolving, the dimensionality and complexity of medical data are also increasing. To address this, visual analytics strategies are valuable, particularly for cohort or uncertainty visualization. Interactive visual analytics approaches represent a new opportunity to integrate knowledgeable experts and their cognitive abilities in exploratory processes which cannot be conducted by solely automatized methods.
- 15 January 2020
- Published by S. Karger AG in Oncology
- Vol. 98 (6) , 412-422
Principles of Visualization in Radiation Oncology
Background: Medical visualization employs elements from computer graphics to create meaningful, interactive visual representations of medical data, and it has become an influential field of research for many advanced applications like radiation oncology, among others. Visual representations employ the user’s cognitive capabilities to support and accelerate diagnostic, planning, and quality assurance workflows based on involved patient data. Summary: This article discusses the basic underlying principles of visualization in the application domain of radiation oncology. The main visualization strategies, such as slice-based representations and surface and volume rendering are presented. Interaction topics, i.e., the combination of visualization and automated analysis methods, are also discussed. Key Messages: Slice-based representations are a common approach in radiation oncology, while volume visualization also has a long-standing history in the field. Perception within both representations can benefit further from advanced approaches, such as image fusion and multivolume or hybrid rendering. While traditional slice-based and volume representations keep evolving, the dimensionality and complexity of medical data are also increasing. To address this, visual analytics strategies are valuable, particularly for cohort or uncertainty visualization. Interactive visual analytics approaches represent a new opportunity to integrate knowledgeable experts and their cognitive abilities in exploratory processes which cannot be conducted by solely automatized methods.
- Open Access
- 29 October 2017
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 18 (6) , 183-193
Visualization of 4D multimodal imaging data and its applications in radiotherapy planning
Purpose: To explore the benefit of using 4D multimodal visualization and interaction techniques for defined radiotherapy planning tasks over a treatment planning system used in clinical routine (C‐TPS) without dedicated 4D visualization.Methods: We developed a 4D visualization system (4D‐VS) with dedicated rendering and fusion of 4D multimodal imaging data based on a list of requirements developed in collaboration with radiation oncologists. We conducted a user evaluation in which the benefits of our approach were evaluated in comparison to C‐TPSfor three specific tasks: assessment of internal target volume (ITV) delineation, classification of tumor location in peripheral or central, and assessment of dose distribution. For all three tasks, we presented test cases for which we measured correctness, certainty, consistency followed by an additional survey regarding specific visualization features.Results: Lower quality of the testITVs (ground truth quality was available) was more likely to be detected using 4D‐VS.ITVratings were more consistent in 4D‐VSand the classification of tumor location had a higher accuracy. Overall evaluation of the survey indicates 4D‐VSprovides better spatial comprehensibility and simplifies the tasks which were performed during testing.Conclusions: The use of 4D‐VShas improved the assessment ofITVdelineations and classification of tumor location. The visualization features of 4D‐VShave been identified as helpful for the assessment of dose distribution during user testing.
- 29 October 2017
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 18 (6) , 183-193
Open AccessVisualization of 4D multimodal imaging data and its applications in radiotherapy planning
Purpose: To explore the benefit of using 4D multimodal visualization and interaction techniques for defined radiotherapy planning tasks over a treatment planning system used in clinical routine (C‐TPS) without dedicated 4D visualization.Methods: We developed a 4D visualization system (4D‐VS) with dedicated rendering and fusion of 4D multimodal imaging data based on a list of requirements developed in collaboration with radiation oncologists. We conducted a user evaluation in which the benefits of our approach were evaluated in comparison to C‐TPSfor three specific tasks: assessment of internal target volume (ITV) delineation, classification of tumor location in peripheral or central, and assessment of dose distribution. For all three tasks, we presented test cases for which we measured correctness, certainty, consistency followed by an additional survey regarding specific visualization features.Results: Lower quality of the testITVs (ground truth quality was available) was more likely to be detected using 4D‐VS.ITVratings were more consistent in 4D‐VSand the classification of tumor location had a higher accuracy. Overall evaluation of the survey indicates 4D‐VSprovides better spatial comprehensibility and simplifies the tasks which were performed during testing.Conclusions: The use of 4D‐VShas improved the assessment ofITVdelineations and classification of tumor location. The visualization features of 4D‐VShave been identified as helpful for the assessment of dose distribution during user testing.
- 29 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 35 (10) , 2319-2328
Visualization of Deformable Image Registration Quality Using Local Image Dissimilarity
Deformable image registration (DIR) has the potential to improve modern radiotherapy in many aspects, including volume definition, treatment planning and image-guided adaptive radiotherapy. Studies have shown its possible clinical benefits. However, measuring DIR accuracy is difficult without known ground truth, but necessary before integration in the radiotherapy workflow. Visual assessment is an important step towards clinical acceptance. We propose a visualization framework which supports the exploration and the assessment of DIR accuracy. It offers different interaction and visualization features for exploration of candidate regions to simplify the process of visual assessment. The visualization is based on voxel-wise comparison of local image patches for which dissimilarity measures are computed and visualized to indicate locally the registration results. We performed an evaluation with three radiation oncologists to demonstrate the viability of our approach. In the evaluation, lung regions were rated by the participants with regards to their visual accuracy and compared to the registration error measured with expert defined landmarks. Regions rated as “accepted” had an average registration error of 1.8 mm, with the highest single landmark error being 3.3 mm. Additionally, survey results show that the proposed visualizations support a fast and intuitive investigation of DIR accuracy, and are suitable for finding even small errors.
- 29 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 35 (10) , 2319-2328
Visualization of Deformable Image Registration Quality Using Local Image Dissimilarity
Deformable image registration (DIR) has the potential to improve modern radiotherapy in many aspects, including volume definition, treatment planning and image-guided adaptive radiotherapy. Studies have shown its possible clinical benefits. However, measuring DIR accuracy is difficult without known ground truth, but necessary before integration in the radiotherapy workflow. Visual assessment is an important step towards clinical acceptance. We propose a visualization framework which supports the exploration and the assessment of DIR accuracy. It offers different interaction and visualization features for exploration of candidate regions to simplify the process of visual assessment. The visualization is based on voxel-wise comparison of local image patches for which dissimilarity measures are computed and visualized to indicate locally the registration results. We performed an evaluation with three radiation oncologists to demonstrate the viability of our approach. In the evaluation, lung regions were rated by the participants with regards to their visual accuracy and compared to the registration error measured with expert defined landmarks. Regions rated as “accepted” had an average registration error of 1.8 mm, with the highest single landmark error being 3.3 mm. Additionally, survey results show that the proposed visualizations support a fast and intuitive investigation of DIR accuracy, and are suitable for finding even small errors.