Gianluca Mazzucco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gianluca Mazzucco has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Valentina Salomoni
Department of Management and Engineering (DTG), University of Padova, Stradella S. Nicola 3, 36100, Vicenza, Italy
8 shared publications - Giovanna Xotta
Department of Civil, Architectural and Environmental Engineering (DICEA), University of Padova, via F. Marzolo 9 35131, Padova, Italy
7 shared publications - Beatrice Pomaro
University of Padua
6 shared publications - Carmelo E. Majorana
Department of Civil, Environmental and Architectural Engineering (DICEA), University of Padova, Via F. Marzolo, 35131 Padova, Italy
4 shared publications B. Pomaro
3 shared publicationsV.A. Salomoni
3 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 8 (4) , 042002
Effects of ionizing radiation on bone microstructure and biomechanical properties: a systematic review in clinical and aerospace contexts
Introduction . This review examines the impact of ionizing radiation on bone microstructure and mechanical properties in murine models, with particular attention to how different radiation types, total absorbed doses, and dose rates influence skeletal tissue. The topic is highly relevant in both radiotherapy and aerospace research, two different scenarios but that share important skeletal consequences, such as disturbances in bone remodeling, deterioration of trabecular and cortical microarchitecture, and reductions in mechanical strength. Methods . This review was conducted following PRISMA guidelines, with a structured search across Scopus, PubMed, and Google Scholar using predefined keywords and Boolean operators. Experimental murine studies investigating the effects of ionizing radiation in radiotherapy- or spaceflight-simulating settings were considered eligible if they reported at least one bone morphological and one mechanical outcome. After screening and eligibility assessment, 11 studies were included and evaluated for methodological quality based on the robustness of the reported morphological and mechanical analyses. Results . The included studies indicate that radiation exposure in murine bone is associated with dose-, time-, and radiation quality-dependent deterioration, with early, transient effects after single doses and more persistent damage following repeated exposures. Trabecular bone emerged as the most vulnerable compartment, showing reduced trabecular number and increased separation across several studies. Mechanical outcomes appeared to be site-specific: cortical-rich bones often retain strength despite trabecular loss, whereas trabecular-rich sites appeared more susceptible, suggesting microstructural deterioration may contribute to functional impairment even when whole-bone strength is relatively preserved. Conclusions . These findings highlight that trabecular bone is the primary target of radiation-induced damage, with site-specific effects and persistent mechanical deficits, emphasizing the importance of multiscale assessment to understand and mitigate skeletal fragility in clinical and spaceflight contexts. However, a limited number of eligible studies and heterogeneity of experimental designs could reduce the strength of direct comparisons and the generalizability of these conclusions.
- 1 September 2026
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 8 (4) , 042002
Open AccessEffects of ionizing radiation on bone microstructure and biomechanical properties: a systematic review in clinical and aerospace contexts
Introduction . This review examines the impact of ionizing radiation on bone microstructure and mechanical properties in murine models, with particular attention to how different radiation types, total absorbed doses, and dose rates influence skeletal tissue. The topic is highly relevant in both radiotherapy and aerospace research, two different scenarios but that share important skeletal consequences, such as disturbances in bone remodeling, deterioration of trabecular and cortical microarchitecture, and reductions in mechanical strength. Methods . This review was conducted following PRISMA guidelines, with a structured search across Scopus, PubMed, and Google Scholar using predefined keywords and Boolean operators. Experimental murine studies investigating the effects of ionizing radiation in radiotherapy- or spaceflight-simulating settings were considered eligible if they reported at least one bone morphological and one mechanical outcome. After screening and eligibility assessment, 11 studies were included and evaluated for methodological quality based on the robustness of the reported morphological and mechanical analyses. Results . The included studies indicate that radiation exposure in murine bone is associated with dose-, time-, and radiation quality-dependent deterioration, with early, transient effects after single doses and more persistent damage following repeated exposures. Trabecular bone emerged as the most vulnerable compartment, showing reduced trabecular number and increased separation across several studies. Mechanical outcomes appeared to be site-specific: cortical-rich bones often retain strength despite trabecular loss, whereas trabecular-rich sites appeared more susceptible, suggesting microstructural deterioration may contribute to functional impairment even when whole-bone strength is relatively preserved. Conclusions . These findings highlight that trabecular bone is the primary target of radiation-induced damage, with site-specific effects and persistent mechanical deficits, emphasizing the importance of multiscale assessment to understand and mitigate skeletal fragility in clinical and spaceflight contexts. However, a limited number of eligible studies and heterogeneity of experimental designs could reduce the strength of direct comparisons and the generalizability of these conclusions.
- Open Access
- 4 August 2026
- Published by Elsevier in Engineering Fracture Mechanics
- Vol. 345
Modeling interlayer interfaces in 3D-printed concrete using a coupled cohesive contact approach
- 4 August 2026
- Published by Elsevier in Engineering Fracture Mechanics
- Vol. 345
Open AccessModeling interlayer interfaces in 3D-printed concrete using a coupled cohesive contact approach
- Open Access
- 14 June 2026
- Published by Elsevier in Computers & Structures
- Vol. 330
Combined FEM-DEM approach for concrete mesoscale modeling
- 14 June 2026
- Published by Elsevier in Computers & Structures
- Vol. 330
Open AccessCombined FEM-DEM approach for concrete mesoscale modeling
- Open Access
- 2 April 2025
- Published by Elsevier in European Journal of Mechanics - A/Solids
- Vol. 112
A 3D visco-elasto-plastic damage constitutive model of concrete under long-term loads
- 2 April 2025
- Published by Elsevier in European Journal of Mechanics - A/Solids
- Vol. 112
Open AccessA 3D visco-elasto-plastic damage constitutive model of concrete under long-term loads
- Open Access
- 25 December 2024
- Published by Wiley in BJUI Compass
- Vol. 6 (1) , e473
In silico tools for mechanical analysis of extra‐ and intra‐luminal artificial urinary sphincters
Objectives: To analyse and compare the functionality of extraluminal and intraluminal artificial urinary sphincters (AUSs), an in silico procedure has been defined and applied. Design and reliability assessments of the AUS are typically performed using a clinical approach, which does not provide data on mechanical stimulation of urethral tissues. Mechanical stimulation may determine tissue degeneration, such as urethral atrophy or erosion, the main causes of AUS failure. In silico techniques can provide a quantitative description of stress and strain fields due to the interaction between tissues and AUS and allow investigating an extremely large number of situations, considering different configurations of AUS and urethra.Materials and Methods: Computational investigations were carried out to evaluate the mechanical reliability of the main extraluminal and intraluminal AUS, AMS 800 and Relief. The lower urinary tract was modelled based on previous experiments. The AUS models took into account the main components that interact with biological tissues. Urethra and AUS models were coupled and used to investigate mechanical stimulation of urethral tissues.Results: In silico simulations provide quantitative information about the mechanical stimulation of urethral tissue, such as compressive strain and stress and hydrostatic pressure, due to interaction with the AUS. Such mechanical quantities allow a comparison of reliability between extraluminal and intraluminal devices.Conclusions: The activities define and demonstrate the effectiveness of a novel in silico approach to the design and reliability assessment of AUS devices, increasing the investigative possibilities and reducing the time, ethical and economic costs.
- 25 December 2024
- Published by Wiley in BJUI Compass
- Vol. 6 (1) , e473
Open AccessIn silico tools for mechanical analysis of extra‐ and intra‐luminal artificial urinary sphincters
Objectives: To analyse and compare the functionality of extraluminal and intraluminal artificial urinary sphincters (AUSs), an in silico procedure has been defined and applied. Design and reliability assessments of the AUS are typically performed using a clinical approach, which does not provide data on mechanical stimulation of urethral tissues. Mechanical stimulation may determine tissue degeneration, such as urethral atrophy or erosion, the main causes of AUS failure. In silico techniques can provide a quantitative description of stress and strain fields due to the interaction between tissues and AUS and allow investigating an extremely large number of situations, considering different configurations of AUS and urethra.Materials and Methods: Computational investigations were carried out to evaluate the mechanical reliability of the main extraluminal and intraluminal AUS, AMS 800 and Relief. The lower urinary tract was modelled based on previous experiments. The AUS models took into account the main components that interact with biological tissues. Urethra and AUS models were coupled and used to investigate mechanical stimulation of urethral tissues.Results: In silico simulations provide quantitative information about the mechanical stimulation of urethral tissue, such as compressive strain and stress and hydrostatic pressure, due to interaction with the AUS. Such mechanical quantities allow a comparison of reliability between extraluminal and intraluminal devices.Conclusions: The activities define and demonstrate the effectiveness of a novel in silico approach to the design and reliability assessment of AUS devices, increasing the investigative possibilities and reducing the time, ethical and economic costs.
- Open Access
- 19 September 2024
- Published by Elsevier in Computers & Structures
- Vol. 305
Three-dimensional meso-scale modeling of asphalt concrete
- 19 September 2024
- Published by Elsevier in Computers & Structures
- Vol. 305
Open AccessThree-dimensional meso-scale modeling of asphalt concrete
- Open Access
- 7 August 2024
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 431
Efficient AMG reduction-based preconditioners for structural mechanics
- 7 August 2024
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 431
Open AccessEfficient AMG reduction-based preconditioners for structural mechanics
- 12 October 2023
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 264
A 3D coupled thermo-mechanical and neutron diffusion numerical model for irradiated concrete
- 12 October 2023
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 264
A 3D coupled thermo-mechanical and neutron diffusion numerical model for irradiated concrete
- 27 November 2021
- Published by Springer Nature
- p. 2073-2082
A Cohesive Contact Algorithm to Describe the Multi-axial Bond Behavior of FRCM Composites
- 27 November 2021
- Published by Springer Nature
- p. 2073-2082
A Cohesive Contact Algorithm to Describe the Multi-axial Bond Behavior of FRCM Composites
- 1 August 2021
- Published by Elsevier in Construction and Building Materials
- Vol. 294, 123479
A cohesive contact algorithm to evaluate the mechanical behaviour of concrete ITZ at different roughness conditions
- 1 August 2021
- Published by Elsevier in Construction and Building Materials
- Vol. 294, 123479
A cohesive contact algorithm to evaluate the mechanical behaviour of concrete ITZ at different roughness conditions