Erik Henne
Research Subjects
Erik Henne has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Felix J. F. Herth
Pneumology and Critical Care Medicine, Thoraxklinik, University of Heidelberg, Heidelberg, Germany
3 shared publications Greg Snell
Allergy Immunology and Respiratory Medicine, The Alfred Hospital, Melbourne, Vic., Australia
2 shared publications- Joseph C. Anderson
Department of Bioengineering, University of Washington, Seattle, USA
2 shared publications Robert Barry
Uptake Medical, Tustin, Calif
2 shared publicationsArschang Valipour
Department of Respiratory and Critical Care Medicine, Ludwig Boltzmann Institute for COPD, Otto Wagner Hospital, Vienna, Austria
1 shared publicationAvina Gupta
Uptake Medical Tustin Calif USA
1 shared publication
Latest Publications
- Open Access
- 3 October 2015
- Published by S. Karger AG in Respiration
- Vol. 90 (5) , 402-411
Patterns of Emphysema Heterogeneity
Background: Although lobar patterns of emphysema heterogeneity are indicative of optimal target sites for lung volume reduction (LVR) strategies, the presence of segmental, or sublobar, heterogeneity is often underappreciated. Objective: The aim of this study was to understand lobar and segmental patterns of emphysema heterogeneity, which may more precisely indicate optimal target sites for LVR procedures. Methods: Patterns of emphysema heterogeneity were evaluated in a representative cohort of 150 severe (GOLD stage III/IV) chronic obstructive pulmonary disease (COPD) patients from the COPDGene study. High-resolution computerized tomography analysis software was used to measure tissue destruction throughout the lungs to compute heterogeneity (≥15% difference in tissue destruction) between (inter-) and within (intra-) lobes for each patient. Emphysema tissue destruction was characterized segmentally to define patterns of heterogeneity. Results: Segmental tissue destruction revealed interlobar heterogeneity in the left lung (57%) and right lung (52%). Intralobar heterogeneity was observed in at least one lobe of all patients. No patient presented true homogeneity at a segmental level. There was true homogeneity across both lungs in 3% of the cohort when defining heterogeneity as ≥30% difference in tissue destruction. Conclusion: Many LVR technologies for treatment of emphysema have focused on interlobar heterogeneity and target an entire lobe per procedure. Our observations suggest that a high proportion of patients with emphysema are affected by interlobar as well as intralobar heterogeneity. These findings prompt the need for a segmental approach to LVR in the majority of patients to treat only the most diseased segments and preserve healthier ones.
- 3 October 2015
- Published by S. Karger AG in Respiration
- Vol. 90 (5) , 402-411
Open AccessPatterns of Emphysema Heterogeneity
Background: Although lobar patterns of emphysema heterogeneity are indicative of optimal target sites for lung volume reduction (LVR) strategies, the presence of segmental, or sublobar, heterogeneity is often underappreciated. Objective: The aim of this study was to understand lobar and segmental patterns of emphysema heterogeneity, which may more precisely indicate optimal target sites for LVR procedures. Methods: Patterns of emphysema heterogeneity were evaluated in a representative cohort of 150 severe (GOLD stage III/IV) chronic obstructive pulmonary disease (COPD) patients from the COPDGene study. High-resolution computerized tomography analysis software was used to measure tissue destruction throughout the lungs to compute heterogeneity (≥15% difference in tissue destruction) between (inter-) and within (intra-) lobes for each patient. Emphysema tissue destruction was characterized segmentally to define patterns of heterogeneity. Results: Segmental tissue destruction revealed interlobar heterogeneity in the left lung (57%) and right lung (52%). Intralobar heterogeneity was observed in at least one lobe of all patients. No patient presented true homogeneity at a segmental level. There was true homogeneity across both lungs in 3% of the cohort when defining heterogeneity as ≥30% difference in tissue destruction. Conclusion: Many LVR technologies for treatment of emphysema have focused on interlobar heterogeneity and target an entire lobe per procedure. Our observations suggest that a high proportion of patients with emphysema are affected by interlobar as well as intralobar heterogeneity. These findings prompt the need for a segmental approach to LVR in the majority of patients to treat only the most diseased segments and preserve healthier ones.
- Open Access
- 8 July 2015
- Published by S. Karger AG in Respiration
- Vol. 90 (2) , 146-154
Thermal Vapor Ablation for Lung Lesions in a Porcine Model
Background: Various methods for ablating peripheral lung lesions are being investigated; however, none have been successfully adapted for delivery via bronchoscopy. Vapor ablation is currently being used to bronchoscopically create lung volume reduction in emphysema patients. Objectives: In this study, an adaptation of that technology is evaluated for potential treatment of lung lesions in a live pig model. Methods: In 5 anesthetized healthy pigs, vapor of varying energy levels was delivered bronchoscopically to 66 different lung subsegments with airway diameters of 2-5 mm. Two hours after treatment, a necropsy was performed and the ablated regions were assessed for ablation and tissue structure disruption. In 6 additional pigs, vapor was applied to 3 subsegments each. To evaluate the progression of the response to treatment, 2 were kept alive for 10 days, 2 for 21 days, and 2 for 32 days. Results: Histopathological evaluation of the sections demonstrated that vapor is capable of creating a uniform field of necrosis following the subsegment anatomical boundary. The reliability of a uniform field is dependent on the level of energy delivered. An energy level that reliably creates a uniform field of necrosis was applied in chronic animals. The animals tolerated the procedure and posttreatment care. No cardiac arrhythmias, hemorrhage, stroke, respiratory distress, or pneumothorax occurred during or after treatment. Conclusions: Vapor ablation is a potentially safe and efficient means of ablating a targeted region of the lung. We hypothesize that vapor may be useful in treating lesions of the lung in humans.
- 8 July 2015
- Published by S. Karger AG in Respiration
- Vol. 90 (2) , 146-154
Open AccessThermal Vapor Ablation for Lung Lesions in a Porcine Model
Background: Various methods for ablating peripheral lung lesions are being investigated; however, none have been successfully adapted for delivery via bronchoscopy. Vapor ablation is currently being used to bronchoscopically create lung volume reduction in emphysema patients. Objectives: In this study, an adaptation of that technology is evaluated for potential treatment of lung lesions in a live pig model. Methods: In 5 anesthetized healthy pigs, vapor of varying energy levels was delivered bronchoscopically to 66 different lung subsegments with airway diameters of 2-5 mm. Two hours after treatment, a necropsy was performed and the ablated regions were assessed for ablation and tissue structure disruption. In 6 additional pigs, vapor was applied to 3 subsegments each. To evaluate the progression of the response to treatment, 2 were kept alive for 10 days, 2 for 21 days, and 2 for 32 days. Results: Histopathological evaluation of the sections demonstrated that vapor is capable of creating a uniform field of necrosis following the subsegment anatomical boundary. The reliability of a uniform field is dependent on the level of energy delivered. An energy level that reliably creates a uniform field of necrosis was applied in chronic animals. The animals tolerated the procedure and posttreatment care. No cardiac arrhythmias, hemorrhage, stroke, respiratory distress, or pneumothorax occurred during or after treatment. Conclusions: Vapor ablation is a potentially safe and efficient means of ablating a targeted region of the lung. We hypothesize that vapor may be useful in treating lesions of the lung in humans.
- Open Access
- 6 December 2014
- Published by S. Karger AG in Respiration
- Vol. 89 (1) , 76-81
Segmental Approach to Lung Volume Reduction Therapy for Emphysema Patients
Emphysema is often distributed heterogeneously throughout the lungs, even at the segmental level. It is important for interventional lung volume reduction therapies to target and treat the most diseased regions of the lung while preserving the less diseased functional regions. Identification and determination of the severity of emphysema can be done using the various quantification measures reviewed in this article. However, all of these measures are similar in what they quantify and are equally good indicators of emphysema. The tissue/air ratio was chosen for our purposes. Software capable of quantifying emphysema severity at the segmental level exists, and can be utilized to identify the most diseased segments while following anatomical boundaries. The segmental heterogeneity index is a new measure being introduced to help quantify differences in emphysema severity at the segmental level. The goal of segmental targeting is to improve efficacy and safety outcomes of vapor ablation patients. The Sequential Staged Treatment of Emphysema with Upper Lobe Predominance (STEP-UP, NCT01719263) trial is currently enrolling patients with upper lobe heterogeneous emphysema using these techniques.
- 6 December 2014
- Published by S. Karger AG in Respiration
- Vol. 89 (1) , 76-81
Open AccessSegmental Approach to Lung Volume Reduction Therapy for Emphysema Patients
Emphysema is often distributed heterogeneously throughout the lungs, even at the segmental level. It is important for interventional lung volume reduction therapies to target and treat the most diseased regions of the lung while preserving the less diseased functional regions. Identification and determination of the severity of emphysema can be done using the various quantification measures reviewed in this article. However, all of these measures are similar in what they quantify and are equally good indicators of emphysema. The tissue/air ratio was chosen for our purposes. Software capable of quantifying emphysema severity at the segmental level exists, and can be utilized to identify the most diseased segments while following anatomical boundaries. The segmental heterogeneity index is a new measure being introduced to help quantify differences in emphysema severity at the segmental level. The goal of segmental targeting is to improve efficacy and safety outcomes of vapor ablation patients. The Sequential Staged Treatment of Emphysema with Upper Lobe Predominance (STEP-UP, NCT01719263) trial is currently enrolling patients with upper lobe heterogeneous emphysema using these techniques.
- Open Access
- 12 June 2012
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 28 (5) , 466-472
Thermal effect of endoscopic thermal vapour ablation on the lung surface in human ex vivo tissue
Purpose: An investigation of the thermal effect and the potential for injury at the lung surface following thermal vapour ablation (InterVapor), an energy-based method of achieving endoscopic lung volume reduction. Methods: Heated water vapour was delivered to fifteen ex vivo human lungs using standard clinical procedure, and the thermal effect at the visceral pleura was monitored with an infrared camera. The time–temperature response was analysed mathematically to determine a cumulative injury quotient, which was compared to published thresholds. Results: The cumulative injury quotients for all 71 treatments of ex vivo tissue were found to be below the threshold for first degree burn and no other markers of tissue injury at the lung surface were observed. Conclusion: The safety profile for thermal vapour ablation is further supported by the demonstration that the thermal effect in a worst-case model is not expected to cause injury at the lung surface.
- 12 June 2012
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 28 (5) , 466-472
Open AccessThermal effect of endoscopic thermal vapour ablation on the lung surface in human ex vivo tissue
Purpose: An investigation of the thermal effect and the potential for injury at the lung surface following thermal vapour ablation (InterVapor), an energy-based method of achieving endoscopic lung volume reduction. Methods: Heated water vapour was delivered to fifteen ex vivo human lungs using standard clinical procedure, and the thermal effect at the visceral pleura was monitored with an infrared camera. The time–temperature response was analysed mathematically to determine a cumulative injury quotient, which was compared to published thresholds. Results: The cumulative injury quotients for all 71 treatments of ex vivo tissue were found to be below the threshold for first degree burn and no other markers of tissue injury at the lung surface were observed. Conclusion: The safety profile for thermal vapour ablation is further supported by the demonstration that the thermal effect in a worst-case model is not expected to cause injury at the lung surface.
- Open Access
- 14 May 2012
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 12 (1) , 18
Comparison of human lung tissue mass measurements from Ex Vivo lungs and high resolution CT software analysis
Quantification of lung tissue via analysis of computed tomography (CT) scans is increasingly common for monitoring disease progression and for planning of therapeutic interventions. The current study evaluates the quantification of human lung tissue mass by software analysis of a CT to physical tissue mass measurements.
- 14 May 2012
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 12 (1) , 18
Open AccessComparison of human lung tissue mass measurements from Ex Vivo lungs and high resolution CT software analysis
Quantification of lung tissue via analysis of computed tomography (CT) scans is increasingly common for monitoring disease progression and for planning of therapeutic interventions. The current study evaluates the quantification of human lung tissue mass by software analysis of a CT to physical tissue mass measurements.