Amal Guezmil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Amal Guezmil has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Hanen Berriri
University of Monastir
11 shared publications Anis Sakly
Research Unit of Industrial Systems Study and Renewable Energy (ESIER), National Engineering School of Monastir, University of Monastir, Ibn Eljazzar City, Tunisia
9 shared publicationsMohamed Faouzi Mimouni
Research Unit of Industrial Systems Study and Renewable Energy (ESIER), National Engineering School of Monastir, University of Monastir, Ibn Eljazzar City, Tunisia
9 shared publicationsRaphael Romary
Research Unit of Industrial Systems Study and Renewable Energy (ESIER), National Engineering School of Monastir University of Monastir Monastir Tunisia
4 shared publicationsRemus Pusca
Research Unit of Industrial Systems Study and Renewable Energy (ESIER), National Engineering School of Monastir University of Monastir Monastir Tunisia
4 shared publicationsA. Sakly
Res. Unit on Study of the Ind. Syst. & Renewable Energies (ESIER), National Engineering School Monastir, Ibn Eljazzar City, 5019, Monastir, Tunisia
2 shared publications
Latest Publications
- 29 June 2019
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 45 (3) , 1447-1455
Sliding Mode-Based Active Fault-Tolerant Control for Induction Machine
- 29 June 2019
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 45 (3) , 1447-1455
Sliding Mode-Based Active Fault-Tolerant Control for Induction Machine
- 17 January 2019
- Published by Wiley in Asian Journal of Control
- Vol. 21 (1) , 33-42
High order sliding mode observer‐based backstepping fault‐tolerant control for induction motor
This paper presents a robust fault tolerant control for an induction motor in presence of inter‐turn short‐circuit fault. The control strategy is based on Backstepping approach and high order sliding mode observer. That ensures a high‐performance control and a good dynamic in presence of inter‐turn short‐circuit fault. The stability of the Backstepping control is proved by Lyapunov theory. A high order sliding mode observer is used for rotor flux estimation. The performances of the fault tolerant control scheme will be examined via numerical simulation and validated through hardware implementation using MATLAB/Simulink with dSpace signal card. The analysis' results show the robustness of the proposed method for the tolerance of the inter‐turn short‐circuit fault.
- 17 January 2019
- Published by Wiley in Asian Journal of Control
- Vol. 21 (1) , 33-42
High order sliding mode observer‐based backstepping fault‐tolerant control for induction motor
This paper presents a robust fault tolerant control for an induction motor in presence of inter‐turn short‐circuit fault. The control strategy is based on Backstepping approach and high order sliding mode observer. That ensures a high‐performance control and a good dynamic in presence of inter‐turn short‐circuit fault. The stability of the Backstepping control is proved by Lyapunov theory. A high order sliding mode observer is used for rotor flux estimation. The performances of the fault tolerant control scheme will be examined via numerical simulation and validated through hardware implementation using MATLAB/Simulink with dSpace signal card. The analysis' results show the robustness of the proposed method for the tolerance of the inter‐turn short‐circuit fault.
- 21 July 2018
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 46 (11-12) , 1351-1363
Unknown Input Observer-Based Fault Diagnosis in Induction Machine: Theory and Experiment
This paper presents an observer-based approach to diagnosis and detect inter-turn short-circuit fault in induction machine based on residual generation. Residual signals are generated by taking measured three-phase stator currents and those reconstructed by unknown input observer. By comparing these residuals to a predefined threshold, such fault can be detected and fault signatures are obtained. These signatures are used to develop a faulty phase isolation algorithm. The ability to detect the fault and isolate the faulty phase is tested by simulation and validated using experimental test bench with real-time interface based on the dSpace environment.
- 21 July 2018
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 46 (11-12) , 1351-1363
Unknown Input Observer-Based Fault Diagnosis in Induction Machine: Theory and Experiment
This paper presents an observer-based approach to diagnosis and detect inter-turn short-circuit fault in induction machine based on residual generation. Residual signals are generated by taking measured three-phase stator currents and those reconstructed by unknown input observer. By comparing these residuals to a predefined threshold, such fault can be detected and fault signatures are obtained. These signatures are used to develop a faulty phase isolation algorithm. The ability to detect the fault and isolate the faulty phase is tested by simulation and validated using experimental test bench with real-time interface based on the dSpace environment.
- 19 January 2018
- Published by Wiley in Asian Journal of Control
- Vol. 21 (1) , 520-532
Experimental Investigation of Passive Fault Tolerant Control for Induction Machine Using Sliding Mode Approach
This paper presents a passive fault tolerant control approach dedicated to stator inter‐turn short‐circuit fault of an induction machine. This control is based on sliding mode strategy and is implemented for validation on real‐time data acquisition and control platform. The proposed work highlights the integral sliding mode controller benefits during healthy and faulty operations. It can make the induction machine outputs to track their desired reference signals in finite‐time and allows to obtain a better dynamic response performances even in presence of fault. Moreover to avoid the use of a flux sensor, a second order sliding mode observer is used to estimate the rotor flux. Since the used observer converges in finite time, the closed‐loop stability of the proposed system (controller+observer) is proved using the Lyapunov stability theorem. Experimental results are conducted for squirrel cage induction machine to highlight the efficiency and applicability of the proposed fault tolerant control.
- 19 January 2018
- Published by Wiley in Asian Journal of Control
- Vol. 21 (1) , 520-532
Experimental Investigation of Passive Fault Tolerant Control for Induction Machine Using Sliding Mode Approach
This paper presents a passive fault tolerant control approach dedicated to stator inter‐turn short‐circuit fault of an induction machine. This control is based on sliding mode strategy and is implemented for validation on real‐time data acquisition and control platform. The proposed work highlights the integral sliding mode controller benefits during healthy and faulty operations. It can make the induction machine outputs to track their desired reference signals in finite‐time and allows to obtain a better dynamic response performances even in presence of fault. Moreover to avoid the use of a flux sensor, a second order sliding mode observer is used to estimate the rotor flux. Since the used observer converges in finite time, the closed‐loop stability of the proposed system (controller+observer) is proved using the Lyapunov stability theorem. Experimental results are conducted for squirrel cage induction machine to highlight the efficiency and applicability of the proposed fault tolerant control.
- 20 May 2017
- Published by Springer Nature in International Journal of Dynamics and Control
- Vol. 6 (2) , 726-738
Unknown input observer-based active fault tolerant control for induction machine
- 20 May 2017
- Published by Springer Nature in International Journal of Dynamics and Control
- Vol. 6 (2) , 726-738
Unknown input observer-based active fault tolerant control for induction machine
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Observer-based inter-turn short-circuit fault detection in closed-loop controlled induction machine
This paper deals with detecting of stator winding inter-turn short-circuits fault of induction machine operating under two control methods namely the backstepping control and the integral sliding mode control. The fault detection method is introduced, based on analysis of measured three-phase stator currents and estimated ones given by an unknown input observer. The difference between these behaviors, namely residuals, are used to detect the inter-turn short-circuits fault. Simulation results obtained from an induction machine with inter-turn short-circuits fault working under backstepping control and integral sliding mode control are presented.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Observer-based inter-turn short-circuit fault detection in closed-loop controlled induction machine
This paper deals with detecting of stator winding inter-turn short-circuits fault of induction machine operating under two control methods namely the backstepping control and the integral sliding mode control. The fault detection method is introduced, based on analysis of measured three-phase stator currents and estimated ones given by an unknown input observer. The difference between these behaviors, namely residuals, are used to detect the inter-turn short-circuits fault. Simulation results obtained from an induction machine with inter-turn short-circuits fault working under backstepping control and integral sliding mode control are presented.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
High order sliding mode and an unknown input observers: Comparison with integral sliding mode control for induction machine drive
This paper presents a comparison study between high order sliding mode and unknown input observers performances which embedded in an integral sliding mode control scheme for induction machine drive. Both observers purpose is to estimate the machine states. Based on these states, an integral sliding mode controller is designed. The stability of the closed-loop system is shown by using the Lyapunov theory. A comparative simulation results are presented to show the effectiveness of both observers and performance of the controller, in terms of robustness, in low and high speed operation mode, with respect to machine resistances variations and load disturbance.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
High order sliding mode and an unknown input observers: Comparison with integral sliding mode control for induction machine drive
This paper presents a comparison study between high order sliding mode and unknown input observers performances which embedded in an integral sliding mode control scheme for induction machine drive. Both observers purpose is to estimate the machine states. Based on these states, an integral sliding mode controller is designed. The stability of the closed-loop system is shown by using the Lyapunov theory. A comparative simulation results are presented to show the effectiveness of both observers and performance of the controller, in terms of robustness, in low and high speed operation mode, with respect to machine resistances variations and load disturbance.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
High order sliding mode observer for inter-turn short-circuit fault detection in induction machine
This paper explores the design of high order sliding mode observer for induction machine fault detection. Inter-turn short-circuits is one of the most common fault occurring in induction machine. Healthy machine behavior and effects of such fault on the induction machine behavior are evaluated. This motivates the necessity of early fault detection. A high order sliding mode observer is developed and confirmed for different operating conditions. Detection method is based on calculating the difference between the actual behavior of induction machine and the expected behavior given by high order sliding mode observer. That produces a set of residuals sensitive to fault. Numerous simulations results are given to illustrate the effectiveness and performance of the proposed approach.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
High order sliding mode observer for inter-turn short-circuit fault detection in induction machine
This paper explores the design of high order sliding mode observer for induction machine fault detection. Inter-turn short-circuits is one of the most common fault occurring in induction machine. Healthy machine behavior and effects of such fault on the induction machine behavior are evaluated. This motivates the necessity of early fault detection. A high order sliding mode observer is developed and confirmed for different operating conditions. Detection method is based on calculating the difference between the actual behavior of induction machine and the expected behavior given by high order sliding mode observer. That produces a set of residuals sensitive to fault. Numerous simulations results are given to illustrate the effectiveness and performance of the proposed approach.