HSHannes Stadtmann

Hannes Stadtmann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hannes Stadtmann has a total of 158 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • EURADOS IC2019exteye- a self-funded intercomparison for extremity and eye lens dosemeters organised by EURADOS working group 2

    by Andrew McWhan, Wioletta Dobrzynska, Ana Romero, Tom Grimbergen, Hannes Stadtmann, Markus Figel

    The European Radiation Dosimetry Group (EURADOS) has been organising regular, self-funding, external dosimetry intercomparisons (ICs) since 2008. IC2019exteye, for extremity and eye lens dosemeters, attracted 113 systems (68 extremity and 45 eye lens) from 60 institutes with participants from 26 countries around the world. Irradiations were carried out in accredited European irradiation facilities in terms of Hp(0.07)/or Hp(3) in the ranges: photon energy: 16–662 keV, beta mean energy 250–1000 keV, dose: 0.5 mSv to 1 Sv, maximum angle of incidence: ±60°. This paper describes the IC2019exteye set-up, irradiation plan and coordination with an overview of the main conclusions. Out of the total of 113 systems, 57 reported results for photons only and 56 reported both photon and beta. In general, the participants showed very satisfactory performances with the medians of all Hp(0.07) and Hp(3) response values very close to unity.

  • EURADOS intercomparison IC2020ph on whole body dosemeters for photons

    by Argiro Boziari, Hannes Stadtmann, Panagiotis Askounis, Tom Grimbergen, Ana Romero, Andrew McWhan, Markus Figel

    The European Dosimetry Group has been organising international intercomparisons (ICs) for personal dosemeters on a regular basis. The IC announced in 2020 was postponed to the end of 2020 and the beginning of 2021 due to coronavirus (COVID-19) restrictions. The irradiation plan consisted of nine irradiation setups with five different photon radiation qualities (S-Cs, S-Co, N-150, W-60, W-80) and two different angles of irradiation incidence (0o and 60o). A total of 112 monitoring services from 50 countries with 132 dosimetry systems participated. The present work describes and analyses the individual results for the personal dose equivalent quantities Hp(10) and, if submitted, Hp(0.07) for all participating systems. It also presents the organisational details and the difficulties arising from the COVID-19 crisis during the IC. The statistical results showed a satisfactory performance with the medians of all Hp(10) and Hp(0.07) response values very close to unity. However, there are few individual monitoring services with significant large variations.


  • EURADOS whole-body dosemeters intercomparisons: lessons learnt from individual results

    by Ana Maria Romero, Markus Figel, Tom Grimbergen, Andrew McWhan, Hannes Stadtmann

    Every 2 years since 2008, Eurados WG2 has organised a whole-body dosemeters intercomparison (IC) in photon and beta fields. This paper presents the information that individual participants can extract from their results. The irradiation plan of each IC was designed to allow participants check the performance of some important characteristics of their dosimetry systems, in particular: linearity, angular response, energy response and response to mixed fields. The analysis of anomalous responses indicates that many systems can reduce the number of outliers by improving their calibration procedures.

  • EURADOS intercomparisons on whole-body dosemeters for photons from 2008 to 2020: analysis and comparison of general results

    by Hannes Stadtmann, Markus Figel, Tom Grimbergen, Andrew McWhan, Ana Maria Romero

    Starting in 2008 the European Dosimetry Group (EURADOS) has been performing international intercomparisons (ICs) on photon whole-body dosemeters for individual monitoring services. These ICs have been organized (on a biennial basis) starting 2008 up to 2020 now, each time with a similar set-up but with small alterations in the subsequent irradiation plans. The response for Hp(10) and Hp(0.07) was tested for different radiation qualities, angles of incidences (0°–60°) within a wide range of dose values (0.5–500 mSv), to check energy and angular response, linearity, reproducibility and mixed-field response. Within the last 12 years almost 15 000 whole body dosemeters have been irradiated and the corresponding response values evaluated. With an increasing number of participants and participating systems (from 62 to 132), this IC program has become an important tool for individual monitoring services to test their whole-body dosimetry systems, compare their results with other services or systems and to improve the quality of their dosimetry. The paper presents and compares the general results of these seven ICs and analyses the dosimetric results for the participating system types.

  • 25 years of EURADOS working group 2 ‘harmonisation of individual monitoring in Europe’

    by Marie-Anne Chevallier, Oliver Hupe, João Alves, Janwillem van Dijk, David T Bartlett, Elena Fantuzzi, Phil Gilvin, Hannes Stadtmann, Vasiliki Kamenopoulou, Raul M Garcia

    April 2022: The International Conference on Individual Monitoring of Ionising Radiation (IM2022), the first live conference after the COVID pandemic, provided a renewed opportunity to discuss again with colleagues and share new information about individual monitoring, how we solve our common problems by research studies, new methodologies... This desire, this need to share common problems around this theme does not date from yesterday. It was born 25 y ago in Brussels on 28 April 1997, during the first plenary meeting of a concerted EURADOS action called ‘Harmonisation and dosimetric quality assurance in individual monitoring for external radiation’. That event represented the start of a new working group in EURADOS: WG2, which aims to foster harmonisation in individual monitoring for external radiation. EURADOS, in December 1996, set up an Action entitled ‘Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation’. The main objectives of this Action were to assist the consolidation within the EU of the quality of individual monitoring using personal dosemeters and to facilitate harmonised procedures. In order to meet these objectives an Action Group was set up, chaired by David Bartlett (NRPB) and comprising members from each of the EU Member States plus Switzerland. Sub-groups were formed to carry out each of three tasks and prepare a report, assisted by all members of the Action Group. The meetings of the EURADOS Action Group were supported by the European Commission, Directorate General XII, Science Research and Development, under the Nuclear Fission Safety—Reactor Safety, Waste Management and Radiation Protection, Framework Programme (FP) 1994–1998, contract number F14P-CT96-0061


  • A novel approach towards the calculation of dose rate constants for ambient dose equivalent H∗(10) by including low energy x-rays

    by Christoph Stettner, Nadine Baumgartner, Christian Hranitzky, Karin Poljanc, Hannes Stadtmann, Christina Streli


  • Open Access

    EURADOS education and training activities

    by J G Alves, E Fantuzzi, W Rühm, P Gilvin, A Vargas, R Tanner, H Rabus, M A Lopez, B Breustedt, R Harrison, et al.

    This paper provides a summary of the Education and Training (E&T) activities that have been developed and organised by the European Radiation Dosimetry Group (EURADOS) in recent years and in the case of Training Courses over the last decade. These E&T actions include short duration Training Courses on well-established topics organised within the activity of EURADOS Working Groups (WGs), or one-day events integrated in the EURADOS Annual Meeting (workshops, winter schools, the intercomparison participants’ sessions and the learning network, among others). Moreover, EURADOS has recently established a Young Scientist Grant and a Young Scientist Award. The Grant supports young scientists by encouraging them to perform research projects at other laboratories of the EURADOS network. The Award is given in recognition of excellent work developed within the WGs’ work programme. Additionally, EURADOS supports the dissemination of knowledge in radiation dosimetry by promoting and endorsing conferences such as the individual monitoring (IM) series, the neutron and ion dosimetry symposia (NEUDOS) and contributions to E&T sessions at specific events.


  • EURADOS INTERCOMPARISONS ON WHOLE-BODY DOSEMETERS FOR PHOTONS FROM 2008 TO 2014

    by Markus Figel, Hannes Stadtmann, Tom W. M. Grimbergen, Andrew McWhan, Ana M. Romero

    Starting in 2008 the European Dosimetry Group (EURADOS) has been performing international intercomparisons on photon whole-body dosemeters for individual monitoring services. These intercomparisons were organised (on a biannual basis) in 2008, 2010, 2012 and 2014, each time with a similar set-up but with small alterations in the subsequent irradiation plans. With an increasing number of participants and participating systems, this intercomparison action has become an important tool for individual monitoring services to test their whole-body dosimetry systems, compare their results with other services or systems and to improve the quality of their dosimetry. The paper presents and compares the results of these four intercomparisons and compares the dosimetric results for the participating system types. Major dosimetric problems of the individual monitoring services are identified, and trends in the dosimetric performance of the different systems are shown. This gives the opportunity to identify some dosimetry issues that should be improved by application of the monitoring services' quality assurance systems and QA procedures.


  • THE RESULTS OF THE EURADOS INTERCOMPARISON IC2014 FOR WHOLE-BODY DOSEMETERS IN PHOTON FIELDS

    by H. Stadtmann, T. W. M. Grimbergen, M. Figel, A. M. Romero, A. F. McWhan, C. Gärtner

    The European Dosimetry Group (EURADOS) first started performing international intercomparisons for whole-body dosemeters for individual monitoring services in 1998. Since 2008, these whole-body intercomparisons have been performed on a regular basis. In this latest intercomparison (IC2014), 96 monitoring services from 35 countries (mostly European) participated with 112 dosimetry systems. Unlike in the previous intercomparisons, the whole registration, communication and data exchange process was handled by a new on-line platform. All dosemeter irradiations were carried out in the Seibersdorf accredited dosimetry laboratory. The irradiation plan consisted of nine irradiation setups with five different photon radiation qualities (S-Cs, S-Co, RQR7, W-80 and W-150) and two different angles of radiation incidence (0° and 60°). The paper describes and analyses the individual results for the personal dose equivalent quantities Hp(10) and if requested, Hp(0.07), for all participating systems and compares these results with the ISO 14146 ‘trumpet curve’ performance criteria. The results show that 100 systems (89 % of all systems) do fulfil the general ISO 14146 performance criteria. This paper gives an overview on the performance of the participating individual monitoring services and the influence of the dosemeter type on the observed response values.


  • EURADOS PROGRAMME OF INTERCOMPARISONS FOR INDIVIDUAL MONITORING SERVICES: SEVEN YEARS OF DEVELOPMENT AND FUTURE PLANS

    by T. Grimbergen, M. Figel, A. McWhan, A. M. Romero, H. Stadtmann

    In 2008 the European Radiation Dosimetry Group (EURADOS) started a new programme of intercomparisons for individual monitoring services (IMS). The aim was to provide the possibility to IMS in Europe to participate in dosimetry intercomparions with regular time intervals with all types of dosemeter systems that are used routinely to monitor workers for exposure to external radiation. A self-evaluation of the programme shows that, apart from a few problems encountered, the programme can be judged as fit for its purpose. The results of a questionnaire among the participants support this conclusion. The conclusions encourage EURADOS to continue this programme of self-sustained intercomparisons for IMS.