Hongki Yoo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hongki Yoo has a total of 308 co-authors. Here are the top co-authors by number of shared publications:
Hyeong Soo Nam
Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology
33 shared publications- Jin Won Kim
Multimodal Imaging and Theranostic Laboratory, Cardiovascular Center, Korea University Guro Hospital, Seoul, Republic of Korea
27 shared publications Joon Woo Song
Multimodal Imaging and Theranostic Laboratory, Cardiovascular Center, Korea University Guro Hospital, Seoul, Republic of Korea
26 shared publicationsJin Won Kim
Korea University Guro Hospital
22 shared publicationsHyun Jung Kim
Multimodal Imaging and Theranostic Laboratory, Cardiovascular Center, Korea University Guro Hospital, Seoul, Republic of Korea
16 shared publicationsMin Woo Lee
Dotter-Inc., Incheon, Republic of Korea
16 shared publications
Latest Publications
- 12 November 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (45) , 455201
Autofluorescence imaging-based nondestructive monitoring of latent patterns in photolithography
Nondestructive, post-exposure monitoring of latent photoresist patterns remains challenging because conventional metrology relies on post-development inspection, making it difficult to attribute deviations to exposure conditions. We propose an autofluorescence-imaging-based monitoring method that operates immediately after ultraviolet exposure, using excitation wavelengths spectrally separated from the exposure wavelength, and establish its performance as a measurement. To identify a suitable monitoring wavelength, latent patterns were imaged at four excitation wavelengths. Among the wavelengths tested, 561 nm provided the most stable latent-pattern signal, with only a −3.1% change after 30 s of continuous excitation, whereas shorter-wavelength excitation caused unintended additional exposure or substantial photobleaching. The autofluorescence contrast increased nonlinearly with exposure dose and gradually approached saturation, as described by a model derived from depth-integrated photochemical conversion. Inverting the fitted response estimated the delivered dose with 6%–11% RMS error (leave-one-out), and retained sensitivity above the dose to clear, where the developed topography saturated and post-development inspection became insensitive to over-dose. In two independently conducted exposure experiments, no systematic monitoring-induced change in the developed geometry was detected, and the minimum detectable dose was 9.7 mJ cm −2 at 3σ. This label-free approach enables pre-development latent-pattern imaging and quantitative dose monitoring for microscale maskless lithography and process development.
- 12 November 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (45) , 455201
Autofluorescence imaging-based nondestructive monitoring of latent patterns in photolithography
Nondestructive, post-exposure monitoring of latent photoresist patterns remains challenging because conventional metrology relies on post-development inspection, making it difficult to attribute deviations to exposure conditions. We propose an autofluorescence-imaging-based monitoring method that operates immediately after ultraviolet exposure, using excitation wavelengths spectrally separated from the exposure wavelength, and establish its performance as a measurement. To identify a suitable monitoring wavelength, latent patterns were imaged at four excitation wavelengths. Among the wavelengths tested, 561 nm provided the most stable latent-pattern signal, with only a −3.1% change after 30 s of continuous excitation, whereas shorter-wavelength excitation caused unintended additional exposure or substantial photobleaching. The autofluorescence contrast increased nonlinearly with exposure dose and gradually approached saturation, as described by a model derived from depth-integrated photochemical conversion. Inverting the fitted response estimated the delivered dose with 6%–11% RMS error (leave-one-out), and retained sensitivity above the dose to clear, where the developed topography saturated and post-development inspection became insensitive to over-dose. In two independently conducted exposure experiments, no systematic monitoring-induced change in the developed geometry was detected, and the minimum detectable dose was 9.7 mJ cm −2 at 3σ. This label-free approach enables pre-development latent-pattern imaging and quantitative dose monitoring for microscale maskless lithography and process development.
- Open Access
- 16 October 2026
- Published by Springer Nature in Scientific Reports
Multiplexed intravascular molecular imaging using dual-channel near-infrared fluorescence integrated with optical coherence tomography
Accurate characterization of high-risk atherosclerotic plaques requires both structural and molecular information. While integrated optical coherence tomography (OCT)/near-infrared fluorescence (NIRF) imaging enables simultaneous assessment of plaque morphology and biological activity, single-target molecular detection may be insufficient to characterize the multifactorial plaque progression. Multiplexed intravascular molecular imaging remains technically challenging due to fluorescence crosstalk between emission channels, which compromises signal specificity. Here, we present a temporally modulated dual-channel NIRF/OCT catheter system designed to suppress spectral crosstalk and enable simultaneous multiplexed molecular imaging with structural information within the vessel wall. Time-interleaved excitation synchronized to the OCT trigger generates two NIRF excitation signals with a half-cycle phase difference, enabling crosstalk-free detection of two distinct molecular targets, as verified by phantom experiments. In vivo imaging in a rabbit model of atherosclerosis, using probes targeting calcified regions associated with osteogenic activity (ALN-PEG-Cy5.5) and mannose receptor (MMR)-expressing cells, including specific macrophage subset (MMR-PEG-Cy7), enabled simultaneous visualization of distinct molecular signatures within OCT-defined plaque structures. Ex vivo fluorescence imaging and immunohistochemistry supported the biological relevance of each NIRF channel. This integrated multimodal catheter system advances intravascular imaging from single-marker detection toward multiplexed molecular assessment of plaques, which could enable a more comprehensive evaluation of plaque pathobiology.
- 16 October 2026
- Published by Springer Nature in Scientific Reports
Open AccessMultiplexed intravascular molecular imaging using dual-channel near-infrared fluorescence integrated with optical coherence tomography
Accurate characterization of high-risk atherosclerotic plaques requires both structural and molecular information. While integrated optical coherence tomography (OCT)/near-infrared fluorescence (NIRF) imaging enables simultaneous assessment of plaque morphology and biological activity, single-target molecular detection may be insufficient to characterize the multifactorial plaque progression. Multiplexed intravascular molecular imaging remains technically challenging due to fluorescence crosstalk between emission channels, which compromises signal specificity. Here, we present a temporally modulated dual-channel NIRF/OCT catheter system designed to suppress spectral crosstalk and enable simultaneous multiplexed molecular imaging with structural information within the vessel wall. Time-interleaved excitation synchronized to the OCT trigger generates two NIRF excitation signals with a half-cycle phase difference, enabling crosstalk-free detection of two distinct molecular targets, as verified by phantom experiments. In vivo imaging in a rabbit model of atherosclerosis, using probes targeting calcified regions associated with osteogenic activity (ALN-PEG-Cy5.5) and mannose receptor (MMR)-expressing cells, including specific macrophage subset (MMR-PEG-Cy7), enabled simultaneous visualization of distinct molecular signatures within OCT-defined plaque structures. Ex vivo fluorescence imaging and immunohistochemistry supported the biological relevance of each NIRF channel. This integrated multimodal catheter system advances intravascular imaging from single-marker detection toward multiplexed molecular assessment of plaques, which could enable a more comprehensive evaluation of plaque pathobiology.
- 12 October 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (11) , 5638
Introduction to the Advanced Biophotonics feature issue
Biophotonics is an interdisciplinary field at the intersection of photonics, biology, and medicine, driving advances in biomedical imaging, sensing, diagnosis, and therapy. With rapid developments in optical imaging, computational optics, artificial intelligence, nanophotonics, and advanced optical instrumentation, this feature issue highlights recent advances that span fundamental research, enabling technologies, and emerging biomedical applications.
- 12 October 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (11) , 5638
Introduction to the Advanced Biophotonics feature issue
Biophotonics is an interdisciplinary field at the intersection of photonics, biology, and medicine, driving advances in biomedical imaging, sensing, diagnosis, and therapy. With rapid developments in optical imaging, computational optics, artificial intelligence, nanophotonics, and advanced optical instrumentation, this feature issue highlights recent advances that span fundamental research, enabling technologies, and emerging biomedical applications.
- Open Access
- 27 August 2026
- Published by American Physical Society (APS) in Physical Review B
- Vol. 114 (11) , 115418
Eigenstate-selective entangled two-photon absorption in monolayer WSe 2
We show that the Bell-state phase of a polarization-entangled photon pair controls the biexciton eigenstate distribution produced by entangled two-photon absorption in monolayer WSe 2 . In a frequency-nondegenerate ladder scheme, two independent valley pathways ( K and K ′ ) share no intermediate state, so the biphoton phase sets the relative amplitude between them. Within the valley-symmetric limit, the phase dependence is contained in the prefactors 1 ± e i φ , which are independent of the material response. The resulting selection rule partitions the excitation among biexciton eigenstates according to the Bell-state phase φ . The symmetric Bell state ( φ = 0 ) selectively drives bright eigenstates, while the antisymmetric state ( φ = π ) drives the exchange-dark eigenstate. No separable polarization state reproduces this φ -dependent eigenstate distribution. At equal total pair flux, the dark-state pumping rate of the Bell state is twice the upper bound for any separable polarization state. Exceeding this bound certifies polarization entanglement of the source. Including valley dephasing, intervalley scattering, source imperfections, and residual amplitude errors at 4 K, the estimated phase-scan visibility of the eigenstate-resolved pair-absorption rates is V ≳ 0.95 for broadband spontaneous parametric down-conversion (entanglement time T e ∼ 100 fs) with high source concurrence and picosecond-scale valley coherence.
- 27 August 2026
- Published by American Physical Society (APS) in Physical Review B
- Vol. 114 (11) , 115418
Open AccessEigenstate-selective entangled two-photon absorption in monolayer WSe 2
We show that the Bell-state phase of a polarization-entangled photon pair controls the biexciton eigenstate distribution produced by entangled two-photon absorption in monolayer WSe 2 . In a frequency-nondegenerate ladder scheme, two independent valley pathways ( K and K ′ ) share no intermediate state, so the biphoton phase sets the relative amplitude between them. Within the valley-symmetric limit, the phase dependence is contained in the prefactors 1 ± e i φ , which are independent of the material response. The resulting selection rule partitions the excitation among biexciton eigenstates according to the Bell-state phase φ . The symmetric Bell state ( φ = 0 ) selectively drives bright eigenstates, while the antisymmetric state ( φ = π ) drives the exchange-dark eigenstate. No separable polarization state reproduces this φ -dependent eigenstate distribution. At equal total pair flux, the dark-state pumping rate of the Bell state is twice the upper bound for any separable polarization state. Exceeding this bound certifies polarization entanglement of the source. Including valley dephasing, intervalley scattering, source imperfections, and residual amplitude errors at 4 K, the estimated phase-scan visibility of the eigenstate-resolved pair-absorption rates is V ≳ 0.95 for broadband spontaneous parametric down-conversion (entanglement time T e ∼ 100 fs) with high source concurrence and picosecond-scale valley coherence.
- Open Access
- 29 May 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (22) , 220202
Announcing the 2025 measurement science and technology outstanding paper awards
Since 1991, Measurement Science and Technology (MST) has awarded best paper prizes. The Editorial Board of this journal believe that such prizes are an opportunity to thank authors for submitting their work, and serve as an integral part of the ongoing quality review of the journal. The current breadth of topical areas that are covered by MST has made it advisable to expand the recognition of excellent publications. Hence, since 2005 the editorial board have presented ‘Outstanding Paper Awards’. This year awards were given in the areas of fluid mechanics, optical and laser-based techniques, precision measurement, sensors and sensing systems, measurement science, and biological, healthcare and life sciences.
- 29 May 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (22) , 220202
Open AccessAnnouncing the 2025 measurement science and technology outstanding paper awards
Since 1991, Measurement Science and Technology (MST) has awarded best paper prizes. The Editorial Board of this journal believe that such prizes are an opportunity to thank authors for submitting their work, and serve as an integral part of the ongoing quality review of the journal. The current breadth of topical areas that are covered by MST has made it advisable to expand the recognition of excellent publications. Hence, since 2005 the editorial board have presented ‘Outstanding Paper Awards’. This year awards were given in the areas of fluid mechanics, optical and laser-based techniques, precision measurement, sensors and sensing systems, measurement science, and biological, healthcare and life sciences.
- Open Access
- 28 May 2026
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 90 (8) , CJ-26-0020-1032
Lesion-Specific Prediction of Segmental Fractional Flow Reserve Using Deep Learning and Optical Coherence Tomography-Derived Features
Background: Intracoronary imaging-derived physiologic indices enable vessel-level assessment of coronary flow impairment by integrating obstructive plaque burden. However, accurately evaluating hyperemic flow remains challenging due to the difficulty of simultaneously incorporating both vascular geometry and plaque composition.Methods and Results: We aimed to develop and validate a deep learning algorithm using optical coherence tomography (OCT) to predict continuous, lesion-specific changes in fractional flow reserve (∆FFR) along coronary segments. Model performance was evaluated using Pearson’s correlation, a confusion matrix, and a receiver operating characteristic (ROC) curve, with invasive wire-based FFR as the reference. The model was trained and tested on 157 OCT pullbacks from 86 patients, demonstrating enhanced predictive performance by incorporating anatomical and compositional OCT features compared to conventional feature-based machine learning approaches. Predicted ∆FFROCTvalues correlated strongly with wire-based ∆FFR (R=0.932, P<0.001), achieving an accuracy of 0.952 for detecting physiologically significant lesions and an area under the curve of 0.953 in the ROC analysis. The model accurately localized segmental pressure gradients, effectively distinguishing focal from diffuse disease patterns.Conclusions: This novel deep learning-based algorithm enabled lesion-specific, pressure wire-free physiologic assessment from a single OCT pullback. By integrating anatomical and compositional data, it supported improved diagnostic accuracy and personalized treatment for coronary artery disease.
- 28 May 2026
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 90 (8) , CJ-26-0020-1032
Open AccessLesion-Specific Prediction of Segmental Fractional Flow Reserve Using Deep Learning and Optical Coherence Tomography-Derived Features
Background: Intracoronary imaging-derived physiologic indices enable vessel-level assessment of coronary flow impairment by integrating obstructive plaque burden. However, accurately evaluating hyperemic flow remains challenging due to the difficulty of simultaneously incorporating both vascular geometry and plaque composition.Methods and Results: We aimed to develop and validate a deep learning algorithm using optical coherence tomography (OCT) to predict continuous, lesion-specific changes in fractional flow reserve (∆FFR) along coronary segments. Model performance was evaluated using Pearson’s correlation, a confusion matrix, and a receiver operating characteristic (ROC) curve, with invasive wire-based FFR as the reference. The model was trained and tested on 157 OCT pullbacks from 86 patients, demonstrating enhanced predictive performance by incorporating anatomical and compositional OCT features compared to conventional feature-based machine learning approaches. Predicted ∆FFROCTvalues correlated strongly with wire-based ∆FFR (R=0.932, P<0.001), achieving an accuracy of 0.952 for detecting physiologically significant lesions and an area under the curve of 0.953 in the ROC analysis. The model accurately localized segmental pressure gradients, effectively distinguishing focal from diffuse disease patterns.Conclusions: This novel deep learning-based algorithm enabled lesion-specific, pressure wire-free physiologic assessment from a single OCT pullback. By integrating anatomical and compositional data, it supported improved diagnostic accuracy and personalized treatment for coronary artery disease.
- 26 May 2026
- Published by Optica Publishing Group in Photonics Research
- Vol. 14 (6) , 2591
Single-objective two-photon oblique light sheet microscopy with a low repetition rate for 3D high-SNR imaging
Two-photon light sheet microscopy is a powerful technology for rapid three-dimensional (3D) fluorescence imaging with low phototoxicity, which has led to its wide adoption in biomedical and life science applications. However, conventional multiobjective lens configurations limit compatibility with large or irregularly shaped biological samples, restricting broader applicability. Moreover, image quality is often compromised due to the inherent trade-off between the low numerical aperture required for selective planar illumination and the reduced efficiency of two-photon excitation. In this study, we present a single-objective two-photon oblique light sheet microscopy (TP-ob-LSM) system employing a low-repetition-rate light source. This single-objective lens design enables simultaneous excitation and detection, thereby significantly enhancing compatibility with diverse biological sample geometries. Furthermore, by adjusting the repetition rate while maintaining constant average power, we increased pulse energy and achieved a 22.9-fold improvement in signal-to-noise ratio compared to conventional high-repetition-rate systems through system-level optimization of the excitation regime. We demonstrate large-volume reconstructions (9 mm ×6 mm ×0.18 mm ) and deep-tissue imaging in 1-mm-thick mouse brain slices with clear dendritic morphology. The proposed TP-ob-LSM with low-repetition-rate excitation offers a promising solution for high-quality 3D imaging across a wide range of biomedical applications.
- 26 May 2026
- Published by Optica Publishing Group in Photonics Research
- Vol. 14 (6) , 2591
Single-objective two-photon oblique light sheet microscopy with a low repetition rate for 3D high-SNR imaging
Two-photon light sheet microscopy is a powerful technology for rapid three-dimensional (3D) fluorescence imaging with low phototoxicity, which has led to its wide adoption in biomedical and life science applications. However, conventional multiobjective lens configurations limit compatibility with large or irregularly shaped biological samples, restricting broader applicability. Moreover, image quality is often compromised due to the inherent trade-off between the low numerical aperture required for selective planar illumination and the reduced efficiency of two-photon excitation. In this study, we present a single-objective two-photon oblique light sheet microscopy (TP-ob-LSM) system employing a low-repetition-rate light source. This single-objective lens design enables simultaneous excitation and detection, thereby significantly enhancing compatibility with diverse biological sample geometries. Furthermore, by adjusting the repetition rate while maintaining constant average power, we increased pulse energy and achieved a 22.9-fold improvement in signal-to-noise ratio compared to conventional high-repetition-rate systems through system-level optimization of the excitation regime. We demonstrate large-volume reconstructions (9 mm ×6 mm ×0.18 mm ) and deep-tissue imaging in 1-mm-thick mouse brain slices with clear dendritic morphology. The proposed TP-ob-LSM with low-repetition-rate excitation offers a promising solution for high-quality 3D imaging across a wide range of biomedical applications.
- 12 May 2026
- Published by Elsevier in Precision Engineering
- Vol. 101, 357-371
Impact of encoder-head installation errors and geometrical scale errors on angle self-calibration accuracy using four arbitrarily arranged encoder-heads
- 12 May 2026
- Published by Elsevier in Precision Engineering
- Vol. 101, 357-371
Impact of encoder-head installation errors and geometrical scale errors on angle self-calibration accuracy using four arbitrarily arranged encoder-heads
- Open Access
- 18 April 2026
- Published by Springer Nature in Biomedical Engineering Letters
- p. 1-14
Optical coherence tomography for broad spectrum of thyroid carcinoma: a qualitative and quantitative analysis
Optical coherence tomography (OCT) is a non-invasive imaging modality providing real-time micrometer-scale resolution without conventional tissue processing. This study evaluated the diagnostic potential of OCT for distinguishing normal thyroid tissue from a broad spectrum of thyroid carcinomas in a pathological context. OCT imaging was performed on formalin-fixed thyroid specimens from 41 cases, including papillary (PTC, n = 11), follicular (FTC, n = 6), oncocytic (OCA, n = 3), anaplastic (ATC, n = 9), and medullary thyroid carcinoma (MTC, n = 12), with corresponding hematoxylin and eosin sections for correlation. Quantitative parameters were developed or adopted, including surface irregularity, penetration depth, tissue brightness, and gray-level co-occurrence matrix texture features. Qualitative analysis demonstrated visualization of tumor-specific architectural patterns, while three-dimensional reconstruction enabled depth-resolved assessment of capsular invasion and peri-capsular vascular structures. All quantitative metrics significantly differentiated carcinoma from normal tissue and showed discriminative capability across carcinoma subtypes. These findings highlight OCT as a high-resolution, label-free modality with utility in thyroid cancer diagnosis.
- 18 April 2026
- Published by Springer Nature in Biomedical Engineering Letters
- p. 1-14
Open AccessOptical coherence tomography for broad spectrum of thyroid carcinoma: a qualitative and quantitative analysis
Optical coherence tomography (OCT) is a non-invasive imaging modality providing real-time micrometer-scale resolution without conventional tissue processing. This study evaluated the diagnostic potential of OCT for distinguishing normal thyroid tissue from a broad spectrum of thyroid carcinomas in a pathological context. OCT imaging was performed on formalin-fixed thyroid specimens from 41 cases, including papillary (PTC, n = 11), follicular (FTC, n = 6), oncocytic (OCA, n = 3), anaplastic (ATC, n = 9), and medullary thyroid carcinoma (MTC, n = 12), with corresponding hematoxylin and eosin sections for correlation. Quantitative parameters were developed or adopted, including surface irregularity, penetration depth, tissue brightness, and gray-level co-occurrence matrix texture features. Qualitative analysis demonstrated visualization of tumor-specific architectural patterns, while three-dimensional reconstruction enabled depth-resolved assessment of capsular invasion and peri-capsular vascular structures. All quantitative metrics significantly differentiated carcinoma from normal tissue and showed discriminative capability across carcinoma subtypes. These findings highlight OCT as a high-resolution, label-free modality with utility in thyroid cancer diagnosis.
- 15 April 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (5) , 2428-2441
Label-free diagnosis across the thyroid nodule pathology spectrum using deep learning-enabled optical coherence tomography
Thyroid nodules are highly prevalent, yet identifying malignancy remains a persistent challenge due to their significant pathological heterogeneity. Conventional diagnostic workflows rely on invasive and tissue-destructive sampling followed by a time-consuming histopathology tissue process, restricting the ability to obtain pathological insights in real-time or at the bedside. In this context, optical coherence tomography (OCT) has gained attention as a non-invasive, label-free imaging modality; however, its interpretation for detailed pathological assessment has remained challenging. Here, we developed a deep learning (DL)-based framework for diagnostic classification across the spectrum of thyroid nodule pathology using OCT images. OCT datasets were acquired from seven pathological categories, including five thyroid carcinoma subtypes as well as two non-carcinoma tissue types (benign and normal), and were matched with histology for supervised learning. Robust binary differentiation between carcinoma and non-carcinoma was achieved, with an accuracy of 98.37% and an area under the receiver operating characteristic curve of 0.997. Furthermore, multi-class classification across seven pathological categories further demonstrated an overall accuracy of 93.66% on held-out test sets. Diagnostic predictions were visualized as color-coded overlays on e n face OCT images, enabling coherent interpretation across tissue volumes. These results demonstrate the feasibility of combining OCT with DL for enhanced thyroid pathology assessment and motivate further optimization toward real-time and point-of-care diagnostic deployment.
- 15 April 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (5) , 2428-2441
Label-free diagnosis across the thyroid nodule pathology spectrum using deep learning-enabled optical coherence tomography
Thyroid nodules are highly prevalent, yet identifying malignancy remains a persistent challenge due to their significant pathological heterogeneity. Conventional diagnostic workflows rely on invasive and tissue-destructive sampling followed by a time-consuming histopathology tissue process, restricting the ability to obtain pathological insights in real-time or at the bedside. In this context, optical coherence tomography (OCT) has gained attention as a non-invasive, label-free imaging modality; however, its interpretation for detailed pathological assessment has remained challenging. Here, we developed a deep learning (DL)-based framework for diagnostic classification across the spectrum of thyroid nodule pathology using OCT images. OCT datasets were acquired from seven pathological categories, including five thyroid carcinoma subtypes as well as two non-carcinoma tissue types (benign and normal), and were matched with histology for supervised learning. Robust binary differentiation between carcinoma and non-carcinoma was achieved, with an accuracy of 98.37% and an area under the receiver operating characteristic curve of 0.997. Furthermore, multi-class classification across seven pathological categories further demonstrated an overall accuracy of 93.66% on held-out test sets. Diagnostic predictions were visualized as color-coded overlays on e n face OCT images, enabling coherent interpretation across tissue volumes. These results demonstrate the feasibility of combining OCT with DL for enhanced thyroid pathology assessment and motivate further optimization toward real-time and point-of-care diagnostic deployment.