Wei Yao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Wei Yao has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Kamal Deep
Golden Jubilee National Hospital, Glasgow, UK
4 shared publicationsAhmad Nazmi Bin Ahmad Fuad
The Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
3 shared publicationsHariprashanth Elangovan
University of Strathclyde, Glasgow, Scotland, UK
3 shared publicationsJun Xie
Department of Mechanical Engineering, Xian Jiaotong University, Xian, China
3 shared publications- Min Li
School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China
3 shared publications - Bo He
Xi’an Jiaotong University
2 shared publications
Latest Publications
- 27 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (6) , 5606-5615
Optoelectronic-Based Pose Sensing for a Hand Rehabilitation Exoskeleton Continuous Structure
Hand exoskeleton pose monitoring is of great importance in the rehabilitation training of stroke patients to ensure precise robotic trajectory control and provide a patient recovery assessment mechanism. In this paper, a low-cost pose sensor unit based on the principle of photoelectric reflection is proposed to measure the pose of a multi-segment continuous structure in a hand rehabilitation exoskeleton. The sensor unit consists of five photosensitive elements that measure the rotation angle of an arrangement of adjacent segments, each integrated with a sensing element, to estimate the actuator’s motion. An accurate device with a user-friendly interface is then designed for calibration of the sensing elements. The experimental results indicate that the sensitivity exceeds 0.047 V/° for the sensing elements, and hysteresis and repeatability errors are less than 1.1% and 1.8%, respectively. A comparison between the proposed sensor output and the results benchmarked by a VICON motion capture system demonstrates that the sensor can measure the bending angle of the multi-segment structure with a mean error of 3.23 degrees.
- 27 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (6) , 5606-5615
Optoelectronic-Based Pose Sensing for a Hand Rehabilitation Exoskeleton Continuous Structure
Hand exoskeleton pose monitoring is of great importance in the rehabilitation training of stroke patients to ensure precise robotic trajectory control and provide a patient recovery assessment mechanism. In this paper, a low-cost pose sensor unit based on the principle of photoelectric reflection is proposed to measure the pose of a multi-segment continuous structure in a hand rehabilitation exoskeleton. The sensor unit consists of five photosensitive elements that measure the rotation angle of an arrangement of adjacent segments, each integrated with a sensing element, to estimate the actuator’s motion. An accurate device with a user-friendly interface is then designed for calibration of the sensing elements. The experimental results indicate that the sensitivity exceeds 0.047 V/° for the sensing elements, and hysteresis and repeatability errors are less than 1.1% and 1.8%, respectively. A comparison between the proposed sensor output and the results benchmarked by a VICON motion capture system demonstrates that the sensor can measure the bending angle of the multi-segment structure with a mean error of 3.23 degrees.
- Open Access
- 1 January 2022
- Published by Journal of Lake Sciences in Journal of Lake Sciences
- Vol. 34 (4) , 1164-1174
Effects of soaking Eucalyptus leaves on melanogenic elements distribution, migration and transformation in reservoir sediments of Southern China
- 1 January 2022
- Published by Journal of Lake Sciences in Journal of Lake Sciences
- Vol. 34 (4) , 1164-1174
Open AccessEffects of soaking Eucalyptus leaves on melanogenic elements distribution, migration and transformation in reservoir sediments of Southern China
- 2 December 2021
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 106 (1) , 103731
Corrigendum to Formation of Microcapsules by Ultrasound Stimulation for Use in Remote-controlled Drug-eluting Stents
- 2 December 2021
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 106 (1) , 103731
Corrigendum to Formation of Microcapsules by Ultrasound Stimulation for Use in Remote-controlled Drug-eluting Stents
- 30 October 2020
- Published by Taylor & Francis in Advanced Robotics
- Vol. 35 (7) , 400-412
A wearable fiber-optic sensor for monitoring human elbow and wrist joint motion
This article describes a wearable sensor for monitoring the motion of human elbow and wrist joints. The sensor converts the joint motion angle into a displacement, which is monitored using a fiber-optic sensor based on reflective light intensity modulation. A mathematical model is established, and the potential influencing factors of the sensor are investigated. Two prototypes for elbow and wrist joint angle monitoring are fabricated and validated. The experimental results indicate that the proposed sensor has a measurement range of 0–60° (0–120°), with a resolution of 0.338° (3.6°) for monitoring the wrist joint palm flexion (elbow joint flexion). The proposed sensor has the potential to be used for rehabilitation purposes and monitoring of joint angles while performing reaching tasks, which are the most common upper-limb gestures. GRAPHICAL ABSTRACT
- 30 October 2020
- Published by Taylor & Francis in Advanced Robotics
- Vol. 35 (7) , 400-412
A wearable fiber-optic sensor for monitoring human elbow and wrist joint motion
This article describes a wearable sensor for monitoring the motion of human elbow and wrist joints. The sensor converts the joint motion angle into a displacement, which is monitored using a fiber-optic sensor based on reflective light intensity modulation. A mathematical model is established, and the potential influencing factors of the sensor are investigated. Two prototypes for elbow and wrist joint angle monitoring are fabricated and validated. The experimental results indicate that the proposed sensor has a measurement range of 0–60° (0–120°), with a resolution of 0.338° (3.6°) for monitoring the wrist joint palm flexion (elbow joint flexion). The proposed sensor has the potential to be used for rehabilitation purposes and monitoring of joint angles while performing reaching tasks, which are the most common upper-limb gestures. GRAPHICAL ABSTRACT
- 11 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (15) , 6497-6507
Attention-Controlled Assistive Wrist Rehabilitation Using a Low-Cost EEG Sensor
It is essential to make sure patients be actively involved in motor training using robot-assisted rehabilitation to achieve better rehabilitation outcomes. This paper introduces an attention-controlled wrist rehabilitation method using a low-cost EEG sensor. Active rehabilitation training is realized using a threshold of the attention level measured by the low-cost EEG sensor as a switch for a flexible wrist exoskeleton assisting wrist flexion/extension and radial/ulnar deviation. We present a prototype implementation of this active training method and provide a preliminary evaluation. The feasibility of the attention-based control was proven with the overall actuation success rate of 95%. The experimental results also proved that the visual guidance was helpful for the users to concentrate on the wrist rehabilitation training: two types of visual guidance, namely, looking at the hand motion shown on a video and looking at the user’s own hand had no significant performance difference. A general threshold of a certain group of users can be utilized in the wrist robot control rather than a customized threshold to simplify the procedure.
- 11 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (15) , 6497-6507
Attention-Controlled Assistive Wrist Rehabilitation Using a Low-Cost EEG Sensor
It is essential to make sure patients be actively involved in motor training using robot-assisted rehabilitation to achieve better rehabilitation outcomes. This paper introduces an attention-controlled wrist rehabilitation method using a low-cost EEG sensor. Active rehabilitation training is realized using a threshold of the attention level measured by the low-cost EEG sensor as a switch for a flexible wrist exoskeleton assisting wrist flexion/extension and radial/ulnar deviation. We present a prototype implementation of this active training method and provide a preliminary evaluation. The feasibility of the attention-based control was proven with the overall actuation success rate of 95%. The experimental results also proved that the visual guidance was helpful for the users to concentrate on the wrist rehabilitation training: two types of visual guidance, namely, looking at the hand motion shown on a video and looking at the user’s own hand had no significant performance difference. A general threshold of a certain group of users can be utilized in the wrist robot control rather than a customized threshold to simplify the procedure.
- Open Access
- 6 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Robotic-Assisted 3D Bio-printing for Repairing Bone and Cartilage Defects through a Minimally Invasive Approach
There is an unmet need for new techniques and methods of healing critical size tissue defects, by further reduction of invasiveness in implant, cell and tissue-based surgery. This paper presents the development of a new regenerative medicine that combines 3D bio-printing and robotic-assisted minimally invasive surgery techniques to meet this need. We investigated the feasibility of Remote Centre of Motion (RCM) and viscous material extrusion 3D printing. A hypothetical, intra-articular, regenerative medicine-based treatment technique for focal cartilage defects of the knee was used as a potential example of the application of 3D printing in vivo. The results of this study suggest, that RCM mechanism is feasible with viscous material extrusion 3D printing processes, without a major trade-off in imprint quality. The achieved printing accuracy at an average dimensional error of 0.06 ± 0.14 mm in this new modality of 3D printing is comparable to those described in literature for other types of bio-printing. Robotic assisted 3D bio-printing demonstrated here is a viable option for focal cartilage defect restoration.
- 6 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Open AccessRobotic-Assisted 3D Bio-printing for Repairing Bone and Cartilage Defects through a Minimally Invasive Approach
There is an unmet need for new techniques and methods of healing critical size tissue defects, by further reduction of invasiveness in implant, cell and tissue-based surgery. This paper presents the development of a new regenerative medicine that combines 3D bio-printing and robotic-assisted minimally invasive surgery techniques to meet this need. We investigated the feasibility of Remote Centre of Motion (RCM) and viscous material extrusion 3D printing. A hypothetical, intra-articular, regenerative medicine-based treatment technique for focal cartilage defects of the knee was used as a potential example of the application of 3D printing in vivo. The results of this study suggest, that RCM mechanism is feasible with viscous material extrusion 3D printing processes, without a major trade-off in imprint quality. The achieved printing accuracy at an average dimensional error of 0.06 ± 0.14 mm in this new modality of 3D printing is comparable to those described in literature for other types of bio-printing. Robotic assisted 3D bio-printing demonstrated here is a viable option for focal cartilage defect restoration.
- 28 November 2018
- Published by SAGE Publications in Surgical Innovation
- Vol. 26 (1) , 27-36
A Multimodality Navigation System for Endoscopic Fetal Surgery: A Phantom Case Study for Congenital Diaphragmatic Hernia
This article presents a multi-modality tracking and navigation system achieved by merging optical tracking and ultrasound imaging into a novel navigation software to help in surgical pre-planning and real-time target setting and guidance. Fetal surgeries require extensive experience in coordination of hand-eye-ultrasound-surgical equipment, knowledge, and precise assessment of relative anatomy. While there are navigation systems available for similar constrained working spaces in arthroscopic and cardiovascular procedures, fetal minimally invasive surgery does not yet have a dedicated navigation platform capable of supporting robotic instruments that can be adapted to the set of unique procedures. This article discusses the testing of the novel multi-modality navigation system in a phantom environment developed for this purpose. The outcomes suggest that the subjects demonstrated an increase in average reaching accuracy by about 60% and an overall reduction in time taken by 33.6%. They also showed higher levels of confidence in reaching the targets, which was visualised from the pattern of trajectory of movements during the procedure. To evaluate the navigation system, a phantom surgical environment was found necessary. Therefore, the article also discusses the details of the development of a fetal phantom environment for congenital diaphragmatic hernia for surgical testing, evaluation, and training. A surgical procedure was conducted on the phantom using the proposed tracking navigation system and using only ultrasound.
- 28 November 2018
- Published by SAGE Publications in Surgical Innovation
- Vol. 26 (1) , 27-36
A Multimodality Navigation System for Endoscopic Fetal Surgery: A Phantom Case Study for Congenital Diaphragmatic Hernia
This article presents a multi-modality tracking and navigation system achieved by merging optical tracking and ultrasound imaging into a novel navigation software to help in surgical pre-planning and real-time target setting and guidance. Fetal surgeries require extensive experience in coordination of hand-eye-ultrasound-surgical equipment, knowledge, and precise assessment of relative anatomy. While there are navigation systems available for similar constrained working spaces in arthroscopic and cardiovascular procedures, fetal minimally invasive surgery does not yet have a dedicated navigation platform capable of supporting robotic instruments that can be adapted to the set of unique procedures. This article discusses the testing of the novel multi-modality navigation system in a phantom environment developed for this purpose. The outcomes suggest that the subjects demonstrated an increase in average reaching accuracy by about 60% and an overall reduction in time taken by 33.6%. They also showed higher levels of confidence in reaching the targets, which was visualised from the pattern of trajectory of movements during the procedure. To evaluate the navigation system, a phantom surgical environment was found necessary. Therefore, the article also discusses the details of the development of a fetal phantom environment for congenital diaphragmatic hernia for surgical testing, evaluation, and training. A surgical procedure was conducted on the phantom using the proposed tracking navigation system and using only ultrasound.
- 1 September 2018
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 46, 231-237
Feasibility study on a robot-assisted procedure for tumor localization using needle-rotation force signals
- 1 September 2018
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 46, 231-237
Feasibility study on a robot-assisted procedure for tumor localization using needle-rotation force signals
- Open Access
- 19 August 2018
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 2018, 1-2
Biomechanics and Bioengineering of Orthopedic and Cardiovascular Rehabilitation
- 19 August 2018
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 2018, 1-2
Open AccessBiomechanics and Bioengineering of Orthopedic and Cardiovascular Rehabilitation
- 18 April 2018
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 56 (1) , 42-47
Formation of microcapsules by ultrasound stimulation for use in remote-controlled drug-eluting stents
Coronary Heart Disease (CHD) is the leading cause of death globally. The placement of drug-eluting stents (DESs) in diseased coronary arteries is the most successful minimally-invasive intervention to treat CHD. The key limitations of such interventional therapy are the risk of in-stent restenosis (ISR) and late stent thrombosis. This paper investigates a new drug-release system by formatting nanoparticles as drug carriers, which are later subjected to an external ultrasonic stimulus for controlled drug release remotely for DESs. The drug delivery could delay smooth muscle cell growth whilst enabling effective regeneration of a functional endothelium. Microcapsules were produced by employing a layer-by-layer technique, encapsulated with Rhodamine 6G dye used in place of anti-restenotic drugs. Gold nanoparticles were employed as a shell in the microcapsules. The presence of gold nanoparticles significantly enhanced the efficiency of the ultrasonically induced dye release from the microcapsules and increased the sensitivity of the microcapsules to ultrasonic stimulation compared to those without gold nanoparticles.
- 18 April 2018
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 56 (1) , 42-47
Formation of microcapsules by ultrasound stimulation for use in remote-controlled drug-eluting stents
Coronary Heart Disease (CHD) is the leading cause of death globally. The placement of drug-eluting stents (DESs) in diseased coronary arteries is the most successful minimally-invasive intervention to treat CHD. The key limitations of such interventional therapy are the risk of in-stent restenosis (ISR) and late stent thrombosis. This paper investigates a new drug-release system by formatting nanoparticles as drug carriers, which are later subjected to an external ultrasonic stimulus for controlled drug release remotely for DESs. The drug delivery could delay smooth muscle cell growth whilst enabling effective regeneration of a functional endothelium. Microcapsules were produced by employing a layer-by-layer technique, encapsulated with Rhodamine 6G dye used in place of anti-restenotic drugs. Gold nanoparticles were employed as a shell in the microcapsules. The presence of gold nanoparticles significantly enhanced the efficiency of the ultrasonically induced dye release from the microcapsules and increased the sensitivity of the microcapsules to ultrasonic stimulation compared to those without gold nanoparticles.