Yichi Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yichi Zhang has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Zhao He
Natl Inst Metrol NIM, Beijing 100029, Peoples R China
9 shared publicationsJianming Huang
National Institute of Metrology (NIM), Beijing, China
6 shared publicationsLifeng Wang
Natl Inst Metrol NIM, Beijing 100029, Peoples R China
6 shared publicationsXiaotao Guo
Natl Inst Metrol NIM, Beijing 100029, Peoples R China
6 shared publicationsMeining Nie
Natl Inst Metrol NIM, Beijing 100029, Peoples R China
5 shared publicationsMaoliu Lin
Department of Electronic and Telecommunication Engineering, Harbin Institute of Technology, Harbin, China
4 shared publications
Latest Publications
- 9 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 73 (4) , 2271-2280
Evaluating EVM Performance in Millimeter-Wave OTA Test Using Digitally Modulated Stimuli With Pre-Distortion and a NVNA Test Bench
In this paper, we present a frequency-domain measurement setup for millimeter-wave over-the-air (OTA) test, which uses digitally modulated stimuli to evaluate the error vector magnitude (EVM) performance of antennas. The proposed nonlinear vector network analyzer (NVNA) like test bench sweepingly measures the magnitude and phase spectra of 64-QAM transmit/receive (TX/RX) signals, and derives the EVMs from reconstructed waveforms based on calibrated measurements in the frequency domain. Pre-distortion is also performed to compensate the distortion arising from 64-QAM generation and up-conversion, so that low-EVM test stimuli can be used to inspect the antenna performance under on- and off-axis scenarios. The validity of proposed NVNA setup is experimentally verified at 28 and 39 GHz, where typical EVMs of 100-MSymbol/s 64-QAM test signals are less than 0.3% for pre-distorted TX measurements, and from 1.03% to 5.68% for RX results under different positioning situations.
- 9 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 73 (4) , 2271-2280
Evaluating EVM Performance in Millimeter-Wave OTA Test Using Digitally Modulated Stimuli With Pre-Distortion and a NVNA Test Bench
In this paper, we present a frequency-domain measurement setup for millimeter-wave over-the-air (OTA) test, which uses digitally modulated stimuli to evaluate the error vector magnitude (EVM) performance of antennas. The proposed nonlinear vector network analyzer (NVNA) like test bench sweepingly measures the magnitude and phase spectra of 64-QAM transmit/receive (TX/RX) signals, and derives the EVMs from reconstructed waveforms based on calibrated measurements in the frequency domain. Pre-distortion is also performed to compensate the distortion arising from 64-QAM generation and up-conversion, so that low-EVM test stimuli can be used to inspect the antenna performance under on- and off-axis scenarios. The validity of proposed NVNA setup is experimentally verified at 28 and 39 GHz, where typical EVMs of 100-MSymbol/s 64-QAM test signals are less than 0.3% for pre-distorted TX measurements, and from 1.03% to 5.68% for RX results under different positioning situations.
- 11 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 71 (10) , 4459-4470
Verification of Real-Time Oscilloscope for Millimeter-Wave Modulated-Signal Measurements Using an NVNA Test Bench
In this article, a nonlinear vector network analyzer (NVNA)-like measurement setup is developed to characterize millimeter-wave digitally modulated signals with low error vector magnitude (EVM) in the frequency domain, which is later used to verify the performance of a commercial high-speed real-time oscilloscope (RTO) for vector signal analysis. To accomplish that, a frequency-domain predistortion method is used to lower the EVMs of 64-state quadrature amplitude modulation (64-QAM) test targets with carrier frequencies from 20 to 42 GHz and symbol rates from 0.1 to 1 GSymbol/s. According to the method validation typically at 28 GHz with a symbol rate of 0.5 GSymbol/s, the proposed NVNA setup can derive the low-EVM measurements of 0.29% with an upper 95% confidence bound of 0.85%. The RTO measurement of the same signal is up to 2.02%, which is codetermined by the in-band RTO responses and an EVM floor of 1.47%.
- 11 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 71 (10) , 4459-4470
Verification of Real-Time Oscilloscope for Millimeter-Wave Modulated-Signal Measurements Using an NVNA Test Bench
In this article, a nonlinear vector network analyzer (NVNA)-like measurement setup is developed to characterize millimeter-wave digitally modulated signals with low error vector magnitude (EVM) in the frequency domain, which is later used to verify the performance of a commercial high-speed real-time oscilloscope (RTO) for vector signal analysis. To accomplish that, a frequency-domain predistortion method is used to lower the EVMs of 64-state quadrature amplitude modulation (64-QAM) test targets with carrier frequencies from 20 to 42 GHz and symbol rates from 0.1 to 1 GSymbol/s. According to the method validation typically at 28 GHz with a symbol rate of 0.5 GSymbol/s, the proposed NVNA setup can derive the low-EVM measurements of 0.29% with an upper 95% confidence bound of 0.85%. The RTO measurement of the same signal is up to 2.02%, which is codetermined by the in-band RTO responses and an EVM floor of 1.47%.
- 12 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 71 (1) , 250-262
Characterization of Millimeter-Wave Wideband FMCW Signals Based on a Precisely Synchronized NVNA for Automotive Radar Applications
In this article, a nonlinear vector network analyzer (NVNA) measurement setup is developed to characterize frequency modulated continuous wave (FMCW) signals in the frequency domain. Thanks to the use of precisely synchronized multisine phase reference and pulsed-RF phase calibration standards, such NVNA setup is validated for high-accuracy measurement of wideband FMCW signals at the millimeter-wave test bands. According to the method validation at 24 and 60 GHz with a maximum FMCW bandwidth of 2 GHz, the proposed NVNA setup has lower measurement errors and uncertainties than the commercial real-time oscilloscope (RTO) and vector signal analyzer (VSA), offering a reference standard of test and calibration for automotive radar applications.
- 12 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 71 (1) , 250-262
Characterization of Millimeter-Wave Wideband FMCW Signals Based on a Precisely Synchronized NVNA for Automotive Radar Applications
In this article, a nonlinear vector network analyzer (NVNA) measurement setup is developed to characterize frequency modulated continuous wave (FMCW) signals in the frequency domain. Thanks to the use of precisely synchronized multisine phase reference and pulsed-RF phase calibration standards, such NVNA setup is validated for high-accuracy measurement of wideband FMCW signals at the millimeter-wave test bands. According to the method validation at 24 and 60 GHz with a maximum FMCW bandwidth of 2 GHz, the proposed NVNA setup has lower measurement errors and uncertainties than the commercial real-time oscilloscope (RTO) and vector signal analyzer (VSA), offering a reference standard of test and calibration for automotive radar applications.
- 24 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 69 (11) , 7231-7242
NVNA Test Bench for Characterizing In-Band Full-Duplex Performance of Millimeter-Wave Antennas
In this article, we present a novel nonlinear vector network analyzer (NVNA) setup for charactering the in-band full-duplex (IBFD) performance of millimeter-wave antenna systems. To achieve millimeter-wave modulated measurements on dense spectral grids, this NVNA setup utilizes user-defined: 1) digitally-modulated test stimuli; 2) multisine phase reference; and 3) pulsed-radio frequency (RF) phase calibration standards for test bench establishment and calibration. To create the IBFD test scenario, a special design of test stimuli is developed for antenna characterization, where the spectral components of two periodical transmitting signals (digitally modulated within the same frequency band) do not overlap with each other. In this way, the desired magnitude and phase information of transmitted and received signals can be easily separated and extracted from the NVNA measurements, to support various frequency-, time-, and digital-domain analysis. The validity of the proposed NVNA setup is experimentally verified at 28 GHz, where the error vector magnitude (EVM) results of 100 MSymbol/s 64-QAM test signals are from 2.0% to 2.3%. From the application perspective, this measurement setup and test method can be widely used for fifth-generation (5G)-oriented over-the-air test of IBFD antenna systems.
- 24 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 69 (11) , 7231-7242
NVNA Test Bench for Characterizing In-Band Full-Duplex Performance of Millimeter-Wave Antennas
In this article, we present a novel nonlinear vector network analyzer (NVNA) setup for charactering the in-band full-duplex (IBFD) performance of millimeter-wave antenna systems. To achieve millimeter-wave modulated measurements on dense spectral grids, this NVNA setup utilizes user-defined: 1) digitally-modulated test stimuli; 2) multisine phase reference; and 3) pulsed-radio frequency (RF) phase calibration standards for test bench establishment and calibration. To create the IBFD test scenario, a special design of test stimuli is developed for antenna characterization, where the spectral components of two periodical transmitting signals (digitally modulated within the same frequency band) do not overlap with each other. In this way, the desired magnitude and phase information of transmitted and received signals can be easily separated and extracted from the NVNA measurements, to support various frequency-, time-, and digital-domain analysis. The validity of the proposed NVNA setup is experimentally verified at 28 GHz, where the error vector magnitude (EVM) results of 100 MSymbol/s 64-QAM test signals are from 2.0% to 2.3%. From the application perspective, this measurement setup and test method can be widely used for fifth-generation (5G)-oriented over-the-air test of IBFD antenna systems.
- 6 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
Repeatable Phase Spectrum Measurements of 75–110-GHz Modulated Signals Using a VNA-Based LO Phase Cancellation Technique
In this article, we present a vector network analyzer (VNA)-based measurement scheme and setup to obtain repeatable phase spectrum measurements of 75–110-GHz modulated radio frequency (RF) signals. In order to remove the random phase contribution of sweeping local oscillator (LO) in harmonic downconversion, the LO signal is coupled out into an auxiliary measurement channel where its random phase at the fundamental can be derived after additional modulation and downconversion treatments. Afterward, a user-defined math equation is used inside the VNA for LO phase cancellation, based on the traces of RF- and auxiliary-channel raw measurements. The key point of the proposed LO phase cancellation technique is measuring the 75–110-GHz test signal and the auxiliary-channel signal at the same GHz intermediate frequency so that the receivers of VNA can measure both of them simultaneously when working on the peculiar continuous-wave or zero-span mode. According to the method validation at 78, 93, and 108 GHz, a phase fluctuation of ±2° for single-run measurements is found reachable in practice.
- 6 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
Repeatable Phase Spectrum Measurements of 75–110-GHz Modulated Signals Using a VNA-Based LO Phase Cancellation Technique
In this article, we present a vector network analyzer (VNA)-based measurement scheme and setup to obtain repeatable phase spectrum measurements of 75–110-GHz modulated radio frequency (RF) signals. In order to remove the random phase contribution of sweeping local oscillator (LO) in harmonic downconversion, the LO signal is coupled out into an auxiliary measurement channel where its random phase at the fundamental can be derived after additional modulation and downconversion treatments. Afterward, a user-defined math equation is used inside the VNA for LO phase cancellation, based on the traces of RF- and auxiliary-channel raw measurements. The key point of the proposed LO phase cancellation technique is measuring the 75–110-GHz test signal and the auxiliary-channel signal at the same GHz intermediate frequency so that the receivers of VNA can measure both of them simultaneously when working on the peculiar continuous-wave or zero-span mode. According to the method validation at 78, 93, and 108 GHz, a phase fluctuation of ±2° for single-run measurements is found reachable in practice.
- Open Access
- 31 December 2020
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 9 (5) , 129-132
Performance test of cantilever transfer standard used for afm tip calibration based on electromagnetic compensation
This paper describes stiffness measurement of cantilever transfer standards used for Atomic Force Microscopy (AFM) tip calibration based on electromagnetic compensation. The transfer standard of cantilever is designed and manufactured based on the bulk fabrication of SOI wafers. The measure range of the transfer standard covers from 0.04 N/m to 16 N/m. The series of transfer standard is designed for the calibration test of the cantilever used in AFM, along with the test apparatus specifically designed. The relative uncertainty of the stiffness is smaller than 2.4 % (k = 2).
- 31 December 2020
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 9 (5) , 129-132
Open AccessPerformance test of cantilever transfer standard used for afm tip calibration based on electromagnetic compensation
This paper describes stiffness measurement of cantilever transfer standards used for Atomic Force Microscopy (AFM) tip calibration based on electromagnetic compensation. The transfer standard of cantilever is designed and manufactured based on the bulk fabrication of SOI wafers. The measure range of the transfer standard covers from 0.04 N/m to 16 N/m. The series of transfer standard is designed for the calibration test of the cantilever used in AFM, along with the test apparatus specifically designed. The relative uncertainty of the stiffness is smaller than 2.4 % (k = 2).
- 17 July 2020
- Published by Springer Nature in Science China Technological Sciences
- Vol. 63 (8) , 1497-1508
Electrical characteristics of laminar propane flame during head-on quenching
- 17 July 2020
- Published by Springer Nature in Science China Technological Sciences
- Vol. 63 (8) , 1497-1508
Electrical characteristics of laminar propane flame during head-on quenching
- 1 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 68 (7) , 2930-2943
Using Pulsed-RF Signals as Phase Standards for Millimeter-Wave Modulated Measurement and Calibration in Frequency Domain
This article presents the evaluation of using pulsed-radio frequency (RF) signals as multitone phase standards for modulated measurements at millimeter-wave (mm-Wave) bands, offering an alternative phase calibration choice for nonlinear vector network analyzers (NVNAs). Based on the NVNA measurements of two pulsed-RF signals generated by square-wave-driven mixers, a high correlation between magnitude and phase errors of unideal pulsed-RF signals is discovered, and an empirical method is developed to accurately estimate the phase errors according to magnitude-only measurements. To confirm its robustness and key preconditions for wide-range applications, theoretical support and explanation to the empirical method is revealed, in which the dominant waveform distortion of an applicable pulsed-RF signal can be decomposed into modulated perturbations with Sinc-like envelopes. The validity of the proposed empirical method, as well as its application for mm-Wave NVNA phase calibration, is verified by both experimental measurements and simulation results, where an estimation error (or phase calibration error) less than ±2° is demonstrated that is reachable in practice.
- 1 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 68 (7) , 2930-2943
Using Pulsed-RF Signals as Phase Standards for Millimeter-Wave Modulated Measurement and Calibration in Frequency Domain
This article presents the evaluation of using pulsed-radio frequency (RF) signals as multitone phase standards for modulated measurements at millimeter-wave (mm-Wave) bands, offering an alternative phase calibration choice for nonlinear vector network analyzers (NVNAs). Based on the NVNA measurements of two pulsed-RF signals generated by square-wave-driven mixers, a high correlation between magnitude and phase errors of unideal pulsed-RF signals is discovered, and an empirical method is developed to accurately estimate the phase errors according to magnitude-only measurements. To confirm its robustness and key preconditions for wide-range applications, theoretical support and explanation to the empirical method is revealed, in which the dominant waveform distortion of an applicable pulsed-RF signal can be decomposed into modulated perturbations with Sinc-like envelopes. The validity of the proposed empirical method, as well as its application for mm-Wave NVNA phase calibration, is verified by both experimental measurements and simulation results, where an estimation error (or phase calibration error) less than ±2° is demonstrated that is reachable in practice.