Ulrike Willer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ulrike Willer has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Wolfgang Schade
Optical Sensor Systems Department, Fraunhofer Heinrich Hertz Institute, Goslar, Germany
6 shared publications Wolfgang Schade
Optical Sensor Systems Department, Fraunhofer Heinrich Hertz Institute, Goslar, Germany
5 shared publicationsW. Schade
Clausthal Univ. of Technology (Germany)
4 shared publications- Michael Köhring
Department Fiber Optical Sensor Systems, Fraunhofer Heinrich Hertz Institute, Am Stollen 19H, 38640 Goslar, Germany
3 shared publications - Vladislav Reimer
Clausthal University of Technology Leibnizstrasse 4
3 shared publications M. Köhring
Fraunhofer Heinrich Hertz Institute (Germany)
2 shared publications
Latest Publications
- Open Access
- 25 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 41 (13) , 4366-4373
Ultra-Short Fiber Bragg Grating Used for Spectral Analysis of Guided Light in Single-Mode Fibers
An ultra-short fiber Bragg grating with a grating length of 0.2 mm and constant grating period (uniform FBG) is proposed as an integrated dispersive element for spectral analysis in a single-mode glass fiber. This dispersive element is used to set up a fiber optical spectrometer that demonstrated an average spectral resolving power of 825, a pixel resolution of 0.02 nm/pixel, and a 40 nm bandwidth covering the 810-850 nm wavelength range. Furthermore, the dependence of this dispersive element on light polarization was examined, which induces a reduction in the wavelength accuracy up to ±0.05 nm. Finally, the investigated spectrometer to function well as a part of a readout device for fiber Bragg grating sensors is presented. Short uniform Bragg gratings as dispersive elements allow the manufacturing of miniaturized, compact spectrometers without additional focusing components between the FBG and detector.
- 25 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 41 (13) , 4366-4373
Open AccessUltra-Short Fiber Bragg Grating Used for Spectral Analysis of Guided Light in Single-Mode Fibers
An ultra-short fiber Bragg grating with a grating length of 0.2 mm and constant grating period (uniform FBG) is proposed as an integrated dispersive element for spectral analysis in a single-mode glass fiber. This dispersive element is used to set up a fiber optical spectrometer that demonstrated an average spectral resolving power of 825, a pixel resolution of 0.02 nm/pixel, and a 40 nm bandwidth covering the 810-850 nm wavelength range. Furthermore, the dependence of this dispersive element on light polarization was examined, which induces a reduction in the wavelength accuracy up to ±0.05 nm. Finally, the investigated spectrometer to function well as a part of a readout device for fiber Bragg grating sensors is presented. Short uniform Bragg gratings as dispersive elements allow the manufacturing of miniaturized, compact spectrometers without additional focusing components between the FBG and detector.
- Open Access
- 1 June 2021
- Published by Elsevier in International Journal of Infectious Diseases
- Vol. 107, 12-14
Viral aerosol transmission of SARS-CoV-2 from simulated human emission in a concert hall
- 1 June 2021
- Published by Elsevier in International Journal of Infectious Diseases
- Vol. 107, 12-14
Open AccessViral aerosol transmission of SARS-CoV-2 from simulated human emission in a concert hall
- Open Access
- 16 March 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (6) , 3037
Experimental Investigation of Aerosol and CO2 Dispersion for Evaluation of COVID-19 Infection Risk in a Concert Hall
The dispersion of small aerosols in a concert hall is experimentally studied for estimating the risk of infection with SARS-CoV-2 during a concert. A mannequin was modified to emit an air stream containing aerosols and CO2. The aerosols have a size distribution with a peak diameter close to 0.3 µm and a horizontal initial particle velocity () of 2.4 m/s. The CO2-concentration (c) emitted simultaneously is 7500 ppm. It is investigated, if the spatial dissipation of aerosols and CO2 can be correlated. This would allow the use of technically easier CO2 measurements to monitor compliance with aerosol concentration limits. Both aerosol and CO2 concentrations are mapped by different sensors placed around the mannequin. As a result, no significant enrichment of aerosols and CO2 was obtained outside a radius of 1.5 m when the fresh air ventilation in the concert hall has a steady vertical flow with a velocity of and the installed ventilation system was operating at an air change rate per hour (ACH) of 3, corresponding to an air exchange rate of 51,000 m3/h. A Pearson correlation coefficient of 0.77 was obtained for CO2 and aerosol concentrations measured simultaneously at different positions within the concert hall.- 16 March 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (6) , 3037
Open AccessExperimental Investigation of Aerosol and CO2 Dispersion for Evaluation of COVID-19 Infection Risk in a Concert Hall
The dispersion of small aerosols in a concert hall is experimentally studied for estimating the risk of infection with SARS-CoV-2 during a concert. A mannequin was modified to emit an air stream containing aerosols and CO2. The aerosols have a size distribution with a peak diameter close to 0.3 µm and a horizontal initial particle velocity () of 2.4 m/s. The CO2-concentration (c) emitted simultaneously is 7500 ppm. It is investigated, if the spatial dissipation of aerosols and CO2 can be correlated. This would allow the use of technically easier CO2 measurements to monitor compliance with aerosol concentration limits. Both aerosol and CO2 concentrations are mapped by different sensors placed around the mannequin. As a result, no significant enrichment of aerosols and CO2 was obtained outside a radius of 1.5 m when the fresh air ventilation in the concert hall has a steady vertical flow with a velocity of and the installed ventilation system was operating at an air change rate per hour (ACH) of 3, corresponding to an air exchange rate of 51,000 m3/h. A Pearson correlation coefficient of 0.77 was obtained for CO2 and aerosol concentrations measured simultaneously at different positions within the concert hall. - Open Access
- 7 January 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (2) , 438
Phase Optimized Photoacoustic Sensing of Gas Mixtures
In this paper, we report on the progress of the auto-triggered quartz-enhanced photoacoustic spectroscopy (QEPAS) technique which operates without external frequency generators and ensures permanent locking to the current resonance frequency of the tuning fork. This is obtained by incorporating the tuning fork in an oscillator circuit that autonomously oscillates at the present resonance frequency that shifts with changing environmental conditions, e.g., density and viscosity of the surrounding gas, temperature, and pressure. Both, the oscillation amplitude as well as the frequency can be read from the oscillator circuit. The photoacoustic signal appears as an offset of the electrically induced signal amplitude. Since the sum amplitude depends on the phase relation between the electrical and photoacoustic driving forces, the phase is permanently modulated, enabling the extraction of the photoacoustic component by use of a second lock-in amplifier stage which is being referenced with the phase modulation frequency. The functionality of this method is demonstrated for methane detection in a carbon dioxide atmosphere in a concentration range from 0 to 100% and ammonia in synthetic air employing a pulsed mid infrared QCL around 1280 cm−1. The gas mixtures are motivated by the demands in biogas-analysis.
- 7 January 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (2) , 438
Open AccessPhase Optimized Photoacoustic Sensing of Gas Mixtures
In this paper, we report on the progress of the auto-triggered quartz-enhanced photoacoustic spectroscopy (QEPAS) technique which operates without external frequency generators and ensures permanent locking to the current resonance frequency of the tuning fork. This is obtained by incorporating the tuning fork in an oscillator circuit that autonomously oscillates at the present resonance frequency that shifts with changing environmental conditions, e.g., density and viscosity of the surrounding gas, temperature, and pressure. Both, the oscillation amplitude as well as the frequency can be read from the oscillator circuit. The photoacoustic signal appears as an offset of the electrically induced signal amplitude. Since the sum amplitude depends on the phase relation between the electrical and photoacoustic driving forces, the phase is permanently modulated, enabling the extraction of the photoacoustic component by use of a second lock-in amplifier stage which is being referenced with the phase modulation frequency. The functionality of this method is demonstrated for methane detection in a carbon dioxide atmosphere in a concentration range from 0 to 100% and ammonia in synthetic air employing a pulsed mid infrared QCL around 1280 cm−1. The gas mixtures are motivated by the demands in biogas-analysis.
- 1 January 2020
- Published by Optica Publishing Group
- p. EW1H.1
Gas Sensing Applications Using Miniaturized Optical Sensing Systems
In this review, two different methods for gas sensing applications are highlighted: QEPAS and a fiberoptic sensor relying on a change of refractive index when the target species is present.
- 1 January 2020
- Published by Optica Publishing Group
- p. EW1H.1
Gas Sensing Applications Using Miniaturized Optical Sensing Systems
In this review, two different methods for gas sensing applications are highlighted: QEPAS and a fiberoptic sensor relying on a change of refractive index when the target species is present.
- 2 August 2017
- Published by Springer Nature in Applied Physics B
- Vol. 123 (8) , 1-9
QEPAS with electrical co-excitation for photoacoustic measurements in fluctuating background gases
- 2 August 2017
- Published by Springer Nature in Applied Physics B
- Vol. 123 (8) , 1-9
QEPAS with electrical co-excitation for photoacoustic measurements in fluctuating background gases
- 3 June 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9482, 94820
Photoacoustic sensing with micro-tuning forks
- 3 June 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9482, 94820
Photoacoustic sensing with micro-tuning forks
- Open Access
LED-Absorption-QEPAS Sensor for Biogas Plants
A new sensor for methane and carbon dioxide concentration measurements in biogas plants is presented. LEDs in the mid infrared spectral region are implemented as low cost light source. The combination of quartz-enhanced photoacoustic spectroscopy with an absorption path leads to a sensor setup suitable for the harsh application environment. The sensor system contains an electronics unit and the two gas sensors; it was designed to work as standalone device and was tested in a biogas plant for several weeks. Gas concentration dependent measurements show a precision better than 1% in a range between 40% and 60% target gas concentration for both sensors. Concentration dependent measurements with different background gases show a considerable decrease in cross sensitivity against the major components of biogas in direct comparison to common absorption based sensors.
Open AccessLED-Absorption-QEPAS Sensor for Biogas Plants
A new sensor for methane and carbon dioxide concentration measurements in biogas plants is presented. LEDs in the mid infrared spectral region are implemented as low cost light source. The combination of quartz-enhanced photoacoustic spectroscopy with an absorption path leads to a sensor setup suitable for the harsh application environment. The sensor system contains an electronics unit and the two gas sensors; it was designed to work as standalone device and was tested in a biogas plant for several weeks. Gas concentration dependent measurements show a precision better than 1% in a range between 40% and 60% target gas concentration for both sensors. Concentration dependent measurements with different background gases show a considerable decrease in cross sensitivity against the major components of biogas in direct comparison to common absorption based sensors.
- 15 February 2015
- Published by Springer Nature in Applied Physics B
- Vol. 119 (1) , 111-118
An electrically and optically cooperated QEPAS device for highly integrated gas sensors
- 15 February 2015
- Published by Springer Nature in Applied Physics B
- Vol. 119 (1) , 111-118
An electrically and optically cooperated QEPAS device for highly integrated gas sensors
- Open Access
- 1 January 2014
- Published by Elsevier in Procedia Technology
- Vol. 15, 691-701
Towards Integrated Resonant and Interferometric Sensors in Polymer Films
- 1 January 2014
- Published by Elsevier in Procedia Technology
- Vol. 15, 691-701
Open AccessTowards Integrated Resonant and Interferometric Sensors in Polymer Films