CFClément Fausser

Clément Fausser

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Clément Fausser has a total of 38 co-authors. Here are the top co-authors by number of shared publications:

  • Nicolas Thiollay

    CEA, DES, IRESNE, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St Paul-Lez-Durance, France

    3 shared publications
  • Christophe Destouches

    CEA, DES, IRESNE, DER, Cadarache, F-13108 St Paul-Lez-Durance, France

    2 shared publications
  • Christophe Domergue

    CEA, DES, IRESNE, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St Paul-Lez-Durance, France

    2 shared publications
  • Franck Gabriel

    2 shared publications
  • Gilles Grégoire

    CEA, DES, IRESNE, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St Paul-Lez-Durance, France

    2 shared publications
  • Rosaria Villari

    2 shared publications

Latest Publications

  • Open Access

    Four decades of progress in PWRs surveillance program dosimetry measurements at the MADERE platform

    by Clément Fausser, Christophe Domergue, Hervé Philibert, Jonathan Bonora, Alexandra Pépino, Stéphane Bourganel, Kévin Jeuland, Céline Galant, Alexandre Subercaze, Gilles Grégoire, et al.

    Since 1981, the French Alternative Energies and Atomic Energy Commission has been measuring the dosimeters of the surveillance capsules of the French pressurized water reactors and assessing their neutron fluence. This represents more than 250 surveillance PWR capsules, i.e. 4 thousands dosimeters. Started in Grenoble, this work continued in Cadarache with the creation of the “Measurement Applied to DosimEtry in Reactors” (MADERE) platform within the Dosimetry, Sensors and Instrumentation Laboratory (LDCI). Since 1998, all surveillance dosimeters measurements (i.e. Al-Co, 238U, 237Np, Ni, Cu, Fe and Nb) have been performed at MADERE under the “Cofrac Essais” accreditation according to the ISO/IEC 17025 international standard. The evolution over time of the 1σ measurement uncertainty of the activity of each is presented in this paper. Since 2015, they are [±1.3% ; ±2.9%] for 238U with Ni encapsulation, [±0.8% ; ±2.1%] for 238U with Ti encapsulation, [±1.2% ; ±4.9%] for 238U with stainless steel encapsulation, ±1.3% for 237Np dosimeters, ±1.2% for Al-Co, [±1.2% ; ±1.4%] for nickel, copper and iron, [±3.3%; ±3.9%] for niobium if unbroken after irradiation.


  • Open Access

    CEA-JSI Experimental Benchmark for validation of the modeling of neutron and gamma-ray detection instrumentation used in the JSI TRIGA reactor

    by Clément Fausser, Nicolas Thiollay, Christophe Destouches, Loïc Barbot, Damien Fourmentel, Benoît Geslot, Grégoire De Izarra, Adrien Gruel, Gilles Grégoire, Christophe Domergue, et al.

    Constant improvements of the computational power and methods as well as demands of accurate and reliable measurements for reactor operation and safety require a continuous upgrade of the instrumentation. In particular, nuclear sensors used in nuclear fission reactors (research or power reactors) or in nuclear fusion facilities are operated under intense mixed neutron and gamma-ray fields, and need to be calibrated and modeled to provide selective and accurate neutron and gamma-ray measurements.The French Atomic Energy and Alternative Energies Commission (CEA) and the Jožef Stefan Institute (JSI) have started an experimental program dedicated to a detailed experimental benchmark with analysis using Monte Carlo particle transport calculations and a series of neutron and gamma-ray sensor types used in the JSI TRIGA Mark II reactor.CEA has setup a simplified TRIPOLI-4® modeling scheme of the JSI TRIGA reactor based on the information available in the IRPhEP benchmark in order to facilitate analysis of future neutron and gamma-ray measurements. These allow the CEA to perform a TRIPOLI-4 instrumentation calculation scheme benchmarked with the JSI MCNP model.This paper presents the main results of this CEA calculation scheme application and the analysis of their comparison to the JSI results obtained in 2012 with the MCNP5 & ENDF/B-VII.0 calculation scheme. This paper will conclude with some information about the new experimental program to be carried out in 2022 in the TRIGA reactor core.


  • Numerical Experiment to Validate an Advanced Methodology for Dosimetry in French Nuclear Reactors

    by Nicolas Thiollay, Clément Fausser, Stéphane Bourganel, Pietro Mosca

    The embrittlement monitoring in the reactor pressure vessel is of major interest for the operators of nuclear power plants. An upgrading of the procedure used to analyze dosimeters in the French surveillance capsules has been developed in the last years to improve the accuracy of the current methodology. This enhancement corresponds to the evolution of both the calculation codes and the nuclear data libraries in the last 20 years. Recent codes carry out more accurate neutron transport (TRIPOLI-4®) and depletion (DARWIN/PEPIN2) calculations and use modern cross-section data (JEFF3.1.1 and IRDF2002). This improvement goes together with the generation of a new adjustment code, CALMAR, to fit the fast calculated flux with dosimeter measurements. The validation of this upgraded methodology is partially attained comparing adjusted results with a large number of experiments available for the French pressurized water reactor fleet. Additional results are obtained with simulated “experiments” resulting from purely numerical simulations allowing one to test the robustness of the overall methodology versus input data. Information such as water density, compound expansion, steel thicknesses, water gaps, and fission spectra are investigated in order to test the capability of the methodology to find the solution even if input data are known with little accuracy. In addition, these numerical experiments aim to enrich the validation database of the CALMAR adjustment algorithm through comparisons with other adjustment codes widely used in the field of reactor dosimetry.

  • Presentation of the CALMAR-ECORCES Spectrum Adjustment Package Available at the NEA Data Bank

    by Gilles Grégoire, Christophe Destouches, Clément Fausser, Nicolas Thiollay


  • Tokamak D-T neutron source models for different plasma physics confinement modes

    by Clement Fausser, Antonella Li Puma, Franck Gabriel, Rosaria Villari


  • Numerical benchmarks TRIPOLI−MCNP with use of MCAM on FNG ITER bulk shield and FNG HCLL TBM mock-up experiments

    by Clement Fausser, Yi-Kang Lee, Rosaria Villari, Qin Zeng, Junjun Zhang, Arkady Serikov, Jean-Christophe Trama, Franck Gabriel