Sofia Arantes-Oliveira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sofia Arantes-Oliveira has a total of 119 co-authors. Here are the top co-authors by number of shared publications:
- Jaime Portugal
Dental Biomaterials Resarch Group (BIOMAT), Biomedical and Oral Science Research Unit (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal
31 shared publications - Paulo Melo
EpiUnit, Laboratory for Integrative and Translational Research in Population Health (ITR), Institute of Public Health, Faculty of Dental Medicine, University of Porto, Rua Dr. Manuel Pereira da Silva, 4200-393 Porto, Portugal
13 shared publications Ana Filipa Chasqueira
11 shared publications- João Cardoso Ferreira
Faculty of Dental Medicine, Department of Operative Dentistry, University of Porto, Rua Dr. Manuel Pereira da Silva, 4200-393 Porto, Portugal
8 shared publications Gonçalo Barragán
7 shared publications- Jorge Nuno Rosário Martins
Faculdade de Medicina Dentaria Universidade de Lisboa Lisboa Portugal
7 shared publications
Latest Publications
- Open Access
Bond Performance of Four Universal Adhesive Systems on Sound and Biomimetically Remineralized Artificially Caries-Affected Dentin Before and After Artificial Aging
Background: This study evaluated the bonding performance of four universal adhesive systems applied to sound dentin (SD) and artificially caries-affected dentin subjected to biomimetic remineralization with casein phosphopeptide–amorphous calcium phosphate (CPP–ACP), before and after artificial aging. Methods: One hundred and four human molars were allocated according to dentin substrate (SD or biomimetically remineralized [BRD]), adhesive system (FuturaBond® M+, Scotchbond™ Universal, Prime&Bond Active®, and One Coat7 Universal®), and aging (24 h or 10,000 thermocycles). Artificially caries-affected dentin was produced by pH cycling and subsequently remineralized with CPP–ACP. Adhesive interface morphology was assessed by FEG-ESEM, while shear bond strength (SBS) and failure modes were also evaluated. Statistical significance was set at p ≤ 0.05. Results: Adhesive layer thickness was significantly affected by the adhesive system, dentin substrate, and aging (p < 0.001), with a significant adhesive × substrate interaction (p < 0.001). Resin tag length was affected by the adhesive system (p = 0.03), substrate (p < 0.001), and aging (p < 0.001), with significant adhesive × substrate (p = 0.03) and adhesive × substrate × aging interactions (p = 0.001). SBS was significantly higher on SD than on BRD (p < 0.001) and decreased after thermocycling (p < 0.001). Conclusions: Universal adhesives exhibited substrate- and aging-dependent behaviour. BRD showed lower SBS than SD, while morphological differences did not consistently correspond to higher bond strength. Further studies including untreated artificially caries-affected dentin are needed to determine the specific contribution of CPP–ACP remineralization.
Open AccessBond Performance of Four Universal Adhesive Systems on Sound and Biomimetically Remineralized Artificially Caries-Affected Dentin Before and After Artificial Aging
Background: This study evaluated the bonding performance of four universal adhesive systems applied to sound dentin (SD) and artificially caries-affected dentin subjected to biomimetic remineralization with casein phosphopeptide–amorphous calcium phosphate (CPP–ACP), before and after artificial aging. Methods: One hundred and four human molars were allocated according to dentin substrate (SD or biomimetically remineralized [BRD]), adhesive system (FuturaBond® M+, Scotchbond™ Universal, Prime&Bond Active®, and One Coat7 Universal®), and aging (24 h or 10,000 thermocycles). Artificially caries-affected dentin was produced by pH cycling and subsequently remineralized with CPP–ACP. Adhesive interface morphology was assessed by FEG-ESEM, while shear bond strength (SBS) and failure modes were also evaluated. Statistical significance was set at p ≤ 0.05. Results: Adhesive layer thickness was significantly affected by the adhesive system, dentin substrate, and aging (p < 0.001), with a significant adhesive × substrate interaction (p < 0.001). Resin tag length was affected by the adhesive system (p = 0.03), substrate (p < 0.001), and aging (p < 0.001), with significant adhesive × substrate (p = 0.03) and adhesive × substrate × aging interactions (p = 0.001). SBS was significantly higher on SD than on BRD (p < 0.001) and decreased after thermocycling (p < 0.001). Conclusions: Universal adhesives exhibited substrate- and aging-dependent behaviour. BRD showed lower SBS than SD, while morphological differences did not consistently correspond to higher bond strength. Further studies including untreated artificially caries-affected dentin are needed to determine the specific contribution of CPP–ACP remineralization.
- Open Access
- 25 May 2026
- Published by MDPI AG in Preprints.org
Performance of Four Universal Adhesive Systems After Biomimetic Remineralization
Background: The aim of this study is to evaluate the influence of biomimetic remineralization on the performance of four universal adhesive systems applied to artificially caries-affected dentin before and after artificial aging. Methods: One hundred and four human molars were allocated to sixteen groups according to dentin condition (sound or biomimetically remineralized), adhesive system (FuturaBond® M+, Scotchbond™ Universal, Prime&Bond Active®, and One Coat7 Universal®), and aging (24h or 10,000 thermocycles). Artificially caries-affected dentin was prepared through pH cycling and then remineralized with CPP-ACP. Field-emission scanning electron microscopy (FEG-SEM) evaluated the adhesive interface. SBS testing assessed bond performance, and failure modes were classified under magnification. Results: Biomimetic remineralization modified the adhesive interface and influenced bond performance depending on adhesive system and aging. Scotchbond and Prime&Bond produced thicker adhesive layers than One Coat (p≤0.05), persisting after thermocycling (p<0.01). Futurabond showed greater resin tag formation in remineralized dentin compared with Scotchbond (p=0.04) and One Coat (p=0.004). Universal adhesives showed higher bond strength to sound dentin (p<0.001) than to biomimetic remineralized dentin. Failure patterns varied with substrate and aging. Conclusion: Biomimetic remineralization did not significantly alter bond strength among universal adhesives but positively influenced adhesive interface morphology.
- 25 May 2026
- Published by MDPI AG in Preprints.org
Open AccessPerformance of Four Universal Adhesive Systems After Biomimetic Remineralization
Background: The aim of this study is to evaluate the influence of biomimetic remineralization on the performance of four universal adhesive systems applied to artificially caries-affected dentin before and after artificial aging. Methods: One hundred and four human molars were allocated to sixteen groups according to dentin condition (sound or biomimetically remineralized), adhesive system (FuturaBond® M+, Scotchbond™ Universal, Prime&Bond Active®, and One Coat7 Universal®), and aging (24h or 10,000 thermocycles). Artificially caries-affected dentin was prepared through pH cycling and then remineralized with CPP-ACP. Field-emission scanning electron microscopy (FEG-SEM) evaluated the adhesive interface. SBS testing assessed bond performance, and failure modes were classified under magnification. Results: Biomimetic remineralization modified the adhesive interface and influenced bond performance depending on adhesive system and aging. Scotchbond and Prime&Bond produced thicker adhesive layers than One Coat (p≤0.05), persisting after thermocycling (p<0.01). Futurabond showed greater resin tag formation in remineralized dentin compared with Scotchbond (p=0.04) and One Coat (p=0.004). Universal adhesives showed higher bond strength to sound dentin (p<0.001) than to biomimetic remineralized dentin. Failure patterns varied with substrate and aging. Conclusion: Biomimetic remineralization did not significantly alter bond strength among universal adhesives but positively influenced adhesive interface morphology.
- Open Access
- 8 April 2025
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 26 (8) , 3488
Biomimetic Remineralization Strategies for Dentin Bond Stability—Systematic Review and Network Meta-Analysis
This systematic review and network meta-analysis aimed to evaluate the bond strength of artificial caries-affected dentin (ACAD) of permanent human teeth with and without biomimetic remineralization (BR), assessed based on in vitro studies. Following PRISMA guidelines, we conducted a systematic search until June 2023, identifying 82 eligible articles for full-text analysis. We assessed the study characteristics, methodological quality, and summary results. Bond strength was examined immediately and after artificial aging using three bond strength tests. We performed meta-regressions (using OpenBUGS software) to explore the relationship between the independent variable’s adhesive application technique (Etch-and-Rinse or Self-Etch) and ACAD protocol (chemical or biological) and the dependent variable of bond strength. Additionally, we conducted random-effect NMAs (using CINEMA software) to compare the effect of multiple interventions per application technique and ACAD protocol simultaneously. Among the included studies that compared various BR strategies, most studies (19 out of 22) presented a medium risk of bias. In some comparisons, the meta-regression results revealed a significant association between bond strength at 24 h and both the adhesive application technique and the ACAD protocol. Our findings indicate the potential of BR to enhance bond strength in human ACAD in in vitro settings.
- 8 April 2025
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 26 (8) , 3488
Open AccessBiomimetic Remineralization Strategies for Dentin Bond Stability—Systematic Review and Network Meta-Analysis
This systematic review and network meta-analysis aimed to evaluate the bond strength of artificial caries-affected dentin (ACAD) of permanent human teeth with and without biomimetic remineralization (BR), assessed based on in vitro studies. Following PRISMA guidelines, we conducted a systematic search until June 2023, identifying 82 eligible articles for full-text analysis. We assessed the study characteristics, methodological quality, and summary results. Bond strength was examined immediately and after artificial aging using three bond strength tests. We performed meta-regressions (using OpenBUGS software) to explore the relationship between the independent variable’s adhesive application technique (Etch-and-Rinse or Self-Etch) and ACAD protocol (chemical or biological) and the dependent variable of bond strength. Additionally, we conducted random-effect NMAs (using CINEMA software) to compare the effect of multiple interventions per application technique and ACAD protocol simultaneously. Among the included studies that compared various BR strategies, most studies (19 out of 22) presented a medium risk of bias. In some comparisons, the meta-regression results revealed a significant association between bond strength at 24 h and both the adhesive application technique and the ACAD protocol. Our findings indicate the potential of BR to enhance bond strength in human ACAD in in vitro settings.
- Open Access
- 11 March 2025
- Published by MDPI AG in Preprints.org
Biomimetic Remineralization Strategies on Dentin Bond Stability- Systematic Review and Network Meta-Analysis
This systematic review and network meta-analysis aimed to evaluate the bond strength of artificial caries-affected dentin (ACAD) of permanent human teeth with and without biomimetic remineralization (BR), assessed in in vitro studies. Following PRISMA guidelines, we conducted a systematic search until June 2023, identifying 82 eligible articles for full-text analysis. We assessed the study characteristics, methodological quality, and summary results. Bond strength was examined immediately and after artificial aging using three bond strength tests. We performed meta-regressions (using OpenBUGS software) to explore the relationship between the independent variable’s adhesive application technique (Etch-and-Rinse or Self-Etch) and ACAD protocol (chemical or biological) and the dependent variable bond strength. Additionally, we conducted random-effect NMAs (using CINEMA software) to compare the effect of multiple interventions per application technique and ACAD protocol simultaneously. Among the included studies that compared various BR strategies. Most studies (19 out of 22) presented a medium risk of bias. In some comparisons, meta-regression results revealed a significant association between bond strength at 24h and both the adhesive application technique and the ACAD protocol. Our findings indicate the potential of BR to enhance bond strength in human ACAD in in vitro settings .
- 11 March 2025
- Published by MDPI AG in Preprints.org
Open AccessBiomimetic Remineralization Strategies on Dentin Bond Stability- Systematic Review and Network Meta-Analysis
This systematic review and network meta-analysis aimed to evaluate the bond strength of artificial caries-affected dentin (ACAD) of permanent human teeth with and without biomimetic remineralization (BR), assessed in in vitro studies. Following PRISMA guidelines, we conducted a systematic search until June 2023, identifying 82 eligible articles for full-text analysis. We assessed the study characteristics, methodological quality, and summary results. Bond strength was examined immediately and after artificial aging using three bond strength tests. We performed meta-regressions (using OpenBUGS software) to explore the relationship between the independent variable’s adhesive application technique (Etch-and-Rinse or Self-Etch) and ACAD protocol (chemical or biological) and the dependent variable bond strength. Additionally, we conducted random-effect NMAs (using CINEMA software) to compare the effect of multiple interventions per application technique and ACAD protocol simultaneously. Among the included studies that compared various BR strategies. Most studies (19 out of 22) presented a medium risk of bias. In some comparisons, meta-regression results revealed a significant association between bond strength at 24h and both the adhesive application technique and the ACAD protocol. Our findings indicate the potential of BR to enhance bond strength in human ACAD in in vitro settings .
- Open Access
- 30 December 2024
- Published by Sociedade Portuguesa de Estomatologia e Medicina Dentaria (SPEMD) in Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial
- Vol. 65 (4) , 188-196
Effectiveness of three biomimetic remineralization procedures in artificial caries-affected dentin – an in-vitro pilot study
Objectives: Biomimetic remineralization strategies offer promising paths for managing caries- affected dentin by restoring its morphology and structural integrity. This pilot study aimed to assess the morphological and structural changes in dentin following two chemical artificial caries-affected dentin (ACAD) protocols, evaluate the effects of three biomimetic remineralization procedures (BRPs) on dentin structure, and determine the most effective ACAD-BRP combination. The BRPs studied were casein phosphopeptide-amorphous calcium phosphate (CPP-ACP), self-assembling P11-4 (SAP-P11-4), and calcium phosphate polymer- induced liquid precursor (Ca/P-PILP). Methods: Seventy-two specimens of healthy human dentin were divided into twelve groups. Half of each group’s samples were analyzed using field-emission gun environmental scanning electron microscope/energy dispersive X-ray, while the other half were analyzed by X-ray diffraction and micro-Raman spectroscopy. Results: Results demonstrate alterations in dentin morphology and structure induced by the ACAD protocols, affirming their effectiveness in mimicking caries-affected dentin. Among the BRPs evaluated, CPP-ACP emerged as the most promising agent for promoting remineralization and restoring dentin structure. The combination of pH cycling with CPP-ACP exhibited superior efficacy in promoting dentin remineralization compared to other combinations. Conclusions: These findings highlight the potential of biomimetic remineralization strategies, particularly CPP-ACP combined with pH cycling, as effective approaches for managing caries-affected dentin and preserving dental health.
- 30 December 2024
- Published by Sociedade Portuguesa de Estomatologia e Medicina Dentaria (SPEMD) in Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial
- Vol. 65 (4) , 188-196
Open AccessEffectiveness of three biomimetic remineralization procedures in artificial caries-affected dentin – an in-vitro pilot study
Objectives: Biomimetic remineralization strategies offer promising paths for managing caries- affected dentin by restoring its morphology and structural integrity. This pilot study aimed to assess the morphological and structural changes in dentin following two chemical artificial caries-affected dentin (ACAD) protocols, evaluate the effects of three biomimetic remineralization procedures (BRPs) on dentin structure, and determine the most effective ACAD-BRP combination. The BRPs studied were casein phosphopeptide-amorphous calcium phosphate (CPP-ACP), self-assembling P11-4 (SAP-P11-4), and calcium phosphate polymer- induced liquid precursor (Ca/P-PILP). Methods: Seventy-two specimens of healthy human dentin were divided into twelve groups. Half of each group’s samples were analyzed using field-emission gun environmental scanning electron microscope/energy dispersive X-ray, while the other half were analyzed by X-ray diffraction and micro-Raman spectroscopy. Results: Results demonstrate alterations in dentin morphology and structure induced by the ACAD protocols, affirming their effectiveness in mimicking caries-affected dentin. Among the BRPs evaluated, CPP-ACP emerged as the most promising agent for promoting remineralization and restoring dentin structure. The combination of pH cycling with CPP-ACP exhibited superior efficacy in promoting dentin remineralization compared to other combinations. Conclusions: These findings highlight the potential of biomimetic remineralization strategies, particularly CPP-ACP combined with pH cycling, as effective approaches for managing caries-affected dentin and preserving dental health.
- Open Access
- 10 April 2024
- Published by MDPI AG in Dentistry Journal
- Vol. 12 (4) , 98
Comparative Analysis of Endodontic ISO Size 06, 08, and 10 Stainless Steel K-Files Used for Glide Path Procedures
Small-sized stainless steel hand files are conventionally employed in root canal treatment procedures for canal scouting and for glide path establishment, owing to their superior flexibility and proficiency in navigating confined spaces. Given the diversity of brands available in the market, there exists potential variability in their physical characteristics, thereby influencing clinical performance. Consequently, this study aims to conduct a comparative analysis of the design, metallurgy, and mechanical characteristics among seven stainless steel hand file brands across ISO sizes 06, 08, and 10. A total of 315 new 25 mm length stainless steel hand files with apical sizes of 0.06, 0.08, and 0.10 from seven distinct brands were included in the study. A meticulous inspection of all instruments was undertaken to identify any structural deformations that might render them ineligible for the study. The design inspection involved the random selection of instruments from each group, which were examined under various microscopes, including a dental operating microscope, optical microscope, and scanning electron microscope. Furthermore, two instruments from each group underwent energy-dispersive X-ray spectroscopy analysis for elemental composition documentation. Mechanical tests were conducted to evaluate the instruments’ resistance to lateral deformation (buckling) and their microhardness. Statistical analysis was executed using the nonparametric Mood’s median test, with a predetermined significance level of 0.05. Regarding the instruments design, all files exhibited an active blade length ranging from 16 to 17 mm. However, variations were observed in the number of spirals, tip designs, and sizes, with the API K-File notably larger in sizes 0.06 and 0.08 compared to the other instruments. Despite uniform elements composition, differences in geometric features and mechanical properties were evident. Concerning buckling strength, the API K-File demonstrated superior performance across all tested sizes, while the Dentsply ReadySteel, SybronEndo, and Mani K-Files exhibited lower results (p < 0.05). In microhardness assessments, both the API and Oro K-Files displayed the lowest outcomes, with medians of 531 HVN and 532 HVN, respectively, whereas the SybronEndo K-File exhibited the highest microhardness (657 HVN). Despite similar metallurgical composition, the observed distinctions in geometric features and mechanical properties underscore the impact of the manufacturing process on the characteristics of glide path stainless steel endodontic files. These disparities may ultimately influence their clinical performance.
- 10 April 2024
- Published by MDPI AG in Dentistry Journal
- Vol. 12 (4) , 98
Open AccessComparative Analysis of Endodontic ISO Size 06, 08, and 10 Stainless Steel K-Files Used for Glide Path Procedures
Small-sized stainless steel hand files are conventionally employed in root canal treatment procedures for canal scouting and for glide path establishment, owing to their superior flexibility and proficiency in navigating confined spaces. Given the diversity of brands available in the market, there exists potential variability in their physical characteristics, thereby influencing clinical performance. Consequently, this study aims to conduct a comparative analysis of the design, metallurgy, and mechanical characteristics among seven stainless steel hand file brands across ISO sizes 06, 08, and 10. A total of 315 new 25 mm length stainless steel hand files with apical sizes of 0.06, 0.08, and 0.10 from seven distinct brands were included in the study. A meticulous inspection of all instruments was undertaken to identify any structural deformations that might render them ineligible for the study. The design inspection involved the random selection of instruments from each group, which were examined under various microscopes, including a dental operating microscope, optical microscope, and scanning electron microscope. Furthermore, two instruments from each group underwent energy-dispersive X-ray spectroscopy analysis for elemental composition documentation. Mechanical tests were conducted to evaluate the instruments’ resistance to lateral deformation (buckling) and their microhardness. Statistical analysis was executed using the nonparametric Mood’s median test, with a predetermined significance level of 0.05. Regarding the instruments design, all files exhibited an active blade length ranging from 16 to 17 mm. However, variations were observed in the number of spirals, tip designs, and sizes, with the API K-File notably larger in sizes 0.06 and 0.08 compared to the other instruments. Despite uniform elements composition, differences in geometric features and mechanical properties were evident. Concerning buckling strength, the API K-File demonstrated superior performance across all tested sizes, while the Dentsply ReadySteel, SybronEndo, and Mani K-Files exhibited lower results (p < 0.05). In microhardness assessments, both the API and Oro K-Files displayed the lowest outcomes, with medians of 531 HVN and 532 HVN, respectively, whereas the SybronEndo K-File exhibited the highest microhardness (657 HVN). Despite similar metallurgical composition, the observed distinctions in geometric features and mechanical properties underscore the impact of the manufacturing process on the characteristics of glide path stainless steel endodontic files. These disparities may ultimately influence their clinical performance.
- Open Access
- 31 January 2024
- Published by MDPI AG in Dentistry Journal
- Vol. 12 (2) , 29
Comparative Analysis of Endodontic 0.15 Stainless-Steel K-Files: Exploring Design, Composition, and Mechanical Performance
To establish a glide path, smaller files (up to size 0.15) with tapers of 2% are commonly used as pathfinding files. They pre-shape the root canal space before transitioning to larger taper endodontic instruments, aiming to prevent procedural errors. This study aimed to compare the design, metal wire composition, and mechanical characteristics of seven different ISO size 15 stainless-steel hand files (K-File and C-File+). Ninety-one new stainless-steel ISO 15 K-files were mechanically tested. All files were inspected for deformations before the assessment. Dental operating microscope, scanning electron microscope (SEM), and optical microscope analyses were conducted on four randomly selected instruments from each group, and two instruments per group underwent an energy-dispersive X-ray spectroscopy (EDS) analysis. Buckling mechanical tests were performed using an Instron universal testing machine, and microhardness was assessed using a Vickers hardness tester. The statistical analysis employed the nonparametric Mood’s median test, with a significance level set at 0.05. The instrument design analysis unveiled variations in the active blade area length and the number of spirals, while maintaining consistent cross-sections and symmetrical blades. Distinct tip geometries and surface irregularities were observed. While the energy-dispersive X-ray spectroscopy confirmed similar compositions, the buckling strength and microhardness values exhibited variability across for all tested files. Notably, the Dentsply ReadySteel C-File+ recorded the highest buckling value (2.10 N), and the Dentsply ReadySteel K-File exhibited the lowest (1.00 N) (p < 0.05). Moreover, the Dentsply ReadySteel K-File recorded the highest microhardness value (703 HVN), while the SybronEndo Triple-Flex had the lowest (549 HVN) (p < 0.05). While similarities in cross-section design and metal wire composition were noted among the files, variations in the number of spirals and mechanical performance were also observed. Thus, all of these factors should be considered when selecting suitable files for an efficient root canal treatment.
- 31 January 2024
- Published by MDPI AG in Dentistry Journal
- Vol. 12 (2) , 29
Open AccessComparative Analysis of Endodontic 0.15 Stainless-Steel K-Files: Exploring Design, Composition, and Mechanical Performance
To establish a glide path, smaller files (up to size 0.15) with tapers of 2% are commonly used as pathfinding files. They pre-shape the root canal space before transitioning to larger taper endodontic instruments, aiming to prevent procedural errors. This study aimed to compare the design, metal wire composition, and mechanical characteristics of seven different ISO size 15 stainless-steel hand files (K-File and C-File+). Ninety-one new stainless-steel ISO 15 K-files were mechanically tested. All files were inspected for deformations before the assessment. Dental operating microscope, scanning electron microscope (SEM), and optical microscope analyses were conducted on four randomly selected instruments from each group, and two instruments per group underwent an energy-dispersive X-ray spectroscopy (EDS) analysis. Buckling mechanical tests were performed using an Instron universal testing machine, and microhardness was assessed using a Vickers hardness tester. The statistical analysis employed the nonparametric Mood’s median test, with a significance level set at 0.05. The instrument design analysis unveiled variations in the active blade area length and the number of spirals, while maintaining consistent cross-sections and symmetrical blades. Distinct tip geometries and surface irregularities were observed. While the energy-dispersive X-ray spectroscopy confirmed similar compositions, the buckling strength and microhardness values exhibited variability across for all tested files. Notably, the Dentsply ReadySteel C-File+ recorded the highest buckling value (2.10 N), and the Dentsply ReadySteel K-File exhibited the lowest (1.00 N) (p < 0.05). Moreover, the Dentsply ReadySteel K-File recorded the highest microhardness value (703 HVN), while the SybronEndo Triple-Flex had the lowest (549 HVN) (p < 0.05). While similarities in cross-section design and metal wire composition were noted among the files, variations in the number of spirals and mechanical performance were also observed. Thus, all of these factors should be considered when selecting suitable files for an efficient root canal treatment.
- Open Access
- 1 December 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (12) , 3086
Evaluation of the Efficacy of CPP-ACP Remineralizing Mousse in Molar-Incisor Hypomineralized Teeth Using Polarized Raman and Scanning Electron Microscopy—An In Vitro Study
Remineralization of tooth enamel can be achieved by applying a complex of casein phosphopeptides and amorphous calcium phosphate (CPP-ACP). However, the efficacy and optimization of this agent in molar–incisor hypomineralization (MIH) lacks evidence. The purpose of this study is to evaluate the efficacy of CPP-ACP tooth mousse in remineralizing MIH-affected enamel in an optimized 28-day protocol using polarized Raman microscopy and scanning electron microscopy. The protocol was applied to two types of MIH opacities, white and yellow, and compared against sound enamel specimens before and after treatment. Data was analyzed using a one-way ANOVA and LSD post hoc multiple comparisons test (p < 0.05) for the Raman analysis. Hypomineralized enamel showed an improvement of its structure after CPP-ACP supplementation. In addition, Raman spectroscopy results showed a decrease in the depolarization ratio of the symmetric stretching band of phosphate (p < 0.05 for both groups). In conclusion, there was an improvement in mineral density and organization of the hypomineralized enamel after treatment with CPP-ACP tooth mousse.
- 1 December 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (12) , 3086
Open AccessEvaluation of the Efficacy of CPP-ACP Remineralizing Mousse in Molar-Incisor Hypomineralized Teeth Using Polarized Raman and Scanning Electron Microscopy—An In Vitro Study
Remineralization of tooth enamel can be achieved by applying a complex of casein phosphopeptides and amorphous calcium phosphate (CPP-ACP). However, the efficacy and optimization of this agent in molar–incisor hypomineralization (MIH) lacks evidence. The purpose of this study is to evaluate the efficacy of CPP-ACP tooth mousse in remineralizing MIH-affected enamel in an optimized 28-day protocol using polarized Raman microscopy and scanning electron microscopy. The protocol was applied to two types of MIH opacities, white and yellow, and compared against sound enamel specimens before and after treatment. Data was analyzed using a one-way ANOVA and LSD post hoc multiple comparisons test (p < 0.05) for the Raman analysis. Hypomineralized enamel showed an improvement of its structure after CPP-ACP supplementation. In addition, Raman spectroscopy results showed a decrease in the depolarization ratio of the symmetric stretching band of phosphate (p < 0.05 for both groups). In conclusion, there was an improvement in mineral density and organization of the hypomineralized enamel after treatment with CPP-ACP tooth mousse.
- Open Access
- 2 October 2022
- Published by MDPI AG in Dentistry Journal
- Vol. 10 (10) , 186
Evaluation of the Efficacy of CPP-ACP Remineralizing Mousse in MIH White and Yellow Opacities—In Vitro Vickers Microhardness Analysis
Remineralization of tooth enamel can be partially achieved by the application of a casein phosphopeptides and amorphous phosphate (CPP-ACP) complex. However, evidence to support its effectiveness in Molar-incisor-hypomineralization (MIH)-affected teeth is scarce. The study’s aim is to evaluate the efficacy of CPP-ACP mousse in remineralizing MIH-affected enamel using a Vickers microhardness test. Two groups of enamel opacities of hypomineralized permanent teeth, white (group A) and yellow (group B) lesions (n = 14), went through a 28-day treatment protocol with GC Tooth Mousse. Before and after treatment, microhardness was measured in three different areas of each tooth (hypomineralized, transition, and outside the hypomineralized area). Data were analyzed using parametric and non-parametric tests with a significance of p < 0.05. The mean microhardness values increased in the hypomineralized and transition areas in both groups after the treatment protocol (in group A, 105.38 ± 11.70 to 158.26 ± 37.34; 123.04 ± 22.84 to 156.33 ± 35.70; in group B, 108.63 ± 14.66 to 143.06 ± 22.81; 132.55 ± 20.66 to 146.00 ± 12.88) and the differences pre/post-treatment were statistically significant within each group (p < 0.001 for both groups). Between groups, there was a statistically significant difference in the same areas (hypomineralized: p = 0.003; transition: p = 0.008) with a higher improvement in enamel hardness in group A. Topical application of CPP-ACP showed an increase in the physical strength of the hypomineralized and transition areas of MIH-affected enamel, likely due to an increase in mineral content.
- 2 October 2022
- Published by MDPI AG in Dentistry Journal
- Vol. 10 (10) , 186
Open AccessEvaluation of the Efficacy of CPP-ACP Remineralizing Mousse in MIH White and Yellow Opacities—In Vitro Vickers Microhardness Analysis
Remineralization of tooth enamel can be partially achieved by the application of a casein phosphopeptides and amorphous phosphate (CPP-ACP) complex. However, evidence to support its effectiveness in Molar-incisor-hypomineralization (MIH)-affected teeth is scarce. The study’s aim is to evaluate the efficacy of CPP-ACP mousse in remineralizing MIH-affected enamel using a Vickers microhardness test. Two groups of enamel opacities of hypomineralized permanent teeth, white (group A) and yellow (group B) lesions (n = 14), went through a 28-day treatment protocol with GC Tooth Mousse. Before and after treatment, microhardness was measured in three different areas of each tooth (hypomineralized, transition, and outside the hypomineralized area). Data were analyzed using parametric and non-parametric tests with a significance of p < 0.05. The mean microhardness values increased in the hypomineralized and transition areas in both groups after the treatment protocol (in group A, 105.38 ± 11.70 to 158.26 ± 37.34; 123.04 ± 22.84 to 156.33 ± 35.70; in group B, 108.63 ± 14.66 to 143.06 ± 22.81; 132.55 ± 20.66 to 146.00 ± 12.88) and the differences pre/post-treatment were statistically significant within each group (p < 0.001 for both groups). Between groups, there was a statistically significant difference in the same areas (hypomineralized: p = 0.003; transition: p = 0.008) with a higher improvement in enamel hardness in group A. Topical application of CPP-ACP showed an increase in the physical strength of the hypomineralized and transition areas of MIH-affected enamel, likely due to an increase in mineral content.
- Open Access
Multimethod Assessment of Design, Metallurgical, and Mechanical Characteristics of Original and Counterfeit ProGlider Instruments
A multimethod study was conducted to assess the differences between original (PG-OR) and counterfeit (PG-CF) ProGlider instruments regarding design, metallurgical features, and mechanical performance. Seventy PG-OR and PG-CF instruments (n = 35 per group) were evaluated regarding the number of spirals, helical angles, and measuring line position by stereomicroscopy, while blade symmetry, cross-section geometry, tip design, and surface were assessed by scanning electron microscopy. Energy-dispersive X-ray spectroscopy and differential scanning calorimetry were used to identify element ratio and phase transformation temperatures, while cyclic fatigue, torsional, and bending testing were employed to assess their mechanical performance. An unpaired t-test and nonparametric Mann–Whitney U test were used to compare instruments at a significance level of 5%. Similarities were observed in the number of spirals, helical angles, blade symmetry, cross-sectional geometries, and nickel–titanium ratios. Measuring lines were more reliable in the original instrument, while differences were noted in the geometry of the tips (sharper tip for the original and rounded for the counterfeit) and surface finishing with PG-CF presenting more surface irregularities. PG-OR showed significantly more time to fracture (118 s), a higher angle of rotation (440°), and a lower maximum bending load (146.3 gf) (p < 0.05) than PG-CF (p < 0.05); however, maximum torque was similar for both instruments (0.4 N.cm) (p > 0.05). Although the tested instruments had a similar design, the original ProGlider showed superior mechanical behavior. The results of counterfeit ProGlider instruments were unreliable and can be considered unsafe for glide path procedures.
Open AccessMultimethod Assessment of Design, Metallurgical, and Mechanical Characteristics of Original and Counterfeit ProGlider Instruments
A multimethod study was conducted to assess the differences between original (PG-OR) and counterfeit (PG-CF) ProGlider instruments regarding design, metallurgical features, and mechanical performance. Seventy PG-OR and PG-CF instruments (n = 35 per group) were evaluated regarding the number of spirals, helical angles, and measuring line position by stereomicroscopy, while blade symmetry, cross-section geometry, tip design, and surface were assessed by scanning electron microscopy. Energy-dispersive X-ray spectroscopy and differential scanning calorimetry were used to identify element ratio and phase transformation temperatures, while cyclic fatigue, torsional, and bending testing were employed to assess their mechanical performance. An unpaired t-test and nonparametric Mann–Whitney U test were used to compare instruments at a significance level of 5%. Similarities were observed in the number of spirals, helical angles, blade symmetry, cross-sectional geometries, and nickel–titanium ratios. Measuring lines were more reliable in the original instrument, while differences were noted in the geometry of the tips (sharper tip for the original and rounded for the counterfeit) and surface finishing with PG-CF presenting more surface irregularities. PG-OR showed significantly more time to fracture (118 s), a higher angle of rotation (440°), and a lower maximum bending load (146.3 gf) (p < 0.05) than PG-CF (p < 0.05); however, maximum torque was similar for both instruments (0.4 N.cm) (p > 0.05). Although the tested instruments had a similar design, the original ProGlider showed superior mechanical behavior. The results of counterfeit ProGlider instruments were unreliable and can be considered unsafe for glide path procedures.