Dinghai Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dinghai Huang has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Sindee L. Simon
Department of Chemical and Biomolecular Engineering North Carolina State University Raleigh North Carolina USA
6 shared publications Jing Sheng
Department of Polymeric Material Science and Engineering, Institute of Advanced Polymer Materials, School of Material Science and Engineering Tianjin University Tianjin 300350 China
5 shared publicationsGregory B. McKenna
Department of Chemical Engineering, Texas Tech University , Lubbock, Texas 79409
4 shared publicationsJiaxiang Lin
Department of Polymer Material Science and Engineering, Institution of Advanced Polymer Materials, School of Material Science and Engineering Tianjin University, Tianjin, China
4 shared publicationsLi Song
Department of Polymer Material Science and Engineering, Institution of Advanced Polymer Materials, School of Material Science and Engineering Tianjin University, Tianjin, China
4 shared publicationsB. Lahlouh
Department of Physics, Texas Tech University, Lubbock, TX 79409, USA
3 shared publications
Latest Publications
- 14 February 2020
- Published by Royal Society of Chemistry (RSC) in CrystEngComm
- Vol. 22 (12) , 2247-2257
A new perspective to enhance the II–I transition of polybutene-1
The bottleneck for the application and potential utilization of polybutenene-1 (PB-1) with excellent physical and mechanical properties is its inevitable phase transition.
- 14 February 2020
- Published by Royal Society of Chemistry (RSC) in CrystEngComm
- Vol. 22 (12) , 2247-2257
A new perspective to enhance the II–I transition of polybutene-1
The bottleneck for the application and potential utilization of polybutenene-1 (PB-1) with excellent physical and mechanical properties is its inevitable phase transition.
- 10 June 2019
- Published by Royal Society of Chemistry (RSC) in CrystEngComm
- Vol. 21 (29) , 4243-4249
Role of conformation in crystal formation and transition of polybutene-1
Polymer conformation is the molecular basis underlying essentially all physical properties of polymers, and propensities of chain conformation and conformational energy play central roles in crystalline structure formations and structure transitions of polymers. Isotactic polybutene-1 (iPB-1) is a semi-crystalline polymer with polymorph and puzzle-like structure transitions. The stable form I of iPB-1 with excellent physical and mechanical properties can hardly be obtained directly from the melt but is formed from unstable form II which would spontaneously and slowly transform into form I. To obtain form I directly from the bulk iPB-1 melt by bypassing the unstable form II formation or ultrafast transition from form II is a challenging task. Here, we have investigated the formation and transition of iPB-1 crystalline structures with POM, DSC, in situ X-ray scattering and FTIR. The temperature related transition of form II to form I with or without solvents is characterized. It is found that the rate of transition decreases with temperature. An unexpected ultrafast transition is observed with solvents at room temperature, but the “stable” form II is investigated at high temperature with and without solvents. The conformation based mechanism of form II formation and packed-mesophase based transition is proposed, which would be helpful in understanding the physics of iPB-1 and polymer crystallization.
- 10 June 2019
- Published by Royal Society of Chemistry (RSC) in CrystEngComm
- Vol. 21 (29) , 4243-4249
Role of conformation in crystal formation and transition of polybutene-1
Polymer conformation is the molecular basis underlying essentially all physical properties of polymers, and propensities of chain conformation and conformational energy play central roles in crystalline structure formations and structure transitions of polymers. Isotactic polybutene-1 (iPB-1) is a semi-crystalline polymer with polymorph and puzzle-like structure transitions. The stable form I of iPB-1 with excellent physical and mechanical properties can hardly be obtained directly from the melt but is formed from unstable form II which would spontaneously and slowly transform into form I. To obtain form I directly from the bulk iPB-1 melt by bypassing the unstable form II formation or ultrafast transition from form II is a challenging task. Here, we have investigated the formation and transition of iPB-1 crystalline structures with POM, DSC, in situ X-ray scattering and FTIR. The temperature related transition of form II to form I with or without solvents is characterized. It is found that the rate of transition decreases with temperature. An unexpected ultrafast transition is observed with solvents at room temperature, but the “stable” form II is investigated at high temperature with and without solvents. The conformation based mechanism of form II formation and packed-mesophase based transition is proposed, which would be helpful in understanding the physics of iPB-1 and polymer crystallization.
- Open Access
- 14 February 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (10) , 5540-5549
Quantitative determination of the spring entropy effect and its indication of the conformational change of polymer coils with varying concentration in aqueous poly(N-isopropylamide) solutions
The lower critical solution temperature (LCST) phase separation behaviors of thermosensitive poly(N-isopropylacrylamide) (PNIPAM) aqueous solutions were investigated by power-compensation differential scanning calorimetry (DSC). The entropic effect and hence the change of swelling state of PNIPAM polymer coils in homogeneous concentrated aqueous solutions with varied solution composition was elucidated by the isothermal enthalpy demixing recovery behaviors in distinct concentration regions.
- 14 February 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (10) , 5540-5549
Open AccessQuantitative determination of the spring entropy effect and its indication of the conformational change of polymer coils with varying concentration in aqueous poly(N-isopropylamide) solutions
The lower critical solution temperature (LCST) phase separation behaviors of thermosensitive poly(N-isopropylacrylamide) (PNIPAM) aqueous solutions were investigated by power-compensation differential scanning calorimetry (DSC). The entropic effect and hence the change of swelling state of PNIPAM polymer coils in homogeneous concentrated aqueous solutions with varied solution composition was elucidated by the isothermal enthalpy demixing recovery behaviors in distinct concentration regions.
- 24 January 2019
- Published by Wiley in Journal of Polymer Science Part B: Polymer Physics
- Vol. 57 (6) , 323-330
Dual entropic and enthalpic processes in the lower critical solution temperature phase separation of poly(vinyl methyl ether) aqueous solutions
- 24 January 2019
- Published by Wiley in Journal of Polymer Science Part B: Polymer Physics
- Vol. 57 (6) , 323-330
Dual entropic and enthalpic processes in the lower critical solution temperature phase separation of poly(vinyl methyl ether) aqueous solutions
- 11 December 2018
- Published by Wiley in Journal of Polymer Science Part B: Polymer Physics
- Vol. 57 (3) , 142-151
Entropic effect implication for change in polymer coils swelling state in the demixing enthalpy recovery of aqueous poly(vinyl methyl ether) solutions
Time‐dependent demixing enthalpy recovery behavior of aqueous poly(vinyl methyl ether) (PVME) solutions exhibits distinct recovery characteristics in three concentration regions. The absence of recovery behavior below a water concentration of 38.3 wt % indicates that the PVME coil is in a globular state. The typically sigmoidal recovery behavior of demixing enthalpy above 38.3 wt % is ascribed to the reswelling of the collapsed polymer coils induced by the entropic effect. The increase in difference between the upper and lower limits indicates the continued swelling of the PVME coils. Above 65 wt %, a dominant diluting effect can be observed, and a much longer phase separation time is needed to reach the expected lower limit. In contrast, the recovery of demixing enthalpy in a wide range of water concentration (from 38.3 to 90 wt %) exhibits the same feature. The infrared spectroscopy results are in agreement with the above macroscopic differential scanning calorimetry results. © 2018 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2019, 57, 142–151
- 11 December 2018
- Published by Wiley in Journal of Polymer Science Part B: Polymer Physics
- Vol. 57 (3) , 142-151
Entropic effect implication for change in polymer coils swelling state in the demixing enthalpy recovery of aqueous poly(vinyl methyl ether) solutions
Time‐dependent demixing enthalpy recovery behavior of aqueous poly(vinyl methyl ether) (PVME) solutions exhibits distinct recovery characteristics in three concentration regions. The absence of recovery behavior below a water concentration of 38.3 wt % indicates that the PVME coil is in a globular state. The typically sigmoidal recovery behavior of demixing enthalpy above 38.3 wt % is ascribed to the reswelling of the collapsed polymer coils induced by the entropic effect. The increase in difference between the upper and lower limits indicates the continued swelling of the PVME coils. Above 65 wt %, a dominant diluting effect can be observed, and a much longer phase separation time is needed to reach the expected lower limit. In contrast, the recovery of demixing enthalpy in a wide range of water concentration (from 38.3 to 90 wt %) exhibits the same feature. The infrared spectroscopy results are in agreement with the above macroscopic differential scanning calorimetry results. © 2018 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2019, 57, 142–151
- Open Access
- 18 July 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (45) , 25636-25644
Synthesis of switchable intelligent molecularly imprinted polymers with selective adsorption of ethyl carbamate and their application in electrochemical sensor analysis
A cyclodextrin aldehyde based molecularly imprinted polymer with thermally responsive Diels–Alder (DA) linkages of grafted furan-type dienes was polymerized. The synthesized DA-MIP has dienophile characteristics and the specific absorption of ethyl carbamate (EC) can be switched on or off simply by thermal adjustment to 130 °C and 60 °C, respectively. The imprinting factors (α) of the MIP and rDA-MIP to EC were 6.2 and 5.0, and the selection factors (β) were 5.2 and 4.0, respectively. The restoration of the molecular target ratio was 88%, as determined by absorption and desorption experiments. The thermal restoration ratio, determined by thermal cycling experiments, was 78%. A new electrochemical sensor was prepared using the DA-MIP and its responsiveness for detecting trace amounts of EC was investigated. The results indicate that the electrode response has good affinity and excellent specific recognition performance for template molecular chemicals.
- 18 July 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (45) , 25636-25644
Open AccessSynthesis of switchable intelligent molecularly imprinted polymers with selective adsorption of ethyl carbamate and their application in electrochemical sensor analysis
A cyclodextrin aldehyde based molecularly imprinted polymer with thermally responsive Diels–Alder (DA) linkages of grafted furan-type dienes was polymerized. The synthesized DA-MIP has dienophile characteristics and the specific absorption of ethyl carbamate (EC) can be switched on or off simply by thermal adjustment to 130 °C and 60 °C, respectively. The imprinting factors (α) of the MIP and rDA-MIP to EC were 6.2 and 5.0, and the selection factors (β) were 5.2 and 4.0, respectively. The restoration of the molecular target ratio was 88%, as determined by absorption and desorption experiments. The thermal restoration ratio, determined by thermal cycling experiments, was 78%. A new electrochemical sensor was prepared using the DA-MIP and its responsiveness for detecting trace amounts of EC was investigated. The results indicate that the electrode response has good affinity and excellent specific recognition performance for template molecular chemicals.
- 3 June 2017
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 130 (2) , 843-850
Time dependence of phase separation enthalpy recovery behavior in aqueous poly(N-isopropylacrylamide) solution
- 3 June 2017
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 130 (2) , 843-850
Time dependence of phase separation enthalpy recovery behavior in aqueous poly(N-isopropylacrylamide) solution
- 26 December 2013
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 47 (1) , 297-303
Double Glass Transition Temperatures of Poly(methyl methacrylate) Confined in Alumina Nanotube Templates
- 26 December 2013
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 47 (1) , 297-303
Double Glass Transition Temperatures of Poly(methyl methacrylate) Confined in Alumina Nanotube Templates
- 18 October 2013
- Published by Taylor & Francis in Journal of Macromolecular Science, Part B
- Vol. 53 (1) , 1-12
Visualization and Characterization of Discontinuous Particle Films of Polystyrene by Atomic Force Microscopy
Discontinuous particle films of polystyrene (PS) with different molecular weights were prepared by the methods of spin coating (SPC) and droplet evaporation (DE) at room temperature on mica substrates. Visualization and characterization of these samples were performed by atomic force microscopy (AFM). The results showed that the dimensions of the particles in the films increased with molecular weight. The dimensions of the particles in the films derived from SPC exhibited better uniformity than those from DE. During the steps of particle film formation by SPC, the PS molecules gathered in large clusters at the early stage, then the polymer aggregates were separated or spun off, and more and more particles emerged, finally the clusters vanished and the particle film formed. The particles of the spin-coated film dewetted after annealing and numerous individual polymer chains appeared newly on the mica substrate.
- 18 October 2013
- Published by Taylor & Francis in Journal of Macromolecular Science, Part B
- Vol. 53 (1) , 1-12
Visualization and Characterization of Discontinuous Particle Films of Polystyrene by Atomic Force Microscopy
Discontinuous particle films of polystyrene (PS) with different molecular weights were prepared by the methods of spin coating (SPC) and droplet evaporation (DE) at room temperature on mica substrates. Visualization and characterization of these samples were performed by atomic force microscopy (AFM). The results showed that the dimensions of the particles in the films increased with molecular weight. The dimensions of the particles in the films derived from SPC exhibited better uniformity than those from DE. During the steps of particle film formation by SPC, the PS molecules gathered in large clusters at the early stage, then the polymer aggregates were separated or spun off, and more and more particles emerged, finally the clusters vanished and the particle film formed. The particles of the spin-coated film dewetted after annealing and numerous individual polymer chains appeared newly on the mica substrate.
- 3 November 2012
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 129 (1) , 86-93
Microwave preparation and copper ions adsorption properties of crosslinked chitosan/ZSM molecular sieve composites
A novel chitosan‐based composite (CTS/ZSM) made of chitosan and ZSM molecular sieve was prepared under microwave irradiation and was used for the removal of Cu (II) ions from aqueous solution. The composites were characterized by FTIR spectra, XRD spectra, and thermogravimetric analysis. The effects of the ZSM content, amount of glutaraldehyde and pH value on adsorption properties of Cu (II) ions by CTS/ZSM were discussed in detail. Contrast with crosslinked chitosan (CCTS), the CTS/ZSM had higher adsorption capacity for Cu (II). Kinetic studies showed that the adsorption of Cu (II) onto CTS/ZSM composite had low correlation coefficients for the pseudo‐first and ‐second order model and intraparticle diffusion model. The equilibrium process was better described by the Langmuir than Freundlich isotherm model. © 2012 Wiley Periodicals, Inc. J. Appl. Polym. Sci., 2013
- 3 November 2012
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 129 (1) , 86-93
Microwave preparation and copper ions adsorption properties of crosslinked chitosan/ZSM molecular sieve composites
A novel chitosan‐based composite (CTS/ZSM) made of chitosan and ZSM molecular sieve was prepared under microwave irradiation and was used for the removal of Cu (II) ions from aqueous solution. The composites were characterized by FTIR spectra, XRD spectra, and thermogravimetric analysis. The effects of the ZSM content, amount of glutaraldehyde and pH value on adsorption properties of Cu (II) ions by CTS/ZSM were discussed in detail. Contrast with crosslinked chitosan (CCTS), the CTS/ZSM had higher adsorption capacity for Cu (II). Kinetic studies showed that the adsorption of Cu (II) onto CTS/ZSM composite had low correlation coefficients for the pseudo‐first and ‐second order model and intraparticle diffusion model. The equilibrium process was better described by the Langmuir than Freundlich isotherm model. © 2012 Wiley Periodicals, Inc. J. Appl. Polym. Sci., 2013