BTBruce A. Tomkins

Bruce A. Tomkins

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bruce A. Tomkins has a total of 92 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Xylan hydrolysis in Populus trichocarpa×P. deltoides and model substrates during hydrothermal pretreatment

    by Heather L. Trajano, Sivakumar Pattathil, Bruce A. Tomkins, Timothy J. Tschaplinski, Michael G. Hahn, Gary J. Van Berkel, Charles E. Wyman


  • Stable Carbon and Nitrogen Isotope Ratios of Sodium and Potassium Cyanide as a Forensic Signature

    by Helen W. Kreuzer, Juske Horita, James J. Moran, Bruce A. Tomkins, Derek B. Janszen, April Carman

    Abstract:  Sodium and potassium cyanide are highly toxic, produced in large amounts by the chemical industry, and linked to numerous high‐profile crimes. The U.S. Centers for Disease Control and Prevention has identified cyanide as one of the most probable agents to be used in a chemical terrorism event. We investigated whether stable C and N isotopic content of sodium and potassium cyanide could serve as a forensic signature for sample matching, using a collection of 65 cyanide samples. Upon analysis, a few of the cyanide samples displayed nonhomogeneous isotopic content associated with degradation to a carbonate salt and loss of hydrogen cyanide. Most samples had highly reproducible isotope content. Of the 65 cyanide samples, >95% could be properly matched based on C and N isotope ratios, with a false match rate <3%. These results suggest that stable C and N isotope ratios are a useful forensic signature for matching cyanide samples.


  • Thin-Layer Chromatography/Desorption Electrospray Ionization Mass Spectrometry: Investigation of Goldenseal Alkaloids

    by Gary J. Van Berkel, Bruce A. Tomkins, Vilmos Kertesz

    Desorption electrospray ionization mass spectrometry was investigated as a means to qualitatively identify and to quantify analytes directly from developed normal-phase thin-layer chromatography plates. The atmospheric sampling capillary of a commercial ion trap mass spectrometer was extended to permit sampling and ionization of analytes in bands separated on intact TLC plates (up to 10 cm × 10 cm). A surface positioning software package and the appropriate hardware enabled computer-controlled surface scanning along the length of development lanes or at fixed Rf value across the plates versus the stationary desorption electrospray emitter. Goldenseal (Hydrastis canadensis) and related alkaloids and commercial dietary supplements were used as standards and samples. Alkaloid standards and samples were spotted and separated on aluminum- or glass-backed plates using established literature methods. The mass spectral signal levels as a function of desorption spray solvent were investigated with acetonitrile proving superior to methanol. The detection levels (∼5 ng each or 14−28 pmol) in mass spectral full-scan mode were determined statistically from the calibration curves (2.5−100 pmol) for the standards berberine, palmatine, and hydrastinine spotted as a mixture and separated on the plates. Qualitative screening of the major alkaloids present in six different over-the-counter “goldenseal” dietary supplements was accomplished by obtaining full-scan mass spectra during surface scans along the development lane in the direction of increasing Rf value. In one sample, alkaloids were detected that strongly suggested the presence of at least one additional herb undeclared on the product label. These same data indicated the misidentification of one of the alkaloids in the TLC literature. Quantities of the alkaloids present in two of the samples determined using the mass spectral data were in reasonable agreement with the label values, indicating the quantitative ability of the method. The advantage of mass spectral measurements in identifying and quantifying materials within overlapping bands and in providing positive identification for even minor species in a mixture was also demonstrated.


  • Open Access

    Quantitation of Cotinine in Nonsmoker Saliva Using Chip-Based Nanoelectrospray Tandem Mass Spectrometry

    by Bruce A. Tomkins, Gary J. Van Berkel, Roger A. Jenkins, Richard W. Counts

    A new analytical procedure was developed for the quantitation of nonsmoker salivary cotinine. Small volumes of saliva were diluted with water, fortified with cotinine-d3 (internal standard), then passed through small extraction columns. The analyte and internal standard were eluted with 0.1% (v/v) acetic acid/acetonitrile. Aliquots of each extract were analyzed directly, without chromatographic separation, using chip-based (NanoMate™) nanospray tandem mass spectrometry. The calculated detection limit was 0.49 ng cotinine/mL saliva. This method was used to quantify salivary cotinine collected from nonsmoking human subjects living in one of three environmental tobacco smoke (ETS) exposure categories or “cells”: 1. smoking home/smoking workplace; 2. smoking home/nonsmoking workplace; and 3. nonsmoking home/smoking workplace. Samples were collected during five sequential days, including Saturday, as part of a larger study to evaluate potential variability in exposure to ETS. Salivary cotinine measurements were made for the purpose of excluding misclassified smokers and for comparison with known levels of exposure to airborne nicotine in each exposure category. The concentrations observed were consistent with those reported from other large studies reported elsewhere. A non-parametric statistical test was applied to the data within each cell. No statistically significant differences were found between the mean cotinine concentrations collected on a weekday as compared to those collected on a weekend day. When the non-parametric test was applied to the three cells, a statistically significant difference was observed between cell 1 compared to cells 2 and 3. The salivary cotinine concentrations were thus statistically invariant over a five-day exposure period, and they were greatest under the conditions of smoking home and smoking workplace.


  • Self‐aspirating atmospheric pressure chemical ionization source for direct sampling of analytes on surfaces and in liquid solutions

    by Keiji G. Asano, Michael J. Ford, Bruce A. Tomkins, Gary J. Van Berkel

    A self‐aspirating heated nebulizer probe is described and demonstrated for use in the direct analysis of analytes on surfaces and in liquid samples by atmospheric pressure chemical ionization (APCI) mass spectrometry. Functionality and performance of the probe as a self‐aspirating APCI source is demonstrated using reserpine and progesterone as test compounds. The utility of the probe to sample analytes directly from surfaces was demonstrated first by scanning development lanes of a reversed‐phase thin‐layer chromatography plate in which a three‐component dye mixture, viz., Fat Red 7B, Solvent Green 3, and Solvent Blue 35, was spotted and the components were separated. Development lanes were scanned by the sampling probe operated under computer control (x, y plane) while full‐scan mass spectra were recorded using a quadrupole ion trap mass spectrometer. In addition, the ability to sample the surface of pharmaceutical tablets (viz., Extra Strength Tylenol® and Evista® tablets) and to detect the active ingredients (acetaminophen and raloxifene, respectively) selectively was demonstrated using tandem mass spectrometry (MS/MS). Finally, the capability to sample analyte solutions from the wells of a 384‐well microtiter plate and to perform quantitative analyses using MS/MS detection was illustrated with cotinine standards spiked with cotinine‐ d 3 as an internal standard. Published in 2005 by John Wiley & Sons, Ltd.


  • Quantitative Thin-Layer Chromatography/Mass Spectrometry Analysis of Caffeine Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    by Michael J. Ford, Michael A. Deibel, Bruce A. Tomkins, Gary J. Van Berkel

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 μm/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 μL) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by ∼8% or more) than the literature values.


  • Synthesis and Properties of Calix[4]arene‐bis[4‐(2‐ethylhexyl)benzo‐crown‐6], A Cesium Extractant with Improved Solubility

    by Nancy L. Engle, Peter V. Bonnesen, Bruce A. Tomkins, Tamara J. Haverlock, Bruce A. Moyer

    The new cesium‐selective macrocycle calix[4]arene‐bis[4‐(2‐ethylhexyl) benzo‐crown‐6] (“BEHBCalixC6”) has been found to have improved solubility in a modified alkane diluent over calix[4]arene‐bis(4‐tert‐octylbenzo‐crown‐6) (“BOBCalixC6”). The synthesis of this new calixcrown extractant, together with its solubility and extraction properties, is described in this report. The solubility, cesium extraction, and potassium loading behavior are compared with those of BOBCalixC6, the macrocycle currently employed in the caustic‐side solvent extraction (CSSX) process for extracting cesium from alkaline nitrate solutions such as high‐level nuclear waste. Replacement of the tert‐octyl alkyl chains on the benzo‐crown portion of the calixcrown by 2‐ethylhexyl chains improves the equilibrium solubility of the free calixcrown in aliphatic diluents while not affecting the cesium extraction strength. Equilibrium concentrations of BEHBCalixC6 in Isopar L diluent modified with 0.5 M 1‐(2,2,3,3‐tetrafluoropropoxy)...


  • Open Access

    Development and Application of Protocols for the Determination of Response of Real-Time Particle Monitors to Common Indoor Aerosols

    by Roger A. Jenkins, Ralph H. Ilgner, Bruce A. Tomkins, Douglas W. Peters

    Protocols have been developed and applied for the generation of aerosols that are likely to be comparable to those encountered in field settings for the calibration of easily transportable/portable real-time particle monitors. Aerosols generated were simulated environmental tobacco smoke, cedar wood smoke, cooking oil fumes, and propane stove particles. The time-integrated responses of three nephelometers and a monitor for particle-bound polynuclear aromatic hydrocarbons (PAH) were compared with gravimetric respirable suspended particulate matter (RSP) in a controlled-atmosphere chamber. In general, the monitor responses increased linearly with increasing mass concentration. However, the two monitors that reported mass per volume concentrations tended to overreport the actual RSP concentrations by factors up to 4.4. The real-time PAH monitor did not respond to cooking oil fumes, indicative of little PAH being present in the aerosol. One of the monitors that has been used in a variety of studies reported in the literature (DustTrak) was collocated with gravimetric RSP samplers in several hospitality venues in the Louisville, KY, area. Field studies indicated that the units overreported actual RSP concentrations by factors of 2.6–3.1, depending on whether the sampling was conducted in the nonsmoking or smoking sections of the facilities.


  • Next Generation Extractants for Cesium Separation from High-Level Waste: From Fundamental Concepts to Site Implementation

    by Bruce A Moyer, Eve Bazelaire, Peter V Bonnesen, Jeffrey C Bryan, Laetitia H Delmau, Nancy L Engle, Maryna G Gorbunova, Tamara J Keever, Tatiana G Levitskaia, Richard A Sachleben, et al.

    This project seeks a fundamental understanding and major improvement in cesium separation from high-level waste by cesium-selective calixcrown extractants. Systems of particular interest involve novel solvent-extraction systems containing specific members of the calix[4]arene-crown-6 family, alcohol solvating agents, and alkylamines. Questions being addressed pertain to cesium binding strength, extraction selectivity, cesium stripping, and extractant solubility. Enhanced properties in this regard will specifically benefit cleanup projects funded by the USDOE Office of Environmental Management to treat and dispose of high-level radioactive wastes currently stored in underground tanks at the Savannah River Site (SRS), the Hanford site, and the Idaho National Environmental and Engineering Laboratory.1 The most direct beneficiary will be the SRS Salt Processing Project, which has recently identified the Caustic-Side Solvent Extraction (CSSX) process employing a calixcrown as its preferred technology for cesium removal from SRS high-level tank waste.2 This technology owes its development in part to fundamental results obtained in this program.