HKHyung-Jin Kim

Hyung-Jin Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hyung-Jin Kim has a total of 140 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Open- and closed-type congenital cholesteatomas of the middle ear: computed tomography differentiation and correlation with surgical staging

    by Minjung Seong, Hyung-Jin Kim, Yikyung Kim, Sung Tae Kim

    Open- and closed-type congenital cholesteatomas of the middle ear: computed tomography differentiation and correlation with surgical staging - Diagnostic and Interventional Radiology


  • Open Access

    Findings of Intravenous Gadolinium Inner Ear Magnetic Resonance Imaging in Patients With Acute Low-Tone Sensorineural Hearing Loss

    by Hee Won Seo, Yikyung Kim, Hyung-Jin Kim, Won-Ho Chung, Young Sang Cho

    Objectives Acute low-tone sensorineural hearing loss (ALHL) is thought to have a different etiology from that of idiopathic sudden sensorineural hearing loss. We hypothesized that endolymphatic hydrops (EH) in the inner ear organ contributes to ALHL, even in patients without vertigo. This study investigated the presence of EH in ALHL and compared the clinical characteristics of patients with or without EH.Methods We retrospectively reviewed 38 patients diagnosed with ALHL without vertigo from January 2017 to March 2022. EH was measured in all patients using inner ear magnetic resonance imaging (MRI). In addition, we selected patients who showed only mid- or high-frequency hearing loss and had available MRI data as a control group and compared the ALHL and control groups.Results After treatment, the pure-tone average at low frequencies significantly improved compared to the initial hearing (P<0.001). Hearing recovery was observed in 63.1% of patients; however, the recovery rate did not differ based on the treatment method. During the follow-up period, six patients (15.8%) progressed to Meniere’s disease, and 18 (47.4%) experienced recurrence. In the ALHL group, the cochlear hydrops ratio on the affected side (0.34±0.09) was significantly higher than on the contralateral side (0.29±0.12) (P=0.005), and most patients showed hydrops in the apex area of the cochlea. Compared with the control group (0.25±0.15), the ALHL group showed a significantly higher cochlear hydrops ratio (P=0.043). The correlation analysis showed a tendency for hearing thresholds at low frequencies to increase as the hydrops ratio increased, albeit without statistical significance.Conclusion The cochlear hydrops ratio, especially in the apex area on the affected side, was significantly higher in patients with ALHL, suggesting that EH in the cochlea contributes to the pathogenesis of ALHL.


  • Open Access

    Increasing discrepancy of MR imaging and CSF study in patients with leptomeningeal seeding from lung adenocarcinoma after targeted therapy using a tyrosine kinase inhibitor

    by Minjung Seong, Sehhoon Park, Sung Tae Kim, Sung Goo Park, Yikyung Kim, Jihoon Cha, Eung Yeop Kim, Hyung-Jin Kim, Myung-Ju Ahn

    Purpose: To evaluate the correlation between contrast-enhanced (CE) MRI and cerebrospinal fluid (CSF) cytology for the evaluation of leptomeningeal metastasis (LM) on MRI after targeted therapy with tyrosine kinase inhibitors. Methods: We retrospectively reviewed the data of nonsmall cell lung cancer patients registered with NCT03257124 from May 2017 to December 2018, with progressive disease despite targeted therapy. Twenty-nine patients whose MRI scans exhibited LM at the time of registration were enrolled. During the targeted therapy with osimertinib, MRI scans, and subsequent CSF examinations were performed in every 2 months. In total, 113 MRI scans and CSF cytology data after treatment were collected. For each CE MRI scan, LM positivity was evaluated on 3D T1-weighted image (T1WI) and 2D FLAIR. The correlation between MRI and CSF cytology results and the diagnostic performance of MRI with CSF cytology as a reference standard were evaluated. Results: After treatment, MRI revealed positivity for LM in 81 and negativity in 32. CSF results were positive in 69 examinations and negative in 44. The diagnostic accuracy of CE 3D T1WI and 2D FLAIR was 0.52 and 0.46, respectively. After targeted therapy, discrepancy in the CSF and MRI results tended to increase over time. The proportions of concordant MRI and CSF cytology results after targeted therapy were 66%, 58%, 62%, and 47% at the first, second, third, and fourth follow-up, respectively. Conclusion: The discrepancy of MRI in evaluation of LM and CSF cytology increases over time after targeted therapy with osimertinib. LM positivity on MRI could be a surrogate imaging marker in the pre- and immediate posttargeted-treatment with Osimertinib but not after sessions of osimertinib.


  • Open Access

    Imaging of Facial Nerve With 3D-DESS-WE-MRI Before Parotidectomy: Impact on Surgical Outcomes

    by Han-Sin Jeong, Yikyung Kim, Hyung-Jin Kim, Hak Jung Kim, Eun-Hye Kim, Sook-Young Woo, Man Ki Chung, Young-Ik Son

    Jeong HS, et al. Korean J Radiol. 2023 Aug;24:e48. https://doi.org/10.3348/kjr.2022.0850


  • Open Access

    Neuroretinitis after the second injection of a SARS-CoV-2-vaccine: A case report

    by Chaeyeon Lee, Kyung-Ah Park, Don-Il Ham, Minjung Seong, Hyung-Jin Kim, Ga-In Lee, Sei Yeul Oh


  • Open Access

    A Fully Automated Analytic System for Measuring Endolymphatic Hydrops Ratios in Patients With Ménière Disease via Magnetic Resonance Imaging: Deep Learning Model Development Study

    by Chae Jung Park, Young Sang Cho, Myung Jin Chung, Yi-Kyung Kim, Hyung-Jin Kim, Kyunga Kim, Jae-Wook Ko, Won-Ho Chung, Baek Hwan Cho

    Background: Recently, the analysis of endolymphatic hydropses (EHs) via inner ear magnetic resonance imaging (MRI) for patients with Ménière disease has been attempted in various studies. In addition, artificial intelligence has rapidly been incorporated into the medical field. In our previous studies, an automated algorithm for EH analysis was developed by using a convolutional neural network. However, several limitations existed, and further studies were conducted to compensate for these limitations. Objective: The aim of this study is to develop a fully automated analytic system for measuring EH ratios that enhances EH analysis accuracy and clinical usability when studying Ménière disease via MRI. Methods: We proposed the 3into3Inception and 3intoUNet networks. Their network architectures were based on those of the Inception-v3 and U-Net networks, respectively. The developed networks were trained for inner ear segmentation by using the magnetic resonance images of 124 people and were embedded in a new, automated EH analysis system—inner-ear hydrops estimation via artificial intelligence (INHEARIT)-version 2 (INHEARIT-v2). After fivefold cross-validation, an additional test was performed by using 60 new, unseen magnetic resonance images to evaluate the performance of our system. The INHEARIT-v2 system has a new function that automatically selects representative images from a full MRI stack. Results: The average segmentation performance of the fivefold cross-validation was measured via the intersection of union method, resulting in performance values of 0.743 (SD 0.030) for the 3into3Inception network and 0.811 (SD 0.032) for the 3intoUNet network. The representative magnetic resonance slices (ie, from a data set of unseen magnetic resonance images) that were automatically selected by the INHEARIT-v2 system only differed from a maximum of 2 expert-selected slices. After comparing the ratios calculated by experienced physicians and those calculated by the INHEARIT-v2 system, we found that the average intraclass correlation coefficient for all cases was 0.941; the average intraclass correlation coefficient of the vestibules was 0.968, and that of the cochleae was 0.914. The time required for the fully automated system to accurately analyze EH ratios based on a patient's MRI stack was approximately 3.5 seconds. Conclusions: In this study, a fully automated full-stack magnetic resonance analysis system for measuring EH ratios was developed (named INHEARIT-v2), and the results showed that there was a high correlation between the expert-calculated EH ratio values and those calculated by the INHEARIT-v2 system. The system is an upgraded version of the INHEARIT system; it has higher segmentation performance and automatically selects representative images from an MRI stack. The new model can help clinicians by providing objective analysis results and reducing the workload for interpreting magnetic resonance images.


  • Open Access

    A Fully Automated Analytic System for Measuring Endolymphatic Hydrops Ratios in Patients With Ménière Disease via Magnetic Resonance Imaging: Deep Learning Model Development Study (Preprint)

    by Chae Jung Park, Young Sang Cho, Myung Jin Chung, Yi-Kyung Kim, Hyung-Jin Kim, Kyunga Kim, Jae-Wook Ko, Won-Ho Chung, Baek Hwan Cho

    BACKGROUND Recently, the analysis of endolymphatic hydropses (EHs) via inner ear magnetic resonance imaging (MRI) for patients with Ménière disease has been attempted in various studies. In addition, artificial intelligence has rapidly been incorporated into the medical field. In our previous studies, an automated algorithm for EH analysis was developed by using a convolutional neural network. However, several limitations existed, and further studies were conducted to compensate for these limitations. OBJECTIVE The aim of this study is to develop a fully automated analytic system for measuring EH ratios that enhances EH analysis accuracy and clinical usability when studying Ménière disease via MRI. METHODS We proposed the 3into3Inception and 3intoUNet networks. Their network architectures were based on those of the Inception-v3 and U-Net networks, respectively. The developed networks were trained for inner ear segmentation by using the magnetic resonance images of 124 people and were embedded in a new, automated EH analysis system—inner-ear hydrops estimation via artificial intelligence (INHEARIT)-version 2 (INHEARIT-v2). After fivefold cross-validation, an additional test was performed by using 60 new, unseen magnetic resonance images to evaluate the performance of our system. The INHEARIT-v2 system has a new function that automatically selects representative images from a full MRI stack. RESULTS The average segmentation performance of the fivefold cross-validation was measured via the intersection of union method, resulting in performance values of 0.743 (SD 0.030) for the 3into3Inception network and 0.811 (SD 0.032) for the 3intoUNet network. The representative magnetic resonance slices (ie, from a data set of unseen magnetic resonance images) that were automatically selected by the INHEARIT-v2 system only differed from a maximum of 2 expert-selected slices. After comparing the ratios calculated by experienced physicians and those calculated by the INHEARIT-v2 system, we found that the average intraclass correlation coefficient for all cases was 0.941; the average intraclass correlation coefficient of the vestibules was 0.968, and that of the cochleae was 0.914. The time required for the fully automated system to accurately analyze EH ratios based on a patient's MRI stack was approximately 3.5 seconds. CONCLUSIONS In this study, a fully automated full-stack magnetic resonance analysis system for measuring EH ratios was developed (named INHEARIT-v2), and the results showed that there was a high correlation between the expert-calculated EH ratio values and those calculated by the INHEARIT-v2 system. The system is an upgraded version of the INHEARIT system; it has higher segmentation performance and automatically selects representative images from an MRI stack. The new model can help clinicians by providing objective analysis results and reducing the workload for interpreting magnetic resonance images.

  • Open Access

    Adenocarcinoma of the minor salivary gland with concurrent MAML2 and EWSR1 alterations

    by Sangjoon Choi, Junhun Cho, Seung Eun Lee, Chung-Hwan Baek, Yi-Kyung Kim, Hyung-Jin Kim, Young Hyeh Ko

    Salivary gland tumors are histologically diverse, and each entity has distinctive histopathological and molecular features. We report two cases of salivary gland tumors with unique histological and molecular findings, which have not been documented previously. The tumors were located in the base of the tongue in both patients. Most tumor cells were arranged in cords and nests, giving a trabecularlike appearance. Focally, glandular structures with intraluminal mucin and perivascular pseudorosette-like configurations were identified. Tumor cells had eosinophilic to clear cytoplasm, and showed mild nuclear atypia. They were positive for pancytokeratin and negative for S-100, p63, c-KIT, androgen receptor, and neuroendocrine markers. Multiple foci of capsular or lymphovascular invasion were identified, but the Ki-67 labeling index was low (< 5%). Fluorescence in situ hybridization revealed concurrent alterations of MAML2 and EWSR1 gene. Further investigations with a larger number of cases with similar histological and molecular features will accurately classify this tumor.


  • Three-dimensional double-echo steady-state with water excitation magnetic resonance imaging to localize the intraparotid facial nerve in patients with deep-seated parotid tumors

    by Yikyung Kim, Han-Sin Jeong, Hyung-Jin Kim, Minjung Seong, Yoonha Kim, Sung Tae Kim

    Purpose To assess the utility of three-dimensional double-echo steady-state with water excitation (3D-DESS-WE) imaging for localizing deep-seated parotid tumors in relation to the facial nerve. Methods A prospective study comparing the surgical outcomes of parotidectomy with or without 3D-DESS-WE sequence is currently enrolling the patients. Magnetic resonance imaging data from the first 25 patients with 3D-DESS-WE sequence were reviewed. Visibility of the intraparotid facial nerve was independently assessed by two neuroradiologists. The diagnostic performance of the 3D-DESS-WE sequence for prediction of deep lobe involvement was compared with that of two conventional methods based on the retromandibular vein line (RMVL) and facial nerve line (FNL). The relationship between the tumor and the main trunk of the facial nerve was also evaluated on the 3D-DESS-WE sequence. Results On 3D-DESS-WE images, the main trunk, temporofacial division, and cervicofacial division of the intraparotid facial nerve were visualized in 100% (25/25), 48% (12/25), and 36% (9/25) of patients, respectively. The diagnostic accuracy of the 3D-DESS-WE sequence for prediction of deep lobe involvement was 92% (23/25), which was significantly superior to that of the RMVL (68% [17/25]; p = 0.008) and FNL (64% [16/25]; p = 0.004) methods. The relationship between the tumor and the main trunk of the facial nerve was correctly predicted in 92% (23/25) of 3D-DESS-WE images. Conclusion By direct visualization of the facial nerve, the 3D-DESS-WE sequence improved the preoperative localization of the intraparotid facial nerve in deep-seated parotid tumors. This information may help better surgical planning for deep-seated parotid tumors.