OIOdunAyo Imoru

OdunAyo Imoru

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


OdunAyo Imoru has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative Analysis of High Impedance Fault Detection Techniques on Distribution Networks

    by Ester Hamatwi, Odunayo Imoru, Matheus M. Kanime, Hitila S. A. Kanelombe

    This study focused on comparing the performance of three high impedance fault detection techniques for the case of a distribution network to select the technique that is best suited for detecting faults in this network. The three most common techniques; discrete Fourier transform, discrete wavelet transform, and the power spectrum among other techniques were selected for the research work based on literature. The distribution network was modelled in MATLAB/Simulink, along with the High Impedance Fault condition. These fault detection techniques were modelled and applied separately to the distribution network under different operating conditions: high impedance fault, load switching, and normal operation. The suitability of these techniques for the distribution network is evaluated by comparing them in terms of accuracy, processing time, and fault detection margin. The power spectrum technique was found to be the most suitable technique for detecting high impedance faults on a distribution network, with a 100% accuracy, a shorter processing time, and a larger fault detection margin.


  • Open Access

    OFDM Network Optimization Using a QPSK Based on a Wind-Driven Genetic Algorithm

    by Yanxia Sun, Chikomborero Shambare, OdunAyo Imoru

    Quadrature phase shift keying (QPSK) is a digital modulation technique that transmits data at a constant frequency whilst varying the phases of the carrier signal. QPSK is one of the fundamental modulation schemes for orthogonal frequency division multiplexing systems (OFDM). It is a stable modulation technique with good spectral efficiency. However, during transmission, the carrier signal can undergo numerous phase changes. This creates phase ambiguity problems at the receiver end. This results in inter-symbol interference (ISI) and a high bit error rate (BER). In this paper, the wind-driven optimization was incorporated into the genetic algorithm (GA) as its population selection function. This hybrid algorithm was used to determine the phase assignments for the QPSK. The developed QPSK was implemented on an OFDM network and the message signal was recovered at more than 92% accuracy in a noisy Rayleigh fading channel and 100% accuracy in a noiseless channel. The enhancements greatly mitigated phase ambiguity and bit errors.


  • A neural network approach to detect winding faults in electrical machine

    by OdunAyo Imoru, Fulufhelo V. Nelwamondo, Adisa Jimoh, Temitope Raphael Ayodele

    In this paper, Neural Network (NN) approach is developed and utilised to detect winding faults in an electrical machine using the samples data of electrical machine in both the healthy and different fault conditions (i.e. shorted-turn fault, phase-to-ground fault and coil-to-coil fault). This is done by interfacing a data acquisition device connected to the machine with a computer in the laboratory. Thereafter, a two-layer feed-forward network with Levenberg–Marquardt back-propagation algorithm is created with the collected input dataset. The NN model developed was tested with both the healthy and the four different fault conditions of the electrical machine. The results from the NN approach was also compared with other results obtained by determining the fault index (FI) of an electrical machine using signal processing approach. The results show that the NN approach can identify each of the electrical machine condition with high accuracy. The percentage accuracy for healthy (normal), shorted-turn, phase-to-ground and coil-to-coil fault conditions are 99, 99.6, 100 and 100% respectively.


  • Early Diagnosis of Induction Machine Stator Winding Faults by Discrete Wavelet Transform

    by OdunAyo Imoru, M. Arun Bhaskar, Adisa Abdul-Ganiyu Jimoh, Yskandar Hamam

  • Diagnosis of stator shorted-turn faults in induction machines using discrete wavelet transform

    by OdunAyo Imoru, M. Arun Bhaskar, Adisa Abdul-Ganiyu Jimoh, Yskandar Hamam

    Incipient detection and diagnosis of stator winding shorted-turn faults in induction machines is essential for reliable and economical operations in industries. The problem of detecting shorted-turn faults in stator windings has been difficult. Although, from the supply currents, major winding faults can easily be detected, minor faults with less than five per cent of winding turns are not easily detectable. If not detected early, such faults can lead to major winding faults which may further lead to the disruption of the machine and causes production shutdowns. This paper describes the discrete wavelet transform (DWT) based diagnosis technique that analyses stator currents under faulty (stator shorted-turn) and healthy conditions. The developed technique depends on the band pass filtering carried out by the DWT, facilitating the extraction of the harmonic components produced by the shorted-turn faults. The discrepancies energy spectrum for three frequencies from the residual of de-noising analysis enables us to classify the fault index. From 38 seconds, the shorted turn begins to show significant difference in the energy spectrum, and if this is not detected in time, it may lead to a more serious fault.