TSTânia Mara da Silva

Tânia Mara da Silva

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tânia Mara da Silva has a total of 114 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Longitudinal bond strength of a universal adhesive and chemical dentin characterization under different acid etching protocols

    by Lucélia Lemes Gonçalves, Anuradha Prakki, Tânia Mara da Silva, Arwa Bafail, Janaína Bortolatto, Alexander Terry Stavroullakis, Sérgio Eduardo de Paiva Gonçalves

    This study aimed to analyze the longitudinal bond strength of a universal adhesive and chemically characterize the dentin substrate under different acid etching protocols.


  • Chemical and morphological analysis of dentin collagen degradation after Nd:YAG laser irradiation

    by Stephanie Ribeiro Lopes, Tânia Mara da Silva, Andrea Maselli, Lucélia Lemes Gonçalves, Tiago Moreira Bastos Campos, Sérgio Eduardo de Paiva Gonçalves


  • Open Access

    Effect of fluoride, chlorhexidine or Nd:YAG on the progression of root dentin demineralization after removal of the demineralized organic matrix

    by Andrea Maselli, Tânia Mara da Silva, Lucélia Lemes Gonçalves, Aline Silva Braga, Eduardo Bresciani, Ana Carolina Magalhães, Sérgio Eduardo de Paiva Gonçalves

    Evaluate preventive methods against root collagen degradation by the hydroxyproline assay (HYP) and microradiography technique (MRT). Five bovine root dentin blocks were obtained and subjected to an artificial demineralization process by acetate buffer (pH 5) to induce carious lesion formation. Samples were subjected to the following therapeutic treatments: 1) 0.12% chlorhexidine for 1 min, 2) 2% fluoride for 1 min, 3) Nd:YAG Laser (400 μm diameter optical fiber, 10 Hz frequency, 60 mJ/pulse energy, 48 J/cm2 energy density, in noncontact mode for 10 s), 4) deionized water (control) for 1 min, 5) MRT control group (without treatment and removal of collagen). Samples were exposed to degradation by a collagenase enzyme for five days. The enzyme solution was collected, by colorimetry in a spectrophotometer, from the collagen matrix for the hydroxyproline release analysis. The same samples were subjected to an additional two days of demineralization to induce the progression of mineral loss. Samples were analyzed by MRT for the visualization of their degraded areas (estimation of lesion depth and mineral loss). ANOVA was applied to compare hydroxyproline release rates. MRT data were subjected to the Kruskal-Wallis test, followed by the Dunn’s test. Comparisons between the initial five-day and the subsequent two-day demineralization processes were performed by repeated t-test or Wilcoxon (p<0.05) measurements. The amount of HYP released from the dentin samples failed to show significant differences among the groups (p=0.09). Fluoride and chlorhexidine were able to interact with the samples, reducing the progression of dentin caries after removal of the demineralized organic matrix. CHX was the only treatment able to show significant lower lesion depth than the negative control. Chlorhexidine and fluoride were effective in reducing root caries progression.


  • Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentin

    by Lucélia Lemes Gonçalves, Tânia Mara Da Silva, Anuradha Prakki, Daphne Camara Barcellos, Taciana Marco Ferraz Caneppele, Hueder Paulo Moisés De Oliveira, Sérgio Eduardo de Paiva Gonçalves

    The aim of this study was to evaluate the effect of SPP with either fetal bovine serum (FBS) or deionized water (DW) on the bond strength (μTBS) of a Universal adhesive to dentin, in both etch-and-rinse (ER) and self-etch (SE) modes. The kinematic viscosity (cSt) of FBS and DW was measured at 25 °C ± 0.1 ºC. Seventy-two sound human molars were sectioned and randomly divided into three groups according to the SPP conditions: (1) Control (0 cm H2O), (2) SPP (15 cm H2O) with FBS, (3) SPP (15 cm H2O) with DW. Each group was subdivided (n = 10) based on the bonding modes: ER (37% phosphoric acid + ScothBond Universal Adhesive) or SE (ScothBond Universal Adhesive). Samples were then submitted to μTBS. Data were analyzed by Student’s t test, two-way ANOVA and Tukey tests (p < 0.05). The cSt results showed that DW (23.59 ± 0.39) had significantly higher values than FBS (22.33 ± 0.06). With regard to SPP, the control group (36.1 MPa) had significantly higher values of μTBS when compared to the SPP using FBS (31.06 MPa) and SPP with DW (26.55 MPa). According to ANOVA, the bonding modes and the interaction of simulated pulpal pressure (SPP) did not statistically influence the results (p < 0.05). The presence of SPP reduced the bond strength of Universal adhesive to dentin. DW during SPP had significantly reduced bonding values when compared to FBS. Bonding strategies were not affected by SPP when evaluated in a short period of time (24 h).


  • Addition of EGCG to self-etching primer: effect on adhesive properties and bond stability to dentin

    by Fernando Pelegrim Fernandes, Carolina Côcco Adorno, Tânia Mara da Silva, Fabiana Mantovani Gomes França, Cecilia Pedroso Turssi, Roberta Tarkany Basting, Sérgio Eduardo de Paiva Gonçalves, Flávia Lucisano Botelho Amaral

    This study evaluated how adding EGCG to a SEP (Clearfil SE Bond, Kuraray) affects the physicomechanical properties of adhesive, and the long-term microtensile bond strength (µTBS) to dentin. Flexural strength (FS, n = 10) and degree of conversion (DC, n = 5) of the adhesive were analyzed after adding EGCG to SEP in two forms (powder or diluted in water), and in different concentrations (0.00%–control, 0.01%, 0.02% and 0.05%). The µTBS was tested by randomly dividing dentin fragments into 4 groups (n = 10): EGCG-SEP: EGCG (0.01%) added to SEP; EGCG-PRE: EGCG (0.01%) dentin pretreatment; CHX-PRE: 2% chlorhexidine dentin pretreatment; SEP: SEP applied without modification. After restoration of the dentin surface, beam-shaped specimens were submitted to µTBS after 24 h or 12 months of storage in artificial saliva. Particle size (PS), polydispersity index (PDI) and zeta potential (ZP) of EGCG-SEP and SEP solutions were measured at different storage periods (baseline, 14 or 28 days). Data was submitted to ANOVA or Kruskal–Wallis tests (α = 0.05). FS (p = 0.485) and DC (p = 0.6067) were not different among the groups. CHX-PRE and EGCG-PRE had significantly higher µTBS means than EGCG-SEP, but none differed from SEP (p = 0.053). µTBS decreased significantly after 12 months of storage (p < 0.001). PS (p < 0.001), and ZP (p = 0.003) means in EGCG-SEP were statistically higher and more negative, respectively, than SEP. PDI did not differ among the groups (p > 0.05). Incorporation of EGCG into SEP did not change adhesive properties; however, it influenced solution stability and did not prevent the decrease in long-term µTBS to dentin.


  • Open Access

    Analysis of adhesive bond strength under simulated pulpal pressure on different dentin thicknesses

    by Bruno Amaral Haddad, Tânia Mara Silva, Lucélia Lemes Gonçalves, Mateus Rodrigues Silva, Cláudio Moreira Junior, Leandro Ruivo Santis, Sérgio Eduardo de Paiva Gonçalves

    Objective: Evaluate the microtensile bond strength (µTBS) in different dentin thicknesses, under simulated pulpal pressure (SPP), submitted to an adhesive technique using laser irradiation. Material and methods: Forty sound human molars were sectioned and randomly divided into two groups (n=20): Group 1 – 1 mm of dentin thickness; Group 2 – 2 mm of dentin thickness. Each group was divided into two subgroups (n=10): Subgroup A – Absence of SPP; Subgroup P – Presence of SPP (15 cm H2O). The samples were sequentially treated with: 37% phosphoric acid, adhesive system (Adper Single Bond 2), Nd:YAG laser irradiation (60 s, 1064 nm, 10 Hz) using 60 and 100 mJ/pulse energy parameters and photopolymerization (10 s). A composite resin block (Filtek Z350) was built up onto the irradiated area. After 30 days stored in water, the samples were sectioned and submitted to microtensile test (10 kgf load cell, 0.5mm/min). Data were analyzed by three-way ANOVA and Tukey tests. Results: Three-way ANOVA revealed no significant differences for SPP (p=0.0821) and for dentin thickness p= 0.9405) on bond strength. The laser energy parameters (p=0.001) indicated that 100 mJ showed greater µTBS means compared to the group irradiated with 60 mJ. Dentin thickness did not affect on µTBS. The presence of SPP reduced the mean µTBS values. Conclusions: Simulated pulpal pressure did not affect the µTBS using 60 mJ of laser energy parameter. At 100 mJ, the presence of SPP negatively influenced the bond strength, regardless of dentin thickness. KEYWORDS Bond strength; Dentin; Intrapulpal pressure; Nd:YAG laser.

  • Effect of zinc chloride added to self-etching primer on bond strength to caries-affected dentin and chemical-physical-mechanical properties of adhesives

    by R.M.P. Campos, C.A.R. Oliveira, J.P.C. Macedo, F.M.G. França, R.T. Basting, C.P. Turssi, T.M. Silva, S.E.P. Gonçalves, F.L.B. Amaral


  • Bonding Performance of Simplified Adhesive Systems in Noncarious Cervical Lesions at 2-year Follow-up: A Double-blind Randomized Clinical Trial

    by Rf Zanatta, Tm Silva, Malr Esper, E Bresciani, Sep Gonçalves, Tmf Caneppele

    SUMMARY: Objectives: This study aimed to evaluate the bonding performance of a universal adhesive used according to self-etching or etch-and-rinse protocols in noncarious cervical lesions (NCCLs) and to compare the two protocols with their respective gold standard techniques. Methods and Materials: This randomized, double-blind clinical study enrolled 34 participants who met the inclusion criteria, 29 of whom returned after two years. They received 152 restorations bonded with one of the three adhesives (Scotchbond Universal Adhesive, Adper Single Bond 2, or Clearfil SE Bond) and one of the two bonding techniques tested. The NCCLs were restored with nanocomposite resin (Filtek Supreme). Final contours were done with a fine diamond rotary instrument and polished with rubber points. The restorations were evaluated using the FDI World Dental Federation criteria at baseline (seven days after the restoration procedure), 6, 12, and 24 months. Descriptive statistics, Kruskal-Wallis, Friedman analysis of variance, and least significant difference tests were performed. Results: No statistically significant differences were found in esthetics or the functional and biological evaluated criteria among the adhesive systems and techniques. Conclusions: The Scotchbond Universal system behaved similarly to the conventional etch-and-rinse or self-etching systems in all the adhesion strategies in the evaluated periods.


  • Open Access

    Surface degradation of composite resins under staining and brushing challenges

    by Tânia Mara da Silva, Débora Cristina Barbosa Dantas, Tainá Teixeira Franco, Lucas Teixeira Franco, Maria Filomena Rocha Lima Huhtala