Asep Santoso
Research Subjects
Asep Santoso has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
Iwan Budiwan Anwar
Department of Orthopaedic and Traumatology, Universitas Sebelas Maret, Surakarta, Indonesia
8 shared publications- Nicolaas Cyrillus Budhiparama
Department of Orthopaedic and Traumatology, Faculty of Medicine, Universitas Airlangga, Surabaya, Indonesia
6 shared publications Pamudji Utomo
Department of Orthopaedics and Traumatology, Universitas Sebelas Maret, Prof. Dr. R. Soeharso Orthopaedic Hospital, Surakarta, Indonesia
5 shared publications- Sholahuddin Rhatomy
Department of Orthopaedic and Traumatology, dr. Soeradji Tirtonegoro General Hospital, Faculty of Medicine, Gadjah Mada University, Yogyakarta, Indonesia
5 shared publications - Iwan Budiwan Anwar
Department of Orthopaedic and Traumatology, Prof. Dr. R. Soeharso Orthopaedic Hospital – Universitas Sebelas Maret, Sukoharjo, Central Java, Indonesia
4 shared publications - Kyung-Soon Park
Department of Orthopedic Surgery, Chonnam National University Medical School and Hwasun Hospital, Hwasun-gun 58128, Jeollanam-do, Republic of Korea
4 shared publications
Latest Publications
- Open Access
- 26 May 2026
- Published by Elsevier in Trauma & Case Reports
- Vol. 64, 101374
Successful re-distraction osteogenesis on the consolidated bone resulted from previous distraction osteogenesis of tibia: A case report
- 26 May 2026
- Published by Elsevier in Trauma & Case Reports
- Vol. 64, 101374
Open AccessSuccessful re-distraction osteogenesis on the consolidated bone resulted from previous distraction osteogenesis of tibia: A case report
- Open Access
- 22 May 2026
- Published by Elsevier in Trauma & Case Reports
- Vol. 64, 101375
Ankle arthrodesis with non-vascularized fibular graft for neglected comminuted talar body fracture: A case report
- 22 May 2026
- Published by Elsevier in Trauma & Case Reports
- Vol. 64, 101375
Open AccessAnkle arthrodesis with non-vascularized fibular graft for neglected comminuted talar body fracture: A case report
- Open Access
- 22 April 2026
- Published by Universa Medicina in Universa Medicina
- Vol. 45 (1) , 135-152
Umbilical cord mesenchymal stem cells and their secretome: a new frontier in orthopedic medicine
Umbilical cord mesenchymal stem cells (UC-MSCs) have gained significant attention in regenerative medicine due to their unique biological properties, including high proliferation capacity, low immunogenicity, and potent immunomodulatory effects. These characteristics make UC-MSCs particularly promising for orthopedic applications, where the repair and regeneration of musculoskeletal tissues such as bone, cartilage, tendons, ligaments, and nerves are critical for restoring function. The secretome of UC-MSCs—comprising bioactive molecules such as exosomes, cytokines, and growth factors—offers a powerful, cell-free therapeutic option through paracrine signaling, further enhancing their therapeutic potential. A literature search was conducted in major databases (PubMed, ScienceDirect, SpringerLink, Google Scholar) for English articles from 2010–2025 using keywords related to UC‑MSCs and orthopedic regeneration. This review explores the role of UC-MSCs and their secretome in orthopedic tissue repair, focusing on their application in bone healing, cartilage regeneration, tendon-ligament repair, and nerve regeneration with their innovative delivery. Despite the promising potential of UC-MSC therapies, several challenges remain, including regulatory hurdles, long-term safety concerns, and the scalability of cell-based and secretome-based therapies for widespread clinical use. Although umbilical cord MSCs are not yet widely applied in clinical practice, increasing evidence suggests that they offer significant therapeutic potential, especially in the treatment of autoimmune and neurodegenerative diseases. The UC-MSCs and their secretome represent a transformative approach in orthopedics, offering new avenues for treating complex musculoskeletal injuries and degenerative diseases. Ongoing advancements in this field will likely unlock their full potential, making them viable options for clinical use in the near future.
- 22 April 2026
- Published by Universa Medicina in Universa Medicina
- Vol. 45 (1) , 135-152
Open AccessUmbilical cord mesenchymal stem cells and their secretome: a new frontier in orthopedic medicine
Umbilical cord mesenchymal stem cells (UC-MSCs) have gained significant attention in regenerative medicine due to their unique biological properties, including high proliferation capacity, low immunogenicity, and potent immunomodulatory effects. These characteristics make UC-MSCs particularly promising for orthopedic applications, where the repair and regeneration of musculoskeletal tissues such as bone, cartilage, tendons, ligaments, and nerves are critical for restoring function. The secretome of UC-MSCs—comprising bioactive molecules such as exosomes, cytokines, and growth factors—offers a powerful, cell-free therapeutic option through paracrine signaling, further enhancing their therapeutic potential. A literature search was conducted in major databases (PubMed, ScienceDirect, SpringerLink, Google Scholar) for English articles from 2010–2025 using keywords related to UC‑MSCs and orthopedic regeneration. This review explores the role of UC-MSCs and their secretome in orthopedic tissue repair, focusing on their application in bone healing, cartilage regeneration, tendon-ligament repair, and nerve regeneration with their innovative delivery. Despite the promising potential of UC-MSC therapies, several challenges remain, including regulatory hurdles, long-term safety concerns, and the scalability of cell-based and secretome-based therapies for widespread clinical use. Although umbilical cord MSCs are not yet widely applied in clinical practice, increasing evidence suggests that they offer significant therapeutic potential, especially in the treatment of autoimmune and neurodegenerative diseases. The UC-MSCs and their secretome represent a transformative approach in orthopedics, offering new avenues for treating complex musculoskeletal injuries and degenerative diseases. Ongoing advancements in this field will likely unlock their full potential, making them viable options for clinical use in the near future.
- Open Access
- 15 April 2026
- Published by Scientific Scholar in Journal of Musculoskeletal Surgery and Research
- p. 1-5
Finite element analysis of novel medial opening-wedge high tibial osteotomy plate: “High tibial osteotomy 7-plate”
Objectives: High tibial osteotomy (HTO) is a well-established surgical technique primarily employed to correct knee varus deformity and treat medial compartment osteoarthritis in the knee. However, traditional plate designs used for HTO often encounter challenges, particularly when HTO is combined with anterior cruciate ligament reconstruction, where the traditional plate usually has limited bone space for graft fixation. Methods: This study evaluates the mechanical behavior of a novel HTO 7-plate implant through comprehensive finite element analysis. The investigation was conducted under two primary physiological loading conditions: Axial (tensile) and compression. The simulation meticulously analyzed key mechanical parameters, including displacement, strain, and von Mises stress, under varying applied forces of 250 N, 500 N, and 750 N. Results: The consistent results demonstrated that all calculated stress values remained significantly below the approximately 300 MPa yield strength of SS316L stainless steel. Conclusion: This study’s findings indicate that the novel implant design is mechanically safe and robust under the simulated physiological loading scenarios, suggesting its potential for reliable clinical application.
- 15 April 2026
- Published by Scientific Scholar in Journal of Musculoskeletal Surgery and Research
- p. 1-5
Open AccessFinite element analysis of novel medial opening-wedge high tibial osteotomy plate: “High tibial osteotomy 7-plate”
Objectives: High tibial osteotomy (HTO) is a well-established surgical technique primarily employed to correct knee varus deformity and treat medial compartment osteoarthritis in the knee. However, traditional plate designs used for HTO often encounter challenges, particularly when HTO is combined with anterior cruciate ligament reconstruction, where the traditional plate usually has limited bone space for graft fixation. Methods: This study evaluates the mechanical behavior of a novel HTO 7-plate implant through comprehensive finite element analysis. The investigation was conducted under two primary physiological loading conditions: Axial (tensile) and compression. The simulation meticulously analyzed key mechanical parameters, including displacement, strain, and von Mises stress, under varying applied forces of 250 N, 500 N, and 750 N. Results: The consistent results demonstrated that all calculated stress values remained significantly below the approximately 300 MPa yield strength of SS316L stainless steel. Conclusion: This study’s findings indicate that the novel implant design is mechanically safe and robust under the simulated physiological loading scenarios, suggesting its potential for reliable clinical application.
- Open Access
- 1 April 2026
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 138 (5) , 1905-1909
Acute shortening and re-lengthening (ASRL) procedure combined with RhBMP-2 to treat femur non-union with leg length discrepancy: a case report
Background: Femoral shaft non-union complicated by leg length discrepancy (LLD) and segmental bone loss remains a significant reconstructive challenge. Conventional bone transport techniques may involve long external fixation times, multiple surgeries, and soft-tissue morbidity. The acute shortening and re-lengthening (ASRL) method offers an alternative by achieving immediate bone contact and tissue closure, followed by gradual restoration of length. The adjunctive use of recombinant human bone morphogenetic protein-2 (rhBMP-2) may enhance osteogenesis at the docking and regenerate sites. Case presentation: We present a 24-year-old male patient with a femoral non-union and a 6 cm leg length discrepancy following multiple failed surgeries and hardware removal. The operative strategy comprised thorough debridement of the non-union site, acute shortening of the femur for direct end-to-end contact, application of rhBMP-2 at the docking interface, and placement of a monorail external fixator. A proximal femoral corticotomy was then performed for gradual distraction at 1 mm/day after a 10-day latency. Full-length restoration, radiographic union, and pain-free weight-bearing were achieved at 12 months. No major complications occurred. Clinical discussion: The ASRL technique, combined with rhBMP-2 on docking site, may represent a viable biomechanical-biological strategy for complex femoral non-union with LLD. Conclusions: The combined mechanical-biological strategy of ASRL with rhBMP-2 augmentation at docking site may offer a viable method for addressing femoral shaft non-union with leg length discrepancy.
- 1 April 2026
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 138 (5) , 1905-1909
Open AccessAcute shortening and re-lengthening (ASRL) procedure combined with RhBMP-2 to treat femur non-union with leg length discrepancy: a case report
Background: Femoral shaft non-union complicated by leg length discrepancy (LLD) and segmental bone loss remains a significant reconstructive challenge. Conventional bone transport techniques may involve long external fixation times, multiple surgeries, and soft-tissue morbidity. The acute shortening and re-lengthening (ASRL) method offers an alternative by achieving immediate bone contact and tissue closure, followed by gradual restoration of length. The adjunctive use of recombinant human bone morphogenetic protein-2 (rhBMP-2) may enhance osteogenesis at the docking and regenerate sites. Case presentation: We present a 24-year-old male patient with a femoral non-union and a 6 cm leg length discrepancy following multiple failed surgeries and hardware removal. The operative strategy comprised thorough debridement of the non-union site, acute shortening of the femur for direct end-to-end contact, application of rhBMP-2 at the docking interface, and placement of a monorail external fixator. A proximal femoral corticotomy was then performed for gradual distraction at 1 mm/day after a 10-day latency. Full-length restoration, radiographic union, and pain-free weight-bearing were achieved at 12 months. No major complications occurred. Clinical discussion: The ASRL technique, combined with rhBMP-2 on docking site, may represent a viable biomechanical-biological strategy for complex femoral non-union with LLD. Conclusions: The combined mechanical-biological strategy of ASRL with rhBMP-2 augmentation at docking site may offer a viable method for addressing femoral shaft non-union with leg length discrepancy.
- 3 May 2025
- Published by Springer Nature
- p. 2465-2473
Return to Sport After Total Knee Arthroplasty
- 5 August 2024
- Published by Springer Nature
- p. 1-9
Return to Sport After Total Knee Arthroplasty
- Open Access
- 27 August 2023
- Published by Indonesian Hip and Knee Society in The Hip and Knee Journal
- Vol. 4 (2) , 48-50
High Tibial Osteotomy for knee joint preservation: “Old but Gold”!
One of the most common chronic diseases affecting the elderly is knee osteoarthritis (OA) that significantly impairs the activity of the daily living. Change of mechanical axis of the knee causes impairment on the three compartments of knee. If the medial compartment is affected, it will cause varus knee deformity, whereas, involvement of lateral compartment will result in valgus knee deformity. Deformities of angular and/or rotational nature can be corrected using the knee osteotomy technique, consequently realigning the bone axis.The osteotomy technique has been developed for centuries. Current growing interest in developing minimally invasive techniques for high tibial osteotomy (HTO) using smaller incisions, arthroscopy-assisted osteotomy, patients specific instrumentation (PSI) and computer-guided navigations systems. These techniques aim to reduce surgical trauma, minimize scarring, and facilitate faster recovery.
- 27 August 2023
- Published by Indonesian Hip and Knee Society in The Hip and Knee Journal
- Vol. 4 (2) , 48-50
Open AccessHigh Tibial Osteotomy for knee joint preservation: “Old but Gold”!
One of the most common chronic diseases affecting the elderly is knee osteoarthritis (OA) that significantly impairs the activity of the daily living. Change of mechanical axis of the knee causes impairment on the three compartments of knee. If the medial compartment is affected, it will cause varus knee deformity, whereas, involvement of lateral compartment will result in valgus knee deformity. Deformities of angular and/or rotational nature can be corrected using the knee osteotomy technique, consequently realigning the bone axis.The osteotomy technique has been developed for centuries. Current growing interest in developing minimally invasive techniques for high tibial osteotomy (HTO) using smaller incisions, arthroscopy-assisted osteotomy, patients specific instrumentation (PSI) and computer-guided navigations systems. These techniques aim to reduce surgical trauma, minimize scarring, and facilitate faster recovery.
- Open Access
- 17 June 2023
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 85 (7) , 3339-3346
The use of bovine-derived hydroxyapatite xenograft for defect filling in opening-wedge high tibial osteotomy
Introduction: High tibial osteotomy is a reliable procedure for the correction of knee varus deformity. An opening-wedge high tibial osteotomy (OW-HTO) is the most popular technique. The results of the bone defect after opening the wedge needed special treatment to ensure bone healing. This study aims to evaluate the use of bovine-derived hydroxyapatite graft for defect filling after OW-HTO. Methods: A retrospective study was performed on all patients who received OW-HTO at Prof. Dr R. Soeharso Orthopaedic Hospital from November 2019 to December 2022. A total of 21 patients (24 knees) were included in this study. Clinical dan radiological evaluation was performed on all patients preoperative and postoperatively. The mean of the follow-up period was 12.6 months with a minimum of 4 months follow-up. Results: Primary medial uni-compartment knee osteoarthritis was the most common diagnosis, with 17 of 24 cases (70.8%). Mechanical axis deviation was changed from 31 mm medial deviation (range: 8–52 mm) to 0.45 mm medial deviation (range: 13 - (-8) mm). The anatomic tibiofemoral angle was corrected from a preoperative mean of 4.7° of varus to a mean of 5.8° of valgus postoperatively. Bone defect height was mean 15.9 mm with a range of 10–23 mm. Bone defect width was mean 46.7 mm (range: 34–60 mm). Hydroxyapatite graft integration with the host bone was found in all patients during the final follow-up period. Conclusions: Bovine-derived hydroxyapatite graft is a safe and effective material for bone defect filling in OW-HTO procedures with a high bone union rate.
- 17 June 2023
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 85 (7) , 3339-3346
Open AccessThe use of bovine-derived hydroxyapatite xenograft for defect filling in opening-wedge high tibial osteotomy
Introduction: High tibial osteotomy is a reliable procedure for the correction of knee varus deformity. An opening-wedge high tibial osteotomy (OW-HTO) is the most popular technique. The results of the bone defect after opening the wedge needed special treatment to ensure bone healing. This study aims to evaluate the use of bovine-derived hydroxyapatite graft for defect filling after OW-HTO. Methods: A retrospective study was performed on all patients who received OW-HTO at Prof. Dr R. Soeharso Orthopaedic Hospital from November 2019 to December 2022. A total of 21 patients (24 knees) were included in this study. Clinical dan radiological evaluation was performed on all patients preoperative and postoperatively. The mean of the follow-up period was 12.6 months with a minimum of 4 months follow-up. Results: Primary medial uni-compartment knee osteoarthritis was the most common diagnosis, with 17 of 24 cases (70.8%). Mechanical axis deviation was changed from 31 mm medial deviation (range: 8–52 mm) to 0.45 mm medial deviation (range: 13 - (-8) mm). The anatomic tibiofemoral angle was corrected from a preoperative mean of 4.7° of varus to a mean of 5.8° of valgus postoperatively. Bone defect height was mean 15.9 mm with a range of 10–23 mm. Bone defect width was mean 46.7 mm (range: 34–60 mm). Hydroxyapatite graft integration with the host bone was found in all patients during the final follow-up period. Conclusions: Bovine-derived hydroxyapatite graft is a safe and effective material for bone defect filling in OW-HTO procedures with a high bone union rate.
- Open Access
- 1 June 2023
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 107 (C) , 108361
Asymmetric bilateral traumatic hip dislocation
Introduction and importance: Asymmetric bilateral hip dislocation is an extremely rare condition. The mechanism of injury and severity are variables. We reported two cases of asymmetric bilateral hip dislocation with different pattern of injury and different onset of injury. Case presentation: The first case was a male 20 years old with 7 months neglected asymmetric bilateral hip dislocation. Total hip arthroplasty (THA) was performed on both hips, which resulted in good clinical outcomes. The second case was a male 32 years old with acute right open anterior dislocation (obturator type) and left posterior fracture-dislocation. Emergency debridement and open reduction were performed on the patients with reduction and fixation for the left hip. Clinical case discussion: To the best of our knowledge, this is the first reported case of open anterior hip dislocation with exposed femoral head on inguinal area in the setting of asymmetric bilateral hip dislocation. Furthermore, this article also presented another case with >6 months neglected time along with the surgical treatment. Conclusions: Asymmetric bilateral hip dislocation is a rare injury which usually associated with high-energy trauma. Open injury with the exposed femoral head is possible to occur in this kind of rare case. In the setting of long-term neglected cases, total hip arthroplasty could be recommended as the treatment choice. Highlights:
- 1 June 2023
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 107 (C) , 108361
Open AccessAsymmetric bilateral traumatic hip dislocation
Introduction and importance: Asymmetric bilateral hip dislocation is an extremely rare condition. The mechanism of injury and severity are variables. We reported two cases of asymmetric bilateral hip dislocation with different pattern of injury and different onset of injury. Case presentation: The first case was a male 20 years old with 7 months neglected asymmetric bilateral hip dislocation. Total hip arthroplasty (THA) was performed on both hips, which resulted in good clinical outcomes. The second case was a male 32 years old with acute right open anterior dislocation (obturator type) and left posterior fracture-dislocation. Emergency debridement and open reduction were performed on the patients with reduction and fixation for the left hip. Clinical case discussion: To the best of our knowledge, this is the first reported case of open anterior hip dislocation with exposed femoral head on inguinal area in the setting of asymmetric bilateral hip dislocation. Furthermore, this article also presented another case with >6 months neglected time along with the surgical treatment. Conclusions: Asymmetric bilateral hip dislocation is a rare injury which usually associated with high-energy trauma. Open injury with the exposed femoral head is possible to occur in this kind of rare case. In the setting of long-term neglected cases, total hip arthroplasty could be recommended as the treatment choice. Highlights: