PAParastoo Alinia

Parastoo Alinia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Parastoo Alinia has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Model-Agnostic Structural Transfer Learning for Cross-Domain Autonomous Activity Recognition

    by Parastoo Alinia, Asiful Arefeen, Zhila Esna Ashari, Seyed Iman Mirzadeh, Hassan Ghasemzadeh

    Activity recognition using data collected with smart devices such as mobile and wearable sensors has become a critical component of many emerging applications ranging from behavioral medicine to gaming. However, an unprecedented increase in the diversity of smart devices in the internet-of-things era has limited the adoption of activity recognition models for use across different devices. This lack of cross-domain adaptation is particularly notable across sensors of different modalities where the mapping of the sensor data in the traditional feature level is highly challenging. To address this challenge, we propose ActiLabel, a combinatorial framework that learns structural similarities among the events that occur in a target domain and those of a source domain and identifies an optimal mapping between the two domains at their structural level. The structural similarities are captured through a graph model, referred to as the dependency graph, which abstracts details of activity patterns in low-level signal and feature space. The activity labels are then autonomously learned in the target domain by finding an optimal tiered mapping between the dependency graphs. We carry out an extensive set of experiments on three large datasets collected with wearable sensors involving human subjects. The results demonstrate the superiority of ActiLabel over state-of-the-art transfer learning and deep learning methods. In particular, ActiLabel outperforms such algorithms by average F1-scores of 36.3%, 32.7%, and 9.1% for cross-modality, cross-location, and cross-subject activity recognition, respectively.


  • Open Access

    Associations Between Physiological Signals Captured Using Wearable Sensors and Self-reported Outcomes Among Adults in Alcohol Use Disorder Recovery: Development and Usability Study

    by Parastoo Alinia, Ramesh Kumar Sah, Michael McDonell, Patricia Pendry, Sara Parent, Hassan Ghasemzadeh, Michael John Cleveland

    Background: Previous research has highlighted the role of stress in substance misuse and addiction, particularly for relapse risk. Mobile health interventions that incorporate real-time monitoring of physiological markers of stress offer promise for delivering tailored interventions to individuals during high-risk states of heightened stress to prevent alcohol relapse. Before such interventions can be developed, measurements of these processes in ambulatory, real-world settings are needed. Objective: This research is a proof-of-concept study to establish the feasibility of using a wearable sensor device to continuously monitor stress in an ambulatory setting. Toward that end, we first aimed to examine the quality of 2 continuously monitored physiological signals—electrodermal activity (EDA) and heart rate variability (HRV)—and show that the data follow standard quality measures according to the literature. Next, we examined the associations between the statistical features extracted from the EDA and HRV signals and self-reported outcomes. Methods: Participants (N=11; female: n=10) were asked to wear an Empatica E4 wearable sensor for continuous unobtrusive physiological signal collection for up to 14 days. During the same time frame, participants responded to a daily diary study using ecological momentary assessment of self-reported stress, emotions, alcohol-related cravings, pain, and discomfort via a web-based survey, which was conducted 4 times daily. Participants also participated in structured interviews throughout the study to assess daily alcohol use and to validate self-reported and physiological stress markers. In the analysis, we first used existing artifact detection methods and physiological signal processing approaches to assess the quality of the physiological data. Next, we examined the descriptive statistics for self-reported outcomes. Finally, we investigated the associations between the features of physiological signals and self-reported outcomes. Results: We determined that 87.86% (1,032,265/1,174,898) of the EDA signals were clean. A comparison of the frequency of skin conductance responses per minute with previous research confirmed that the physiological signals collected in the ambulatory setting were successful. The results also indicated that the statistical features of the EDA and HRV measures were significantly correlated with the self-reported outcomes, including the number of stressful events marked on the sensor device, positive and negative emotions, and experienced pain and discomfort. Conclusions: The results demonstrated that the physiological data collected via an Empatica E4 wearable sensor device were consistent with previous literature in terms of the quality of the data and that features of these physiological signals were significantly associated with several self-reported outcomes among a sample of adults diagnosed with alcohol use disorder. These results suggest that ambulatory assessment of stress is feasible and can be used to develop tailored mobile health interventions to enhance sustained recovery from alcohol use disorder.


  • Personalized Activity Recognition Using Partially Available Target Data

    by Ramin Fallahzadeh, Zhila Esna Ashari, Parastoo Alinia, Hassan Ghasemzadeh

    Recent years have witnessed a growing body of research on autonomous activity recognition models for use in deployment of mobile systems in new settings such as when a wearable system is adopted by a new user. Current research, however, lacks comprehensive frameworks for transfer learning. Specifically, it lacks the ability to deal with partially available data in new settings. To address these limitations, we propose OptiMapper , a novel uninformed cross-subject transfer learning framework for activity recognition. OptiMapper is a combinatorial optimization framework that extracts abstract knowledge across subjects and utilizes this knowledge for developing a personalized and accurate activity recognition model in new subjects. To this end, a novel community-detection-based clustering of unlabeled data is proposed that uses the target user data to construct a network of unannotated sensor observations. The clusters of these target observations are then mapped onto the source clusters using a complete bipartite graph model. In the next step, the mapped labels are conditionally fused with the prediction of a base learner to create a personalized and labeled training dataset for the target user. We present two instantiations of OptiMapper. The first instantiation, which is applicable for transfer learning across domains with identical activity labels, performs a one-to-one bipartite mapping between clusters of the source and target users. The second instantiation performs optimal many-to-one mapping between the source clusters and those of the target. The many-to-one mapping allows us to find an optimal mapping even when the target dataset does not contain sufficient instances of all activity classes. We show that this type of cross-domain mapping can be formulated as a transportation problem and solved optimally. We evaluate our transfer learning techniques on several activity recognition datasets. Our results show that the proposed community detection approach can achieve, on average, 69 percent utilization of the datasets for clustering with an overall clustering accuracy of 87.5 percent. Our results also suggest that the proposed transfer learning algorithms can achieve up to 22.5 percent improvement in the activity recognition accuracy, compared to the state-of-the-art techniques. The experimental results also demonstrate high and sustained performance even in presence of partial data.


  • Open Access

    Associations Between Physiological Signals Captured Using Wearable Sensors and Self-reported Outcomes Among Adults in Alcohol Use Disorder Recovery: Development and Usability Study (Preprint)

    by Parastoo Alinia, Ramesh Kumar Sah, Michael McDonell, Patricia Pendry, Sara Parent, Hassan Ghasemzadeh, Michael John Cleveland

    BACKGROUND Previous research has highlighted the role of stress in substance misuse and addiction, particularly for relapse risk. Mobile health interventions that incorporate real-time monitoring of physiological markers of stress offer promise for delivering tailored interventions to individuals during high-risk states of heightened stress to prevent alcohol relapse. Before such interventions can be developed, measurements of these processes in ambulatory, real-world settings are needed. OBJECTIVE This research is a proof-of-concept study to establish the feasibility of using a wearable sensor device to continuously monitor stress in an ambulatory setting. Toward that end, we first aimed to examine the quality of 2 continuously monitored physiological signals—electrodermal activity (EDA) and heart rate variability (HRV)—and show that the data follow standard quality measures according to the literature. Next, we examined the associations between the statistical features extracted from the EDA and HRV signals and self-reported outcomes. METHODS Participants (N=11; female: n=10) were asked to wear an Empatica E4 wearable sensor for continuous unobtrusive physiological signal collection for up to 14 days. During the same time frame, participants responded to a daily diary study using ecological momentary assessment of self-reported stress, emotions, alcohol-related cravings, pain, and discomfort via a web-based survey, which was conducted 4 times daily. Participants also participated in structured interviews throughout the study to assess daily alcohol use and to validate self-reported and physiological stress markers. In the analysis, we first used existing artifact detection methods and physiological signal processing approaches to assess the quality of the physiological data. Next, we examined the descriptive statistics for self-reported outcomes. Finally, we investigated the associations between the features of physiological signals and self-reported outcomes. RESULTS We determined that 87.86% (1,032,265/1,174,898) of the EDA signals were clean. A comparison of the frequency of skin conductance responses per minute with previous research confirmed that the physiological signals collected in the ambulatory setting were successful. The results also indicated that the statistical features of the EDA and HRV measures were significantly correlated with the self-reported outcomes, including the number of stressful events marked on the sensor device, positive and negative emotions, and experienced pain and discomfort. CONCLUSIONS The results demonstrated that the physiological data collected via an Empatica E4 wearable sensor device were consistent with previous literature in terms of the quality of the data and that features of these physiological signals were significantly associated with several self-reported outcomes among a sample of adults diagnosed with alcohol use disorder. These results suggest that ambulatory assessment of stress is feasible and can be used to develop tailored mobile health interventions to enhance sustained recovery from alcohol use disorder.

  • Open Access

    Pervasive Lying Posture Tracking

    by Parastoo Alinia, Ali Samadani, Mladen Milosevic, Hassan Ghasemzadeh, Saman Parvaneh

    Automated lying-posture tracking is important in preventing bed-related disorders, such as pressure injuries, sleep apnea, and lower-back pain. Prior research studied in-bed lying posture tracking using sensors of different modalities (e.g., accelerometer and pressure sensors). However, there remain significant gaps in research regarding how to design efficient in-bed lying posture tracking systems. These gaps can be articulated through several research questions, as follows. First, can we design a single-sensor, pervasive, and inexpensive system that can accurately detect lying postures? Second, what computational models are most effective in the accurate detection of lying postures? Finally, what physical configuration of the sensor system is most effective for lying posture tracking? To answer these important research questions, in this article we propose a comprehensive approach for designing a sensor system that uses a single accelerometer along with machine learning algorithms for in-bed lying posture classification. We design two categories of machine learning algorithms based on deep learning and traditional classification with handcrafted features to detect lying postures. We also investigate what wearing sites are the most effective in the accurate detection of lying postures. We extensively evaluate the performance of the proposed algorithms on nine different body locations and four human lying postures using two datasets. Our results show that a system with a single accelerometer can be used with either deep learning or traditional classifiers to accurately detect lying postures. The best models in our approach achieve an F1 score that ranges from 95.2% to 97.8% with a coefficient of variation from 0.03 to 0.05. The results also identify the thighs and chest as the most salient body sites for lying posture tracking. Our findings in this article suggest that, because accelerometers are ubiquitous and inexpensive sensors, they can be a viable source of information for pervasive monitoring of in-bed postures.


  • ParaLabel: Autonomous Parameter Learning for Cross-Domain Step Counting in Wearable Sensors

    by Parastoo Alinia, Ramin Fallahzadeh, Christopher P. Connolly, Hassan Ghasemzadeh

    Wearable step counters, also referred to as activity trackers, have been developed for health and activity monitoring, as well as for step tracking. These trackers, however, produce unreliable measurements during slow walking and when walking with assistive devices (i.e., aided walking). To address this challenge, in this article, we introduce, ParaLabel , a filter-based step counting algorithm that is reliable against various walking velocities and intensities. ParaLabel addresses this problem by learning a filter cut-off frequency autonomously in a new domain without the need for collecting sensor data and manually tuning the algorithm parameter for a different velocity and/or pattern of walking. We formulate this problem as a transfer learning problem in which the new filter cut-off frequency is transferred from a bank containing previously fine-tuned parameters from different domain(s). Our extensive analysis using real data collected from 15 participants while wearing an accelerometer sensor on their chest, wrist, or left pocket demonstrates the superiority of ParaLabel to two commercially available trackers worn on the same body location, and state-of-the-art techniques. ParaLabel achieves 96.3% − 99.9% accuracy during walking on a treadmill at three different velocities, 98.2% − 99.9% accuracy during walking with a shopping cart, and 89.3% − 97.3% accuracy while walking with the aid of a walker.


  • Open Access

    ActiLabel: A Combinatorial Transfer Learning Framework for Activity Recognition

    by Parastoo Alinia, Iman Mirzadeh, Hassan Ghasemzadeh

    Sensor-based human activity recognition has become a critical component of many emerging applications ranging from behavioral medicine to gaming. However, an unprecedented increase in the diversity of sensor devices in the Internet-of-Things era has limited the adoption of activity recognition models for use across different domains. We propose ActiLabel a combinatorial framework that learns structural similarities among the events in an arbitrary domain and those of a different domain. The structural similarities are captured through a graph model, referred to as the it dependency graph, which abstracts details of activity patterns in low-level signal and feature space. The activity labels are then autonomously learned by finding an optimal tiered mapping between the dependency graphs. Extensive experiments based on three public datasets demonstrate the superiority of ActiLabel over state-of-the-art transfer learning and deep learning methods.

  • Open Access

    How Accurate Is Your Activity Tracker? A Comparative Study of Step Counts in Low-Intensity Physical Activities

    by Parastoo Alinia, Chris Cain, Ramin Fallahzadeh, Armin Shahrokni, Diane Cook, Hassan Ghasemzadeh

    Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.