Jong-Ho Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jong-Ho Park has a total of 184 co-authors. Here are the top co-authors by number of shared publications:
Kyuseok Song
9 shared publicationsKahee Jeong
Korea Atom Energy Res Inst, Nucl Chem Res Div, 111 Daedeok Daero 989, Daejeon 34057, South Korea
4 shared publicationsKyu-Seok Song
4 shared publicationsMario J. Molina
Department of Chemistry and Biochemistry University of California‐San Diego La Jolla CA 92093 USA
4 shared publicationsChi-Gyu Lee
Korea Atomic Energy Research Institute
3 shared publicationsJung Woo Shin
3 shared publications
Latest Publications
- Open Access
- 24 August 2026
- Published by Springer Nature in Journal of Analytical Science and Technology
- Vol. 17 (1) , 47
Isotopic analysis of ultra-trace Cu using TIMS with the continuous heating method: optimization of the data integration range and method
- 24 August 2026
- Published by Springer Nature in Journal of Analytical Science and Technology
- Vol. 17 (1) , 47
Open AccessIsotopic analysis of ultra-trace Cu using TIMS with the continuous heating method: optimization of the data integration range and method
- 10 February 2026
- Published by Wiley in Bulletin of the Korean Chemical Society
- Vol. 47 (3) , 361-369
Optimization of data integration for ultra‐trace zinc isotope ratio analysis by continuous heating thermal ionization mass spectrometry with single‐collector sequential detection
The thermal ionization mass spectrometry (TIMS) coupled with the continuous heating method was applied to the isotopic analysis of Zn at an ultra‐trace level (1 ng) using the certified reference material IRMM‐3702. Because nanogram‐level Zn produces weak ion signals that require single secondary electron multiplier (SEM) sequential detection, a detailed evaluation of data treatment procedures was carried out to secure high analytical performance. Three integration methods (summed intensities, simple averaging, and intensity‐weighted averaging) were experimentally evaluated for four integration ranges defined relative to the maximum 64 Zn + intensity (full, “over 1%”, “over 25%”, and “over 75%”). The results showed that the analytical performance (accuracy, precision, and uncertainty) is strongly affected by both the integration method and the integration range. Method I (summed intensities) and Method III (intensity‐weighted averaging) produced isotope ratios with relatively high precision and acceptable accuracy, while Method III showed slightly better analytical performance compared to Method I. Method II (simple averaging) produced large deviations and poor precision when applied to the full range, although the analytical performance improved when reduced integration ranges were applied. These findings indicate that the optimized data treatment procedure for the continuous heating TIMS analysis of Zn isotopes is the use of Method I or III with the integration ranges of “over 25%”, as they yield comparable analytical performance in this range. The results establish a methodological procedure for accurate and precise Zn isotope ratio measurements at ultra‐trace levels, extending the applicability of TIMS as a competitive tool for geochemical, environmental, and biomedical research.
- 10 February 2026
- Published by Wiley in Bulletin of the Korean Chemical Society
- Vol. 47 (3) , 361-369
Optimization of data integration for ultra‐trace zinc isotope ratio analysis by continuous heating thermal ionization mass spectrometry with single‐collector sequential detection
The thermal ionization mass spectrometry (TIMS) coupled with the continuous heating method was applied to the isotopic analysis of Zn at an ultra‐trace level (1 ng) using the certified reference material IRMM‐3702. Because nanogram‐level Zn produces weak ion signals that require single secondary electron multiplier (SEM) sequential detection, a detailed evaluation of data treatment procedures was carried out to secure high analytical performance. Three integration methods (summed intensities, simple averaging, and intensity‐weighted averaging) were experimentally evaluated for four integration ranges defined relative to the maximum 64 Zn + intensity (full, “over 1%”, “over 25%”, and “over 75%”). The results showed that the analytical performance (accuracy, precision, and uncertainty) is strongly affected by both the integration method and the integration range. Method I (summed intensities) and Method III (intensity‐weighted averaging) produced isotope ratios with relatively high precision and acceptable accuracy, while Method III showed slightly better analytical performance compared to Method I. Method II (simple averaging) produced large deviations and poor precision when applied to the full range, although the analytical performance improved when reduced integration ranges were applied. These findings indicate that the optimized data treatment procedure for the continuous heating TIMS analysis of Zn isotopes is the use of Method I or III with the integration ranges of “over 25%”, as they yield comparable analytical performance in this range. The results establish a methodological procedure for accurate and precise Zn isotope ratio measurements at ultra‐trace levels, extending the applicability of TIMS as a competitive tool for geochemical, environmental, and biomedical research.
- 7 December 2023
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 35 (1) , 158-165
Isotopic Analysis of Lead at Ultratrace Levels Using Thermal Ionization Mass Spectrometry (TIMS) Coupled with the Continuous Heating Method: Optimization of the Data Integration Range and Method
This study systematically and experimentally evaluates data integration methods for the isotopic analysis of Pb at ultratrace levels using thermal ionization mass spectrometry (TIMS) with a continuous heating method. The evaluation utilized a certified reference material of Pb (SRM 981). The experimental evaluations encompass different data calculation methods (methods I, II, and III) and integration ranges (full, over 1%, 25%, and 75%). Method I, in which isotope ratios were calculated based on summed ion signal intensities compensating for mass fractionation, was consistent with the certified values for 10 and 1 ng standard samples across all integration ranges. For 100 pg samples, full range calculations failed for specific isotope ratios, but reduced ranges (over 1%, 25%, and 75%) yielded values overlapping with certified ones. Method II, in which isotope ratios were calculated by averaging the precalculated isotope ratios, exhibited inferior performance compared to method I. Method III, using weighted averaging to reduce anomalous values, showed results consistent with those of method I but was recommended only for single measurements. An integration range of over 1% or 25% is preferred to exclude anomalies while compensating for mass fractionation. The optimized method was validated by comparing two different instruments used for the isotopic analysis of the reference material. The enhanced accuracy and precision provide valuable insights for researchers working in ultratrace-level Pb isotopic analysis using TIMS.
- 7 December 2023
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 35 (1) , 158-165
Isotopic Analysis of Lead at Ultratrace Levels Using Thermal Ionization Mass Spectrometry (TIMS) Coupled with the Continuous Heating Method: Optimization of the Data Integration Range and Method
This study systematically and experimentally evaluates data integration methods for the isotopic analysis of Pb at ultratrace levels using thermal ionization mass spectrometry (TIMS) with a continuous heating method. The evaluation utilized a certified reference material of Pb (SRM 981). The experimental evaluations encompass different data calculation methods (methods I, II, and III) and integration ranges (full, over 1%, 25%, and 75%). Method I, in which isotope ratios were calculated based on summed ion signal intensities compensating for mass fractionation, was consistent with the certified values for 10 and 1 ng standard samples across all integration ranges. For 100 pg samples, full range calculations failed for specific isotope ratios, but reduced ranges (over 1%, 25%, and 75%) yielded values overlapping with certified ones. Method II, in which isotope ratios were calculated by averaging the precalculated isotope ratios, exhibited inferior performance compared to method I. Method III, using weighted averaging to reduce anomalous values, showed results consistent with those of method I but was recommended only for single measurements. An integration range of over 1% or 25% is preferred to exclude anomalies while compensating for mass fractionation. The optimized method was validated by comparing two different instruments used for the isotopic analysis of the reference material. The enhanced accuracy and precision provide valuable insights for researchers working in ultratrace-level Pb isotopic analysis using TIMS.
- Open Access
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 03017
Experimental investigation on the thermal performance of a domestic gas boiler for space heating with different heating load ratio
This study explores the effects of heating demand and hot water temperature on energy efficiency in a domestic gas boiler (DGB). Mock-up experiments were conducted using two types of boilers with different capacities (i.e., 11.6 kW and 23.3 kW of non-condensing boilers, 16.3 kW of condensing boiler) for comparative analysis. As results, for space heating, the efficiencies of non-condensing boilers (i.e., 11.6 kW and 23.3 kW) and condensing boiler (i.e., 16.3 kW) decreased by 12-44%, 15-46%, and 2-22% respectively as the heating load ratios were changed from 100%-25%. When the supply hot water temperature settings decreased from 55℃ to 45℃, the efficiencies were reduced by 13.6% (11.6 kW) and 53.3% (23.3 kW). For the condensing boiler, an efficiency reduction rate was 16.7% as the hot water temperatures dropped from 45℃ to 35℃. Also, since the boiler capacity depends on domestic hot water (DHW) load, the daily heating demands of space heating and DHW load were analyzed. In the results, reducing the lower limit of heating output could be more effective in improving the boiler efficiency for space heating. To provide sufficient DHW demand, it is required to maintain the upper limit of the heating output.
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 03017
Open AccessExperimental investigation on the thermal performance of a domestic gas boiler for space heating with different heating load ratio
This study explores the effects of heating demand and hot water temperature on energy efficiency in a domestic gas boiler (DGB). Mock-up experiments were conducted using two types of boilers with different capacities (i.e., 11.6 kW and 23.3 kW of non-condensing boilers, 16.3 kW of condensing boiler) for comparative analysis. As results, for space heating, the efficiencies of non-condensing boilers (i.e., 11.6 kW and 23.3 kW) and condensing boiler (i.e., 16.3 kW) decreased by 12-44%, 15-46%, and 2-22% respectively as the heating load ratios were changed from 100%-25%. When the supply hot water temperature settings decreased from 55℃ to 45℃, the efficiencies were reduced by 13.6% (11.6 kW) and 53.3% (23.3 kW). For the condensing boiler, an efficiency reduction rate was 16.7% as the hot water temperatures dropped from 45℃ to 35℃. Also, since the boiler capacity depends on domestic hot water (DHW) load, the daily heating demands of space heating and DHW load were analyzed. In the results, reducing the lower limit of heating output could be more effective in improving the boiler efficiency for space heating. To provide sufficient DHW demand, it is required to maintain the upper limit of the heating output.
- 9 January 2022
- Published by Springer Nature in Korean Journal of Chemical Engineering
- Vol. 39 (3) , 684-694
Cellulose-type binder enabling CuCl2 supported on nanoporous bayerite to have high CO adsorption ability via reduction of Cu2+ to Cu+
- 9 January 2022
- Published by Springer Nature in Korean Journal of Chemical Engineering
- Vol. 39 (3) , 684-694
Cellulose-type binder enabling CuCl2 supported on nanoporous bayerite to have high CO adsorption ability via reduction of Cu2+ to Cu+
- Open Access
- 1 October 2021
- Published by Elsevier in Microchemical Journal
- Vol. 169
Review of the development in determination of 129I amount and the isotope ratio of 129I/127I using mass spectrometric measurements
- 1 October 2021
- Published by Elsevier in Microchemical Journal
- Vol. 169
Open AccessReview of the development in determination of 129I amount and the isotope ratio of 129I/127I using mass spectrometric measurements
- Open Access
- 30 September 2021
- Published by The Korea Academia-Industrial Cooperation Society in Journal of the Korea Academia-Industrial cooperation Society
- Vol. 22 (9) , 575-587
Development of a Simulation Model for Managing High-Risk Drinking Rates to Improve the Health Level of Local Communities
본 연구의 목적은 생태학적 방법론에 근거한 분석결과를 기반으로 다양한 대안의 효과를 예측할 수 있는 고위험 음주율 관리 시뮬레이션 모형을 개발하는 것이다. 이를 위해 생태학적인 분석에 적합한 지표 데이터를 2019년 지역사회 건강조사, 통계청 지표를 수집하였다. 고위험음주율의 지역 간 변이 및 관련 요인을 파악하기 위해 SPSS Statistics 23을 이용하여 기술통계, 상관분석, 다중회귀분석을 실시하였으며, 지역별 영향을 미치는 요인을 파악하기 위해 Arc GIS를 이용하여 지리적 가중회귀분석, SAS Enterprise Miner 9.4를 이용하여 대화식 의사결정나무를 실시하였다. 고위험 음주율에 영향을 미치는 요인으로 현재흡연율, 인당 상업지역면적, 비만율, 우울감 경험률이 높을수록, 인당 공원면적, 중등도 이상 신체활동 실천율이 낮을수록 고위험음주율이 높은 것으로 분석되었다. 이러한 결과를 기반으로 국가차원에서 시뮬레이션 하는 것을 지원하기 위해 다중회귀분석을 이용하여 모형을 개발하였고, 시‧군‧구 단위의 시뮬레이션을 지원하기 위해지리적 가중회귀분석을 이용하여 모형을 개발하였다. 또한, 실제 개선할 수 있는 요인을 중심으로 시뮬레이션이 가능하도록 대화식 의사결정나무 분석을 통해 모형을 개발하였고, 유형1 그룹이 총228개 지역의 고위험음주율에 비해 음주할 확률이 1.5배 정도 높은 것으로 나타났다. 본 연구의 결과는 지역사회 고위험음주율 관리를 통해 건강수준이 개선됨과 동시에 사업 효과를 증대시킬 수 있으며, 추후 지역사회 건강증진사업 수립에 손쉽게 활용될 것으로 기대된다.
- 30 September 2021
- Published by The Korea Academia-Industrial Cooperation Society in Journal of the Korea Academia-Industrial cooperation Society
- Vol. 22 (9) , 575-587
Open AccessDevelopment of a Simulation Model for Managing High-Risk Drinking Rates to Improve the Health Level of Local Communities
본 연구의 목적은 생태학적 방법론에 근거한 분석결과를 기반으로 다양한 대안의 효과를 예측할 수 있는 고위험 음주율 관리 시뮬레이션 모형을 개발하는 것이다. 이를 위해 생태학적인 분석에 적합한 지표 데이터를 2019년 지역사회 건강조사, 통계청 지표를 수집하였다. 고위험음주율의 지역 간 변이 및 관련 요인을 파악하기 위해 SPSS Statistics 23을 이용하여 기술통계, 상관분석, 다중회귀분석을 실시하였으며, 지역별 영향을 미치는 요인을 파악하기 위해 Arc GIS를 이용하여 지리적 가중회귀분석, SAS Enterprise Miner 9.4를 이용하여 대화식 의사결정나무를 실시하였다. 고위험 음주율에 영향을 미치는 요인으로 현재흡연율, 인당 상업지역면적, 비만율, 우울감 경험률이 높을수록, 인당 공원면적, 중등도 이상 신체활동 실천율이 낮을수록 고위험음주율이 높은 것으로 분석되었다. 이러한 결과를 기반으로 국가차원에서 시뮬레이션 하는 것을 지원하기 위해 다중회귀분석을 이용하여 모형을 개발하였고, 시‧군‧구 단위의 시뮬레이션을 지원하기 위해지리적 가중회귀분석을 이용하여 모형을 개발하였다. 또한, 실제 개선할 수 있는 요인을 중심으로 시뮬레이션이 가능하도록 대화식 의사결정나무 분석을 통해 모형을 개발하였고, 유형1 그룹이 총228개 지역의 고위험음주율에 비해 음주할 확률이 1.5배 정도 높은 것으로 나타났다. 본 연구의 결과는 지역사회 고위험음주율 관리를 통해 건강수준이 개선됨과 동시에 사업 효과를 증대시킬 수 있으며, 추후 지역사회 건강증진사업 수립에 손쉽게 활용될 것으로 기대된다.
- 24 June 2020
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 56 (4) , e4601
Experimental study on HCl uptake by MgCl2 and sea salt under humid conditions
We studied HCl uptake by MgCl2 and sea salt over a relative humidity (RH) range from 0% to 34% at 278–313 K using a differential bead‐filled flow tube coupled to a high‐pressure chemical ionization mass spectrometer. The results showed that dry MgCl2 and sea salt are essentially inert to gaseous HCl with a probability of less than 10−6. However, under humid conditions, HCl was found to be efficiently taken up by wet inorganic surfaces. The HCl uptake coefficient for MgCl2 and sea salt increased squarely with RH, reaching a value of 0.00123 and 0.00171, respectively, at 29% RH and 298 K. Such wetting behavior is even enhanced at elevated temperatures, with the coefficient reaching 0.00208 and 0.00239, respectively, at 313 K. Based on the study of the dependence of γHCl on the initial HCl concentration, we estimate γHCl as 0.012 at 24% RH at a typical HCl concentration in the troposphere. In addition, the observation of the remarkable enhancement in the OH uptake by the HCl‐treated salts agrees with the results of our previous investigation, which suggested that water absorption on salts enhances γOH by lowering the surface pH. The proposed mechanism of HCl uptake by sea salt aerosol has implications for ozone production in the marine boundary layer.
- 24 June 2020
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 56 (4) , e4601
Experimental study on HCl uptake by MgCl2 and sea salt under humid conditions
We studied HCl uptake by MgCl2 and sea salt over a relative humidity (RH) range from 0% to 34% at 278–313 K using a differential bead‐filled flow tube coupled to a high‐pressure chemical ionization mass spectrometer. The results showed that dry MgCl2 and sea salt are essentially inert to gaseous HCl with a probability of less than 10−6. However, under humid conditions, HCl was found to be efficiently taken up by wet inorganic surfaces. The HCl uptake coefficient for MgCl2 and sea salt increased squarely with RH, reaching a value of 0.00123 and 0.00171, respectively, at 29% RH and 298 K. Such wetting behavior is even enhanced at elevated temperatures, with the coefficient reaching 0.00208 and 0.00239, respectively, at 313 K. Based on the study of the dependence of γHCl on the initial HCl concentration, we estimate γHCl as 0.012 at 24% RH at a typical HCl concentration in the troposphere. In addition, the observation of the remarkable enhancement in the OH uptake by the HCl‐treated salts agrees with the results of our previous investigation, which suggested that water absorption on salts enhances γOH by lowering the surface pH. The proposed mechanism of HCl uptake by sea salt aerosol has implications for ozone production in the marine boundary layer.
- Open Access
- 1 February 2019
- Published by Korean Council of Science Editors in Science Editing
- Vol. 6 (1) , 80-82
Publication ethics workshop: how to cope with predatory journals
- 1 February 2019
- Published by Korean Council of Science Editors in Science Editing
- Vol. 6 (1) , 80-82
Open AccessPublication ethics workshop: how to cope with predatory journals
- 1 March 2018
- Published by Elsevier in Microchemical Journal
- Vol. 137, 334-341
Experimental evaluation of the detection methods of thermal ionization mass spectrometry for isotopic analysis of ultra-trace level uranium
- 1 March 2018
- Published by Elsevier in Microchemical Journal
- Vol. 137, 334-341
Experimental evaluation of the detection methods of thermal ionization mass spectrometry for isotopic analysis of ultra-trace level uranium