Mousalreza Faramarzi Palangar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mousalreza Faramarzi Palangar has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Abu-Siada
School of Electrical Engineering, Computing and Mathematical Sciences, Curtin University, Perth, WA 6102, Australia
2 shared publications - Amin Mahmoudi
College of Science and Engineering, Flinders University, Adelaide, SA 5042, Australia
2 shared publications Mohammad Mirzaie
Department of Electrical and Computer Engineering, Babol University of Technology, Babol, Iran
2 shared publicationsSina Mohseni
Deep Learning Safety, NVIDIA, Santa Clara, CA, USA
2 shared publicationsAmin Mahmoudi
College of Science and Engineering, Flinders University, Adelaide, Australia
1 shared publication- Ghulam Ahmad
School of Electrical Engineering, Southeast University, Nanjing, China
1 shared publication
Latest Publications
- 26 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
Online Condition Monitoring of Overhead Insulators Using Pattern Recognition Algorithm
In this paper commonly-used overhead line insulators are experimentally studied to propose an intelligent diagnosis system (IDS) to correctly identify the insulator health condition in real-time. The proposed IDS is developed based on three diagnostic indicators, third to fifth harmonic ratio of the insulator’s leakage current (LC), cosine of the phase angle of the LC fundamental component, and the ratio of the maximum electric field stress to flashover electric field of the insulator. The proposed diagnostic approach can identify the normal, abnormal and critical conditions of an insulator based on the above-mentioned indicators. Leakage current and flashover voltage are experimentally measured for the studied insulators under various health conditions. Then, recorded data are analyzed to calculate the proposed indicators corresponding to each insulator state. Measured and calculated data are used to intelligently quantify threshold limits of each indicator based on visualization algorithm. In this algorithm, different classifiers are trained with experimental data. The decision tree, which provided the highest precision, is employed to determine reference boundaries of the three indicators for each health state of the insulator. Embedded sensors can measure and sample the LC and electric field stress of the insulator. Sampled data are transmitted to a central processing unit-based receiver via a radio communication channel to automate the identification of the insulator state in real-time.
- 26 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
Online Condition Monitoring of Overhead Insulators Using Pattern Recognition Algorithm
In this paper commonly-used overhead line insulators are experimentally studied to propose an intelligent diagnosis system (IDS) to correctly identify the insulator health condition in real-time. The proposed IDS is developed based on three diagnostic indicators, third to fifth harmonic ratio of the insulator’s leakage current (LC), cosine of the phase angle of the LC fundamental component, and the ratio of the maximum electric field stress to flashover electric field of the insulator. The proposed diagnostic approach can identify the normal, abnormal and critical conditions of an insulator based on the above-mentioned indicators. Leakage current and flashover voltage are experimentally measured for the studied insulators under various health conditions. Then, recorded data are analyzed to calculate the proposed indicators corresponding to each insulator state. Measured and calculated data are used to intelligently quantify threshold limits of each indicator based on visualization algorithm. In this algorithm, different classifiers are trained with experimental data. The decision tree, which provided the highest precision, is employed to determine reference boundaries of the three indicators for each health state of the insulator. Embedded sensors can measure and sample the LC and electric field stress of the insulator. Sampled data are transmitted to a central processing unit-based receiver via a radio communication channel to automate the identification of the insulator state in real-time.
- 19 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 57 (9) , 1-14
Design and Optimization Techniques in Performance Improvement of Line-Start Permanent Magnet Synchronous Motors: A Review
This paper covers the design methodologies and optimisation techniques studied in the performance improvement of line-start permanent magnet synchronous motors (LSPMSM). LSPMSM performance improvement using design techniques are chiefly limited to either the transient or the steady-state performance improvement, and a focus on only the transient performance improvement may degrade the steady-state performance of the LSPMSM and vice versa. Optimisation studies of LSPMSMs can be categorized in terms of optimisation aim in three classifications: transient performance improvement, steady-state performance improvement, and simultaneous improvement of both transient and the steady-state performance. This study indicates the impact of various variables on the LSPMSM performance improvement. The optimisation review shows that starting cage optimisation without considering the steady-state characteristics as constraints results in synchronous performance degradation. The steady-state performance optimization with transient characteristics as constraints results in a minor synchronous performance improvement though there is the lowest transient performance sacrifice. Multi-objective optimization including a transient and a steady-state characteristic as individual objectives resulted in a more optimum LSPMSM with overall performance improvement. Finally, suggestions for optimisation implementation of LSPMSMs are presented for future research work.
- 19 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 57 (9) , 1-14
Design and Optimization Techniques in Performance Improvement of Line-Start Permanent Magnet Synchronous Motors: A Review
This paper covers the design methodologies and optimisation techniques studied in the performance improvement of line-start permanent magnet synchronous motors (LSPMSM). LSPMSM performance improvement using design techniques are chiefly limited to either the transient or the steady-state performance improvement, and a focus on only the transient performance improvement may degrade the steady-state performance of the LSPMSM and vice versa. Optimisation studies of LSPMSMs can be categorized in terms of optimisation aim in three classifications: transient performance improvement, steady-state performance improvement, and simultaneous improvement of both transient and the steady-state performance. This study indicates the impact of various variables on the LSPMSM performance improvement. The optimisation review shows that starting cage optimisation without considering the steady-state characteristics as constraints results in synchronous performance degradation. The steady-state performance optimization with transient characteristics as constraints results in a minor synchronous performance improvement though there is the lowest transient performance sacrifice. Multi-objective optimization including a transient and a steady-state characteristic as individual objectives resulted in a more optimum LSPMSM with overall performance improvement. Finally, suggestions for optimisation implementation of LSPMSMs are presented for future research work.
- 13 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
Identification of Composite Insulator Criticality Based on a New Leakage Current Diagnostic Index
In this article, a new method is proposed to identify the health condition of composite insulators through investigating the leakage current (LC) along with the electric potential (EP) and electric field stress (EFS) profiles. In this regard, variations of the LC harmonics and the distribution profiles of the EP and EFS are investigated through a series of experimental and simulation analyses conducted on composite insulators under various environmental and pollution conditions. Fast Fourier transform (FFT) and a COMSOL-multiphysics environment are utilized to analyze this variation. The results reveal a strong correlation between the LC harmonics and the insulator health condition. A new diagnostic criticality index based on the third to the fifth harmonic ratios of the insulator LC is proposed to quantify the composite insulator criticality and predict the likelihood of flashover occurrence. The EP and EFS analyses can be used to provide a complementary diagnosis of the insulator's health state under severe pollution and humidity conditions. The proposed analysis enables the transmission line network operator to get an insight into the insulators' functional status, thus improving the network reliability through avoiding insulator failure and adopting a proper condition-based maintenance scheme.
- 13 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
Identification of Composite Insulator Criticality Based on a New Leakage Current Diagnostic Index
In this article, a new method is proposed to identify the health condition of composite insulators through investigating the leakage current (LC) along with the electric potential (EP) and electric field stress (EFS) profiles. In this regard, variations of the LC harmonics and the distribution profiles of the EP and EFS are investigated through a series of experimental and simulation analyses conducted on composite insulators under various environmental and pollution conditions. Fast Fourier transform (FFT) and a COMSOL-multiphysics environment are utilized to analyze this variation. The results reveal a strong correlation between the LC harmonics and the insulator health condition. A new diagnostic criticality index based on the third to the fifth harmonic ratios of the insulator LC is proposed to quantify the composite insulator criticality and predict the likelihood of flashover occurrence. The EP and EFS analyses can be used to provide a complementary diagnosis of the insulator's health state under severe pollution and humidity conditions. The proposed analysis enables the transmission line network operator to get an insight into the insulators' functional status, thus improving the network reliability through avoiding insulator failure and adopting a proper condition-based maintenance scheme.
- 20 April 2021
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 46 (10) , 9953-9964
Simultaneous Efficiency and Starting Torque Optimization of a Line-Start Permanent-Magnet Synchronous Motor Using Two Different Optimization Approaches
- 20 April 2021
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 46 (10) , 9953-9964
Simultaneous Efficiency and Starting Torque Optimization of a Line-Start Permanent-Magnet Synchronous Motor Using Two Different Optimization Approaches
- 16 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 18 (2) , 1072-1082
Designing an Automatic Detector Device to Diagnose Insulator State on Overhead Distribution Lines
An automatic detector device (ADD) has been designed and built for monitoring insulators state in overhead distribution lines. The prototyped device is suitable for measurement and analysis of the insulator leakage current ( LC ) on lines of distribution systems to diagnose insulator state. It operates based on two diagnostic indicators, third to fifth harmonic ratio (R 3/5 %) of the insulator's LC signal and cosine of phase angle difference (P.D%) between fundamental signals of the voltage and LC . Experimental data of the indicators in various conditions and various insulators are used to train a classifier for determining reference values of the indices for insulator state detection. The instrument has two physically separate parts: receiver and transmitter. They communicate via a radio communication channel which improves the effectiveness of incident management. The transmitter samples the LC signal of the target insulator using a ferrite core along with a series of active electronic filters. The sampled LC signal is then sent to the receiver. The transmitted LC signal is analyzed by the microprocessor embedded in receiver CPU. Indicators of the transmitted LC signal are calculated and compared with reference values extracted from the classifier. The receiver determines the insulator's state based on the comparison of the estimated and reference values of diagnostic indicators for the target insulator. The performance of the prototyped ADD was evaluated experimentally in the laboratory as well as on overhead distribution lines. These performance tests confirmed reliable performance of the ADD.
- 16 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 18 (2) , 1072-1082
Designing an Automatic Detector Device to Diagnose Insulator State on Overhead Distribution Lines
An automatic detector device (ADD) has been designed and built for monitoring insulators state in overhead distribution lines. The prototyped device is suitable for measurement and analysis of the insulator leakage current ( LC ) on lines of distribution systems to diagnose insulator state. It operates based on two diagnostic indicators, third to fifth harmonic ratio (R 3/5 %) of the insulator's LC signal and cosine of phase angle difference (P.D%) between fundamental signals of the voltage and LC . Experimental data of the indicators in various conditions and various insulators are used to train a classifier for determining reference values of the indices for insulator state detection. The instrument has two physically separate parts: receiver and transmitter. They communicate via a radio communication channel which improves the effectiveness of incident management. The transmitter samples the LC signal of the target insulator using a ferrite core along with a series of active electronic filters. The sampled LC signal is then sent to the receiver. The transmitted LC signal is analyzed by the microprocessor embedded in receiver CPU. Indicators of the transmitted LC signal are calculated and compared with reference values extracted from the classifier. The receiver determines the insulator's state based on the comparison of the estimated and reference values of diagnostic indicators for the target insulator. The performance of the prototyped ADD was evaluated experimentally in the laboratory as well as on overhead distribution lines. These performance tests confirmed reliable performance of the ADD.
- 1 February 2020
- Published by Elsevier in Electric Power Systems Research
- Vol. 179
Improved flashover mathematical model of polluted insulators: A dynamic analysis of the electric arc parameters
- 1 February 2020
- Published by Elsevier in Electric Power Systems Research
- Vol. 179
Improved flashover mathematical model of polluted insulators: A dynamic analysis of the electric arc parameters