Samuel J. Dickerson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Samuel J. Dickerson has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Piervincenzo Rizzo
University of Pittsburgh
9 shared publications - Renee M. Clark
University of Pittsburgh
6 shared publications Hoda Jalali
Laboratory for Nondestructive Evaluation and Structural Health Monitoring Studies, Department of Civil and Environmental Engineering, University of Pittsburgh, Pittsburgh, PA, USA
3 shared publications- Madison Hodgson
Department Electrical and Computer Engineering, 3700 O'Hara Street, 1132 Benedum Hall, University of Pittsburgh, Pittsburgh, PA, 15261, USA
3 shared publications Renee Clark
University of Pittsburgh
3 shared publicationsRenee M. Clark
University of Pittsburgh
3 shared publications
Latest Publications
- 4 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (1) , 908-915
A Tonometer Based on Highly Nonlinear Solitary Waves and Convolutional Autoencoders
Intraocular pressure (IOP) measurements are essential in managing glaucoma, a chronic disease that leads to blindness. The most common way to measure IOP is by applanation, a method that exploits the relationship between IOP and the force necessary to deform the cornea by a certain amount. One of the main limitations of applanation is the challenge to be used at-home for self-tonometry. In this paper, we investigated a tonometer based on an engineering principle novel in ophthalmology with the long-term objective of creating a personalized and portable biomedical device that glaucoma patients can self-proctor anytime, anywhere without the aid of a caregiver. The core of the device is a short tube containing small spherical particles, the last of which is in contact with the eye to be assessed. The spheres support the generation and propagation of highly nonlinear solitary waves (HNSWs), which interact dynamically with the eye under inspection. While the long-term objective of the project is to proctor the instrument above eyelids, in the present study, we tested 49 ex-vivo lamb corneas and quantified the effect of IOP to the joint time-frequency characteristics of HNSWs, propagating through the particles embedded in the tube. Specifically, the spectrograms of the waveforms recorded across 12 – 26 mmHg were extracted to train weighted autoencoders. The algorithms were then used to predict the IOP using the central corneal thickness of the cornea and generated spectrograms. It was found that the percent error of the best performing model was 3.83% and the predictions were >96% accurate with a margin of error of ± 2 mmHg.
- 4 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (1) , 908-915
A Tonometer Based on Highly Nonlinear Solitary Waves and Convolutional Autoencoders
Intraocular pressure (IOP) measurements are essential in managing glaucoma, a chronic disease that leads to blindness. The most common way to measure IOP is by applanation, a method that exploits the relationship between IOP and the force necessary to deform the cornea by a certain amount. One of the main limitations of applanation is the challenge to be used at-home for self-tonometry. In this paper, we investigated a tonometer based on an engineering principle novel in ophthalmology with the long-term objective of creating a personalized and portable biomedical device that glaucoma patients can self-proctor anytime, anywhere without the aid of a caregiver. The core of the device is a short tube containing small spherical particles, the last of which is in contact with the eye to be assessed. The spheres support the generation and propagation of highly nonlinear solitary waves (HNSWs), which interact dynamically with the eye under inspection. While the long-term objective of the project is to proctor the instrument above eyelids, in the present study, we tested 49 ex-vivo lamb corneas and quantified the effect of IOP to the joint time-frequency characteristics of HNSWs, propagating through the particles embedded in the tube. Specifically, the spectrograms of the waveforms recorded across 12 – 26 mmHg were extracted to train weighted autoencoders. The algorithms were then used to predict the IOP using the central corneal thickness of the cornea and generated spectrograms. It was found that the percent error of the best performing model was 3.83% and the predictions were >96% accurate with a margin of error of ± 2 mmHg.
- Open Access
- 9 September 2025
- Published by DEStech Publications
A Solitary Wave-Based Tonometer for Intraocular Pressure Measurement
Glaucoma is an age-related incurable disease and the second cause of blindness in the world. The risk of developing glaucoma increases in the presence of elevated intraocular pressure (IOP), a risk factor that can be modified through invasive surgery. In clinical practice, IOP remains the cornerstone of the diagnosis and management of glaucoma, and Goldmann applanation tonometry (GAT) is considered the gold standard in IOP measurements. However, GAT, as any other commercial system, provides a single data point value that is unable to frame the natural circadian rhythm and sporadic surges of IOP. This capability is only possible with a portable device that patients can eventually self-administer anytime anywhere. To serve the purpose, the device must be easy-to-use and not requiring sterilization or topical anesthesia. Additional desirable features are low price and adaptability to patient’s eyeball geometry. To address these needs, our group has conceptualized, assembled, and tested a new tonometer based on highly nonlinear solitary waves propagating along a chain of particles, the last of which is in dry contact with the eye to be evaluated. The hypothesis is that the time of flight (ToF) of the waves within the chain is monotonically associated with the IOP. In this study, the effect of central corneal thickness (CCT) and IOP of artificial corneas made of polydimethylsiloxane was quantified experimentally and modeled numerically using static and dynamic finite element analyses. The numerical and experimental results agreed in identifying a correlation between ToF and IOP and CCT. However, some quantitative discrepancies between numerical and experimental results warrant the improvement of the model.
- 9 September 2025
- Published by DEStech Publications
Open AccessA Solitary Wave-Based Tonometer for Intraocular Pressure Measurement
Glaucoma is an age-related incurable disease and the second cause of blindness in the world. The risk of developing glaucoma increases in the presence of elevated intraocular pressure (IOP), a risk factor that can be modified through invasive surgery. In clinical practice, IOP remains the cornerstone of the diagnosis and management of glaucoma, and Goldmann applanation tonometry (GAT) is considered the gold standard in IOP measurements. However, GAT, as any other commercial system, provides a single data point value that is unable to frame the natural circadian rhythm and sporadic surges of IOP. This capability is only possible with a portable device that patients can eventually self-administer anytime anywhere. To serve the purpose, the device must be easy-to-use and not requiring sterilization or topical anesthesia. Additional desirable features are low price and adaptability to patient’s eyeball geometry. To address these needs, our group has conceptualized, assembled, and tested a new tonometer based on highly nonlinear solitary waves propagating along a chain of particles, the last of which is in dry contact with the eye to be evaluated. The hypothesis is that the time of flight (ToF) of the waves within the chain is monotonically associated with the IOP. In this study, the effect of central corneal thickness (CCT) and IOP of artificial corneas made of polydimethylsiloxane was quantified experimentally and modeled numerically using static and dynamic finite element analyses. The numerical and experimental results agreed in identifying a correlation between ToF and IOP and CCT. However, some quantitative discrepancies between numerical and experimental results warrant the improvement of the model.
- 8 April 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 168, 107000
Finite element model and experimental validation of a solitary wave-based tonometer
- 8 April 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 168, 107000
Finite element model and experimental validation of a solitary wave-based tonometer
- 15 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Evaluation of Trends from Highly Nonlinear Solitary Wave Transducer in Soft Materials
Highly nonlinear solitary waves (HNSWs) are frequently used to inspect the properties of a material without causing irreversible damage to the structure. Nondestructive evaluation is especially useful in avoiding damage to soft materials with a Young's modulus less than 1MPa. Nondestructive testing would provide insight into biological materials, such as corneas, by monitoring overall eye health and intraocular pressure (IOP). The research in this paper proposes a new application for HNSWs: predicting changes in a cornea correlating to IOP. IOP monitoring is the target application for this research because it is the best methodology for tracking eye disease progression. The HNSWs used for assessment were collected from Polydimethylsiloxane (PDMS) cornea models pressurized from 12mmHg to 26mmHg with 1mmHg increments. Time, amplitude, and frequency content are extracted from each HNSW and compared to estimate the IOP of corneas ranging in thickness from 912μm to 1238μm. To decrease the variability in these three features, a fused variable which reflects the best performing feature in every sample is explored to perform more accurate IOP predictions.
- 15 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Evaluation of Trends from Highly Nonlinear Solitary Wave Transducer in Soft Materials
Highly nonlinear solitary waves (HNSWs) are frequently used to inspect the properties of a material without causing irreversible damage to the structure. Nondestructive evaluation is especially useful in avoiding damage to soft materials with a Young's modulus less than 1MPa. Nondestructive testing would provide insight into biological materials, such as corneas, by monitoring overall eye health and intraocular pressure (IOP). The research in this paper proposes a new application for HNSWs: predicting changes in a cornea correlating to IOP. IOP monitoring is the target application for this research because it is the best methodology for tracking eye disease progression. The HNSWs used for assessment were collected from Polydimethylsiloxane (PDMS) cornea models pressurized from 12mmHg to 26mmHg with 1mmHg increments. Time, amplitude, and frequency content are extracted from each HNSW and compared to estimate the IOP of corneas ranging in thickness from 912μm to 1238μm. To decrease the variability in these three features, a fused variable which reflects the best performing feature in every sample is explored to perform more accurate IOP predictions.
- 7 February 2024
- Published by American Society for Engineering Education
Introducing High-Level Synthesis in Computer Engineering Curricula
- 7 February 2024
- Published by American Society for Engineering Education
Introducing High-Level Synthesis in Computer Engineering Curricula
- 7 February 2024
- Published by American Society for Engineering Education
Accessible Cybersecurity Education for Engineering Students
- 7 February 2024
- Published by American Society for Engineering Education
Accessible Cybersecurity Education for Engineering Students
- Open Access
- 21 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 194-195
Poster: Highly Nonlinear Solitary Wave Transducers for Detecting Eye Pressure Changes
Utilizing a highly nonlinear solitary wave (HNSW) transducer, it is possible to sense the intraocular pressure (IOP) of an eye. A miniature transducer that captures HNSWs has the potential to be utilized at the point-of-care for patients and for self administered monitoring of IOP. It is possible to mimic a human eye using a Polydimethylsiloxane (PDMS) cornea that is pressurized to 10mmhg, 20mmhg, and 30mmhg. The HNSW response, when tested on PDMS at the three different pressures, are unique waves with distinct features. These features can be extracted from each signal and compared to verify whether HNSWs provide enough differentiation between IOPs which would allow for correct identification.
- 21 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 194-195
Open AccessPoster: Highly Nonlinear Solitary Wave Transducers for Detecting Eye Pressure Changes
Utilizing a highly nonlinear solitary wave (HNSW) transducer, it is possible to sense the intraocular pressure (IOP) of an eye. A miniature transducer that captures HNSWs has the potential to be utilized at the point-of-care for patients and for self administered monitoring of IOP. It is possible to mimic a human eye using a Polydimethylsiloxane (PDMS) cornea that is pressurized to 10mmhg, 20mmhg, and 30mmhg. The HNSW response, when tested on PDMS at the three different pressures, are unique waves with distinct features. These features can be extracted from each signal and compared to verify whether HNSWs provide enough differentiation between IOPs which would allow for correct identification.