KLKabin Lin

Kabin Lin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kabin Lin has a total of 52 co-authors. Here are the top co-authors by number of shared publications:

  • Yunfei Chen

    School of Mechanical Engineering, Southeast University, Nanjing, China

    8 shared publications
  • Jingjie Sha

    Jiangsu Key Laboratory for Design and Manufacturing of Precision Medicine Equipment, School of Mechanical Engineering, Southeast University, Nanjing 211100, China

    4 shared publications
  • Kun Li

    Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing 211189, People’s Republic of China

    4 shared publications
  • Zhongwu Li

    Materials Science Division, Physical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, CA 94550, USA

    4 shared publications
  • Yi Tao

    Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing 211189, People’s Republic of China

    3 shared publications
  • Chen Chen

    RIKEN Center for Sustainable Resource Science (CSRS)

    2 shared publications

Latest Publications

  • Capacitance effects of nanopore chips on ionic current modulation and noise characteristics

    by Kabin Lin, Chen Chen, Dongxuan Li, Haoyong Li, Jinzhu Zhou

    Solid-state nanopores exhibit adjustable pore size, robust chemical and thermal stability, and compatibility with semiconductor fabrication, positioning them as versatile platforms for nanofluidic applications and single-molecule detection. However, their higher noise levels compared to biological nanopores hinder their sensitivity in detecting biomolecules such as DNA and proteins. Enhancing detection sensitivity requires an in-depth understanding of noise sources and strategies for noise reduction. Here, we construct an equivalent circuit model of solid-state nanopores and conduct corresponding experiments to evaluate how chip capacitance, salt concentration, applied voltage, and pore size influence ionic current noise. We find that chip capacitance is the dominant factor affecting ionic current noise, with minimal noise sensitivity to salt concentration below 0.1 M but pronounced increases above this threshold. The pH has little impact on noise, whereas higher applied voltages elevate noise at high salt concentrations. Introducing a SiO2 layer between SiN x and Si significantly reduces chip capacitance; a 1000 nm SiO2 layer reduces capacitance to 7.9 pF, decreasing ionic current noise to 18.7 pA for a 2.2 nm nanopore in 1 M KCl at 40 μm membrane side length and 100 mV and 10 kHz sampling. This reduction in capacitance improves response time and measurement accuracy, marking a critical advancement for high-sensitivity applications of solid-state nanopores.


  • Equivalent Circuit-Based Coupling Modeling of Double Bond Ribbons Interconnection Variation in Electronic Packaging

    by Jun Tian, Yucheng Teng, Ruining Li, Yijiang Zhou, Daxing Zhang, Shaoyi Liu, Song Xue, Kabin Lin, Meng Wang, Guojun Leng, et al.

    A method for modeling the interconnection and signal transmission performance of double bond ribbons with configuration variation has been proposed. Arc interval function parameterization has been used to define the geometry of bond ribbons. The coupling model was created using the equivalent circuit approach, taking into account the mutual coupling between two ribbons. The average relative error of return loss is 9.21%, and the average relative error of insertion loss is 0.23%. The accuracy of the model has been verified, and the envelope interval of the signal transmission performance considering the variation of the interconnection configuration has been calculated.


  • Fabrication of solid-state nanopores

    by Kabin Lin, Chen Chen, Congsi Wang, Peiyuan Lian, Yan Wang, Song Xue, Jingjie Sha, Yunfei Chen

    Nanopores are valuable single-molecule sensing tools that have been widely applied to the detection of DNA, RNA, proteins, viruses, glycans, etc. The prominent sensing platform is helping to improve our health-related quality of life and accelerate the rapid realization of precision medicine. Solid-state nanopores have made rapid progress in the past decades due to their flexible size, structure and compatibility with semiconductor fabrication processes. With the development of semiconductor fabrication techniques, materials science and surface chemistry, nanopore preparation and modification technologies have made great breakthroughs. To date, various solid-state nanopore materials, processing technologies, and modification methods are available to us. In the review, we outline the recent advances in nanopores fabrication and analyze the virtues and limitations of various membrane materials and nanopores drilling techniques.


  • Surface Charge Density Inside a Silicon Nitride Nanopore

    by Kabin Lin, Zhongwu Li, Yi Tao, Kun Li, Haojie Yang, Jian Ma, Tie Li, Jingjie Sha, Yunfei Chen

    Surface charges inside a nanopore determine the zeta potential and ion distributions and play a significant role in affecting ion transport and the sensitivity of detecting biomolecules. It is of great importance to study the fluctuation of surface charges with the salt concentration and pH in various applications of nanopores. Herein, we proposed a theoretical model to predict the surface charge density of a Si3N4 nanopore, in which both silanol and amine groups were taken into account. It was demonstrated that the surface charge density in the Si3N4 nanopore changes not only with pH but also with the salt concentration. The theoretical model could well predict the experimental results with different salt concentrations, pH values, and pore sizes. The effect of surface functional groups on the isopotential point (pHiep) of the Si3N4 nanopore was also systematically studied. The results indicated that the silanol groups are major determinants of the surface charge, but the influences of the amine groups should not be ignored because the small number of amine groups can change pHiep dramatically. The pHiep value of the Si3N4 nanopore was measured as 4.1, and the ratio of amine over silanol was ascertained as 0.013.


  • Significantly Enhanced Performance of Nanofluidic Osmotic Power Generation by Slipping Surfaces of Nanopores

    by Long Ma, Kabin Lin, Yinghua Qiu, Jiakun Zhuang, Xuan An, Zhishan Yuan, Chuanzhen Huang


  • Experimental measurement of thermal conductivity along different crystallographic planes in graphite

    by Yu Zhao, Yi Tao, Kabin Lin, Juekuan Yang, Jingjie Sha, Yunfei Chen

    In this work, the time-domain thermoreflectance (TDTR) method is used to measure the thermal conductivity of graphite along different crystallographic planes at room temperature for the first time and the thermal conductivities along the non-principal axes of graphite are obtained. A focused ion beam is used to cut graphite samples along different crystallographic planes for the TDTR measurement. Then, a thermal model is developed to extract the thermal conductivity of graphite along different crystallographic planes from the measured signals of the TDTR method. The measured thermal conductivities along different crystallographic planes in graphite agree well with the anisotropy model, revealing that the traditional TDTR method can be used to measure the non-principal axis thermal conductivity of anisotropic layered materials. Moreover, the experimental results demonstrate that once the crystallographic plane deviates from the cross-plane direction, the in-plane phonon modes will dominate the heat transfer in graphite.


  • Charge Inversion and Calcium Gating in Mixtures of Ions in Nanopores

    by Kabin Lin, Chih-Yuan Lin, Jake W. Polster, Yunfei Chen, Zuzanna S. Siwy

    Calcium ions play important roles in many physiological processes, yet their concentration is much lower than the concentrations of potassium and sodium ions. The selectivity of calcium channels is often probed in mixtures of calcium and a monovalent salt, e.g., KCl or NaCl, prepared such that the concentration of cations is kept constant with the mole fraction of calcium varying from 0 and 1. In biological channels, even sub-mM concentration of calcium can modulate the channels’ transport characteristics; this effect is often explained via the existence of high affinity Ca2+ binding sites on the channel walls. Inspired by properties of biological calcium-selective channels, we prepared a set of nanopores with tunable opening diameters that exhibited a similar response to the presence of calcium ions as biochannels. Nanopores in 15 nm thick silicon nitride films were drilled using focused ion beam and e-beam in a transmission electron microscope and subsequently rendered negatively charged through silanization. We found that nanopores with diameters smaller than 20 nm were blocked by calcium ions such that the ion currents in mixtures of KCl and CaCl2 and in CaCl2 were even ten times smaller than the ion currents in KCl solution. The ion current blockage was explained by the effect of local charge inversion where accumulated calcium ions switch the effective surface charge from negative to positive. The modulation of surface charge with calcium leads to concentration and voltage dependent local charge density and ion current. The combined experimental and modeling results provide a link between calcium ion-induced changes in surface charge properties and resulting ionic transport.


  • Modulation of Charge Density and Charge Polarity of Nanopore Wall by Salt Gradient and Voltage

    by Chih-Yuan Lin, Elif Turker Acar, Jake W. Polster, Kabin Lin, Jyh-Ping Hsu, Zuzanna S. Siwy

    Surface charge plays a very important role in biological processes including ionic and molecular transport across a cell membrane. Placement of charges and charge patterns on walls of polymer and solid-state nanopores allowed preparation of ion-selective systems as well as ionic diodes and transistors to be applied in building biological sensors and ionic circuits. In this article, we show that the surface charge of a 10 nm diameter silicon nitride nanopore placed in contact with a salt gradient is not a constant value, but rather it depends on applied voltage and magnitude of the salt gradient. We found that even when a nanopore was in contact with solutions of pH equivalent to the isoelectric point of the pore surface, the pore walls became charged with voltage-dependent charge density. Implications of the charge gating for detection of proteins passing through a nanopore were considered, as well. Experiments performed with single 30 nm long silicon nitride nanopores were described by continuum modeling, which took into account the surface reactions on the nanopore walls and local modulation of the solution pH in the pore and at the pore entrances. The results revealed that manipulation of surface charge can occur without changing pH of the background electrolyte, which is especially important for applications where maintaining pH at a constant and physiological level is necessary. The system presented also offers a possibility to modulate polarity and magnitude of surface charges in a two-electrode setup, which previously was accomplished in more complex multielectrode systems.


  • Identification of Spherical and Nonspherical Proteins by a Solid-State Nanopore

    by Jingjie Sha, Wei Si, Bing Xu, Shuai Zhang, Kun Li, Kabin Lin, Hongjiao Shi, Yunfei Chen

    Three-dimensional structure of a protein plays an important role in protein dynamics in biological system of human. By now, it remains challenge to characterize and quantify the shape of a protein at single-molecule level. Nanopore, as a novel single-molecule sensor, has been widely applied in many fields such as DNA sequencing and human diseases diagnosis. In this paper, we investigated the translocation of sphere-like con.A and the prolate Bovine Serum Albumin (BSA) under electric field by solid-state nanopore. By analyzing the ionic current, the con.A and the BSA could be characterized and differentiated due to their intrinsic shape difference. Because the prolate BSA will have the preferred orientations for higher electric field when it is residing inside the nanopore, thus multiple ionic current blockade levels will be observed. While for the spherical con.A, there is only one ionic current blockade level. This method presented here will be potentially applied to fingerprint a single protein as a new method having features of low-cost and high-throughput in the near future.


  • Identification of Single Nucleotides by a Tiny Charged Solid-State Nanopore

    by Haojie Yang, Zhongwu Li, Wei Si, Kabin Lin, Jian Ma, Kun Li, Litao Sun, Jingjie Sha, Yunfei Chen

    Discrimination of single nucleotide by a nanopore remains challenge because of the minor difference among the four type single nucleotides. Here, the blockade currents induced by translocation of single nucleotides through a 1.8 nm diameter silicon nitride nanopore have been measured. It is found that the single nucleotides are driven through the nanopore by an electroosmotic flow instead of electrophoretic force when a bias voltage is applied. The blockade currents for the four types of single nucleotides are unique and differentiable, following the order of the nucleotide volume. Also, the dwell-time for each single nucleotide can last to several hundred microseconds with the advantage of the electroosmotic flow, which is helpful to single nucleotide identification. The dwell-time distributions are found to obey the first-passage time distribution from the 1D Fokker-Planck equation, from which the velocity and diffusion constant of each nucleotide can be deduced. Interestingly, the larger nucleotide is found to translocate faster than the smaller one inside the nanopore because the larger nucleotide has larger surface area that may produce larger drag force induced by the electroosmotic flow, which is validated by molecular dynamics simulations.