Andreas Wolfgang Reske
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Andreas Wolfgang Reske has a total of 165 co-authors. Here are the top co-authors by number of shared publications:
Hermann Wrigge
Department of Anaesthesiology and Intensive Care Medicine, University Hospital Leipzig, Leipzig, Germany
6 shared publicationsMatthias Seiwerts
5 shared publicationsUdo Gottschaldt
5 shared publicationsAlexander P. Reske
Anaesthesiology and Intensive Care Medicine, Fachkrankenhaus Coswig, Coswig/Meißen, Germany
4 shared publications- Peter Markus Spieth
Department of Anaesthesiology and Intensive Care Medicine, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology
4 shared publications Susanne Neumann
III. Medical Department (Y.B., S.N., A.R., R.P.), University of Leipzig, 04103 Leipzig, Germany
4 shared publications
Latest Publications
- 20 September 2022
- Published by Springer Nature
- p. 835-851
Respiratorische Insuffizienz und Beatmung
- Open Access
- 31 March 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 17 (9) , 1707-1716
Automated 3D thorax model generation using handheld video-footage
Purpose: For the visualization of pulmonary ventilation with Electrical Impedance Tomography (EIT) most devices use standard reconstruction models, featuring common thorax dimensions and predetermined electrode locations. Any discrepancies between the available model and the patient in terms of body shape and electrode position lead to incorrectly displayed impedance distributions. This work addresses that problem by presenting and evaluating a method for 3D model generation of the thorax and any affixed electrodes based on handheld video-footage. Methods: Therefore, a process was developed, providing users with the ability to capture a patient's chest and the attached electrodes via smartphone. Once data is collected, extracted images are used to generate a 3D model with a structure from motion approach and locate electrodes with ArUco markers. For the evaluation of the developed method, multiple tests were performed in laboratory environments, which were compared with manually created reference models and differences quantified based on mean distance, standard deviation, and maximum distance. Results: The implemented workflow allows for automated model reconstruction based on videos or selected images captured with a handheld device. It generates sparse point clouds from which a surface mesh is reconstructed and returns relative coordinates of any identified ArUco marker. The average value for the mean distance error of two model generations was 5.4 mm while the mean standard deviation was 6.0 mm. The average runtime of twelve reconstructions was 5:17 min, with a minimal runtime of 3:22 min and a maximal runtime of 7:29 min. Conclusion: The presented methods and results show that model reconstruction of a patient’s thorax and applied electrodes at an emergency site is feasible with already available devices. This is a first step toward the automated generation of patient-specific reconstruction models for Electrical Impedance Tomography based on images recorded with handheld devices.
- 31 March 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 17 (9) , 1707-1716
Open AccessAutomated 3D thorax model generation using handheld video-footage
Purpose: For the visualization of pulmonary ventilation with Electrical Impedance Tomography (EIT) most devices use standard reconstruction models, featuring common thorax dimensions and predetermined electrode locations. Any discrepancies between the available model and the patient in terms of body shape and electrode position lead to incorrectly displayed impedance distributions. This work addresses that problem by presenting and evaluating a method for 3D model generation of the thorax and any affixed electrodes based on handheld video-footage. Methods: Therefore, a process was developed, providing users with the ability to capture a patient's chest and the attached electrodes via smartphone. Once data is collected, extracted images are used to generate a 3D model with a structure from motion approach and locate electrodes with ArUco markers. For the evaluation of the developed method, multiple tests were performed in laboratory environments, which were compared with manually created reference models and differences quantified based on mean distance, standard deviation, and maximum distance. Results: The implemented workflow allows for automated model reconstruction based on videos or selected images captured with a handheld device. It generates sparse point clouds from which a surface mesh is reconstructed and returns relative coordinates of any identified ArUco marker. The average value for the mean distance error of two model generations was 5.4 mm while the mean standard deviation was 6.0 mm. The average runtime of twelve reconstructions was 5:17 min, with a minimal runtime of 3:22 min and a maximal runtime of 7:29 min. Conclusion: The presented methods and results show that model reconstruction of a patient’s thorax and applied electrodes at an emergency site is feasible with already available devices. This is a first step toward the automated generation of patient-specific reconstruction models for Electrical Impedance Tomography based on images recorded with handheld devices.
- 23 February 2022
- Published by Springer Nature in Der Nephrologe
- Vol. 17 (3) , 185-188
Akutes Nierenversagen nach Sectio caesarea von Zwillingen
- 23 February 2022
- Published by Springer Nature in Der Nephrologe
- Vol. 17 (3) , 185-188
Akutes Nierenversagen nach Sectio caesarea von Zwillingen
- 1 January 2017
- Published by BMJ in Regional Anesthesia & Pain Medicine
- Vol. 42 (6) , 796-797
Reply to Dr Stimpson et al
- 1 January 2017
- Published by BMJ in Regional Anesthesia & Pain Medicine
- Vol. 42 (6) , 796-797
Reply to Dr Stimpson et al
- Open Access
- 1 December 2015
- Published by Springer Nature in BMC Anesthesiology
- Vol. 16 (1) , 1-13
Experimental blunt chest trauma – cardiorespiratory effects of different mechanical ventilation strategies with high positive end-expiratory pressure: a randomized controlled study
Uncertainty persists regarding the optimal ventilatory strategy in trauma patients developing acute respiratory distress syndrome (ARDS). This work aims to assess the effects of two mechanical ventilation strategies with high positive end-expiratory pressure (PEEP) in experimental ARDS following blunt chest trauma. Twenty-six juvenile pigs were anesthetized, tracheotomized and mechanically ventilated. A contusion was applied to the right chest using a bolt-shot device. Ninety minutes after contusion, animals were randomized to two different ventilation modes, applied for 24 h: Twelve pigs received conventional pressure-controlled ventilation with moderately low tidal volumes (VT, 8 ml/kg) and empirically chosen high external PEEP (16cmH2O) and are referred to as the HP-CMV-group. The other group (n = 14) underwent high-frequency inverse-ratio pressure-controlled ventilation (HFPPV) involving respiratory rate of 65breaths · min−1, inspiratory-to-expiratory-ratio 2:1, development of intrinsic PEEP and recruitment maneuvers, compatible with the rationale of the Open Lung Concept. Hemodynamics, gas exchange and respiratory mechanics were monitored during 24 h. Computed tomography and histology were analyzed in subgroups. Comparing changes which occurred from randomization (90 min after chest trauma) over the 24-h treatment period, groups differed statistically significantly (all P values for group effect <0.001, General Linear Model analysis) for the following parameters (values are mean ± SD for randomization vs. 24-h): PaO2 (100 % O2) (HFPPV 186 ± 82 vs. 450 ± 59 mmHg; HP-CMV 249 ± 73 vs. 243 ± 81 mmHg), venous admixture (HFPPV 34 ± 9.8 vs. 11.2 ± 3.7 %; HP-CMV 33.9 ± 10.5 vs. 21.8 ± 7.2 %), PaCO2 (HFPPV 46.9 ± 6.8 vs. 33.1 ± 2.4 mmHg; HP-CMV 46.3 ± 11.9 vs. 59.7 ± 18.3 mmHg) and normally aerated lung mass (HFPPV 42.8 ± 11.8 vs. 74.6 ± 10.0 %; HP-CMV 40.7 ± 8.6 vs. 53.4 ± 11.6 %). Improvements occurring after recruitment in the HFPPV-group persisted throughout the study. Peak airway pressure and VT did not differ significantly. HFPPV animals had lower atelectasis and inflammation scores in gravity-dependent lung areas. In this model of ARDS following unilateral blunt chest trauma, HFPPV ventilation improved respiratory function and fulfilled relevant ventilation endpoints for trauma patients, i.e. restoration of oxygenation and lung aeration while avoiding hypercapnia and respiratory acidosis.
- 1 December 2015
- Published by Springer Nature in BMC Anesthesiology
- Vol. 16 (1) , 1-13
Open AccessExperimental blunt chest trauma – cardiorespiratory effects of different mechanical ventilation strategies with high positive end-expiratory pressure: a randomized controlled study
Uncertainty persists regarding the optimal ventilatory strategy in trauma patients developing acute respiratory distress syndrome (ARDS). This work aims to assess the effects of two mechanical ventilation strategies with high positive end-expiratory pressure (PEEP) in experimental ARDS following blunt chest trauma. Twenty-six juvenile pigs were anesthetized, tracheotomized and mechanically ventilated. A contusion was applied to the right chest using a bolt-shot device. Ninety minutes after contusion, animals were randomized to two different ventilation modes, applied for 24 h: Twelve pigs received conventional pressure-controlled ventilation with moderately low tidal volumes (VT, 8 ml/kg) and empirically chosen high external PEEP (16cmH2O) and are referred to as the HP-CMV-group. The other group (n = 14) underwent high-frequency inverse-ratio pressure-controlled ventilation (HFPPV) involving respiratory rate of 65breaths · min−1, inspiratory-to-expiratory-ratio 2:1, development of intrinsic PEEP and recruitment maneuvers, compatible with the rationale of the Open Lung Concept. Hemodynamics, gas exchange and respiratory mechanics were monitored during 24 h. Computed tomography and histology were analyzed in subgroups. Comparing changes which occurred from randomization (90 min after chest trauma) over the 24-h treatment period, groups differed statistically significantly (all P values for group effect <0.001, General Linear Model analysis) for the following parameters (values are mean ± SD for randomization vs. 24-h): PaO2 (100 % O2) (HFPPV 186 ± 82 vs. 450 ± 59 mmHg; HP-CMV 249 ± 73 vs. 243 ± 81 mmHg), venous admixture (HFPPV 34 ± 9.8 vs. 11.2 ± 3.7 %; HP-CMV 33.9 ± 10.5 vs. 21.8 ± 7.2 %), PaCO2 (HFPPV 46.9 ± 6.8 vs. 33.1 ± 2.4 mmHg; HP-CMV 46.3 ± 11.9 vs. 59.7 ± 18.3 mmHg) and normally aerated lung mass (HFPPV 42.8 ± 11.8 vs. 74.6 ± 10.0 %; HP-CMV 40.7 ± 8.6 vs. 53.4 ± 11.6 %). Improvements occurring after recruitment in the HFPPV-group persisted throughout the study. Peak airway pressure and VT did not differ significantly. HFPPV animals had lower atelectasis and inflammation scores in gravity-dependent lung areas. In this model of ARDS following unilateral blunt chest trauma, HFPPV ventilation improved respiratory function and fulfilled relevant ventilation endpoints for trauma patients, i.e. restoration of oxygenation and lung aeration while avoiding hypercapnia and respiratory acidosis.
- Open Access
- 10 August 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (8) , e0135272
Correlation of Lung Collapse and Gas Exchange - A Computer Tomographic Study in Sheep and Pigs with Atelectasis in Otherwise Normal Lungs
Atelectasis can provoke pulmonary and non-pulmonary complications after general anaesthesia. Unfortunately, there is no instrument to estimate atelectasis and prompt changes of mechanical ventilation during general anaesthesia. Although arterial partial pressure of oxygen (PaO2) and intrapulmonary shunt have both been suggested to correlate with atelectasis, studies yielded inconsistent results. Therefore, we investigated these correlations. Shunt, PaO2 and atelectasis were measured in 11 sheep and 23 pigs with otherwise normal lungs. In pigs, contrasting measurements were available 12 hours after induction of acute respiratory distress syndrome (ARDS). Atelectasis was calculated by computed tomography relative to total lung mass (Mtotal). We logarithmically transformed PaO2 (lnPaO2) to linearize its relationships with shunt and atelectasis. Data are given as median (interquartile range). Mtotal was 768 (715–884) g in sheep and 543 (503–583) g in pigs. Atelectasis was 26 (16–47) % in sheep and 18 (13–23) % in pigs. PaO2 (FiO2 = 1.0) was 242 (106–414) mmHg in sheep and 480 (437–514) mmHg in pigs. Shunt was 39 (29–51) % in sheep and 15 (11–20) % in pigs. Atelectasis correlated closely with lnPaO2 (R2 = 0.78) and shunt (R2 = 0.79) in sheep (P-values2 (R2 = 0.63) and shunt (R2 = 0.34) was weaker in pigs, but R2 increased to 0.71 for lnPaO2 and 0.72 for shunt 12 hours after induction of ARDS. In both, sheep and pigs, changes in atelectasis correlated strongly with corresponding changes in lnPaO2 and shunt. In lung-healthy sheep, atelectasis correlates closely with lnPaO2 and shunt, when blood gases are measured during ventilation with pure oxygen. In lung-healthy pigs, these correlations were significantly weaker, likely because pigs have stronger hypoxic pulmonary vasoconstriction (HPV) than sheep and humans. Nevertheless, correlations improved also in pigs after blunting of HPV during ARDS. In humans, the observed relationships may aid in assessing anaesthesia-related atelectasis.
- 10 August 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (8) , e0135272
Open AccessCorrelation of Lung Collapse and Gas Exchange - A Computer Tomographic Study in Sheep and Pigs with Atelectasis in Otherwise Normal Lungs
Atelectasis can provoke pulmonary and non-pulmonary complications after general anaesthesia. Unfortunately, there is no instrument to estimate atelectasis and prompt changes of mechanical ventilation during general anaesthesia. Although arterial partial pressure of oxygen (PaO2) and intrapulmonary shunt have both been suggested to correlate with atelectasis, studies yielded inconsistent results. Therefore, we investigated these correlations. Shunt, PaO2 and atelectasis were measured in 11 sheep and 23 pigs with otherwise normal lungs. In pigs, contrasting measurements were available 12 hours after induction of acute respiratory distress syndrome (ARDS). Atelectasis was calculated by computed tomography relative to total lung mass (Mtotal). We logarithmically transformed PaO2 (lnPaO2) to linearize its relationships with shunt and atelectasis. Data are given as median (interquartile range). Mtotal was 768 (715–884) g in sheep and 543 (503–583) g in pigs. Atelectasis was 26 (16–47) % in sheep and 18 (13–23) % in pigs. PaO2 (FiO2 = 1.0) was 242 (106–414) mmHg in sheep and 480 (437–514) mmHg in pigs. Shunt was 39 (29–51) % in sheep and 15 (11–20) % in pigs. Atelectasis correlated closely with lnPaO2 (R2 = 0.78) and shunt (R2 = 0.79) in sheep (P-values2 (R2 = 0.63) and shunt (R2 = 0.34) was weaker in pigs, but R2 increased to 0.71 for lnPaO2 and 0.72 for shunt 12 hours after induction of ARDS. In both, sheep and pigs, changes in atelectasis correlated strongly with corresponding changes in lnPaO2 and shunt. In lung-healthy sheep, atelectasis correlates closely with lnPaO2 and shunt, when blood gases are measured during ventilation with pure oxygen. In lung-healthy pigs, these correlations were significantly weaker, likely because pigs have stronger hypoxic pulmonary vasoconstriction (HPV) than sheep and humans. Nevertheless, correlations improved also in pigs after blunting of HPV during ARDS. In humans, the observed relationships may aid in assessing anaesthesia-related atelectasis.
- Open Access
- 4 August 2015
- Published by Elsevier in Annals of Medicine & Surgery
- Vol. 4 (3) , 254-259
Severe cardiac trauma or myocardial ischemia? Pitfalls of polytrauma treatment in patients with ST-elevation after blunt chest trauma
- 4 August 2015
- Published by Elsevier in Annals of Medicine & Surgery
- Vol. 4 (3) , 254-259
Open AccessSevere cardiac trauma or myocardial ischemia? Pitfalls of polytrauma treatment in patients with ST-elevation after blunt chest trauma
- 1 August 2015
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 32 (8) , 582-584
Epidural catheter removal for initiation of emergency anticoagulant therapy in acute coronary syndrome – when is the time right?
- 1 August 2015
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 32 (8) , 582-584
Epidural catheter removal for initiation of emergency anticoagulant therapy in acute coronary syndrome – when is the time right?
- 29 July 2015
- Vol. 81 (10) , 1058-60
Alpha-2 agonists: back to the future of human anesthesia?
- Open Access
- 28 January 2015
- Vol. 4
Intracorporeal knotting of a femoral nerve catheter
Peripheral nerve catheters are effective and well-established tools to provide postoperative analgesia to patients undergoing orthopedic surgery. The performance of these techniques is usually considered safe. However, placement of nerve catheters may be associated with a considerable number of side effects and major complications have repeatedly been published. In this work, we report on a patient who underwent total knee replacement with spinal anesthesia and preoperative insertion of femoral and sciatic nerve catheters for postoperative analgesia. During insertion of the femoral catheter, significant resistance was encountered upon retracting the catheter. This occurred due to knotting of the catheter. The catheter had to be removed by operative intervention which has to be considered a major complication. The postoperative course was uneventful. The principles for removal of entrapped peripheral catheters are not well established, may differ from those for neuroaxial catheters, and range from cautious manipulation up to surgical intervention.
- 28 January 2015
- Vol. 4
Open AccessIntracorporeal knotting of a femoral nerve catheter
Peripheral nerve catheters are effective and well-established tools to provide postoperative analgesia to patients undergoing orthopedic surgery. The performance of these techniques is usually considered safe. However, placement of nerve catheters may be associated with a considerable number of side effects and major complications have repeatedly been published. In this work, we report on a patient who underwent total knee replacement with spinal anesthesia and preoperative insertion of femoral and sciatic nerve catheters for postoperative analgesia. During insertion of the femoral catheter, significant resistance was encountered upon retracting the catheter. This occurred due to knotting of the catheter. The catheter had to be removed by operative intervention which has to be considered a major complication. The postoperative course was uneventful. The principles for removal of entrapped peripheral catheters are not well established, may differ from those for neuroaxial catheters, and range from cautious manipulation up to surgical intervention.