Elwood P. Armour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Elwood P. Armour has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
Peter M. Corry
Department of Radiation Oncology, Research Laboratories, William Beaumont Hospital, Royal Oak, Michigan
7 shared publicationsYong J. Lee
Department of Radiation Oncology, Research Laboratories, William Beaumont Hospital, Royal Oak, Michigan
3 shared publicationsAlvaro A. Martinez
2 shared publicationsAlvaro Martinez
Department of Radiation Oncology, Wm. Beaumont Hospital, 3601 West 13 Mile Rd., Royal Oak, MI 48073, USA
2 shared publications- Anton Deguet
Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD, USA
2 shared publications Gabor Fichtinger
2 shared publications
Latest Publications
- 1 March 2011
- Published by Elsevier in Brachytherapy
- Vol. 10 (2) , 98-106
Dynamic intraoperative dosimetry for prostate brachytherapy using a nonisocentric C-arm
- 1 March 2011
- Published by Elsevier in Brachytherapy
- Vol. 10 (2) , 98-106
Dynamic intraoperative dosimetry for prostate brachytherapy using a nonisocentric C-arm
- 1 January 2009
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 108 (1) , 202-210
A Novel Process for Introducing a New Intraoperative Program: A Multidisciplinary Paradigm for Mitigating Hazards and Improving Patient Safety
Mance, and efficiency are areas of care that attract a great deal of attention, especially regarding the introduction of new technologies, techniques, and procedures. We describe a multidisciplinary process that was implemented at our hospital to identify and mitigate hazards before the introduction of a new technique: high-dose-rate intraoperative radiation therapy, (HDR-IORT). METHODS: A multidisciplinary team of surgeons, anesthesiologists, radiation oncologists, physicists, nurses, hospital risk managers, and equipment specialists used a structured process that included in situ clinical simulation to uncover concerns among care providers and to prospectively identify and mitigate defects for patients who would undergo surgery using the HDR-IORT technique. RESULTS: We identified and corrected 20 defects in the simulated patient care process before application to actual patients. Subsequently, eight patients underwent surgery using the HDR-IORT technique with no recurrence of simulation-identified or unanticipated defects. CONCLUSION: Multiple benefits were derived from the use of this systematic process to introduce the HDR-IORT technique; namely, the safety and efficiency of care for this select patient population was optimized, and this process mitigated harmful or adverse events before the inclusion of actual patients. Further work is needed, but the process outlined in this paper can be universally applied to the introduction of any new technologies, treatments, or procedures....
- 1 January 2009
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 108 (1) , 202-210
A Novel Process for Introducing a New Intraoperative Program: A Multidisciplinary Paradigm for Mitigating Hazards and Improving Patient Safety
Mance, and efficiency are areas of care that attract a great deal of attention, especially regarding the introduction of new technologies, techniques, and procedures. We describe a multidisciplinary process that was implemented at our hospital to identify and mitigate hazards before the introduction of a new technique: high-dose-rate intraoperative radiation therapy, (HDR-IORT). METHODS: A multidisciplinary team of surgeons, anesthesiologists, radiation oncologists, physicists, nurses, hospital risk managers, and equipment specialists used a structured process that included in situ clinical simulation to uncover concerns among care providers and to prospectively identify and mitigate defects for patients who would undergo surgery using the HDR-IORT technique. RESULTS: We identified and corrected 20 defects in the simulated patient care process before application to actual patients. Subsequently, eight patients underwent surgery using the HDR-IORT technique with no recurrence of simulation-identified or unanticipated defects. CONCLUSION: Multiple benefits were derived from the use of this systematic process to introduce the HDR-IORT technique; namely, the safety and efficiency of care for this select patient population was optimized, and this process mitigated harmful or adverse events before the inclusion of actual patients. Further work is needed, but the process outlined in this paper can be universally applied to the introduction of any new technologies, treatments, or procedures....
- 1 April 2008
- Published by Elsevier in Brachytherapy
- Vol. 7 (2) , 102
Registered ultrasound and fluoroscopy for intraoperative dynamic dosimetry in prostate brachytherapy
- 1 April 2008
- Published by Elsevier in Brachytherapy
- Vol. 7 (2) , 102
Registered ultrasound and fluoroscopy for intraoperative dynamic dosimetry in prostate brachytherapy
- 26 April 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (10) , 2729-2740
The small-animal radiation research platform (SARRP): dosimetry of a focused lens system
A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV. Here, we report on the dosimetric characteristics of the focused beam from the x-ray lens subsystem for high-resolution dose delivery. Using the metric of the average dose within a 1.5 mm diameter area, the dose rates at a source-to-surface distance (SSD) of 34 cm are 259 and 172 cGy min(-1) at 6 mm and 2 cm depths, respectively, with an estimated uncertainty of +/-5%. The per cent depth dose is approximately 56% at 2 cm depth for a beam at 34 cm SSD.
- 26 April 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (10) , 2729-2740
The small-animal radiation research platform (SARRP): dosimetry of a focused lens system
A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV. Here, we report on the dosimetric characteristics of the focused beam from the x-ray lens subsystem for high-resolution dose delivery. Using the metric of the average dose within a 1.5 mm diameter area, the dose rates at a source-to-surface distance (SSD) of 34 cm are 259 and 172 cGy min(-1) at 6 mm and 2 cm depths, respectively, with an estimated uncertainty of +/-5%. The per cent depth dose is approximately 56% at 2 cm depth for a beam at 34 cm SSD.
- 1 June 2006
- Published by Wiley in Medical Physics
- Vol. 33 (6Part4) , 2017
SU-FF-I-88: The Small Animal Radiation Research Platform: Benchtop Cone-Beam CT
- 1 June 2006
- Published by Wiley in Medical Physics
- Vol. 33 (6Part4) , 2017
SU-FF-I-88: The Small Animal Radiation Research Platform: Benchtop Cone-Beam CT
- Open Access
- 1 December 2005
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 21 (8) , 769-778
The heat shock response: Role in radiation biology and cancer therapy
Since prehistoric times, elevated temperatures have been used to treat cancer in a variety of forms. In modern times (the last 40 years) efforts have concentrated on combining heat with other anti-tumour modalities, principally ionizing radiation and some chemotherapeutic drugs. Despite the emphasis on combined therapy, rodent data relating to heat sensitivity and thermal tolerance development assumed principal importance. These considerations suggested treating at 43°C as a target temperature and fractionation schemes emphasizing thermal tolerance avoidance. Concomitantly crucial data on heat-induced tumour reoxygenation and its temperature dependence were largely ignored. In reality these were unrealistic and undesirable goals. The preponderance of evidence now suggests that lower temperatures (40–42°C) administered more frequently, optimally immediately before and during each administration of ionizing radiation, are likely to yield optimal results. Factoring in trimodality therapy and other combinations of chemotherapeutic drugs will require some modifications of such fractionation schemes.
- 1 December 2005
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 21 (8) , 769-778
Open AccessThe heat shock response: Role in radiation biology and cancer therapy
Since prehistoric times, elevated temperatures have been used to treat cancer in a variety of forms. In modern times (the last 40 years) efforts have concentrated on combining heat with other anti-tumour modalities, principally ionizing radiation and some chemotherapeutic drugs. Despite the emphasis on combined therapy, rodent data relating to heat sensitivity and thermal tolerance development assumed principal importance. These considerations suggested treating at 43°C as a target temperature and fractionation schemes emphasizing thermal tolerance avoidance. Concomitantly crucial data on heat-induced tumour reoxygenation and its temperature dependence were largely ignored. In reality these were unrealistic and undesirable goals. The preponderance of evidence now suggests that lower temperatures (40–42°C) administered more frequently, optimally immediately before and during each administration of ionizing radiation, are likely to yield optimal results. Factoring in trimodality therapy and other combinations of chemotherapeutic drugs will require some modifications of such fractionation schemes.
- 1 November 2002
- Published by Wolters Kluwer Health in The Cancer Journal
- Vol. 8 (6) , 493
Dose Escalation Using Conformal High Dose Rate Brachytherapy Improves the Outcome in Unfavorable Prostate Cancer
- 1 November 2002
- Published by Wolters Kluwer Health in The Cancer Journal
- Vol. 8 (6) , 493
Dose Escalation Using Conformal High Dose Rate Brachytherapy Improves the Outcome in Unfavorable Prostate Cancer
- 1 August 2002
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 53 (5) , 1393
In response to Dr. Lee
- 1 August 2002
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 53 (5) , 1393
In response to Dr. Lee
- 1 March 1997
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 37 (5) , 1155-1161
Reproducible rat model for comparing late rectal toxicity from different brachytherapy techniques
- 1 March 1997
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 37 (5) , 1155-1161
Reproducible rat model for comparing late rectal toxicity from different brachytherapy techniques
Lack of radiosensitization after paclitaxel treatment of three human carcinoma cell lines
Background. Several recent studies have suggested radiosensitizing effects of paclitaxel, a microtubular inhibitor. To test the universality of this finding, the interaction between paclitaxel and radiation treatment of cell lines derived from three common human carcinomas MCF-7 (breast cancer); DUT-145 (prostate cancer); and HT-29 (colon cancer) was evaluated. The study focused on the ability of paclitaxel to block cells at the G2-M phase of the cell cycle and potentially enhance the radiation sensitivity of the cells. Methods. All cell lines were exposed to three different clinically achievable paclitaxel concentrations ranging from 2 nM to 25 nM. Paclitaxel pretreatment for 12 and 24 hours before radiation was tested in all three cell lines. The radiation dose ranged from 0 to 8 Gy delivered in a single fraction. Cellular survival after treatment with paclitaxel and/or radiation was determined by clonogenic assay. Cell cycle distribution as determined by flow cytometry was performed after various dose-time combinations of paclitaxel. Results. Cytotoxicity studies with paclitaxel alone demonstrated a time-dependent and dose-dependent survival relationship for all three cell lines. Resultant surviving fractions were in the range of 5 to 90% after 24-hour exposure to paclitaxel alone. The interaction between paclitaxel and radiation was primarily additive in each of the three cell lines for all paclitaxel dose-time combinations studied. Flow cytometric analysis failed to reveal a prominent G2-M block in all three cell lines after paclitaxel treatment for 24 hours. Conclusions. Paclitaxel lacked a radiosensitizing effect on MCF-7, DUT-145, and HT-29 cells in this study. These results should be considered when designing clinical trials that use paclitaxel as a potential radiosensitizer of certain human carcinomas.
Lack of radiosensitization after paclitaxel treatment of three human carcinoma cell lines
Background. Several recent studies have suggested radiosensitizing effects of paclitaxel, a microtubular inhibitor. To test the universality of this finding, the interaction between paclitaxel and radiation treatment of cell lines derived from three common human carcinomas MCF-7 (breast cancer); DUT-145 (prostate cancer); and HT-29 (colon cancer) was evaluated. The study focused on the ability of paclitaxel to block cells at the G2-M phase of the cell cycle and potentially enhance the radiation sensitivity of the cells. Methods. All cell lines were exposed to three different clinically achievable paclitaxel concentrations ranging from 2 nM to 25 nM. Paclitaxel pretreatment for 12 and 24 hours before radiation was tested in all three cell lines. The radiation dose ranged from 0 to 8 Gy delivered in a single fraction. Cellular survival after treatment with paclitaxel and/or radiation was determined by clonogenic assay. Cell cycle distribution as determined by flow cytometry was performed after various dose-time combinations of paclitaxel. Results. Cytotoxicity studies with paclitaxel alone demonstrated a time-dependent and dose-dependent survival relationship for all three cell lines. Resultant surviving fractions were in the range of 5 to 90% after 24-hour exposure to paclitaxel alone. The interaction between paclitaxel and radiation was primarily additive in each of the three cell lines for all paclitaxel dose-time combinations studied. Flow cytometric analysis failed to reveal a prominent G2-M block in all three cell lines after paclitaxel treatment for 24 hours. Conclusions. Paclitaxel lacked a radiosensitizing effect on MCF-7, DUT-145, and HT-29 cells in this study. These results should be considered when designing clinical trials that use paclitaxel as a potential radiosensitizer of certain human carcinomas.