Ikuho Kojima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ikuho Kojima has a total of 170 co-authors. Here are the top co-authors by number of shared publications:
- Masahiro Iikubo
Department of Dental Informatics and Radiology, Tohoku University Graduate School of Dentistry , Sendai, Miyagi 980-8575
13 shared publications Maya Sakamoto
Department of Oral Diagnosis, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8575, Japan
13 shared publicationsMasahiro Iikubo
Division of Oral and Maxillofacial Radiology, Tohoku University Hospital, Sendai, JAPAN
9 shared publicationsTakashi Sasano
Department of Oral Diagnosis, Tohoku University Graduate School of Dentistry, Sendai, Japan
8 shared publications- Takashi Nishioka
Division of Oral Diagnosis, Tohoku University Graduate School of Dentistry, Sendai, Miyagi, Japan
5 shared publications - Takenori Ogawa
Department of Otolaryngology, Gifu University, Gifu, Japan
5 shared publications
Latest Publications
- Open Access
- 6 July 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (7) , 812-819
Image sharpening improves the visibility of reference points on low-dose lateral cephalometric radiographs: a phantom study
This phantom study aimed to determine whether a novel non-artificial intelligence image-sharpening approach improves the visibility of reference points on low-dose lateral cephalometric radiographs. Lateral cephalometric radiographs were obtained using an adult human bone phantom at 100% of the routine dose. Low-dose imaging was performed using 60%, 40%, and 20% of the routine dose. Each low-dose image underwent a 2-level image-sharpening process using the Medical Image Enhancer software. Six reviewers evaluated the visibility of the 5 reference points in the first and second sets of sharpened and 100% radiation-dose images. Using Scheffé’s method of paired comparisons, odds ratios (ORs) were reported as relative values for a standard cephalometric radiograph (100% radiation dose) to compare the visibility of reference points among imaging conditions. For the first set of mildly sharpened 60%-dose images, the ORs for the 4 reference points were >1.0, Point A (OR 1.12, P = .83), Nasion (OR 2.26, P = .11), posterior nasal spine (OR 2.35, P = .1), and incisal edge of the maxillary central incisor (OR 1.35, P = .53), indicating visibility comparable to or better than the 100%-dose images. For the second set of markedly sharpened images, rated visibility was significantly higher for all reference points at 60% and 40% doses and for several reference points at 20% dose. Image-sharpening algorithms improved the visibility of reference points on low-dose phantom radiographs, suggesting their technical feasibility as a post-acquisition approach for dose-reduced cephalometric imaging.
- 6 July 2026
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (7) , 812-819
Open AccessImage sharpening improves the visibility of reference points on low-dose lateral cephalometric radiographs: a phantom study
This phantom study aimed to determine whether a novel non-artificial intelligence image-sharpening approach improves the visibility of reference points on low-dose lateral cephalometric radiographs. Lateral cephalometric radiographs were obtained using an adult human bone phantom at 100% of the routine dose. Low-dose imaging was performed using 60%, 40%, and 20% of the routine dose. Each low-dose image underwent a 2-level image-sharpening process using the Medical Image Enhancer software. Six reviewers evaluated the visibility of the 5 reference points in the first and second sets of sharpened and 100% radiation-dose images. Using Scheffé’s method of paired comparisons, odds ratios (ORs) were reported as relative values for a standard cephalometric radiograph (100% radiation dose) to compare the visibility of reference points among imaging conditions. For the first set of mildly sharpened 60%-dose images, the ORs for the 4 reference points were >1.0, Point A (OR 1.12, P = .83), Nasion (OR 2.26, P = .11), posterior nasal spine (OR 2.35, P = .1), and incisal edge of the maxillary central incisor (OR 1.35, P = .53), indicating visibility comparable to or better than the 100%-dose images. For the second set of markedly sharpened images, rated visibility was significantly higher for all reference points at 60% and 40% doses and for several reference points at 20% dose. Image-sharpening algorithms improved the visibility of reference points on low-dose phantom radiographs, suggesting their technical feasibility as a post-acquisition approach for dose-reduced cephalometric imaging.
- Open Access
- 8 January 2026
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 49 (2) , 1-13
Pediatric dental cone-beam computed tomography using half-acquisition and low-noise reconstruction: visual evaluation of clinical images
This study evaluated whether half-acquisition (180° scan) pediatric cone-beam computed tomography (CBCT; 3D Accuitomo F17, J. Morita, Kyoto, Japan) reduces radiation exposure while maintaining sufficient diagnostic image quality for identifying ectopic eruptions and impacted teeth. Additionally, it was investigated whether a low-noise reconstruction filter (G_101) mitigates image quality degradation in 180° scans. Three board-certified oral and maxillofacial radiologists certified by the Japanese Society for Oral and Maxillofacial Radiology visually evaluated clinical images from 12 pediatric patients (aged 6–10 years). The image quality was objectively assessed using phantom-based analyses of the modulation transfer function (MTF), noise power spectrum (NPS), and comprehensive objective image quality calculated from MTF and NPS values. Although 180° images showed increased noise and slightly lower visual assessment scores compared with 360° images, they remained diagnostically acceptable. In 180° reconstructions, the median visual scores with the G_101 filter were slightly higher than those with the standard G_001 filter, with small differences (within approximately 0–3 points on a 100-point scale), although the differences were not statistically significant. Interestingly, in approximately 28% of 180 evaluations, 180° images scored higher than 360° images, likely due to reduced motion artefacts from shorter acquisition. In a previous phantom experiment, the dose area product (DAP) for 360° and 180° scans was 490 mGy cm 2 and 249 mGy cm 2 , respectively, indicating that 180° scan reduces radiation exposure while maintaining clinically acceptable image quality. These findings suggest that half-acquisition, when combined with an appropriate reconstruction filter, may offer a practical, low-dose alternative for pediatric dental imaging.
- 8 January 2026
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 49 (2) , 1-13
Open AccessPediatric dental cone-beam computed tomography using half-acquisition and low-noise reconstruction: visual evaluation of clinical images
This study evaluated whether half-acquisition (180° scan) pediatric cone-beam computed tomography (CBCT; 3D Accuitomo F17, J. Morita, Kyoto, Japan) reduces radiation exposure while maintaining sufficient diagnostic image quality for identifying ectopic eruptions and impacted teeth. Additionally, it was investigated whether a low-noise reconstruction filter (G_101) mitigates image quality degradation in 180° scans. Three board-certified oral and maxillofacial radiologists certified by the Japanese Society for Oral and Maxillofacial Radiology visually evaluated clinical images from 12 pediatric patients (aged 6–10 years). The image quality was objectively assessed using phantom-based analyses of the modulation transfer function (MTF), noise power spectrum (NPS), and comprehensive objective image quality calculated from MTF and NPS values. Although 180° images showed increased noise and slightly lower visual assessment scores compared with 360° images, they remained diagnostically acceptable. In 180° reconstructions, the median visual scores with the G_101 filter were slightly higher than those with the standard G_001 filter, with small differences (within approximately 0–3 points on a 100-point scale), although the differences were not statistically significant. Interestingly, in approximately 28% of 180 evaluations, 180° images scored higher than 360° images, likely due to reduced motion artefacts from shorter acquisition. In a previous phantom experiment, the dose area product (DAP) for 360° and 180° scans was 490 mGy cm 2 and 249 mGy cm 2 , respectively, indicating that 180° scan reduces radiation exposure while maintaining clinically acceptable image quality. These findings suggest that half-acquisition, when combined with an appropriate reconstruction filter, may offer a practical, low-dose alternative for pediatric dental imaging.
- Open Access
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56
Effect of head movement on the image compositing accuracy of the stitching function in cone-beam computed tomography: Differences in stitching areas and dental metal conditions
Suzuki M, et al. Imaging Sci Dent. 2026 ;56:e48. https://doi.org/10.5624/isd.20260195
- 1 January 2026
- Published by XMLink in Imaging Science in Dentistry
- Vol. 56
Open AccessEffect of head movement on the image compositing accuracy of the stitching function in cone-beam computed tomography: Differences in stitching areas and dental metal conditions
Suzuki M, et al. Imaging Sci Dent. 2026 ;56:e48. https://doi.org/10.5624/isd.20260195
- Open Access
- 27 December 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
An interpretable machine learning model using SHapley Additive exPlanations for preoperative cervical lymph node metastasis risk stratification in tongue squamous cell carcinoma: a multicenter study
Tongue squamous cell carcinoma (TSCC) is characterized by early lymph node metastasis (LNM), which significantly impacts prognosis. Traditional diagnostic
- 27 December 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Open AccessAn interpretable machine learning model using SHapley Additive exPlanations for preoperative cervical lymph node metastasis risk stratification in tongue squamous cell carcinoma: a multicenter study
Tongue squamous cell carcinoma (TSCC) is characterized by early lymph node metastasis (LNM), which significantly impacts prognosis. Traditional diagnostic
- 6 August 2025
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (1) , 73-79
Effect of dental metal prostheses and its metal artefacts on the incidence of nodular overcorrection on PET/CT images: a comparison between silicon photomultiplier and photomultiplier tube PET
Objectives: Positron emission tomography (PET) images are reconstructed using computed tomography (CT)-based attenuation correction, which may cause artefactual errors due to CT artefacts. This study aimed to investigate the effects of metallic dental prostheses and metal artefacts on the incidence of nodular overcorrection in PET/CT images of the oral cavity in patients with head and neck tumours. Methods: We retrospectively reviewed the F-18 fluorodeoxyglucose PET/CT images of 27 and 20 patients using silicon photomultiplier (SiPM) and photomultiplier tube (PMT) PET, respectively. We evaluated the presence or absence of overcorrection of tumour-like nodular uptake, number of metallic dental prostheses, number of metallic prosthetic blocks, mean CT values, bright-band artefact area/ratio, and dark-band artefact area/ratio. Results: There was no significant difference in the incidence of overcorrections between SiPM and PMT PET; however, overcorrections in the former were significantly smaller in size than those in the latter. Overcorrection in PMT PET was more likely to occur when the number of metallic dental prostheses, number of metallic dental prosthetic blocks, mean CT value, and bright-band artefact area/ratio were high. However, there was no significant difference in SiPM PET overcorrection between the positive and negative overcorrection groups for the above conditions. Conclusion: Overcorrection was associated with metallic dental prostheses and CT artefacts; however, the conditions may have scanner-specific characteristics. Advances in knowledge: Small tumour-like overcorrections appear on SiPM PET, which should be noted because it is more difficult to notice overcorrections. It is important to analyse the images while checking the pre-attenuation correction PET.
- 6 August 2025
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (1) , 73-79
Effect of dental metal prostheses and its metal artefacts on the incidence of nodular overcorrection on PET/CT images: a comparison between silicon photomultiplier and photomultiplier tube PET
Objectives: Positron emission tomography (PET) images are reconstructed using computed tomography (CT)-based attenuation correction, which may cause artefactual errors due to CT artefacts. This study aimed to investigate the effects of metallic dental prostheses and metal artefacts on the incidence of nodular overcorrection in PET/CT images of the oral cavity in patients with head and neck tumours. Methods: We retrospectively reviewed the F-18 fluorodeoxyglucose PET/CT images of 27 and 20 patients using silicon photomultiplier (SiPM) and photomultiplier tube (PMT) PET, respectively. We evaluated the presence or absence of overcorrection of tumour-like nodular uptake, number of metallic dental prostheses, number of metallic prosthetic blocks, mean CT values, bright-band artefact area/ratio, and dark-band artefact area/ratio. Results: There was no significant difference in the incidence of overcorrections between SiPM and PMT PET; however, overcorrections in the former were significantly smaller in size than those in the latter. Overcorrection in PMT PET was more likely to occur when the number of metallic dental prostheses, number of metallic dental prosthetic blocks, mean CT value, and bright-band artefact area/ratio were high. However, there was no significant difference in SiPM PET overcorrection between the positive and negative overcorrection groups for the above conditions. Conclusion: Overcorrection was associated with metallic dental prostheses and CT artefacts; however, the conditions may have scanner-specific characteristics. Advances in knowledge: Small tumour-like overcorrections appear on SiPM PET, which should be noted because it is more difficult to notice overcorrections. It is important to analyse the images while checking the pre-attenuation correction PET.
- 28 March 2025
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 282 (7) , 3723-3728
Locally advanced maxillary sinus cancer fed from the internal carotid artery
Objective Superselective intra-arterial infusion of cisplatin and concomitant radiation therapy (RADPLAT) is one of the effective treatments for advanced maxillary sinus cancer, and prospective trials have been conducted. However, treatment of cases with intraorbital infiltration or skull base infiltration that are fed from the internal carotid artery (ICA) may be problematic. In this study, we investigated the frequency, treatment, and prognosis of locally advanced maxillary sinus cancer fed from the ICA. Method This study included patients with locally advanced maxillary sinus cancer (clinical T4a or T4b) who underwent RADPLAT only via external carotid artery from January 2008 to January 2024. Result Nineteen of 44 cases were fed from the ICA (43.2%). Three-year overall survival (OS), three-year progression-free survival (PFS), and three-year local control rate (LCR) of all cases were 69.8%, 47.5%, and 61.8%, respectively. The three-year OS, PFS and LCR were equivalent between cases with or without feeding from the ICA. Conclusion This study revealed the frequency and prognosis of locally advanced maxillary sinus cancer fed from the ICA. The prognosis was equivalent between cases with or without feeding from the ICA; therefore, it would be considered important to determine the tumor volume for each feeding blood vessel and assess the areas of dual perfusion.
- 28 March 2025
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 282 (7) , 3723-3728
Locally advanced maxillary sinus cancer fed from the internal carotid artery
Objective Superselective intra-arterial infusion of cisplatin and concomitant radiation therapy (RADPLAT) is one of the effective treatments for advanced maxillary sinus cancer, and prospective trials have been conducted. However, treatment of cases with intraorbital infiltration or skull base infiltration that are fed from the internal carotid artery (ICA) may be problematic. In this study, we investigated the frequency, treatment, and prognosis of locally advanced maxillary sinus cancer fed from the ICA. Method This study included patients with locally advanced maxillary sinus cancer (clinical T4a or T4b) who underwent RADPLAT only via external carotid artery from January 2008 to January 2024. Result Nineteen of 44 cases were fed from the ICA (43.2%). Three-year overall survival (OS), three-year progression-free survival (PFS), and three-year local control rate (LCR) of all cases were 69.8%, 47.5%, and 61.8%, respectively. The three-year OS, PFS and LCR were equivalent between cases with or without feeding from the ICA. Conclusion This study revealed the frequency and prognosis of locally advanced maxillary sinus cancer fed from the ICA. The prognosis was equivalent between cases with or without feeding from the ICA; therefore, it would be considered important to determine the tumor volume for each feeding blood vessel and assess the areas of dual perfusion.
- 21 December 2024
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 29 (1) , 1-12
Automated classification of pathological differentiation in head and neck squamous cell carcinoma using combined radiomics models from CET1WI and T2WI
Objectives This study aims to develop an automated radiomics-based model to grade the pathological differentiation of head and neck squamous cell carcinoma (HNSCC) and to assess the influence of various magnetic resonance imaging (MRI) sequences on the model’s performance. Materials and methods We retrospectively analyzed MRI data from 256 patients across two medical centers, including both contrast-enhanced T1-weighted images (CET1WI) and T2-weighted images (T2WI). Regions of interest were delineated for radiomics feature extraction, followed by dimensionality reduction. An XGBoost classifier was then employed to build the predictive model, with its classification efficiency assessed using receiver operating characteristic curves and the area under the curve (AUC). Results In validation cohort, the AUC (macro/micro) values for models utilizing CET1WI, T2WI, and the combination of CET1WI and T2WI were 0.801/0.814, 0.741/0.798, and 0.885/0.895, respectively. The AUC for the three differentiations, ranging from well-differentiated to poorly differentiated, were 0.867, 0.909, and 0.837, respectively. The macro/micro precision, recall, and F1 scores of 0.688/0.736, 0.744/0.828, and 0.685/0.779 for the CET1WI + T2WI model. Conclusion This study demonstrates that constructing a radiomics model based on CET1WI and T2WI sequences can be used to predict the pathological differentiation grading of HNSCC patients. Clinical relevance This study suggests that a radiomics model integrating CET1WI and T2WI MRI sequences can effectively predict the pathological differentiation of HNSCC, providing an alternative diagnostic approach through non-invasive preoperative methods.
- 21 December 2024
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 29 (1) , 1-12
Automated classification of pathological differentiation in head and neck squamous cell carcinoma using combined radiomics models from CET1WI and T2WI
Objectives This study aims to develop an automated radiomics-based model to grade the pathological differentiation of head and neck squamous cell carcinoma (HNSCC) and to assess the influence of various magnetic resonance imaging (MRI) sequences on the model’s performance. Materials and methods We retrospectively analyzed MRI data from 256 patients across two medical centers, including both contrast-enhanced T1-weighted images (CET1WI) and T2-weighted images (T2WI). Regions of interest were delineated for radiomics feature extraction, followed by dimensionality reduction. An XGBoost classifier was then employed to build the predictive model, with its classification efficiency assessed using receiver operating characteristic curves and the area under the curve (AUC). Results In validation cohort, the AUC (macro/micro) values for models utilizing CET1WI, T2WI, and the combination of CET1WI and T2WI were 0.801/0.814, 0.741/0.798, and 0.885/0.895, respectively. The AUC for the three differentiations, ranging from well-differentiated to poorly differentiated, were 0.867, 0.909, and 0.837, respectively. The macro/micro precision, recall, and F1 scores of 0.688/0.736, 0.744/0.828, and 0.685/0.779 for the CET1WI + T2WI model. Conclusion This study demonstrates that constructing a radiomics model based on CET1WI and T2WI sequences can be used to predict the pathological differentiation grading of HNSCC patients. Clinical relevance This study suggests that a radiomics model integrating CET1WI and T2WI MRI sequences can effectively predict the pathological differentiation of HNSCC, providing an alternative diagnostic approach through non-invasive preoperative methods.
- 12 December 2024
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 282 (5) , 2533-2538
CT scoring system for differentiating of sinonasal inverted papilloma and squamous cell carcinoma arising from inverted papilloma
Objective To distinguish squamous cell carcinoma in inverted papilloma (IP-SCC) from IP, the utility of CT scoring system was investigated. Methods We extracted cases histopathologically diagnosed with IP and IP-SCC of the sinonasal cavity from June 2004 to May 2021. Preoperative unenhanced CT images were used to evaluate the presence or absence of bone destruction and erosion: Score 1 = positive for bone destruction and/or erosion; Score 0 = negative for bone destruction and erosion. The CT scores in 10 sites of the sinonasal cavity and their adjacent areas were calculated. Results Fifty-six cases of IP and 20 cases of IP-SCC were enrolled in this study. Bone destruction and/or erosion was more frequently observed in IP-SCC than in IP at the sites of the skull base (p = 0.0001), orbital wall (p < 0.0001), maxillary sinus (p < 0.0001), nasal septum (p < 0.0001), inferior nasal concha (p = 0.0046), ethmoid sinus (p < 0.0001), pterygoid process (p = 0.0031), and frontal sinus (p = 0.0009). The total CT scores at the 10 sites for diagnosing IP-SCC had sensitivity and specificity of 70% and 87.5% (AUC: 0.810, p < 0.001); furthermore, those at the eight sites excluding fontanelle and middle nasal concha improved sensitivity and specificity of 75% and 83.9% (optimal threshold of 2, AUC: 0.862, p < 0.001). Conclusion The CT scoring system evaluating bone destruction and erosion could accurately differentiate IP-SCC from IP.
- 12 December 2024
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 282 (5) , 2533-2538
CT scoring system for differentiating of sinonasal inverted papilloma and squamous cell carcinoma arising from inverted papilloma
Objective To distinguish squamous cell carcinoma in inverted papilloma (IP-SCC) from IP, the utility of CT scoring system was investigated. Methods We extracted cases histopathologically diagnosed with IP and IP-SCC of the sinonasal cavity from June 2004 to May 2021. Preoperative unenhanced CT images were used to evaluate the presence or absence of bone destruction and erosion: Score 1 = positive for bone destruction and/or erosion; Score 0 = negative for bone destruction and erosion. The CT scores in 10 sites of the sinonasal cavity and their adjacent areas were calculated. Results Fifty-six cases of IP and 20 cases of IP-SCC were enrolled in this study. Bone destruction and/or erosion was more frequently observed in IP-SCC than in IP at the sites of the skull base (p = 0.0001), orbital wall (p < 0.0001), maxillary sinus (p < 0.0001), nasal septum (p < 0.0001), inferior nasal concha (p = 0.0046), ethmoid sinus (p < 0.0001), pterygoid process (p = 0.0031), and frontal sinus (p = 0.0009). The total CT scores at the 10 sites for diagnosing IP-SCC had sensitivity and specificity of 70% and 87.5% (AUC: 0.810, p < 0.001); furthermore, those at the eight sites excluding fontanelle and middle nasal concha improved sensitivity and specificity of 75% and 83.9% (optimal threshold of 2, AUC: 0.862, p < 0.001). Conclusion The CT scoring system evaluating bone destruction and erosion could accurately differentiate IP-SCC from IP.
- Open Access
- 9 October 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (19) , 9154
Effects of Different Fields of View and Rotation Angles on Radiation Doses to Highly Radiosensitive Organs in Children Using Dental Cone Beam Computed Tomography
Dental cone beam computed tomography (CBCT) is a diverse 3D X-ray imaging technique that has enabled clear visualization of the teeth and surrounding structures. The most common diagnostic purpose of dental CBCT examination in children is ectopic eruption and impacted teeth, and a small field of view (FOV) is often used. Since it is difficult for children to control their body movements, reducing the rotation angle is effective. However, no studies have examined the effects of different rotation angles on radiation doses to highly radiosensitive organs in children using small FOVs. The purpose of this study was to examine the effects of small FOVs (4 × 4 cm and 6 × 6 cm) and rotation angles (360° and 180°) on doses that highly sensitize organs in children using dental CBCT. The entrance surface doses to lenses, thyroid lobes, parotid glands, and sublingual glands of a pediatric whole-body phantom were measured. By reducing the FOV from 6 × 6 cm to 4 × 4 cm, the dose to the sublingual gland could be significantly decreased. Additionally, by reducing the rotation angle from 360° to 180°, the lens dose can be decreased significantly. As the rate of dose reduction varies among organs, it is important to consider the relative positions of different organs with respect to the FOV and the trajectory of the X-ray tube.
- 9 October 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (19) , 9154
Open AccessEffects of Different Fields of View and Rotation Angles on Radiation Doses to Highly Radiosensitive Organs in Children Using Dental Cone Beam Computed Tomography
Dental cone beam computed tomography (CBCT) is a diverse 3D X-ray imaging technique that has enabled clear visualization of the teeth and surrounding structures. The most common diagnostic purpose of dental CBCT examination in children is ectopic eruption and impacted teeth, and a small field of view (FOV) is often used. Since it is difficult for children to control their body movements, reducing the rotation angle is effective. However, no studies have examined the effects of different rotation angles on radiation doses to highly radiosensitive organs in children using small FOVs. The purpose of this study was to examine the effects of small FOVs (4 × 4 cm and 6 × 6 cm) and rotation angles (360° and 180°) on doses that highly sensitize organs in children using dental CBCT. The entrance surface doses to lenses, thyroid lobes, parotid glands, and sublingual glands of a pediatric whole-body phantom were measured. By reducing the FOV from 6 × 6 cm to 4 × 4 cm, the dose to the sublingual gland could be significantly decreased. Additionally, by reducing the rotation angle from 360° to 180°, the lens dose can be decreased significantly. As the rate of dose reduction varies among organs, it is important to consider the relative positions of different organs with respect to the FOV and the trajectory of the X-ray tube.
- Open Access
- 1 January 2024
- Published by XMLink in Imaging Science in Dentistry
- Vol. 54 (2) , 201-206
Temporomandibular joint ankylosis suspected to be associated with ankylosing spondylitis based on cervical computed tomography images: A pictorial essay
Kojima I, et al. Imaging Sci Dent. 2024 Jun;54(2):201-206. https://doi.org/10.5624/isd.20230243
- 1 January 2024
- Published by XMLink in Imaging Science in Dentistry
- Vol. 54 (2) , 201-206
Open AccessTemporomandibular joint ankylosis suspected to be associated with ankylosing spondylitis based on cervical computed tomography images: A pictorial essay
Kojima I, et al. Imaging Sci Dent. 2024 Jun;54(2):201-206. https://doi.org/10.5624/isd.20230243