Sergey I. Kopylov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sergey I. Kopylov has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
N. N. Balashov
Joint Institute for High Temperatures, Russian Academy of Science, Moscow, Russia
3 shared publications- Pavel Nikolaevich Degtyarenko
Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow, Russia
2 shared publications S. S. Ivanov
Joint Institute for High Temperatures, Russian Academy of Science, Moscow, Russia
2 shared publicationsV. V. Zheltov
Joint Institute for High Temperatures, Russian Academy of Science, Moscow, Russia
2 shared publications- Victor E. Sytnikov
LLC CryoPowerSystems, Moscow, Russia
2 shared publications A. S. Veselovsky
Russian Acad. of Sci., Moscow
1 shared publication
Latest Publications
- 9 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-4
Investigation of an Opportunity of Using 2G HTS Tapes for High-Current Cables With a Current-Carrying Capacity More Than 10 kA
There had been considered optimized design versions of high-current three-phase HTS cables with 2G HTS tapes as current-carrying elements. Their characteristics (rms phase current 12 kA, line voltage 24 kV) conform to the parameters required for the first stage of the power transmission line from the generator to the first step-up transformer. Three types of cables are under consideration: one with screened phases and triaxial and flat, as well. The phase critical current value is taken 21 kA. For all the cables designs are given their exact geometric parameters together with the estimation of AC losses and HTS tapes consumption. It has been shown, that the optimization performed allows keeping up AC loses at a level acceptable for practical applications. The best design versions proposed have the losses within the range of 0.27–0.5 W/m, which are significantly lower than ones caused by the natural heat transfer into the cryostat – about 1–2 W/m, vs. its dimensions. All the cable types with one and the same design modification have an approximately equal level of losses. But triaxial and flat cables have an advantage in HTS tapes consumption.
- 9 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-4
Investigation of an Opportunity of Using 2G HTS Tapes for High-Current Cables With a Current-Carrying Capacity More Than 10 kA
There had been considered optimized design versions of high-current three-phase HTS cables with 2G HTS tapes as current-carrying elements. Their characteristics (rms phase current 12 kA, line voltage 24 kV) conform to the parameters required for the first stage of the power transmission line from the generator to the first step-up transformer. Three types of cables are under consideration: one with screened phases and triaxial and flat, as well. The phase critical current value is taken 21 kA. For all the cables designs are given their exact geometric parameters together with the estimation of AC losses and HTS tapes consumption. It has been shown, that the optimization performed allows keeping up AC loses at a level acceptable for practical applications. The best design versions proposed have the losses within the range of 0.27–0.5 W/m, which are significantly lower than ones caused by the natural heat transfer into the cryostat – about 1–2 W/m, vs. its dimensions. All the cable types with one and the same design modification have an approximately equal level of losses. But triaxial and flat cables have an advantage in HTS tapes consumption.
- 25 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 27 (4) , 1-6
Optimization of Three- and Single-Phase AC HTS Cables Design by Numerical Simulation
This paper presents the results of calculation of ac HTS cables designs optimized by the values of hysteresis and eddy current losses. The superconducting elements of the cables are 2G HTS tapes. The program we developed and used allowed the variation of both the cable shape and its internal structure. There have been considered nonsectioned and sectioned cables having two variants of geometry-the axially symmetrical coaxial and extended rectangular cross-sectional shape. It has been shown that the internal structure optimization allows decreasing of ac losses in several times for both cross-sectional shapes. Due to the compensation of the perpendicular magnetic field component, the characteristics of flat three-phase cables turn out to be close of those with the axially symmetrical cross-sectional shape. In this case, the rectangular cross-sectional shape allows obtaining better mass, dimensional, and mechanical parameters and better cooling conditions of phases. The cables sectioning allows an essential reduction of ac losses. But, the latter is possible only when there is a uniform current distribution over the sections, i.e., at a very exact design calculation.
- 25 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 27 (4) , 1-6
Optimization of Three- and Single-Phase AC HTS Cables Design by Numerical Simulation
This paper presents the results of calculation of ac HTS cables designs optimized by the values of hysteresis and eddy current losses. The superconducting elements of the cables are 2G HTS tapes. The program we developed and used allowed the variation of both the cable shape and its internal structure. There have been considered nonsectioned and sectioned cables having two variants of geometry-the axially symmetrical coaxial and extended rectangular cross-sectional shape. It has been shown that the internal structure optimization allows decreasing of ac losses in several times for both cross-sectional shapes. Due to the compensation of the perpendicular magnetic field component, the characteristics of flat three-phase cables turn out to be close of those with the axially symmetrical cross-sectional shape. In this case, the rectangular cross-sectional shape allows obtaining better mass, dimensional, and mechanical parameters and better cooling conditions of phases. The cables sectioning allows an essential reduction of ac losses. But, the latter is possible only when there is a uniform current distribution over the sections, i.e., at a very exact design calculation.
- 18 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 25 (3) , 1-4
The Effect of Sectioning on the Characteristics of Resistive Superconducting Fault Current Limiter
This paper introduces a new design solution for the high-power superconducting fault current limiter (SFCL). The device consists of concentric sections with a circular cross-section shape which are connected in series in such a way that the current in adjacent sections flows in mutually opposite directions. The analysis of efficiency of various designs and optimization of their geometry and dimensions was performed through numerical simulations. They show that the higher number of sections gives the ability to substantially decrease the amount of superconducting materials and to reduce hysteresis losses.
- 18 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 25 (3) , 1-4
The Effect of Sectioning on the Characteristics of Resistive Superconducting Fault Current Limiter
This paper introduces a new design solution for the high-power superconducting fault current limiter (SFCL). The device consists of concentric sections with a circular cross-section shape which are connected in series in such a way that the current in adjacent sections flows in mutually opposite directions. The analysis of efficiency of various designs and optimization of their geometry and dimensions was performed through numerical simulations. They show that the higher number of sections gives the ability to substantially decrease the amount of superconducting materials and to reduce hysteresis losses.
- 23 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 17 (2) , 1799-1802
The Effect of Sectioning on Superconducting Fault Current Limiter Operation
Various types of fault currents limiters have been proposed to reduce the fault currents in power transmission lines. The transformer type superconducting (SC) fault current limiter is one of them and has many advantages such as design flexibility. In normal operation mode the impedance is that of short-circuit transformer and has its minimum value. In the event of a load to fault an increase of the primary winding current causing a subsequent current increasing in the secondary SC winding (ring) and its quenching to the normal state. In this case the impedance turns to one in a no-load operation mode, i.e. is maximal performing the fault current limitation in the circuit to be protected. There has been investigated an effect of this sectioning of short-circuit SC windings or rings on the operation. A configuration of the transformer with symmetrical alternatively positioned disc windings is shown to be the optimal.
- 23 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 17 (2) , 1799-1802
The Effect of Sectioning on Superconducting Fault Current Limiter Operation
Various types of fault currents limiters have been proposed to reduce the fault currents in power transmission lines. The transformer type superconducting (SC) fault current limiter is one of them and has many advantages such as design flexibility. In normal operation mode the impedance is that of short-circuit transformer and has its minimum value. In the event of a load to fault an increase of the primary winding current causing a subsequent current increasing in the secondary SC winding (ring) and its quenching to the normal state. In this case the impedance turns to one in a no-load operation mode, i.e. is maximal performing the fault current limitation in the circuit to be protected. There has been investigated an effect of this sectioning of short-circuit SC windings or rings on the operation. A configuration of the transformer with symmetrical alternatively positioned disc windings is shown to be the optimal.