Tejas Guruswamy has a total of 89 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Lab Characterization of the Soft X-Ray Transition Edge Spectrometer Sensor Array for the Advanced Photon Source

    by Tejas Guruswamy, Orlando Quaranta, Danielle Riekse, Jad Panjaitan, Lisa Gades, Kelsey Morgan, Joel Weber, Daniel Swetz, Antonino Miceli

    Soft X-ray resonant scattering is a sensitive probe of electronic, magnetic, and orbital order, but its weak signals are often embedded in substantial elastic, inelastic, and fluorescence backgrounds. In order to enable new science at the Advanced Photon Source (APS) X-ray synchrotron, we have developed a transition edge sensor array-based spectrometer instrument optimized for energy-resolved detection in the 0.2 to 2keV band, sustained operation at elevated photon count rates, and a mechanical design that allows for a small sensor–sample distance without interfering with existing hardware. The newly fabricated 256-pixel sensor array consists of sidecar Mo/Au transition edge sensors with Bi/Au absorbers, packaged onto a microsnout platform with frequency multiplexed $\mu$Mux readout. We report on laboratory characterization of this array prior to final instrument integration and beamline deployment. DC current–voltage measurements establish acceptable uniformity and yield but identify a higher than intended bilayer critical temperature. Readout characterization shows the majority of $\mu$Mux channels operating in a regime compatible with TESlimited energy resolution. Soft Xray spectral measurements using a lab X-ray source demonstrate a fullwidthathalfmaximum energy resolution median across the array of 2.3eV at Al K$\alpha$ (1.5keV), with almost 80% of all pixels producing spectra with resolution below 3eV. The larger than targeted energy resolution is primarily attributed to a reduced resistance sensitivity to temperature ($\alpha$) relative to the prototype designs. Overall the results indicate the spectrometer meets the minimum requirements for resonant soft X-ray scattering and related measurements at the APS. Immediate next steps focus on commissioning of the instrument at the beamline, validation of high countrate operation, and establishment of energy calibration and data analysis workflows tailored to soft X-ray science.

  • Thermal Crosstalk in 24-Pixel Hard X-Ray TES Arrays: Comparative Experiments and Multibody Simulations

    by Panthita Triamkitsawat, Orlando Quaranta, Tejas Guruswamy, Umeshkumar Patel, Lisa Gades, Jonathan Baldwin, Antonino Miceli

    In this study, we conducted simulations and experimental characterization of thermal crosstalk in a hard X-ray transition-edge sensor (TES) array. TESs are low-temperature superconducting detectors with excellent energy resolution, making them ideal for synchrotron applications. To achieve the required count rate and collecting area, TES detectors are typically organized into multi-pixel arrays. However, tight pixel spacing and multiplexing can introduce thermal and electrical crosstalk that degrades spectral resolution at high photon rates. We characterized the crosstalk phenomena between X-ray TESs in a 24-pixel array. This TES array, fabricated at the Argonne National Laboratory (ANL), is designed to operate in the tens of keV regime. In prior work, we experimentally developed procedures and algorithms to identify and quantify crosstalk in various setups. To further explain the phenomenon, we created a multibody model to simulate the thermal crosstalk response between neighboring TES pixels. Simulations correlate the observed thermal crosstalk with key device properties: material composition, TES transition shape parameters ($\alpha$ and $\beta$), and intrinsic characteristics such as heat capacity and thermal conductance.

  • Temperature Dependence of Resistivity and Noise in Electrodeposited Bismuth Samples for X-ray Transition-Edge Sensors

    by A. Mauro, O. Quaranta, N. Coppola, L. Gades, A. Galdi, M. G. Adesso, T. Guruswamy, L. Maritato, A. Miceli, S. Pagano, et al.

    A combination of gold and bismuth is commonly used as absorber for X-ray transition-edge sensors, due to high atomic numbers and, consequently large cross sections, and to their complementary thermal properties. Since Au conductivity dominates, especially at cryogenic temperatures, electrodeposited bismuth films have been grown over sputtered gold, so that bismuth forms a bridge on the gold fingers and, therefore, the conductivity contribution from the underlying Au layer can be removed. Resistance as a function of the temperature has been investigated for pristine and annealed samples, both with and without a dc magnetic field. A general behavior has been observed, thus evidencing three different zones. At high temperatures a metal regime, described in terms of a Fermi liquid model, is identified. In an intermediate temperature region, a hysteretic and irreversible insulating-type resistance is observed. While, at low temperatures a resistance plateau appears. To better understand the electrical conduction properties, noise measurements have been also performed. Two possible models have been considered to interpret experimental data in the intermediate temperature region: Fluctuation-Induced Tunneling and Quantum Interference Effects. The analysis here reported gives indication on the granular structure of the investigated films, which could be represented as random networks of tunneling junctions, where the nodes are the conducting pathways connecting different junctions. In these regions, temperature-induced intergranular processes could be effectively detected giving additional information on the prediction of the ultimate energy resolving capabilities of detectors with bismuth absorbers.

  • A 28 nm multiply-accumulate ASIC architecture for on-chip data compression in MHz frame rate X-ray and electron pixel detectors

    by Rami Rasheedi, Nicholas Contini, Mohamed Adel Gharib, Sebastian Strempfer, Senthil Gnanasekaran, Salma Abdelzaher, Tejas Guruswamy, Kazutomo Yoshii, Mike Hammer, Henry Shi, et al.

    Modern X-ray detector systems urgently require compact, efficient, and fast data compression schemes to handle the transmission of big data from pixel arrays, enabling frame rates in the MHz regime. In this work, a data compression ASIC that implements a streaming fixed-length lossy compression scheme is introduced and analyzed, proving the feasibility and benefits of on-chip compression. The compression scheme utilizes a vector matrix product logic, which performs a number of floating-point multiplications, additions, and accumulations. The logic is verified, synthesized, and shown to fit in the area resource available for the X-ray detector under study, which comprises 192 × 168 pixels each of 12-bit width, and having a total area of 20 mm× 20 mm, about 2 mm× 20 mm of which are available for the digital logic. Several system architectures, precisions, and compression ratios ranging from 100 to 250 were analyzed to pave the way for on-chip fixed-length compression (e.g., principal component analysis, singular value decomposition) and data reduction (e.g., azimuthal integration) for X-ray and electron detectors.


  • Controlled Shifts Of X-Ray Emission Lines Measured With Transition Edge Sensors at the Advanced Photon Source

    by Tejas Guruswamy, Orlando Quaranta, Lisa Gades, Umeshkumar Patel, Antonino Miceli

    The measurement of shifts in the energy of X-ray emission lines is important for understanding the electronic structure and physical properties of materials. In this study, we demonstrate a method using a synchrotron source to introduce controlled eV-scale shifts of a narrow line in between fixed-energy fluorescence lines. We use this to characterize the ability of a hard X-ray superconducting Transition Edge Sensor (TES) array to measure line shifts. Fixed fluorescence lines excited by higher harmonics of the monochromatic X-ray beam are used for online energy calibration, while elastic scattering from the primary harmonic acts as the variable energy emission line under study. We use this method to demonstrate the ability to track shifts in the energy of the elastic scattering line of magnitude smaller than the TES energy resolution, and find we are ultimately limited by our calibration procedure. The method can be applied over a wide X-ray energy range and provides a robust approach for the characterization of the ability of high-resolution detectors to detect X-ray emission line shifts, and the quantitative comparison of energy calibration procedures.


  • Open Access

    Controlled Shifts of X-ray Emission Lines Measured with Transition Edge Sensors at the Advanced Photon Source

    by Tejas Guruswamy, Orlando Quaranta, Lisa Gades, Umeshkumar Patel, Antonino Miceli

    The measurement of shifts in the energy of X-ray emission lines is important for understanding the electronic structure and physical properties of materials. In this study, we demonstrate a method using a synchrotron source to introduce controlled eV-scale shifts of a narrow line in between fixed-energy fluorescence lines. We use this to characterize the ability of a hard X-ray superconducting Transition Edge Sensor (TES) array to measure line shifts. Fixed fluorescence lines excited by higher harmonics of the monochromatic X-ray beam are used for online energy calibration, while elastic scattering from the primary harmonic acts as the variable energy emission line under study. We use this method to demonstrate the ability to track shifts in the energy of the elastic scattering line of magnitude smaller than the TES energy resolution, and find we are ultimately limited by our calibration procedure. The method can be applied over a wide X-ray energy range and provides a robust approach for the characterization of the ability of high-resolution detectors to detect X-ray emission line shifts, and the quantitative comparison of energy calibration procedures.

  • A High-Speed, High-Resolution Transition Edge Sensor Spectrometer for Soft X-Rays at the Advanced Photon Source

    by Orlando Quaranta, Don Jensen, Kelsey Morgan, Joel C. Weber, Jessica L. McChesney, Hao Zheng, Tejas Guruswamy, Jonathan Baldwin, Ben Mates, Nathan Ortiz, et al.

    This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X-ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.


  • Open Access

    Extracting the electronic structure of light elements in bulk materials through a Compton scattering method in the readily accessible hard x-ray regime

    by Veenavee Nipunika Kothalawala, Tejas Guruswamy, Orlando Quaranta, Umeshkumar Manibhai Patel, Lisa Gades, Keith Taddei, Andrey Yakovenko, Meiying Zheng, Kelsey Morgan, Joel Weber, et al.

    Our Compton profile measurements of Ti and TiH2 using readily available hard X-ray radiation at 27.5 keV, detected by both a Hitachi Vortex silicon-drift detector and a high-resolution superconducting transition-edge sensor array, are found to be in excellent accord with state-of-the-art density functional theory based calculations. The spherically averaged difference between the Compton profiles of TiH2 and Ti is well described by an inverted parabola, supporting an itinerant behavior of the electron gas screening the protons in the Ti matrix. Our experimental approach, validated by two different detectors, extends the applicability of Compton scattering technique to the readily accessible hard x-ray regime (below 30 keV). Our study suggests possibilities for experiments at low-flux bending magnet synchrotron beamlines and paves the way for the development of tabletop Compton experiments with x-ray tubes.


  • Signatures of Thermal and Electrical Crosstalk in a Microwave Multiplexed Hard X-ray Transition Edge Sensor Array

    by Panthita Triamkitsawat, Tejas Guruswamy, Orlando Quaranta, Lisa Gades, Umeshkumar Patel, Antonino Miceli


  • Open Access

    Signatures of Thermal and Electrical Crosstalk in a Microwave Multiplexed Hard X-ray Transition Edge Sensor Array

    by Panthita Triamkitsawat, Tejas Guruswamy, Orlando Quaranta, Lisa Gades, Umeshkumar Patel, Antonino Miceli

    We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a prototype 24-pixel hard X-ray array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated with insufficient thermalization, and rare but large in magnitude electrical crosstalk between specific perpetrator-victim pixel combinations, potentially due to deficiencies in the bias wiring or microwave multiplexing circuit. We use a method based on group triggering and averaging to isolate the crosstalk response despite only having access to X-ray photon illumination uniform across the entire array. This allows us to identify thermal and electrical crosstalk between pixel pairs in repeated measurements to the level of 1 part in 1000 or better. In the array under study, the magnitude of observed crosstalk is small but comparable to the resolving power of this pixel design (E/$Δ$E $\sim$ 1000 at 20 keV) and so potentially responsible for a degradation in energy resolution of the array at high incident photon rates. Having proven the methods to identify and quantify crosstalk in our setup, we can consider mitigations.