Ashley M. Pierce
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ashley M. Pierce has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
S. Marcela Loría-Salazar
4 shared publications- Grant C. Edwards
Faculty of Science and Engineering, Department of Environmental Science, Macquarie University, Sydney, NSW, 2113, Australia
2 shared publications Mae S. Gustin
2 shared publicationsMae Sexauer Gustin
Department of Natural Resources and Environmental Sciences, University of Nevada Reno, NV, USA 89557
2 shared publicationsMatthieu B. Miller
Department of Environmental Sciences, Faculty of Science and Engineering, Macquarie University, Sydney, New South Wales, Australia
2 shared publicationsW. Patrick Arnott
Atmospheric Science Program, Department of Physics, University of Nevada Reno, NV 89557, USA
2 shared publications
Latest Publications
- 1 January 2019
- Published by Elsevier in Atmospheric Environment
- Vol. 196, 103-117
Investigating horizontal and vertical pollution gradients in the atmosphere associated with an urban location in complex terrain, Reno, Nevada, USA
- 1 January 2019
- Published by Elsevier in Atmospheric Environment
- Vol. 196, 103-117
Investigating horizontal and vertical pollution gradients in the atmosphere associated with an urban location in complex terrain, Reno, Nevada, USA
- Open Access
- 18 April 2018
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 11 (4) , 2225-2237
Aggregated particles caused by instrument artifact
Previous studies have indicated that superaggregates, clusters of aggregates of soot primary particles, can be formed in large-scale turbulent fires. Due to lower effective densities, higher porosity, and lower aerodynamic diameters, superaggregates may pass through inlets designed to remove particles < 2.5 µm in aerodynamic diameter (PM2.5). Ambient particulate matter samples were collected at Peavine Peak, NV, USA (2515 m) northwest of Reno, NV, USA from June to November 2014. The Teledyne Advanced Pollution Instrumentation (TAPI) 602 BetaPlus particulate monitor was used to collect PM2.5 on two filter types. During this time, aggregated particles > 2.5 µm in aerodynamic diameter were collected on 36 out of 158 sample days. On preliminary analysis, it was thought that these aggregated particles were superaggregates, depositing past PM10 (particles < 10 µm in aerodynamic diameter) pre-impactors and PM2.5 cyclones. However, further analysis revealed that these aggregated particles were dissimilar to superaggregates observed in previous studies, both in morphology and in elemental composition. To determine if the aggregated particles were superaggregates or an instrument artifact, samples were investigated for the presence of certain elements, the occurrence of fires, high relative humidity and wind speeds, as well as the use of generators on site. Samples with aggregated particles, referred to as aggregates, were analyzed using a scanning electron microscope for size and shape and energy dispersive X-ray spectroscopy was used for elemental analysis. It was determined, based on the high amounts of aluminum present in the aggregate samples, that a sampling artifact associated with the sample inlet and prolonged, high wind events was the probable reason for the observed aggregates.
- 18 April 2018
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 11 (4) , 2225-2237
Open AccessAggregated particles caused by instrument artifact
Previous studies have indicated that superaggregates, clusters of aggregates of soot primary particles, can be formed in large-scale turbulent fires. Due to lower effective densities, higher porosity, and lower aerodynamic diameters, superaggregates may pass through inlets designed to remove particles < 2.5 µm in aerodynamic diameter (PM2.5). Ambient particulate matter samples were collected at Peavine Peak, NV, USA (2515 m) northwest of Reno, NV, USA from June to November 2014. The Teledyne Advanced Pollution Instrumentation (TAPI) 602 BetaPlus particulate monitor was used to collect PM2.5 on two filter types. During this time, aggregated particles > 2.5 µm in aerodynamic diameter were collected on 36 out of 158 sample days. On preliminary analysis, it was thought that these aggregated particles were superaggregates, depositing past PM10 (particles < 10 µm in aerodynamic diameter) pre-impactors and PM2.5 cyclones. However, further analysis revealed that these aggregated particles were dissimilar to superaggregates observed in previous studies, both in morphology and in elemental composition. To determine if the aggregated particles were superaggregates or an instrument artifact, samples were investigated for the presence of certain elements, the occurrence of fires, high relative humidity and wind speeds, as well as the use of generators on site. Samples with aggregated particles, referred to as aggregates, were analyzed using a scanning electron microscope for size and shape and energy dispersive X-ray spectroscopy was used for elemental analysis. It was determined, based on the high amounts of aluminum present in the aggregate samples, that a sampling artifact associated with the sample inlet and prolonged, high wind events was the probable reason for the observed aggregates.
- 1 February 2018
- Published by Elsevier in Science of The Total Environment
- Vol. 615, 1411-1427
Use of multiple tools including lead isotopes to decipher sources of ozone and reactive mercury to urban and rural locations in Nevada, USA
- 1 February 2018
- Published by Elsevier in Science of The Total Environment
- Vol. 615, 1411-1427
Use of multiple tools including lead isotopes to decipher sources of ozone and reactive mercury to urban and rural locations in Nevada, USA
- Open Access
- 1 December 2017
- Published by Copernicus GmbH in EGUsphere
- Vol. 2017, 1-25
Superaggregates or instrument artifact?
Previous studies have indicated that superaggregates, clusters of aggregates of soot primary particles, can be formed in large-scale turbulent fires. High intensity fires may also produce the right circumstances to inject plumes into the upper troposphere and lower stratosphere during pyrocumulonimbus thunderstorms, where the superaggregates can then be transported long distances. Due to lower effective densities, higher porosity, and lower aerodynamic diameters, superaggregates may be deposited past inlets designed to stop particles < 2.5 µm in aerodynamic diameter (PM2.5). Ambient particulate matter samples were collected at Peavine Peak, NV, USA (2515 m) northwest of Reno, NV, USA from June to November 2014. The Teledyne Advanced Pollution Instrumentation (TAPI) 602 BetaPlus particulate monitor was used to collect PM2.5 on two filter types. During this time, particles > 2.5 µm in aerodynamic diameter were collected on 36 days. On preliminary analysis, it was thought that these particles were superaggregates, depositing past PM10 (particles < 10 µm in aerodynamic diameter) pre-impactors and PM2.5 cyclones. However, further analysis revealed that these particles were dissimilar to superaggregates observed in previous studies. To determine if the particles were superaggregates or an instrument artifact, elemental analysis, presence of fires, high relative humidity and wind speeds, as well as the use of generators onsite were investigated. Samples with aggregates were analyzed using a scanning electron microscope for size and shape of the aggregates and energy-dispersive x-ray spectroscopy was used for elemental analysis. It was determined that a sampling artifact associated with sample inlet setup and prolonged, high wind events were the probably reason for the observed aggregates.
- 1 December 2017
- Published by Copernicus GmbH in EGUsphere
- Vol. 2017, 1-25
Open AccessSuperaggregates or instrument artifact?
Previous studies have indicated that superaggregates, clusters of aggregates of soot primary particles, can be formed in large-scale turbulent fires. High intensity fires may also produce the right circumstances to inject plumes into the upper troposphere and lower stratosphere during pyrocumulonimbus thunderstorms, where the superaggregates can then be transported long distances. Due to lower effective densities, higher porosity, and lower aerodynamic diameters, superaggregates may be deposited past inlets designed to stop particles < 2.5 µm in aerodynamic diameter (PM2.5). Ambient particulate matter samples were collected at Peavine Peak, NV, USA (2515 m) northwest of Reno, NV, USA from June to November 2014. The Teledyne Advanced Pollution Instrumentation (TAPI) 602 BetaPlus particulate monitor was used to collect PM2.5 on two filter types. During this time, particles > 2.5 µm in aerodynamic diameter were collected on 36 days. On preliminary analysis, it was thought that these particles were superaggregates, depositing past PM10 (particles < 10 µm in aerodynamic diameter) pre-impactors and PM2.5 cyclones. However, further analysis revealed that these particles were dissimilar to superaggregates observed in previous studies. To determine if the particles were superaggregates or an instrument artifact, elemental analysis, presence of fires, high relative humidity and wind speeds, as well as the use of generators onsite were investigated. Samples with aggregates were analyzed using a scanning electron microscope for size and shape of the aggregates and energy-dispersive x-ray spectroscopy was used for elemental analysis. It was determined that a sampling artifact associated with sample inlet setup and prolonged, high wind events were the probably reason for the observed aggregates.
- 14 December 2016
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 51 (1) , 436-445
Development of a Particulate Mass Measurement System for Quantification of Ambient Reactive Mercury
The Teledyne Advanced Pollution Instrumentation (TAPI) model 602 BetaPlus particulate system provides nondestructive analysis of particulate matter (PM2.5) mass concentration. This instrument was used to determine if measurements made with cation exchange membranes (CEM) were comparable to standard methods, the β attenuation method at two locations in Reno, NV and an environmental β attenuation method and gravimetric method at Great Basin National Park, NV. TAPI PM2.5 CEM measurements were statistically similar to the other three PM2.5 methods. Once this was established, the second objective, a destructive method for measurement of reactive mercury (RM = gaseous oxidized and particulate bound Hg), was tested. Samples collected at 16.7 L per min (Lpm) for 24 h on CEM from the TAPI were compared to those measured by the University of Nevada, Reno-Reactive Mercury Active System (UNRRMAS, 1 Lpm) CEM and a Tekran 2537/1130/1135 system (7 Lpm). Given the use of CEM in the TAPI and UNRRMAS, we hypothesized that both should collect RM. Due to the high flow rate and different inlets, TAPI data were systematically lower than the UNRRMAS. Correlation between RM concentrations demonstrated that the TAPI may be used to estimate 24 h resolution RM concentrations in Nevada.
- 14 December 2016
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 51 (1) , 436-445
Development of a Particulate Mass Measurement System for Quantification of Ambient Reactive Mercury
The Teledyne Advanced Pollution Instrumentation (TAPI) model 602 BetaPlus particulate system provides nondestructive analysis of particulate matter (PM2.5) mass concentration. This instrument was used to determine if measurements made with cation exchange membranes (CEM) were comparable to standard methods, the β attenuation method at two locations in Reno, NV and an environmental β attenuation method and gravimetric method at Great Basin National Park, NV. TAPI PM2.5 CEM measurements were statistically similar to the other three PM2.5 methods. Once this was established, the second objective, a destructive method for measurement of reactive mercury (RM = gaseous oxidized and particulate bound Hg), was tested. Samples collected at 16.7 L per min (Lpm) for 24 h on CEM from the TAPI were compared to those measured by the University of Nevada, Reno-Reactive Mercury Active System (UNRRMAS, 1 Lpm) CEM and a Tekran 2537/1130/1135 system (7 Lpm). Given the use of CEM in the TAPI and UNRRMAS, we hypothesized that both should collect RM. Due to the high flow rate and different inlets, TAPI data were systematically lower than the UNRRMAS. Correlation between RM concentrations demonstrated that the TAPI may be used to estimate 24 h resolution RM concentrations in Nevada.