Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fabienne Jordana has a total of 87 co-authors. Here are the top co-authors by number of shared publications:

  • Raoul Bationo

    Service de Chirurgie Dentaire, CHU de Bogodogo, Ouagadougou, Burkina Faso, West Africa

    6 shared publications
  • Abdoulaziz Diarra

    CHU de Tengandogo/UFR Sciences de la Santé Université Joseph Ki‐Zerbo Ouagadougou Burkina Faso

    2 shared publications
  • Jacques Colat-Parros

    Pôle d'Odontologie et de Santé buccale, Hôpital Pellegrin, Bordeaux, France; UFR d'Odontologie, Université de Bordeaux, Bordeaux, France

    2 shared publications
  • Marie-José Boileau

    Pôle d'Odontologie et de Santé buccale, Hôpital Pellegrin, Bordeaux, France; UFR d'Odontologie, Université de Bordeaux, Bordeaux, France

    2 shared publications
  • Pierre Weiss

    Nantes Université, Univ Angers, Oniris, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, RMeS, UMR 1229 Nantes France

    2 shared publications
  • A A Kouadio

    1 shared publication

Latest Publications

  • Fracturation sur os frais ou sur os sec de la voûte crânienne : approche méthodologique et application archéologique

    by Fabienne Jordana

    Etablir le diagnostic différentiel entre des fractures réalisées sur os frais de celles produites sur os sec permet, quelle que soit la période chronologique considérée, une approche interprétative relative à l’attitude comportementale humaine qu’ils s’agissent des relations au sein d’un groupe ou face à une autre population, ainsi que les gestes réservés aux morts. Ainsi peuvent être envisagés le cannibalisme, des comportements de violence, ou des pratiques funéraires originales. Si certaines méthodes analytiques existaient pour le squelette infracrânien, aucun référentiel permettant de différentier les fractures sur os frais (intentionnelles ou non) des cassures sur os secs n’est actuellement disponible pour le squelette crânien. Notre objectif de recherche s’est donc concentré sur un essai de détermination des critères statistiquement valides de distinction du moment de fracturation sur os fossiles. Une partie importante de ce travail est consacrée aux études expérimentales menées pour tenter de distinguer une différence de comportement mécanique entre une fracture réalisée sur os frais de celle réalisée sur os sec (essais mécaniques, rugosimétrie confocale, microtomographie ou numérisation des pièces osseuses). Puis, les critères de la médecine légale sont discutés à partir d’échantillons osseux provenant de séries archéologiques différentes d’un point de vue chronologique et géographique et relevant de problématiques différentes. Il ressort de ce travail que très peu de critères pris individuellement sont suffisamment pertinents pour différencier fracturation sur os frais et fracturation sur os sec (décollement de la lame corticale). Ils doivent toujours être discutés à l’échelle d’une série archéologique et non sur un échantillon isolé, seul ou sorti de son contexte. Dans le meilleur des cas, ils nous permettent de proposer des hypothèses (cannibalisme, pression des sédiments…) qui devront être corroborées en fonction du contexte archéologique et anthropologique par une analyse interdisciplinaire.

  • Open Access

    Implant Health in Treated Periodontitis Patients: A Systematic Review and Meta-Analysis

    by Léa Marty, Alain Hoornaert, Bénédicte Enkel, Alan Penhoat, Jacques Colat-Parros, Assem Soueidan, Fabienne Jordana

    Background: The aim of this meta-analysis was to evaluate the role of a history of periodontitis on implant failure. The two main judgment criteria studied are peri-implantitis and the survival rate. The two secondary judgment criteria studied are the mean pocket depth and the mean peri-implant bone loss. Methods: An electronic search was performed via five databases (MEDLINE, Embase, ScienceDirect, LILACS and the Cochrane Library) and was supplemented by manual searching. The search was undertaken in June 2024. Results: Of 10 775 potentially eligible articles, 8 were included in the qualitative analysis and 10 in the quantitative synthesis. Conclusions: This meta-analysis suggests that a history of periodontitis has a significant impact on the rate of peri-implantitis, survival rate, mean bone loss and pocket depth.


  • Open Access

    Une analyse des propriétés de l’échelle de mesure des manifestations du bien-être psychologique auprès d’étudiants français inscrits en première année d’études de santé et en odontologie1

    by Pauline Mourlon, Lise Blanchard, Tanguy Guenneugues, Philippine Loustaunau, Fabienne Jordana, Benedicte Enkel, Gilles Guihard

    L’évaluation du bien-être des étudiants fait l’objet de nombreuses recherches de la part des universités. Toutefois, il existe peu de données concernant la mesure du bien-être chez des étudiants inscrits en formation de santé en France. Ici, les propriétés de l’échelle de mesure de la manifestation du bien-être psychologique (EMMBEP) ont été réanalysées dans trois échantillons d’étudiants inscrits en formation de santé. Les résultats ont montré que 23 items contribuaient à la mesure du bien-être. Ces items reflétaient une structure à trois facteurs. L’échelle et ses facteurs présentaient une très bonne cohérence interne et était invariante selon le sexe ou la formation académique. En conclusion, ce travail fournit de bons arguments pour considérer l’EMMBEP23 comme un instrument de mesure fidèle et satisfaisant plusieurs critères de validité de construit. Par ailleurs, il suggère que la structure du bien-être a évolué ; les causes de ce changement sont discutées.


  • Open Access

    Evaluation of Mental Foramen with Cone Beam Computed Tomography: A Systematic Review of Literature

    by Antoinette Pelé, Pierre-Alexandre Berry, Charles Evanno, Fabienne Jordana

    Purpose. The aim of this systematic review is to assess whether the anatomy of mental foramen is precisely evaluable with cone beam computed tomography (CBCT) before implantation in humans. Methods. A systematic review was carried out to evaluate the anatomy of mental foramen (size, position, symmetry, anterior loop, and accessory mental foramen or multiple mental foramina). According to Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines, an electronic search of three databases (Medline, Web of Science, and Cochrane Library) was undertaken until June 2020 and was supplemented by manual searching. Two reviewers will independently perform the processes of study inclusion, data extraction, and quality assessment. Systematic reviews, studies about children, and case reports were excluded. Only studies using CBCT to do preoperative evaluation were selected. Results. From 728 potentially eligible articles, 72 were included in the qualitative analysis and quantitative synthesis. This systematic review provided an assessment of the anatomy of the mental foramen. The mental foramen was located mostly between the two premolars (between 50.4 and 61.95) or apically to the second premolar (from 50.3 to 57.9). The mean diameter of the mental foramen was bigger in males than in females; the difference between them could reach 0.62mm. The anterior loop seemed to be longer in males (between 0.87±1.81 and 7.25±2.02mm) than in females (between 0.81±1.18 and 6.52±1.63mm) and with the presence of teeth (from 0.91±1.18 to 2.55±1.28 for dentate people and from 0.25±0.61 to 2.40±0.88mm for edentate population). The anterior loop and the accessory mental foramina were detected more frequently with CBCT than panoramic X-ray: only between 0.0 and 48.6 AMFs detected with CBCT were also seen with panoramic images. Clinical Significance. The mental foramen (MF) is an important landmark for local anesthesia and surgical and implantology procedures. Its location, morphology, and anatomical variations need to be considered to avoid mental nerve injury. The aim of this review is to evaluate the mental foramen using CBCT through a systematic literature review to improve knowledge of this complex area for the clinician.


  • Open Access

    Tissue Engineering and Three-Dimensional Printing in Periodontal Regeneration: A Literature Review

    by Simon Raveau, Fabienne Jordana

    The three-dimensional printing of scaffolds is an interesting alternative to the traditional techniques of periodontal regeneration. This technique uses computer assisted design and manufacturing after CT scan. After 3D modelling, individualized scaffolds are printed by extrusion, selective laser sintering, stereolithography, or powder bed inkjet printing. These scaffolds can be made of one or several materials such as natural polymers, synthetic polymers, or bioceramics. They can be monophasic or multiphasic and tend to recreate the architectural structure of the periodontal tissue. In order to enhance the bioactivity and have a higher regeneration, the scaffolds can be embedded with stem cells and/or growth factors. This new technique could enhance a complete periodontal regeneration. This review summarizes the application of 3D printed scaffolds in periodontal regeneration. The process, the materials and designs, the key advantages and prospects of 3D bioprinting are highlighted, providing new ideas for tissue regeneration.


  • Open Access

    Silanization of Chitosan and Hydrogel Preparation for Skeletal Tissue Engineering

    by Gildas Réthoré, Cécile Boyer, Kouakou Kouadio, Amadou Toure, Julie Lesoeur, Boris Halgand, Fabienne Jordana, Jérôme Guicheux, Pierre Weiss

    Tissue engineering is a multidisciplinary field that relies on the development of customized biomaterial to support cell growth, differentiation and matrix production. Toward that goal, we designed the grafting of silane groups onto the chitosan backbone (Si-chito) for the preparation of in situ setting hydrogels in association with silanized hydroxypropyl methylcellulose (Si-HPMC). Once functionalized, the chitosan was characterized, and the presence of silane groups and its ability to gel were demonstrated by rheology that strongly suggests the presence of silane groups. Throughout physicochemical investigations, the Si-HPMC hydrogels containing Si-chito were found to be stiffer with an injection force unmodified. The presence of chitosan within the hydrogel has demonstrated a higher adhesion of the hydrogel onto the surface of tissues. The results of cell viability assays indicated that there was no cytotoxicity of Si-chito hydrogels in 2D and 3D culture of human SW1353 cells and human adipose stromal cells, respectively. Moreover, Si-chito allows the transplantation of human nasal chondrocytes in the subcutis of nude mice while maintaining their viability and extracellular matrix secretory activity. To conclude, Si-chito mixed with Si-HPMC is an injectable, self-setting and cytocompatible hydrogel able to support the in vitro and in vivo viability and activity of hASC.


  • Open Access

    Cytotoxicity evaluation of dental and orthodontic light‐cured composite resins

    by Raoul Bationo, Ablassé Rouamba, Abdoulaziz Diarra, Monique Lydie Ahia Beugré‐Kouassi, Jean‐Bertin Beugré, Fabienne Jordana

    Introduction: The aim of this study was to determine the cytotoxicity of light‐cured composite resins (Clearfil ES‐2, Clearfil ES Flow, Filtek Supreme XTE, Grengloo, Blugloo, Transbond XT, and Transbond LR) then to assess leachable components in contact with human gingival fibroblasts (GFs) and to quantity detected bisphenol A (BPA).Methods: Light‐cured composite resin discs were immersed for 24 hours in gingival fibroblastic medium (n = 3 for each product) and in control medium (n = 2 for each product) contained in plate. Cytotoxicity of the products (n = 95) was determined by the measure of cell viability using MTT assay after reading the optical densities of the plates. The analysis of leachable components was done by gas phase chromatography and mass spectrometry (GC–MS) and detected BPA was quantified. The limit of quantification was 0.01 μg/mL. Statistical analyses were performed by using IBM SPSS Statistics 20 and Kruskal–Wallis and Mann–Whitney U‐tests were applied.Results: Cell viabilities were between 85 and 90%. Many chemical compounds including triethylene glycol dimethacrylate (TEGDMA) and BPA were identified. The average concentrations were 0.67 μg/mL ± 0.84 in the control medium and 0.73 μg/mL ± 1.05 in the fibroblastic medium. Filtek Supreme XTE presented the highest concentration of BPA with 2.16 μg/mL ± 0.65 and Clearfil ES Flow presented the lowest with 0.25 μg/mL ± 0.35. No BPA was detected with Transbond XT and Transbond LR. Clearfil ES Flow, Filtek Supreme XTE, Grengloo and Transbond LR presented residual TEGDMA.Conclusions: Light‐cured composite resins are slightly cytotoxic opposite GFs and release many components including BPA and TEGDMA. Clinical precautions should be taken to decrease the release of these monomers.


  • Open Access

    Culture of Human Gingival Fibroblasts: An Experimental Model

    by Raoul Bationo, Ablassé Rouamba, Abdoulaziz Diarra, Monique Lydie Beugré-Kouassi, Fabienne Jordana, Jean-Bertin Beugré

    Cell culture is an important tool in medical, odontological and biological research laboratories, supporting cell therapies and tissue bioengineering strategies. It is used as a means for in vitro testing of the biocompatibility of resin polymers used in dentistry. The majority of cells are cultured with Dulbecco's modified Eagle's medium (DMEM) or RPMI supplemented with fetal bovine serum. Several cell types are being studied including gingival fibroblasts. Gingival fibroblasts are the main cells of gingival connective tissue. These cells play an active and important role in almost all coating fabric processes, and its involvement in various pathophysiological conditions, including, healing, repair, aging, psoriasis, cancer among others, is only beginning to be understood. DMEM is the most widely used fibroblastic culture medium. This model describes a method for obtaining and cultivating human gingival fibroblasts, by explants derived from surgical discards. Fibroblasts were isolated mechanically and cultured in RPMI 1640 culture medium supplemented with fetal bovine serum 10%, Penicillin (10000 U/ml)/Streptomycin (10 mg/ml) 1% and L-Glutamine (200 mM) 1%. The culture medium is replaced every two days. Cells forming a fairly dense network were observed after a period of 4 days of culture. Human gingival fibroblasts can be cultured by direct explant technique with RPMI 1640 culture medium supplemented with fetal bovine serum and antibiotics.

  • Open Access

    Variability of slot size in orthodontic brackets

    by Clémentine Lefebvre, Hassan Saadaoui, Jean‐Marc Olive, Stéphane Renaudin, Fabienne Jordana

    Objective: The accuracy of the information incorporated into brackets is a determining factor for the efficacy of torque applied to teeth. The aim of this study was to compare the dimensions of a bracket's slots with the nominal values announced by the manufacturer.Materials and methods: A total of 730 maxillary right central brackets manufactured by seven companies (Dentsply Gac, American Orthodontics, Rocky Mountain Orthodontics, GC Orthodontics, 3M Unitek, and Dentaurum) were studied. The sample included 0.018 × 0.025 and 0.022 × 0.028 in., metal and ceramic, conventional and self‐ligating brackets. Images were obtained with an Olympus BX51 optical microscope. Slot dimensions were measured at the base and at the face on both mesial and distal sides using ImageJ software. Data were analyzed using Wilcoxon, sign tests, two‐ and three‐way ANOVA, and Tukey's tests. Intraclass correlation coefficient was employed to assess the intraobserver and interobserver variability. The threshold for statistical significance wasp≤ .05.Results: Statistical analysis showed that the slot dimensions of 90% to 97% of studied brackets were significantly different from nominal values. In general, slot size was oversized, with a face size larger than the base size. Comparison between mesial and distal sides showed that up to 45% of the brackets were significantly asymmetrical. The manufacturer had a significant effect for base and face widths (p= .0001) and for length (p= .003).Conclusion: This study shows that a large proportion of measured brackets displays dimensional inaccuracies when compared with stated values. Clinically, the slot oversize and the divergence of slot walls cause an increase of wire‐slot play, inducing a loss of torque control. Practitioners cannot fully trust the precision of used appliances and should be aware that adjustments could be needed in the finishing stages of the treatment.


  • Standardized bench test evaluation of coronary stents: Biomechanical characteristics

    by Mickael Bonin, Patrice Guerin, Jean Marc Olive, Fabienne Jordana, François Huchet

    Objectives: The purpose of the study was to develop a standardized and global bench test protocol to evaluate the biomechanical characteristics of the most currently used drug‐eluting coronary stents.Background: The use of coronary stents has contributed to the reduction of cardiovascular mortality but can be associated with specific complications. Improving the biomechanical matching between the stents and the coronary anatomy may reduce these complications.Methods: We assessed five commercially available drug‐eluting stents: the Absorb, Orsiro, Resolute Onyx, Synergy, and Xience Alpine stents. Following stent deployment at nominal pressure in ambient air, radial elastic recoil and foreshortening were measured. Flexibility (crimped and deployed stents) and longitudinal and radial resistances were evaluated using a mechanical tester.Results: Biomechanical characteristics were significantly different for all tested devices (ANOVA, P < 0.01). The Synergy, Orsiro, and Xience Alpine stents presented the lowest elastic recoil. The Synergy and Resolute Onyx stents were the most flexible devices. The Xience Alpine and Absorb stents had the highest longitudinal and radial resistances.Conclusions: Drug‐eluting coronary stents used in current clinical practice have very different biomechanical characteristics, which should be taken into consideration to select the most appropriate device for each clinical situation.